HyperShear TM HPLC Mixers

Similar documents
HyperShear TM HPLC Mixers

HyperShear TM HPLC and UHPLC Mixers

HyperShear TM HPLC and UHPLC Mixers

PrimeLine TM HPLC Pumps

QuickSplit TM Flow Splitters

Adjustable Flow Splitter *

Fixed Flow Splitter *

S 1125 HPLC Pump System

NEW HPLC - SYSTEM LINE

C196-E081C. Ultra High Performance Liquid Chromatograph Nexera X2. Specifications

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

QuickSplit TM Adjustable Flow Splitters Analytical Splitters Analytical range, 0.1 ml/min. to 5 ml/min. input flow, calibration flow rate 1.0 ml/min.

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271

VERITY Purification Systems Build the perfect system to fit your research

Mobile Phase Accessories

Liquid Chromatography

HPLC SYSTEM S 500 SERIES

ACQUITY UPLC I-Class System with 2D Technology

We guarantee that our prices are at least 25% lower! HPLC Pump Head. Mechanical Parts of an HPLC Pump Head. HPLC Pump component Manufacturers

HPLC Essentials Genuine Restek Replacement Parts for HPLC Systems

HPLC BRAND MODELS PAGE NO. Beckman/Altex 100A, 110A/B, 112/112M, 114/114M, 116, 118, 125, 126, 127, 128

HPLC System S 600 Series

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

available from Kinesis

Technical Overview. Introduction

Boosting Trace Detection Performance with the Vanquish Diode Array Detector and High-Sensitivity LightPipe Flow Cell

HPLC/UHPLC Pump Replacement Parts

2017 HPLC Product Catalog 1

HIGH PRESSURE SWITCHING VALVES

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

Liquid Chromatography LC Consumables SSI-LC

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

NEW? HPLC ACCESSORIES. What s. look for this circle

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

HPLC Accessories. HPLC Columns HPLC Applications

HPLC/UHPLC Pump Replacement Parts

Agilent 218 Purification Solution

Gilson, Inc. Table of Contents. Solid Phase Extraction Systems HPLC: Systems 2 9. Liquid Handlers HPLC: Liquid Handlers/Injectors 10 14

HPLC/UHPLC Pump Replacement Parts

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!

Sommaire - P19 AIT FRANCE. 2

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

ACQUITY UPLC I-Class System Specifications

Varian Dual Chamber Dynamic Mixer Instruction Manual

PATROL UPLC Process Analysis System for Production

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE

Gilson, Inc. Table of Contents. HPLC: Liquid Handlers/Injectors GX-271 Analytical Liquid Handler...43 ISO 9001 certified.

CTC Analytics Service Note June 2015 PAL-xt: Material change for Rotor Seal of C2V-3006-CTC

8 HPLC Fittings & Accessories

Upchurch High Pressure Fittings & Connectors

98 동방하이테크상사 T.(02) F.(02)

Application Note. Authors. Abstract. Energy & Chemicals

ÄKTA system Training Guide. Purifier 100 / 10. amersham bio science

Agilent 7693A Automated Liquid Sampler

Determination of Sudan Dyes I IV in Curry Paste

GENERAL CATALOG L.TEX CORPORATON

The Agilent 1200 Series high perfor- mance autosampler SL: Area precision, injection volume linearity, minimum accessible volume, carry-over

Stability Axial Compression Technology Application Ordering Information

replacement parts hplc & uhplc oem systems replacement parts

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis

ÄKTA system Training Guide

Instrumentation of HPLC. HPLC Solvent Pumping Systems

HPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage.

Agilent 7693A Automated Liquid Sampler

ProStar 210 PrepStar 218 Solvent Delivery Module

Agilent 1290 Infinity II Ultra Low Dispersion Kit

LC Accessories Instrument Replacement Parts For Agilent HPLC Systems For PerkinElmer HPLC Systems For Shimadzu HPLC Systems...

