General information about underground storage tank (UST) fueling systems in every day language.

Similar documents
Conventional Fueling 11A 11B. 1A Automatic Nozzle

ANNUAL UST SYSTEM INSPECTION CHECKLIST

Underground Storage Tank Annual Compliance Inspection (Revised 1/2015)

40 CFR 63, Subpart CCCCCC

PEI/RP Recommended Practices for the Inspection and Maintenance of UST Systems

(Please type or use black ink)

P.O. Box 435 Saratoga Springs, NY 12866

County of Yolo UNDERGROUND STORAGE TANK PROGRAM INSTALLATION/MODIFICATION/REPAIR APPLICATION

New UST Installation Inspection Checklist

Lorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA

Stage I Vapor Recovery Testing

7. UST Piping Corrosion Protection. NCDENR Division of Waste Management Underground Storage Tank Section

CONTENTS. Foreword...iii. 1. Introduction...1

FINAL UNDERGROUND STORAGE TANK RULE CHANGES. Heather Peters UST Compliance and Technology Unit

Winning Bid US Petroleum Equipment Walts Petroleum Northwest Petroleum Petro-Chemical Systems Kimberly Green Bay Wausau Fond Du Lac

North Carolina Department of Environment and Natural Resources Division of Waste Management Underground Storage Tank Section

Understanding the Colorado Annual Compliance Package. William Holman & Robert Schlegel Inspectors Division of Oil and Public Safety

Underground Oil Storage Tanks Annual Inspection Report

Release Detection Challenges for High Throughput Facilities

Overview of an Underground Storage Tank Inspection

6. Tanks - Leak Detection. NCDENR Division of Waste Management Underground Storage Tank Section

Provide the following information: Site Address: City: Zip: Project Contact Name: Phone No.: ( ) ext.

BUREAU OF UNDERGROUND STORAGE TANK REGULATIONS RELEASE PREVENTION SECTION

FACTS ABOUT: MARYLAND CONTAINMENT SUMP TESTING PROTOCOL WHO CAN PERFORM THE TEST

UST Compliance Assistance Handbook

Application for Permit to Install Underground Storage Tanks (Petroleum or Hazardous Substances) 1. Owner Information 2. Installation Site Information

NCDEQ Underground Storage Tank Section

Stay-put scuff guard helps to protect the dispensers from scratches and the breakaway during a drive-off event

Mark S. Morgan, Regulatory Counsel

FUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System

Management of Underground Storage Tanks

CONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR

Phase-Two Water Detector

Frequent Mishaps and Solutions with Regulated Underground Storage Tanks in Pennsylvania

Inspector's Initials: Tank Owner or Agent Signature: Title: Date:

Tank Filling Systems. for Petroleum Products

Monthly Walkthrough Inspections

(FLB-1000 & FLB-5000)

UST Inspector Reference Handbook

Test Date: 3/30/2018 Order Number: Dear Regulator, Enclosed are the results of recent testing performed at the following facility:

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System

Vapor Tight Overfill Prevention Valves

This handbook is provided as a general guide. assistance/content/storage-tank-compliance

Tank Filling Systems for Petroleum Products

Operating And Maintaining Underground Storage Tank Systems UPDATED Practical Help And Checklists. Printed on Recycled Paper

Compliance Strategies and Benefits. Brian Derge Tanknology Inc. December 6, 2012

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities

PEI/RP Recommended Practices for Installation of Bulk Storage Plants

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

How to Design a Genset Fuel System With Gen Evo (Franklin) ATG

EPA UST Regulations Update May 22, 2018

ADDENDUM NO. #1 ITB # FLORIDA A&M UNIVERSITY (FAMU) FUEL STORAGE TANK INSPECTIONS December 8, 2017

Ohio EPA. Division of Air Pollution Control. Engineering Guide #12

FUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System

Emergency Shear Valves

A. The latest published edition of a reference shall be applicable to this Project unless identified by a specific edition date.

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

Overfill Prevention Valve

LOW LEVEL SUMP TESTING ORIGINS

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

Aboveground Tank Equipment. Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co.

