Test report no

Similar documents
Test report No

Test report No

European B1 Fire Rating. soft collection softwall + softblock Fire Retardant (FR) Treated textile products. molo design, ltd

Test report No

Test report No

Test report No

Test report No

Germany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7

Classification report No K1

Test report no

Test Report No

Test report no

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5

Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6

TEST REPORT Reference No. : TRHZ _R1 Date : Nov. 27, 2012 Page No.: 1 of 5

Catalogue Partition rooms flexibly. Protect personal privacy. Curtains. Screen Systems

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

FIRE TEST REPORT FH 5154

Report Test Report

Sound-absorbing spacer Sorp10

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

FIRE TEST REPORT FH 5728

EU Mutual Recognition Technical Requirements

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

The Furniture Retail Quality Group Best Practice Guide

National Standard of People s Republic of China

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

Test Report Order No _A1 / Part Hessisch Oldendorf. Order: Test of the electrostatic properties of a resilient floor coverings coated

VAUTH ANALYSING. TESTING. CERTIFYING. aviation components

FIRE TEST REPORT FH 5078

Full extension concealed slide with soft closing and self-closing

TEST REPORT MEDICAL VEHICLES AND THEIR EQUIPMENT TABLE FOR AMBULANCE STRETCHER

DNVGL-CP-0110 Edition March 2016

Lab services for aircraft interior components

Test report. About the effect of Lambda System Cleaning Products. No

EC type-examination of SITEMA Safety Brakes by DGUV Test

Confirmation: / 22 March 2013

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill

E/ECE/324/Rev.2/Add.117/Amend.1 E/ECE/TRANS/505/Rev.2/Add.117/Amend.1

Title: The Fire Resistance Performance of Modified Doorsets. WF Assessment Report No: Prepared for:

Inspection Report. Coating name: IGP HWFclassic IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number:

InnoBYG small scale demonstration tests - Part 1

Contact person Date Reference Page Michael Lindblad F013838C 1 (1) Sustainable Built Environment

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg

FIROFLEX IP. Synthetic rubber for secure protection against the formation of condensation

ISO :2015/DAM 1

INVESTIGATION OF DENTAL LUBRICANTS

Grade A. Evo EV-19 EV-5 EV-4 EV-2 EV-18 EV-14 EV-10 EV-22 EV-20 EV-21 EV-1 EV-23 EV-24 EV-25. Discover more at inscapesolutions.

InnoBYG small scale demonstration tests - Part 2

Title: The fire resistance performance of a specimen of single-acting single-leaf doorset in accordance with BS EN : Report No: A

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

EN 1154:1997 / A1:2002

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

No carcinogenic nitrosamine generating raw materials are used.

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:

RENOSAFE FireProtect 46, 68 Fire resistant hydraulic fluid, based on new ester and additive technology, Type HFDU

Guidelines for the application of EN to electrical and electronic insulating materials

THE NETHERLANDS (N E D E R L A N D) COMMUNICATION. Approval number: E4-23R Extension number: 00

Test Report issued under the responsibility of: Report Reference No... : AS9-7 Date of issue... : Total number of pages...

SFI SPECIFICATION 3.2A EFFECTIVE: APRIL 20, 2018 *

Determination Of Fire Effluents From Products On Railway Vehicles

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

13 th December Title: The Fire Resistance Performance Of Doorsets When Fitted With Perko Powermatic R100 Jamb Mounted Concealed Door Closers

Page 1(5) Quality department P.O. Box 22 TEST REPORT 579/16 FIN Nummela Finland

FLASH POINT TESTER. Instruction Manual. 0. Health and Safety Advice. 1. Introduction

7300 TERMINAL DESIGN BY KUSCH+CO DESIGNTEAM, EICHINGER & LOIDOLT

A Case Study: Review of Flammability Product Testing, the Similarities and Differences Ellen Roaldi Bureau Veritas Consumer Products Services

Certificate: / 22 March 2013

DEUTSCHE NORM DIN 8077

7300 TERMINAL DESIGN BY KUSCH+CO DESIGNTEAM, LOIDOLT & EICHINGER

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

MITRAS MATERIALS GMBH

Test Report No

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

Contact person Date Reference Page Ulf Lemke F015337C 1 (4) Wood Technology

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

KAIFLEX PRODUCT BROCHURE

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19 July Köln, 17 August 2012

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Technical information No. 01. IT systems. The basis for reliable power supply

Sarnafil TS E. Polymeric membrane for roof waterproofing. Product Description

TEST REPORT FOR: Product Design Group Fuze T50 Manual Wheelchair (204 kg / 450 lb)

Approval mark PL HCR 1a A

TEST REPORT. No. 284a/14

FIBRE UKANOL ES REACTIVE FLAME RETARDANT ADDITIVE FOR POLYESTER

Precision engineered to the highest Australian Standards, you ll find Ardent copper fittings and coils for just about every application. Ardent.