78 동방하이테크상사 T.(02) F.(02)

Teledyne Isco D-Series Syringe Pumps

ProStar 340 UV-Vis Detector

Filters & Frits. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159

Thermo Scientific Dionex UltiMate 3000 Pumps

The Only No Compromise

PrimeLine TM. Replacement Parts. for HPLC Pumps. All check valves are self-priming, no external priming valve/syringe required

ÄKTA avant 150. Product Documentation

economics and performance Spark Holland introduces OPTIMAS The optimum balance of BETTER SAMPLE CARE

GlycoChrom TM HPLC Analyzer. Hardware Installation and System Test

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Ultra High Performance Fittings. Fittings Connectors Kits

High Pressure Valves. MX Series II Modules Manual Sample Injection Switching

Chrom Tech your chromatography specialists. IDEX Injection Valves Manual. IDEX Injection Valves Actuated. 1/4-28 Flat-Bottom Injection Port Adapter

Mitos P-Pump Accessories

IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159

Technical Procedure for Gas Chromatography (GC-FID)

Phase Distribution of Ethanol, and Water in Ethyl Esters at K and K

GLENCO Syringes. Spectrum Double Action Syringes. Spectrum Double Action Removable Needle Micro Syringes Glenco Series 19913

Simplify your search for. You will find both PEEK-lined stainless steel hardware as well as standard ss column hardware at the below stockingstations.

Agilent Valve Kit G4231A/B and G4232A/B/C

Agilent G5632 Valve Kit Instructions

Large Volume Injection of Polycyclic Aromatic Hydrocarbons

LC Instrument Replacement Parts

Mobile Phase Management

Agilent SD-1 Purification System ml/min

Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS

One-Piece UPchurch Fingertight Fittings 1,2. ChromTRAC. TOP SELLER see starred products in price block. Fingertight Fittings.

Transcription:

HyperShear TM HPLC s HyperShear TM HPLC Features: Static or Dynamic s with highly efficient vortex sheer mixing Reduce baseline noise, increase sensitivity, and improve gradient accuracy Mixing volume optimization is easy with interchangeable mixer cartridges In-line, binary, and ternary formats Available in stainless steel or biocompatible PEEK Ideal for microbore HPLC and LC/MS Compact design is easily integrated into any HPLC system Increased reaction efficiency for post column derivatization http://www.hplc-asi.com 1

HyperShear TM HPLC s ASI manufactures a wide range of s to solve the most demanding HPLC mixing problems. ASI HyperShear HPLC s incorporate a highly efficient cross-flow shearing mechanism which produces vortex sheer mixing over a wide flow range. This mixing technology typically delivers between 25 % to 200 % better mixing efficiency compared to conventional stir bar or tortuous path mixers. HyperShear HPLC s are available in both static and dynamic formats with volumes ranging from 0.5 µl to 1.5 ml. Most mixers are available in biocompatible PEEK. Comparison of Baseline Noise The baseline of this plot has been enlarged to show the noise levels associated with each mixer. Note the significant reduction in baseline noise with the ASI static mixer. Conditions: Gradient Program: CH3CN/H2O = 50/50 --> (15 min.) 90/10 Flow Rate: 0.1mL/min. Temp.: 40 C Sample Size: 1µL Sample: Solvent front Detection Wavelength: 254nm Table of Contents HyperShear Static s Micro Flow Series, Mixing Volumes 0.5 µl to 25 µl... 3 Low Flow Series, Mixing Volumes 50 µl to 250 µl... 5 Analytical Flow Series, Mixing Volumes 350 µl and 500 µl... 9 High Flow Series, Mixing Volumes 800 µl to 1.5 ml... 11 Static Application Notes... 13 HyperShear Dynamic s... 18 2 To order call 800-344-4340

Micro Flow Series Stainless Steel Complete Assembly - Cartridge and Housing Assembly SS 0.5 µl 401-000. 5 Assembly SS 1 µl 401-0001 Assembly SS 2 µl 401-0002 Assembly SS 5 µl 401-0005 Assembly SS 10 µl 401-0010 Assembly SS 25 µl 401-0025 Assemblies 0.5µL, 1µL, 2µL, 5µL, 10µL or 25µL Cartridge Port Size: 10-32 CPI ( Standard HPLC Fittings for 1/16 Tube) http://www.hplc-asi.com 3

Tee Complete Assembly, Stainless Steel - Cartridge and Housing Tee Assembly SS 0.5 µl 402-000. 5 Tee Assembly SS 1 µl 402-0001 Tee Assembly SS 2 µl 402-0002 Tee Assembly SS 5 µl 402-0005 Tee Assembly SS 10 µl 402-0010 Tee Assembly SS 25 µl 402-0025 Tee Complete Assembly, Stainless Steel - Cartridge and Housing ASI Part Number Tee Assembly SS 0.5 µl 403-000. 5 Tee Assembly SS 1 µl 403-0001 Tee Assembly SS 2 µl 403-0002 Tee Assembly SS 5 µl 403-0005 Tee Assembly SS 10 µl 403-0010 Tee Assembly SS 25 µl 403-0025 / Assemblies 0.5µL, 1µL, 2µL, 5µL, 10µL or 25µL Cartridge Port Size: 10-32 CPI Cartridges / Housings Cartridge SS 0.5 µl 400-000. 5 Cartridge SS 1 µl 400-0001 Cartridge SS 2 µl 400-0002 Cartridge SS 5 µl 400-0005 Cartridge SS 10 µl 400-0010 Cartridge SS 25 µl 400-0025 Micro Flow Series SS Housing 401-0000 Tee Micro Flow Series SS Housing 402-0000 Tee Micro Flow Series SS Housing 403-0000 4 To order call 800-344-4340