EZ FIT SYSTEM FLEXIBLE CONNECTORS: SERVICE STATION HARDWARE

INSTALLATION INSTRUCTIONS

INSTALLATION, OPERATION, SERVICE & REPAIR PARTS MANUAL FOR

Questions And Answers About The 2015 Underground Storage Tank Regulation As Of May 2017

Bottom Load Adaptors. API Adaptors 891 Series. API Bottom Loading Adaptor L

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

Enhanced Vapor Recovery and In-Station Diagnostics. Presented by: Matthew Schuessler, N Cal Territory Mgr 1

General Issues of Line Leak Detection

How a UST Site May Become Contaminated -- Even When The Leak Detection is Passing

SECTION VEHICLE FUEL DISPENSING EQUIPMENT

PMA INTAKE FILTER SCREEN INSTALLATION GUIDE

Fire & Rescue District

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

NOW UL LISTED. Patented

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

Background. AEM Tier 2 Worksheet Petroleum and Oil Product Storage. Glossary. Agricultural Water Quality Principle:

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

Operational Compliance Closure/Release Response/Corrective Action at Underground Storage Tank Facilities

New Tank Installations. Peter Rollo

Load Table See attached wiring diagrams:

YOUR PETROLEUM STORAGE TANK FACILITY INSPECTION GUIDE

REVISOR CKIWru. t.tz 42, section 692L et seq.; or. A. system holding: (! a mixture of such hazardous waste and other regulated substances; {!

Air Quality Requirements for Gasoline Dispensing

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

Emco Logo on Scuff INSTALLATION INSTRUCTIONS

Pennsylvania DEP: Maintaining UST Compliance and Regulation Updates. NISTM 8 th Annual Pennsylvania Storage Tank Conference May 18, 2017

Storage and Dispensing Locations

UST General Requirements Inspection Checklist

Changing Industry. UST Population (Ohio) Number of Tanks. Year 60,000 50,000 40,000 30,000 20,000 10,000

VEEDER-ROOT COMPANY. Product Knowledge Session. Understanding Line Leak Detection Methods / Test Type / Certifying

How to Stop Spill Buckets from Draining You Dry

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

2016 PRICE LIST TOTAL SYSTEM SOLUTIONS

OPW Installation and Maintenance Instructions OPW Series Primary and Secondary Bucket Replacement Instructions

SB UNDERGROUND AIR VALVE ASSEMBLY INTRODUCTION FEATURES INSTALLATION

Transcription:

What this document contains: General information about underground storage tank (UST) fueling systems in every day language. What you need to know about Texas Commission on Environmental Quality (TCEQ) regulations. Notice of disclaimer: This document A Guide for the New Tank Owner is meant for informational purposes only in plain simple language for the new tank owner that may be useful. Petroleum Solutions, Inc. is in no way held responsible for the contents of this document.

What kinds of tanks are used today? The two most common types of tanks installed today are either Fiberglass Reinforced Plastic (FRP) or Composite (steel tank with external FRP cladding). FRP tanks do not require any kind of corrosion protection (to keep metal from rusting) since they are made of reinforced plastic. Showing one kind of manufactured FRP tanks installed 2

Or they may look like this Showing a different make of FRP tank Composite tanks are steel tanks with an FRP coating. The one most often used composite tank today is the one with 100 mills of FRP coating and do not require corrosion protection. These are called ACT 100. Showing an ACT 100 tank manufactured by WATCO TANKS 3

There is also an ACT 100 tank that has anodes attached for extra corrosion protection for the tank. What kinds of piping are currently used for the UST systems today? FRP single-wall 4

FRP double-wall - a pipe within a pipe that should there be a leak in the inner pipe, it would be contained and a sensor would alert the tank owner of a problem before it gets into the environment). This photo shows double-wall FRP piping Flexible piping- this is actually a double-wall pipe, but is flexible, meaning that it can bend, and is a little easier to install. This shows 1 type of flexible piping, note double wall construction 5

