AC/DC Regenerative Electronic Load. Ene-phant. Can be used as AC Electronic Load or DC Electronic Load while Regenerating to the Grid.

Similar documents
Flexible configuration by modular type power unit (2kW)

Power Supply And Electronic Load In ONE

Small size High power

Development of the SANUPS P73K Power Conditioner with Peak Power Cut Function

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

ELECTRONIC LOAD CATALOG

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

INVERTER. MECHANICAL DATA Steel with powder paint Dimension (mm) 527 x 228 x 190 Net Weight (kgs) 18 STANDAR. Cont output power at 20ºC. Cos φ 0.

Achieves a high-efficiency conversion of 94% despite being isolated type through digital control

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

REGENERATIVE BATTERY PACK TEST SYSTEM MODEL 17020

PROVA 1011 Solar System Analyzer

Technical Specification SENTINEL PRO

Master Plus kva

OFF-GRID Hybrid (BI-DIRECTIONAL) SOLAR INVERTER SOLAR INVERTER SOLAR UPS

PROGRAMMABLE DC POWER SUPPLY MODEL 62000P SERIES

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

REGENERATIVE BATTERY PACK TEST SYSTEM MODEL MODEL 17040

Datasheet of UBS Series Bidirectional Programmable DC Power Source/Load

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

EFFEKTA Power Supplies

Solar inverter AX-series

Current Automation Catalogue

IT8900 High Performance High Power Programmable DC Electronic Load

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Application. Battery. Public Grid GS HYBRID INVERTER

Liebert. FP 50Z kva

POWER kva

Master Plus kva

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Development of Power Conditioner with a Lithium Ion Battery

MERU Solar Off-Grid Inverters

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Low Profile DC Power Supply with Zero Voltage Soft Switching

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

MODEL REGENERATIVE BATTERY PACK TEST SYSTEM MODEL Regenerative Battery Pack Test System. Key Features. Applications

Unidrive M700 Class leading performance with onboard real-time Ethernet

POWER kva

L300P Inverter Specifications

Development of the Single Phase PV Inverter SANUPS P61A

HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1

MaxPak Plus Analog DC V S Drive

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

MAX310 BEESMART SOLAR MICRO INVERTER TYPE 260. Apparent Power Control (APC) SOLAR PV MODULES UP TO 310 W peak

KEPCO Will Point You In The Right Direction!

Photovoltaics. MPI Hybrid Series

Development of the 3-phase PV Inverter SANUPS P83D

R series solar charger inverter 1000W to 6000W

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

Energy Storage System for Home

MGE TM Galaxy TM 7000 GFC

EAST GROUP COMPANY PROFILE. Energy storage solutions. About us. Grid-connected PV systems. Our Products. Our Team. UPS solutions

Energy Storage System for Home. High Efficiency - Peak efficiency 97.3% Bi-directional DC-DC converter

Analog Input Terminal

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

EPS/ELA-Series User Manual EPS/ELA 250W

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Five Improvements by Power Supply Modules. Switching power supply and power modules. External Dimensions / Pin assignment, SPM Series

Power Conversion System The Best Technology for your photovoltaic and storage system

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

J1000. Compact Inverter Series.

BC-2014 ULTRA COMPACT 4-BAY SMART BATTERY CHARGER (Military Grade)

User Manual 1.5KVA-3KVA INVERTER / CHARGER

TLE Series UPS 160/200/225/250 kw with eboost Technology

APPLICATION NOTE ELECTRONIC LOADS

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

REGENERATIVE BATTERY PACK TEST SYSTEM MODEL MODEL 17020

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

All-in-one Storage Hybrid System

Battery Test Solutions Pack/Module/Cell

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Novel High Efficiency UPS System

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Induction Power Supplies

TECHNICAL DATA SHEET KVA UPS Systemss

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Dynamic DC Emulator Efficient testing of charging technology and power electronics

