CMF2 Series Applicable cylinder bore size: Max. ø160

Similar documents
5 Port Solenoid Valve

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

5 Port Solenoid Valve

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

3GA1/2/3, 4GA1/2/3 Series Applicable cylinder bore size: ø20 to ø100

5 Port Solenoid Valve

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold

5 Port Solenoid Valve

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Series VQZ1000/2000/3000 Single Unit

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating,

VQ1000. How to Order Manifold. Kit type

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2

Solenoid Pilot Operated Directional Control Valve

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

4/5 Port Solenoid Valve

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

4/5 Port Solenoid Valve

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Symbol. Single DS 2120 R2 P R1. How To Order. Body Type 2 : Body Ported Type. Body Option O : Standard

New Products. 3 Port Solenoid Valve with Spool Position Detection SNP Series

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

Base Mounted Plug-in/Plug Lead: Single Unit

BST / BSG-03 / 06 / 10 Threaded Connections / Sub-plate Mounting. Specifications / Model Number Designation. Max. Flow L/min (U.S.GPM) Double Sol.

Direct Operated Type Solenoid Operated Proportional Throttle Valve

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

RA / /3, 4/2 and 3/2-Way Directional Valves Model.WE 10.../.D, Series 3X with Wet Pin DC Solenoids. Functional description, section

B8_58 (EDBZ-VEI) RE Edition: Replaces:

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Direct Operated Type Solenoid Operated Proportional Throttle Valve

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Coolant Valve. Air Operated/External Pilot Solenoid

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Air Valve AIR-PILOTED VALVES

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

High Pressure Coolant Valve

Plug-in manifold W4G4 Series

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

HN B G1/US B G2/US B G3

Pilot operated 2 port solenoid valve (general purpose valve) AP11/AP12 Series. Air, water, kerosene, oil (50 mm 2 /s or less) -10 to to 60 B

82170/ /2-way diaphgram valves

3 Port Solenoid Valve

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

Series SY3000/5000 How to Order Manifold

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511

5 Port Solenoid Valve

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

Directional Control Valves. General Description. Operation. Features

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

Individual wiring manifold Sub base porting Direct mount type/din rail mount type M4GB1 2 3/M4GB1 2 3-D Series

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

Manifold Specifications Stacking Type

Directional Control Valves. Features. Application. Operation

5 Port Solenoid Valve

DIRECTIONAL CONTROL (LD) DIRECTIONAL AND FLOW CONTROL (LD) SOLENOID OPERATED DIRECTIONAL

Example. U side. Stations SY5000

3 Port Solenoid Valve

CVE2/CVSE2 CVE3/CVSE3

Gateway System Serial Transmission System

385 & 962 Series The lectroaire valve is a compact, air operated, electrically lectroaire valves can be remotely mounted for control of double acting

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

MRK 25 M a r k 2 5 d i r e c t s o l e n o i d a c t u a t e d v a l v e s T C H N C L T V L V M

Series AV2000/3000/4000/5000

Bar 35 PSI 500. Pressure Drop L/M GPM. Flow

3 Port Solenoid Valve Direct Operated Poppet Type

IFP DG08 SOLENOID CONTROLLED PILOT OPERATED DIRECTIONAL VALVE SIZE NG22/CETOP08

NO (normally closed) type Common supply type (port C pressurization) MPa MPa MPa C C

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8

0.35 W (Without light)

5.2 to 79 gpm 3000, 3600, 5000 psi

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Air Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description

Series ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc.

Functional Symbols and Application Notes

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Directional control - SRK series Solenoid valve

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Spool & Sleeve Valves for ANSI Sub-Bases Series W70

Solenoid Pilot Operated Directional Control Valve

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Solenoid Pilot Operated Directional Control Valve

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

Transcription:

4G/ M4G/ Individual wiring manifold ISO size 2 DIN terminal ox type 5 port pilot operated valve ISO conformed valve 2 Series pplicale cylinder ore size: Max. ø160 MN4G/ Common specifications 4G/ W4G/2 Manifold method W4G4 Manifold type Station numer Type of valve and operator 4T 4S/0 Working fluid Max. working pressure Ma Min. working pressure Ma Withstanding pressure Ma mient temperature C 4S/1 Fluid temperature C 4K/ Lurication rotective structure Leakage cm 3 /min. (, R port) Viration/impact m/s 2 Working environment 3M/0 3/ Note 1: Use the supply pressure at R1 > R2 Note 2: Indicates the default. Electric specifications Rated voltage C /M/ V N/N/ DC Rated voltage fluctuation range *0E pparent power (mpere ) V Note 3 ower consumption W (mpere ) Heat proof class Wiring methods C DC 100 V 110 V 12 V 24 V Note 3: The C type current is the holding current. Manifold integrated Common supply / common exhaust, common supply / individual exhaust Individual supply / common exhaust, individual supply / individual exhaust Multi-pressure air supply 1 to 10 stations ilot operated soft spool valve Compressed air 1.0 0.15 0.20 (3-position) Note 1 1.50-5 to 60 (no freezing) 5 to 60 Not required Dust proof, jet-proof (I65 or equivalent) 10 (NR) or less 3-position all ports closed non-leak type only 0.3 (NR) or less Note 2 50 or less / 300 or less Use in the environment containing corrosive gas is not permissile. 0.15 Ma only for YZ-S. Without light 2.3 (0.023) (0.023) 1.0 (0.083) 1.0 (0.042) 100 (50 / 60 Hz) 110 (50 / 60 Hz) 12, 24 ±10% (molded coil) Electric plug connector With light 2.4 (0.024) 2.6 (0.024) 1.2 (0.100) 1.2 (0.050) Individual specifications ort size Note 1 Response time Note 2 ms /R1/R2 port / port Single solenoid 2-position Doule solenoid 3-position 2 Rc1/2, Rc3/4 Rc3/8 Rc1/2 40 (when ON), 60 (when OFF) 40 40 (when ON), 60 (when neutral) Note 1: G threads and NT threads are availale for the piping port threads. Contact CKD for information. Note 2: Response time is the value at an air supply of 0.5 Ma, and oil-free. The value will change ased on quality of pressure and oil. 1000