Other Components of the Fuel Tank Note: Today most all the piping systems from the fuel tank to the dispenser are pressurized, since one submerged turbine pump (STP) in the tank can supply fuel to many dispensers for cars or diesel to the big 18-wheelers. Showing STP to supply fuel to the dispensers The STP - The STP also has either a mechanical line leak detector (as in the photo above) or an electronic line leak detector. Both serve the purpose of alerting the tank owner that there is a loss of pressure in the line (possibly a leak). The mechanical line leak detector slows the flow of fuel to 3 gallons per hour when the pressure drops to 10 psi. The electronic line leak detector sounds an alarm and shuts the STP down completely. Below is a photo of an electronic line leak detector. Showing an electronic line leak detector and flexible connector 6

The flexible connector The flexible (flex) connector is connected at both ends of the piping, at the STP and dispenser. The purpose of the flex connector is to allow for some movement of the FRP piping such as during cold weather when the ground contacts to prevent damage to the FRP piping. Note: Flex connectors are not required when flexible piping is used. For ease of installation it is not uncommon for flex connectors to be used with flexible piping as well. Not all STPs are located in a sump as shown above. Some older locations, during a piping upgrade, have the flex connectors installed at both ends of the piping, the flex connector is then isolated from the backfill using a boot or jacket, then it is buried in select backfill with the piping. This shows a flex connector installed at the STP. The yellow covering is to protect the flex connector from corrosion. Spill containment This is sometimes referred to as a spill bucket. It is a bucket like device located at the top of each fill tube where fuel is delivered. This acts as a catchment for spills during product delivery into the underground storage tank (UST). A tight-fill fitting is also located at the top of the fill tube inside the spill containment bucket, which forms a liquid tight seal during fuel deliveries. Showing a 5-gallon spill containment bucket on the fill tube 7

Overfill prevention equipment This is provided at the UST to prevent too much fuel from being delivered into the tank. There are basically two types. Delivery shut-off valve located in the fill tube to physically prevent product flow into the UST when the product level reaches a preset level (95%). Delivery shut-off valve Flow restrictor valve (also called a ball-float valve) is installed in the vent tube and restricts product flow into the UST when the product level reaches a preset level (90%). How it works is by closing off the vent tube, which prevents more fuel from going into the UST. Ball float vent valve (or flow restrictor valve) In the event that an attempt is made to overfill the tank and the delivery shut-off valve or ball float valve shuts off the flow of fuel from the delivery truck, the driver closes the valve at the tanker. Each of these devises does allow the fuel to slowly drain out of the delivery hose. 8

Location of components of a typical UST Pictured below is a typical tank layout to show location major components of a typical UST. STP Submerged turbine pump that delivers fuel to the dispensers ATG Automatic Tank Gauge, this probe goes into the tank to measure fuel level and water levels. The ATG is capable of running a.2-gph tank test for release detection for the tank. This can be set up, if so equipped, to run a test with continuous statistical leak detection (CSLD) or programmed weekly when the store is shut down. Stage I This is connected to the vent line so when a delivery is made, the vapors, rather than venting to the atmosphere would be returned to the fuel delivery tanker. Stage I is required in certain counties both in the non-attainment areas (which also requires Stage II vapor recovery) and the covered attainment counties. This also contains the ball float restrictor valve set at 90% if this is the method to prevent overfills or a little higher if a delivery shut-off valve set at 95% is used. 9

Stage 1 Vapor Recovery Adaptors and Caps Stage I Vapor Recovery Adaptors are installed in spill containment manholes on the vapor recovery riser pipe from an underground gasoline storage tank. They mate with the vapor recovery elbow on the delivery transport truck when recovery of gasoline vapors is required. Stage I Caps are installed on adaptors, when not in use, to prevent gasoline vapors from escaping and to prevent water, dust and debris from entering the tank. This shows the Stage I vapor recovery adaptor & cap Diagram of the Stage I vapor recovery adapter 10

Dispensers & Fuel Islands Diesel fueling for big trucks - From the STP, diesel fuel is then pumped to the fuel islands for fueling 18-wheelers. The STPs for truck fueling are usually larger in size (2 hp-5 hp, sometimes with variable speed to meet demand for fuel at the dispensers) with larger nozzles for filling the large fuel tanks on the trucks. Truck fueling area Fueling for autos and small trucks A typical convenience store fuel island, shown below, has smaller hp STPs, and the dispenser nozzles are smaller than for big trucks. Typical auto fueling area with gas and diesel for smaller trucks 11