Phase Modular Finally the benefits of Modular ups are for all

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

Technical Data Sheets

Switching Power Supply

MX1S Matrix Converter

J1000 D E F I 1000 J1000 J1000 J1000 J1000

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

Technical Data Sheets

American Traction Systems. DC Bus Capacitorss. Total. Dual Chopper Module. Dual. Inverter. 750kW. 750kW Generator Module. Module

MAX310 BEESMART SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY Apparent Power Control (APC)

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Transcription:

KEISOKU GIKEN Co., Ltd. / Regenerative Electronic Load Ene-phant NEW!! Single phase 10kW Can be used as Electronic Load or Electronic Load while Regenerating to the Grid. ~ 480Vrms / ~ 680V / 10kW ~ 50kW / 60A ~ 300A http://www.keisoku.co.jp/

/ Regenerative Electronic Load [ & Dual Purposes] + [Regenerative Operation] Ene-phant Various Loading Tests For 1 Inverters and Power Generators 2 3-phase, 3-wire single phase, 3-wire single phase, 2-wire Ene-phant is capable to test those connections. Loading test for High Voltage Power Supplies or Converters High Voltage power supplies(~ 680V) / converters / converters It can be used to test such as High Voltage / converters for vehicles since as high as 680V loading is accomplished. Conforming to the Gridinterconnection 3 4 Code Realized over 90% of regenerative efficiency (at rated load). Utilizing High Efficient Regenerative Method, the power can be reused effectively without wasting as heat. Enephant is a environmentally friendly Electronic Load. Adapted to 29 different capacities and input types with its - operation Multiple units of Single-phase model is connected in parallel for various handling power and wiring type. * For details to p.10. * If you need CE marking, please ask our sales office. Single phase 10kW model It can be used as Load or Load while Regenerating the Loading Power to the Grid. 2 3

Because we care about the future, This is the Electronic Load Expandable up to 50kW They can be paralleled to increase the loading power. Resistor Load to Regenerative Electronic Load Before made by individually. It is necessary to cool down the room temperature when tested with resistive load as they generate heat and increase the temperature. In addition, it has been time consuming if voltage or power measurement are After We realized to recycle over 90% electric power to the grid by this Regenerative Electronic Load. It is beneficial to the user when high power heat run test or aging test is mandatory. With its communication and external remote control features, it is possible to build a automated test system. 10 kw Thermal conversion Power conversion 3-phase 200V *1 Manual operation Automated Ambient temperature Regeneration *Efficiency at the rated load *1 : If you need other voltage, please ask our sales office. Series Regulating Type Electronic Load to Regenerative Electronic Load Before The ordinary electronic loads that are designed with using series regulating power devices and the power consumed and wasted as heat is increasing these days. Method to exchange Electric Energy to Heat Energy. Dropper After With utilizing Regenerative Technology in the electronic load, the heat is converted to the electric power and reused. This can minimize the total-power loss while testing devices. We propose the conservation of energy in those testing from now on. By using regenerative technology, the size became down to 1/3 of ordinary types. 3-phase Switching 200V *1 or Electronic Load to / Electronic Load Before + Heat exchange Regenerative Large size Small size Normally, Electronic Load and Electronic Load are designed differently so the customer needs to prepare both electronic load for their applications. After *1 : If you need other voltage, please ask our sales office. The Ene-phant is designed to be used in environment as well as environment as to cope with various power converting applications. This can minimize the assets and cut the cost. (Single phase model) Loading power 10kW Type of load input. Single phase 2-wire L range:70~340v Loading Voltage H range:140~680v L range: 60A Loading Current (Freq) H range:30w Grid side connection 202V+/- 20V 20kW to 50kW Power Expansion It is adapted to 8 difference loading powers and input types by paralleling 2 or more units. Single models can be used at 3-phase application by the combination of multiple units. It is adapted to single phase, 3-wire system by connecting multiple single phase units. L range:50~240vrms H range:100~480vrms L range: 60Arms H range:30arms (40 ~70Hz) E-Load 2 units for & 1 unit for & Parallel Input (Single phase model) 1~5 sets(max : 50kW) E-Load / Single phase, 2-wire Single phase, 3-wire 1~5 sets((max : 50kW) 2 / 4 sets((max : 40kW) 3 sets((max : 30kW) 4 5