Low Flow Series Stainless Steel Complete Assembly - Cartridge and Housing Assembly SS 50 µl 411-0050 Assembly SS 150 µl 411-0150 Assembly SS 250 µl 411-0250 Assemblies 50µL, 150µL or 250µL Cartridge Port Size: 10-32 CPI (Standard HPLC Fittings for 1/16 Tube) http://www.hplc-asi.com 5

Tee Complete Assembly - Cartridge and Housing Tee Assembly SS 50 µl 412-0050 Tee Assembly SS 150 µl 412-0150 Tee Assembly SS 250 µl 412-0250 Tee Complete Assembly - Cartridge and Housing Tee Assembly SS 50 µl 413-0050 Tee Assembly SS 150 µl 413-0150 Tee Assembly SS 250 µl 413-0250 / Assemblies 50µL, 150µL or 250µL Cartridge Port Size: 10-32 CPI Cartridges / Housings Cartridge SS 50 µl 410-0050 Cartridge SS 150 µl 410-0150 Cartridge SS 250 µl 410-0250 Low Flow Series SS Housing 411-0000 Tee Low Flow Series SS Housing 412-0000 Tee Low Flow Series SS Housing 413-0000 6 To order call 800-344-4340

Low Flow Series Biocompatible PEEK Complete Assembly - Cartridge and Housing Assembly PEEK 50 µl Assembly PEEK 150 µl Assembly PEEK 250 µl 411-0050B 411-0150B 411-0250B Assemblies 50µL, 150µL or 250µL Cartridge Port Size: 10-32 CPI (Standard HPLC Fittings for 1/16 Tube) http://www.hplc-asi.com 7

Tee Complete Assembly - Cartridge and Housing Tee Assembly PEEK 50 µl Tee Assembly PEEK 150 µl Tee Assembly PEEK 250 µl 412-0050B 412-0150B 412-0250B Tee Complete Assembly - Cartridge and Housing Tee Assembly PEEK 50 µl Tee Assembly PEEK 150 µl Tee Assembly PEEK 250 µl 413-0050B 413-0150B 413-0250B / Assemblies 50µL, 150µL or 250µL Cartridge ASI Port Size: 10-32 CPI Cartridges / Housings Cartridge PEEK 50 µl Cartridge PEEK 150 µl Cartridge PEEK 250 µl Low Flow Series PEEK Housing Tee Low Flow Series PEEK Housing Tee Low Flow Series PEEK Housing 410-0050B 410-0150B 410-0250B 411-0000B 412-0000B 413-0000B 8 To order call 800-344-4340

Analytical Flow Series Stainless Steel, Biocompatible PEEK Complete Assembly - Cartridge and Housing Stainless Steel Assembly SS 350 µl 421-0350 Assembly SS 500 µl 421-0500 Biocompatible PEEK Assembly PEEK 350 µl Assembly PEEK 500 µl Assemblies 421-0350B 421-0500B 350µL or 500µL Cartridge Port Size: 10-32 CPI (Standard HPLC Fittings for 1/16 Tube) http://www.hplc-asi.com 9

Complete Assembly, Stainless Steel - Cartridge and Housing Tee Assembly SS 350 µl 422-0350 Tee Assembly SS 500 µl 422-0500 Complete Assembly, Stainless Steel - Cartridge and Housing Tee Assembly SS 350 µl 423-0350 Tee Assembly SS 500 µl 423-0500 / Assemblies 350µL or 500µL Cartridge Port Size: 10-32 CPI Cartridges / Housings Stainless Steel Cartridge SS 350 µl 420-0350 Cartridge SS 500 µl 420-0500 Analytical Flow Series SS Housing 421-0000 Tee Analytical Flow Series SS Housing 422-0000 Tee Analytical Flow Series SS Housing 423-0000 Biocompatible PEEK Cartridge PEEK 350 µl Cartridge PEEK 500 µl Analytical Flow Series PEEK Housing 420-0350B 420-0500B 421-0000B 10 To order call 800-344-4340