Blending systems - Most of the modern fueling systems today at convenience stores for example, have multiple dispensers such as in the photo above. These facilities many times have unleaded, unleaded plus, super and diesel, but only have three tanks (unleaded, super & diesel). To provide unleaded plus to their customers, there is a blending system at the dispenser that that takes unleaded and super, blends them together (commonly 60% unleaded & 40% super) to meet the proper octane for unleaded plus. This blend ratio may very a little bit depending on brand of fuel (like Exxon, Shell, etc.). Shown below are some of the major components of a fueling system. To see more information on the numbered components below, click on the web link below, and then click on OPW system Tour: The OPW web site is: https://www.opw-fc.com/ Dispensing Nozzles Caps & Adaptors Piping Systems Swivels Breakaways Hose Retractors & Hood Assemblies Valves Vapor Line Shear Valves Emergency Shut-off Valves Vents Spill Containers Manholes Tank Bottom Protectors Extractor Fittings Overfill Prevention Valves Tank Probes & Sensors Automatic Tank Gauging & Leak Detection Systems Vapor Recovery Systems Vaporsaver Aboveground Storage Tank Equipment Automated Fuel Control Systems Retail Automation Systems CleanEnergy Fueling Products Eco Tire Inflation Systems Eco Vacuum Systems Island Forms & Pipeguards Vapor Recovery Test Equipment 12

Safety & environmental safeguards at the dispensers Today, most all the UST installations have sumps at the STP, as shown previously and for the dispenser islands. The purpose for this is if there were a leak at the dispenser from the piping or a loose fuel filter, it would be contained in this sump rather than leak into the soil. Showing sumps at the dispenser islands OPW Pipe Guards Pipe guards help protect gasoline dispensers, light poles and other equipment or property from damage. 13

OPW 10 Series Emergency Shut-Off Valves OPW 10 Series Emergency Shut-Off Valves are installed on fuel supply lines beneath dispensers at grade level to minimize hazards associated with collision or fire at the dispenser. If the dispenser is pulled over or dislodged by collision, the top of the valve breaks off at the integral shear groove, activating poppets and shutting off the flow of fuel. Single-Poppet models shut off supply flow, while Double-Poppet models shut off supply as well as prevent release of fuel from the dispenser s internal piping. Dispenser sump with emergency shut-off valve Showing detail of emergency shut-off valve 14

Breakaways These serve the purpose of preventing fuel from spilling on the ground, creating a fire hazard and preventing damage to the dispensers when someone drives off with the fuel nozzle still in their gas tank. Note nozzle still in gas tank, breakaway on other end OPW 66REC Dry Re-connectable Breakaways The OPW 66REC is the first dry re-connectable breakaway for the conventional dispensing market. It is designed to be installed on fuel dispensing hoses, and will separate when subjected to a designated pull force. The dual valves seat automatically, stopping the flow of fuel and limiting any fuel spillage, while protecting the dispensing equipment. When reconnecting the separated halves, the 66REC seals tightly on an O- ring before the poppet stems engage to open the valve. 15

OPW 66 Breakaways The OPW 66 is designed to be installed on fuel dispensing hoses, and will separate when subjected to a designated pull force. The dual valves seat automatically, stopping the flow of fuel and limiting any fuel spillage, while protecting the dispensing equipment. This breakaway is a one-time use only OPW 66SB Swivel Breakaways The OPW 66SB Swivel Breakaway is intended for easy installation at the nozzle inlet. The compact, lightweight design incorporates a 360 swivel rotation at both the male end and middle joint, with a simple and easily re-connectable breakaway on the opposite end. Showing two types of breakaways at a dispenser 16

Emergency Stop As another safety precaution, an Emergency Stop is provided which shuts off fuel to all dispensers. This is used in the event of an emergency, such as a fire at the dispenser or fuel leaking out of a damaged hose or a dispenser that is hit by a vehicle. The Emergency Stop can be located in the store near the cash register, outside or both depending on local fire regulations. An Emergency Stop is required at all fueling operations, and one must be provided outside for locations that are unattended, such as the store closes at night, but allows fuel with card readers. Emergency stop, this one located inside the store. For more information call PSI at 1-800-880-9582, and ask for Bill. 17