Flow characteristics / Model no. ort size Solenoid position C (dm 3 / (s ar)) 2-position single solenoid 2-position doule solenoid 9.7 9.7 2 Rc3/8 3-position all ports closed 9.2 3-position //R connection 9.2 3-position // connection 3-position all ports closed non-leak 9.6 6.2 Note 1: Effective sectional area S and sonic conductance C are converted as S 5.0 C. - 2 Series / R1/R2 C (dm 3 / (s ar)) 11.0 0.14 11.0 0.14 10.1 0.15 11.6 10.2 0.18 5.9-4G/ M4G/ MN4G/ 4G/ W4G/2 W4G4 4T 4S/0 4S/1 4K/ 3M/0 3/ /M/ N/N/ *0E Individual wiring manifold 5 port pilot operated valve 1001

M4G/ MN4G/ 4G/ W4G/2 W4G4 4T 4S/0 4S/1 4K/ 3M/0 3/ /M/ N/N/ *0E 2 Series How to order DIN terminal ox type ISO size 2 4G/ 2 5 03 L 04 <Example of model numer> 25-03L-04-S Model: Manifold ISO size 2 D G Model no. Note on model no. selection Note 1: The port size for HX is mixed. Contact CKD for details. Note 2: "C" indicates the port position. ll positions are pluged unless otherwise indicated. Note 3: "E" indicates the port position. The opposite side of the indication is pluged. Note 4: If "G", type with silencer ox is selected, the port position can e selected. Select from, D, U, or T. Note 5: If "G," type with silencer ox is selected, the top and ottom are oth assemled with plugs. Station numer C / port E /R port Silencer ox Station numer : 5 stations : Rc3/8 (oth left-right sides porting) : Rc1/2 (oth upper-ottom sides porting) : Selected (D side installation) U side (upper) R1 R2 / port size Note 1 C / port position Note 2 D /R port size S E /R port position Note 3 Note 4 F HY configuration G Silencer ox Note 5 Symol Station numer 1 1 station to to 10 10 stations / port size 03 Rc3/8 04 Rc1/2 HX2 Rc1/2, Rc3/8 mix C / port position lank Right L Left/right sides (select position with manifold specifications) H Left Z Rear T Flexile selection (plug attached) D /R port size 04 Rc1/2 06 Rc3/4 HY2 Rc1/2, Rc3/4 mix E /R port position Upper / ottom sides D ottom side U Upper side E upper, R ottom F ottom, R upper T Flexile selection (plug attached) F HY configuration lank When HY2 is not selected for "D" DU Rc1/2 ottom, Rc3/4 upper UD Rc1/2 upper, Rc3/4 ottom G Silencer ox lank None S Selected (D side installation) Model no. 2 The valve is ordered separately. Refer to page 990 for how to order the valve. When ordering a manifold with a valve, each model no. and the manifold specifications given on page 1012 are required. L side (left) R side (right) R1 R2 D side (ottom) Without control unit 1002

2 Series 4G/ M4G/ Dimensions: DIN terminal ox type 2 Common exhaust L2 (56n + 74) L1 (56n + 54) /R port size Rc1/2 Rc3/4 30 32 25 MN4G/ 4G/ 4n-M6 depth 12 38 R side 2-Rc1/8 ilot exhaust port 61 50 W4G/2 W4G4 U side 160 144 120 48 24 U D 97 (silencer ox) 52.8 (m.-override pos.) 105.6 (m.-override pos.) 72.8 140.6 (2 position single) 145.6 (2 position doule) 162.6 (3 position) D side R R 33 33 4T 4S/0 4- (11 13) installation hole L side 11.5 4 3 6 -Rc1/2, 3/4 4S/1 4K/ 2n 4n-Rc3/8, 1/2 66.5 (silencer ox) 161.4 172.7 232.7 45 56 56 22 54 3M/0 3/ /M/ N/N/ 2 Individual exhaust Individual supply spacer Individual exhaust spacer Exhaust pressurization individual exhaust spacer 4 *0E 2n 4n-Rc3/8, 1/2 201.4 212.7 272.7 45 54 88 22 2 ack porting L side 56 56 2-Rc3/8,1/2 U side 35 25 120 144 160 D side 33 33 R R 10 10 55 56 L1 (56n + 54) L2 (56n + 74) 4- (11 13) installation hole 50 61 2-Rc1/8 ilot exhaust port R side 1004

How to order Spacer type regulator 2 SR T05 C 2 Series 4G/ M4G/ Size Decompression port position C ressure gauge D Check valve 2 ISO size 2 port Ma display lank None T05 port (With limit mark) C Selected port Indicate without a check valve (no symol) for SR- and with a check valve (C) for SR- and SR-. * Note that the direction of the pressure gauge is different for 2-SR--T05C. MN4G/ 4G/ W4G/2 W4G4 4T 4S/0 2-SR--T05 2-SR--T05C Spacer type regulator JIS symol JIS symol 2-SR--T05 a 2-SR--T05C 2-SR--T05C 4S/1 4K/ 55.5 R1 R2 2-SR--T05C 55.5 a R1 R2 3M/0 303 159 53 53 a R1 R2 3/ /M/ N/N/ *0E Individual wiring manifold 5 port pilot operated valve 159 303 1005