Trailer EBS E 98/91/EG dated ECE-R 105 including amendment 04 and Chapter ADR 2009

DECLARATION OF CONFORMITY REGARDING RESTRICTIONS OF HAZARDOUS SUBSTANCES IN ELECTRICAL AND ELECTRONIC EQUIPMENT

FPA4 DATASHEET JUNHO 2013

Transcription:

Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report no. 2015-1339 for applying of a required Verwendbarkeitsnachweis issued 07.04.2015 Applicant: Gabriel A/S Hjulmagervej 55 DK 9000 Aalborg Date of order: 23.03.2015 Date of sampling: no official sampling of the specimen by a representative of Exova Warringtonfire, Frankfurt Date of arrival: 13.03.2015 Date of test: 30.03.2015 Order Testing of the normal flammability (Building Class B2) according to DIN 4102-1 (May 1998) Description / designation of the test object Trade name: Europost 2 Description of the relevant test procedure DIN 4102 part 1 (May 1998) This test report did not replace the required Verwendbarkeitsnachweis (official approval document). It is only used for issuing the Verwendbarkeitsnachweis. Registered Office: Exova GmbH, Industriepark Höchst, C369, Frankfurt, D-65926, Registered Company No. HRB 83049 Ust-Id Nr. DE259957713 08.04.2015

Test report no. 2015-1339 issued 07.04.2015 page 2 of 5 1. Description of the test material 1.1 Details of the customer: Trade name: Europost 2 Construction: Application: Upholstery Material: 100% Wool Type of production: Weaved Thickness: 2 mm Square weight: 570 g/m² Color: 61003 Flame-retardant(s) No used: 1.2 At the specimen preparation by Exova Warringtonfire, Frankfurt determined values: Fabric sample: Colour: Thickness: Square weight: beige 1,86 mm 606 g/m² The samples were stored 14 days before testing under climatic conditions (23 C / 50 % rel. humidity).

Test report no. 2015-1339 issued 07.04.2015 page 3 of 5 2. Test results 2.1 Normal flammability test according to DIN 4102-1 Test with edge ignition without deposit Flame application on: lower specimen edge length direction: Specimen-no. 1 2 3 4 5 Ignition point [s] 1 1 1 1 1 Reaching the measuring mark (150 mm) within 20 seconds Self extinguishing of the flame [s] - - - - - Max. flame height [mm] 110 100 110 120 110 Time [s] 20 20 20 20 20 Afterflaming [s] - - - - - Afterglowing [s] - - - - - Flames extinguished after [s] 25 25 25 25 25 Smoke development (visuell impression) strong smoke development Separating from burning material up to 20 sec. Time [s] - - - - - Remarks: none. cross direction: Specimen-no. 1 2 3 4 5 Ignition point [s] 1 1 1 1 1 Reaching the measuring mark (150 mm) within 20 seconds Self extinguishing of the flame [s] - - - - - Max. flame height [mm] 100 110 90 90 100 Time [s] 20 20 20 20 20 Afterflaming [s] - - - - - Afterglowing [s] - - - - - Flames extinguished after [s] 25 25 25 25 25 Smoke development (visuell impression) strong smoke development Separating from burning material up to 20 sec. Time [s] - - - - - Remarks: none.

Test report no. 2015-1339 issued 07.04.2015 page 4 of 5 Appearance of the specimen after the small burner test:

Test report no. 2015-1339 issued 07.04.2015 page 5 of 5 3. Assessment The material described on chapter one fulfils the requirements of the Building Class B2 according to DIN 4102-1 (May 1998). 4. Special comment The fire test result is only valid for the in chapter one described material in free hanging configuration. In the composition with other materials (for example coatings, deposits) the burning behaviour could be influenced unfavourable so that the above classification is not any longer valid. According to DIN 4102-1 the burning behaviour in composition with other materials has to be tested separately. This test report did not replace the required Verwendbarkeitsnachweis. It is only used for issuing the Verwendbarkeitsnachweis. Frankfurt, the 07.04.2015 H. Anders Dipl.-Ing. T. Zachäus Tester in Charge Laboratory Supervisor This Test report is valid until 29.03.2020 The results of the tests relate only to the behaviour of the test specimen which is designated on the top. Test reports are only allowed to be published or reproduced, not changed in form and tenor without permission of the Exova Warringtonfire, Frankfurt. The abridged account of a test report is only allowed with the agreement of the Exova Warringtonfire, Frankfurt. This test report is a translation of the German version 2015-1339 (issued 07.04.2015). In case of doubt only the German version is valid The test report contains 5 pages