Features and Functions Robust basic features and added value. Down sized by 50%! With High Efficient Switching Technology, the Ene-phant is made compact and light. It is reduced approx 66% of its volume compared with our dropper type 10kW GCC/GCR mode to test Output of Power Generator (Factory option : AX-OP10) These operational modes (GCC and GCR) sink current consistently even the output waveform is distorted when generated by an engine generator. GCC(Generator Constant Current) GCR(Generator Constant Resistant) Common Soft Start Function It delays the current start point from the rising edge of the voltage. It is selected among 1, 2, 5 and 10 seconds in accordance to the characteristics of the DUT. Voltage / Current Voltage Current Down by 66%! electronic load. It requires only 2.2 meter wide when expanded to 50 kw. Time(second) Less space only for 2.2 meters Yellow : Voltage Pink : Current 1 2 5 10 Voltage/Current monitor(option) * The above waveform is a sample waveform in GCR mode. (Yellow: Voltage, Pink: Current) Isolated voltage and current monitors Electronic Load (BNC output) are It can test as high as 680V available as option. As voltage rating of electronic devices are increasing especially 10kW Electronic Load (example) devices for electric vehicles, it is designed and rated as 680V max. Electronic Load Adapted to Single phase input and 3-phase input, single phase model, is capable to test single phase, 2-wire, 3-wire system as well as 3-phase,3-wire system when multiple units are used. Phase lead and lag setting It can simulate Capacitive load (C), Resistive load (R) as well as Inductive load (L) all by itself while it can set the current phase from 0 ~ -1 and 0~+1. The phase lead and the phase lag can be set by the angle as well (-90deg ~ 0 ~ +90deg). 70 ~ 340V 140 ~ 680V Equipped with 5 basic loading modes Communication/External Control Function Various Interfaces USB, RS232C and PLC interfaces are equipped as standard which enable it to control remotely. In addition, GP-IB and LAN (Ethernet) interfaces are available as From high power / converters to Chargers (/ option. converters), Quick-Chargers, High Power Batteries, the following 5 Test voltage up to 480V(Single phase model), single phase model, is equipped with HIGH and LOW switch and enabled to test up to 480V. C-Load Phase lead R-Load L-Load Same phase Phase lag Yellow : Voltage / Pink : Current functions are equipped. CC(Constant Current) CR(Constant Resistant) CV(Constant Voltage) External Control by PLC There are contact input and analog signal (0 ~ 10V) input from PLC for external control. External control is simply possible through PLC without communication or command. Input Single 2-wire Crest Factor Setting CP(Constant Power) MPPT(Maximum Power Point Tracking) Analog(Ai):CC / CP / Phase setting 50 ~ 240Vrms The crest factor can be set from 1.4 to 4.0 in 0.1 increment at the Digital(Di):Load ON / OFF 100 ~ 480Vrms Load mode. Digital(Do):Alarm output This feature is suitable to simulate MPPT mode(hill Climbing Method) Equipped with 3-Basic Load Mode With those loading modes, it can be used to test such as Inverters, Power Conditioners as well as Generators. CC(Constant current) CR(Constant Resistance) CP(Constant Power) such as capacitor input rectifier circuit of switching power supplies. Loading up to 400Hz(Factory option) Standard frequency range is 40Hz to 70Hz but it can be extended to 400Hz for the application of aircraft and ship. The I/V characteristic test of PV panel is possible as it is incorporated MPPT mode. Without using a power conditioner which is incorporated MPPT feature, this electronic load alone can test PV directly for various parameters. I I MP P PMAX PMAX P2 P1 VMP VOC V V Infrared Remote Control (option) Optional infrared remote controller is convenient. This can be used as a numeric key pad to enter such as the current value. VMP2 VMP1 6 7