High Flow Series Stainless Steel, Biocompatible PEEK Complete Assembly - Cartridge and Housing Stainless Steel Assembly SS 800 µl 431-0800 Assembly SS 1.0 ml 431-1000 Assembly SS 1.5 ml 431-1500 Biocompatible PEEK Assembly PEEK 800 µl Assembly PEEK 1.0 ml Assembly PEEK 1.5 ml Assemblies 431-0800B 431-1000B 431-1500B 800uL, 1.0mL OR 1.5mL CARTRIDGE 800µL, 1.0mL or 1.5mL Cartridge ASI I 2.68 1.43 Port Size: 10-32 CPI (Standard HPLC Fittings for 1/16 Tube) http://www.hplc-asi.com 11

Complete Assembly, Stainless Steel - Cartridge and Housing Tee Assembly SS 800 µl 432-0800 Tee Assembly SS 1.0 ml 432-1000 Tee Assembly SS 1.5 ml 432-1500 Complete Assembly, Stainless Steel - Cartridge and Housing Tee Assembly SS 800 µl 433-0800 Tee Assembly SS 1.0 ml 433-1000 Tee Assembly SS 1.5 ml 433-1500 / Assemblies 800uL, 1.0mL OR 1.5mL CARTRIDGE 800µL, 1.0mL or 1.5mL Cartridge ASI I 2.60 FLOWLOCK INPUT PORTS 1.43 Port Size: 10-32 CPI Cartridges / Housings Stainless Steel Cartridge SS 800 µl 430-0800 Cartridge SS 1.0 ml 430-1000 Cartridge SS 1.5 ml 430-1500 High Flow Series SS Housing 431-0000 Tee High Flow Series SS Housing 432-0000 Tee High Flow Series SS Housing 433-0000 Biocompatible PEEK Cartridge PEEK 800 µl Cartridge PEEK 1.0 ml Cartridge PEEK 1.5 ml High Flow Series PEEK Housing 430-0800B 430-1000B 430-1500B 431-0000B 12 To order call 800-344-4340

Static Application Notes Selecting the Right Size Cartridge ASI offers static mixers with volumes that range from 0.5 microliters to 1,500 microliters. Choosing the right size mixer is a trade off between delay volume, mixing noise, and step gradient definition and repeatability. Please refer to the Charts on pages 48 and 49 for more information on gradient accuracy as a function of flow rate and mixing volume. The following observations will provide some guidelines to help choose the right size mixer. Ø Ø Ø Ø For any given flow rate, the more the mixing volume the better the mixing, and the lower the baseline noise. The smaller the mixing volume, the better the definition and sharpness of linear gradients. Multi-pump high pressure gradient systems typically reuire far less mixing volume than low pressure single pump gradient systems when running linear gradients. A 150 µl in-line static mixer can be added after a dynamic or static onboard mixer to further reduce mixing noise. Multi-pump High Pressure Gradient Systems Linear Gradients If a larger mixing volume can be tolerated for a particular flow rate, the larger the volume will lower the mixing noise. The upper limits to mixing volume will be the maximum delay time that can be tolerated, and possible distortion (tailing) of the gradient at the beginning and end of the gradient. The lower limit will be defined by the amount of mixing noise that can be tolerated. Please refer to table 1 (page 47) for specific recommendations. or Steady State Composition Always select the largest volume that will still provide an acceptable delay volume. In general, the more mixing volume, the better the mixing will be. For most pump systems, a 150 µl cartridge will provide adeuate mixing. Examples of this type of pump system include: Shimadzu LC-10AD and LC-10ADVP Beckman System Gold Gilson Model 305 Agilent Model 1100 http://www.hplc-asi.com 13