Features and Functions Operation curve Single-phase 10kW type power curve (model : ) Protective function Protections The following 8 protections are incorporated as to protect the electronic load. Protection OVP(INT) Internal Over Voltage Protection OTP(INT) Internal Over Temperature Protection OCP Over Current Protection OVP Over Voltage Protection LVP Low Voltage Protection OPP Over Power Protection OFP Over Frequency Protection LFP Low Frequency Protection Conforming to JET Standard for Grid Connection It is equipped with Grid Monitor and Protectors which are found in such as power conditioners available in the market. With those monitor system and protectors, it can recycle electronic energy and used safely manner. OCR OVR UVR OFR UFR Single operation detector Grid monitor Over Current Relay Over Voltage Relay Under Voltage Relay Over Frequency Relay Under Frequency Relay Active method Passive method Load voltage(vrms) load LOW range HIGH range 500 450 400 350 300 250 200 150 100 50 0 0 10 20 30 40 50 60 Load current(arms) Wiring diagram Load voltage(v) 700 600 500 400 300 200 100 0 load 0 10 20 30 40 50 60 Load current(a) LOW range HIGH range Emergency Stop and Isolation Emergency Stop switch is on the front panel which enables GATE BLOCK of the power line. There is a transformer which is isolating the electronic load and the grid. Input Voltage Selection of the Grid Side (Factory option) This option enabled to measure the integrated grid power and effective power (Instantaneous power) E load input mode Panel board E load input mode Panel board Emergency SW. Safety design by using transformer to isolate the load and the grid. Grid power measurement (Factory option) Input voltage of 220V and 230V, 3-phase, 4-wire are also available as option. Analog / Digital I/O Communication Emergency stop Analog /Digital I/O Communication Simple dial operation Operation Load Load Gridconnection/Regenerative Function Highly Efficient Regenerative Function Over 90% (at rated loading) of power is reused by the regenerative circuit by our technology which is backed by the bi-directional product development for smart grid. This brings big change on electronic load testing from "Wasting Power as Heat" to " Recycle Electronic Power". A large sized rotary knob is used to set the parameters and functions. With its intuitive manner, the operation is very simple. External dimensions Technology Switching technology Modern control 638 572 inside Analog technology High efficient technology Power regeneration Digital control Non-linear control DSP Grid connection 8 9

Power Expansion With the MASTER- SLAVE feature, it can be expanded up to 50kW for various high power applications. Example-1: and Single-phase, 2-wire input Single-phase model Power 10kW 20kW 30kW 40kW 50kW Configuration M:1=1 set M1+S1=2 sets M1+S2=3 sets M1+S3=4 sets M1+S4=5 sets M=, S= Example-2:Single-phase, 3-wire input Single-phase model Power Configuration 10kW 20kW M1+S1=2 sets 30kW 40kW M1+S3=4 sets 50kW M=, S= Example-3: input Single-phase model Power 10kW 20kW 30kW 40kW 50kW Configuration M1+S2=3 sets M=, S= Single-phase, 2-wire ~ 480Vrms OR ~ 680V Single-phase, 3-wire Electronic load side ~ 480Vrms Electronic load side ~ 480Vrms Electronic load side 400V+/- 40V Grid side (Regenerative and Supply side) (1 ~ 4 units) 20kW ~ 50kW expansion! 400V+/- 40V Grid side (Regenerative and Supply side) (1 or 3 units) 20kW or 40kW expansion! 400V+/- 40V Grid side (Regenerative and Supply side) (2 units) 30kW expansion! Specification Load section-rating Rated power Operating frequency Rated current Rated voltage 0 ~ 10kW, 40 ~ 70Hz (400Hz: Optional) 60Arms/120Apeak 30Arms/60Apeak 60Adc 30Adc 50 ~ 240Vrms 100 ~ 480Vrms 70 ~ 340Vdc 140 ~ 680Vdc Minimum operating voltage 50Vrms 70Vdc 100Vrms 140Vdc 0 ~ 60Arms 0 ~ 30Arms 60Adc 30Adc Resolution 50mA 25mA CC mode Accuracy ± 1% ± 0.2A ± 1% ± 0.2A PF setting range ± 1( mode only) PF resolution 0.01( mode only) Phase setting range ± 90deg( mode only) Phase setting resolution 1deg( mode only) 0.8 ~ 3.4k Ω 3.3 ~ 6.8k Ω CR mode Resolution 10S Accuracy Converted current value ± 1% ± 0.2A CV mode 70 ~ 340V 140 ~ 680V Resolution 0.5V 1V ( mode only) Accuracy ±1%±1V ±1%±2V 0 ~ 10kW CP mode Resolution 20W Accuracy ± 40W MPPT mode Hill Climbing Method mode only ( mode only) CF mode 1.4 ~ 4.0 (Limitation may apply to the peak current) ( mode only) Resolution 0.1 Current limit Low : 0 ~ 120A High : 0 ~ 60A Resolution Low : 0.5A High : 1.0A Voltage limit Low : 70 ~ 340V High : 140 ~ 680V Resolution Low : 0.5V High : 1V Power limit 100 ~ 10kW Resolution 20W Soft-start 1, 2, 5, 10sec Voltage measurement Measurement range 748V (680V+10%) (rms) Current measurement Measurement range 66A (60A+10%) (rms) Peak current measurement Measurement range 132A (120A+10%) Effective power measurement Measurement range 11kW (10kW+10%) Apparent power measurement Measurement range 11kVA (10kVA+10%) PF measurement Measurement range -1 ~ +1 Frequency measurement Measurement range 40 ~ 70Hz Protection Emergency stop, Inside OVP, Inside OHP, OCP, OVP, OPP, OFP, Low frequency, Standalone opertation detect-passive, Standalone operation detect-active, side UVR, OVR, OFR, UFR, OCR Interface Standard RS-232C, USB, LAN (Ethernet) Option GP-IB DI Photo-coupler input External control DO Photo-coupler output (Open collector) AI 0 ~ 10V(CC/CP/phase difference) Monitor output Voltage 10V/1000V/BNC/50 Ω /insulated output (Option) Current 10V/200A/BNC/50 Ω /insulated output Parallel connection 1P2W 1 ~ 4 units 1P3W 2/4 units (/) 3P3W 3 unts Operating area Grid side input:202v ± 20V, 50/60Hz Factory option : 220V / 230V Load side:0arms ~ 60Arms, 0 ~ 10000W/0 ~ 12000W General Power consumption less than 200VA (at standby state) Dimensions(W x H x D) 450mm x 638mm x 700mm Weight 171kg Ambient temperature 0 ~ 50 (Derating necessary over 40 ) Ambient humidity (RH) less than 5 ~ 85%RH (No dew condensation, no corrosive gas) 10 11

http://www.keisoku.co.jp/en/ Application As / electronic load, it can be used in various fields. Output loading test of power conditioner. loading test for generators loading test of high power / converters. MPPT test of PV panels, loading as well as I/V character test. loading test for inverters. Loading test of Fuel Cells. loading test of Chargers and Quick chargers. Discharge test of stationary high power battery system. Regenerated 90% The content of this catalog is generated based on the latest data as of Oct. 2015. Please consult us for the latest specification, price and availability of the product prior to ordering. All brand names, product names and company name are registered trademarks of their respective companies. Information in this document is subject to change without notice. KEISOKU GIKEN Co., Ltd. Power Electronics DIV. SALES DEPT. Hiyoshi operation 4-11-1 Minami-kase, saiwai-ku, Kawasaki-city, Kanagawa-pref. 212-0055 Japan TEL : +81-44-223-7950 FAX : +81-44-223-7960 Osaka office 15-11 Toyotsu-town, Suita-city, Osaka-fu 564-0051, Japan Esaka-Sekisyu building 4F TEL : +81-6-6387-1039 E-mail : PWsales@hq.keisoku.co.jp http://www.keisoku.co.jp/en/ Jan. 2017 issued CP-0126-1701