Single-pump Low Pressure Mixing Gradient Systems Linear Gradients These systems generally reuire more mixing volume to perform linear gradients than multipump high pressure systems. The following will explain why this is the case. In a low pressure system the composition can only be changed once every pump stroke. Since the pump stroke volume of most pumps is 100 µl, and it takes a mixer volume that is about 3 times the batch volume to provide adeuate mixing, we need 350 µl of mixer volume, at least, to do adeuate mixing. More insoluble combinations may reuire even more mixing volume. In general, choose the largest size mixer cartridge that will still provide an acceptable delay volume. For most applications this will be at least 350 µl. or Steady State Composition Always select the largest volume that will still provide an acceptable delay time. In general, the more mixing volume, the better the mixing will be. For most applications this will be at least 350 µl. Examples of this type of pump system include: Agilent 1090 Perkin Elmer series 200 TSP Spectra Vision Waters model 626 Varian Star 9000 Cartridge Selection Guide for High Pressure Mixing Linear Gradients - High Pressure Mixing Larger mixing volume can be tolerated for a particular flow rate, with the larger the volume the lower the mixing noise. The upper limits to mixing volume will be the maximum delay time that can be tolerated, and possible distortion (tailing) of the gradient at the beginning and end of the gradient. The lower limit will be defined by the amount of mixing noise that can be tolerated. The following cartridge volumes are a compromise between these two limits. Table 1. Flow 0-5 micro liter/min. 5-10 10 10-20 25 20-150 50 150-500 150 500+ 250 Cartridge Volum e 5 micro liter 14 To order call 800-344-4340

Chart 1 Effect of Volume on Gradient Accuracy with a Constant Flow Rate ASI 50 µl mixer, 25 µl/min. ASI 25 µl mixer, 25 µl/min. ASI 10 µl mixer, 25 µl/min. ASI 10 µl mixer, 25 µl/min. HPLC System configuration: Shimadzu LC-10ADVP pumps with micro-flow modification Shimadzu SPD-10AVP UV-VIS detector Shimadzu Class-VP v5.03 software HPLC conditions: Gradient: 10-90% B in 10 min. steps A = H2O B = 0.3% Acetone in H2O http://www.hplc-asi.com 15

Chart 2 Effect of Flow Rate on Gradient Accuracy with a Constant Mixing Volume ASI 25 µl mixer, 10 µl/min. ASI 25 µl mixer, 25 µl/min. ASI 25 µl mixer, 50 µl/min. ASI 25 µl mixer, 100 µl/min. HPLC System configuration: Shimadzu LC-10ADVP pumps with micro-flow modification Shimadzu SPD-10AVP UV-VIS detector Shimadzu Class-VP v5.03 software HPLC conditions: Gradient: 10-90% B in 10 min. steps A = H2O B = 0.3% Acetone in H2O 16 To order call 800-344-4340

Static Comparison -10 µl mvolts -0.50 Less Noise - Lower Detection Limits -0.75-1.00-1.25-1.50 No - Valco Tee & 10 µl Tubing mvolts -0.50-0.75-1.00-1.25 L - 10 µl -1.50 mvolts -0.25-0.50-0.75 ASI HyperShear - 10 µl C -1.00 Minutes HPLC System Configuration: ASI Model 500G Gradient System ABI Model 785 UV/VIS @ 254 on-column Varian Star Data Acuisition HPLC Conditions: MP: A = H2O, B = H2O/Acetone Flow Rate: 50µL/min. 50% B Pressure: 1,700 PSI with restrictor Superior Mixing with Less Dispersion mvolts No - Valco Tee & 10 µl Tubing HPLC System Configuration: Above HPLC Conditions: Above Isocratic Flow Rate: 50µL/min. 100% A One Inlet Port Plugged Injection: 600nL Acetone ASI HyperShear - 10 µl C L - 10 µl Minutes http://www.hplc-asi.com 17

HyperShear TM Dynamic s HyperShear Dynamic, 1.0 ml HyperShear Combination Static/Dynamic, 150 µl, 250 µl or 350 µl HyperShear TM Dynamic Features: Vortex sheer mixing that is twice as efficient as conventional stir bar mixers Models with fixed or adjustable mixing volumes Compact design allows easy integration into any HPLC system Available in 120 VAC or 220 VAC / Complete Assembly Tee Dynamic Assembly 150 µl 120 VAC Tee Dynamic Assembly 150 µl 220 VAC Tee Dynamic Assembly 250 µl 120 VAC Tee Dynamic Assembly 250 µl 220 VAC Tee Dynamic Assembly 350 µl 120 VAC Tee Dynamic Assembly 350 µl 220 VAC Tee Dynamic Assembly 1.0 ml 120 VAC Tee Dynamic Assembly 1.0 ml 220 VAC Tee Dynamic Assembly 1.0 ml 120 VAC Tee Dynamic Assembly 1.0 ml 220 VAC 462-0150A 462-0150U 462-0250A 462-0250U 462-0350A 462-0350U 462-1000A 462-1000U 463-1000A 463-1000U 18 To order call 800-344-4340