Magnetic Switches for WEKA Visual Level Indicators Australian Version

Similar documents
IECEx Certificate of Conformity

ATEX LABELLING FOR MOTORS AND GEAR UNITS

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

Ex m Solenoid Operator Type 0519

Operating Instructions for Viscosity Compensated Flow Meter / Monitor. Model: VKM

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Switches in conformity with ATEX directive

Direct-acting 3/2 way plunger valve

Switches in conformity with ATEX directive

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Solenoid Operator 0516 / 1216

MAGNETIC FLOAT SWITCH

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Control and Terminal Box Type A21-**-*****

Endress+Hauser Wetzer GmbH+Co. KG Obere Wank Nesselwang Germany. Field Temperature Transmitter itemp, Types TMT82, TMT84 and TMT85

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Operating Instructions

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Operating Instructions for Paddle Flow Monitor. Model: PSR-..., PSE-...

TECHNICAL BULLETIN. Sandvik MB670 Bolter Miners

PHOENIX CONTACT - 01/2008

Table of contents. Technical informations > ATEX Page Technical informations Page Mechanically operated valves Page 13-06

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Solenoid Operator 0513 / 1213

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Visual Level Indicators (VLI) Economy Line 6

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

The filling level sensors are designed in accordance to the following standards

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

Fans for ATEX EXPLOSIVE ATMOSPHERES

Attachments. Explosion-proof actuators. For opening and closing multileaf dampers installed in potentially explosive atmospheres (ATEX) 09/2017 DE/en

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

YFC. Limit switch. Ex d. 24 operating head types

Magnetic switch For bypass level indicators Model BGU

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Operating Instructions

Technical Data. Dimensions

Terminal Boxes in Stainless Steel SLS**.T

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

VALIADIS S.A. HELLENIC MOTORS

Explosion protected hydraulic products. Product overview industrial and mobile hydraulics

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Operating Instructions

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

Zone 1 Linear Range - Installation Guide

SERIES 54 Inductive Proximity Sensor

Explosion and flame-proof single phase electric motors

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

For mounting on subbase or footprint in accordance with CNOMO recommendation E 06620N Part numbers (and voltages) Voltage max. power consumption U nom

Intrinsically Safe Miniature Solenoid Valves

Limit Switch Type 4747

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Compact pressure switch Model PCS

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

Assembly. Trunk IN + - S U, I U, I. Spur 1

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

High voltage flameproof induction motors The simplest solution for hazardous environments

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Category II 1 G only applies to the Constructional Variants shown in table 15.2 of annex 1.

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

M-0. M-0... series control, monitoring and signalling devices. Ex e

Explosion-Protected Pressure Switches

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

EX-D ENCLOSURES AND DISTRIBUTIONS

Solenoid Valves Type 3963

Magnetic float switch For vertical installation Model FLS

Type 4746 Electric or Pneumatic Limit Switch

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

BFG range BFGC range BFN range

Sensor boxes SRBE Key features and product range overview

Certificate of Conformity

Compact Sheet-Steel Light Fittings Series 6114/1

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Explosion and flame-proof cast iron electric motors

Transcription:

Magnetic Switches for WEKA Visual Level Indicators Australian Version -1- Overview Overview and Selection Guide Installation Information for electrical Reed switches Page 2 3 Type old version Function Media Temp. Electric Data Remarks Page 37160-NN 37160 SPDT -50 C +150 C 230V/1A/60VA/60W Standard 4 37160-NS 37160-NM SPDT SPDT -50 C +150 C 230V/1A/60VA/60W -50 C +150 C 230V/1A/60VA/60W with ss-cable gland with brass cable gland 5 6 Type code Switch Function SPDT 160 37 -N. Version new ss-switches with metric cable gland Execution Standard with PA cable glang with ss-cable gland with brass cable gland N N S M DS_Switches_AUS_2008_01_07.xls revised 01.07.2008 WEKA AG - Schürlistrasse 8 - CH-8344 Bäretswil Phone ++41 (0)43 833 43 43 - Fax ++41 (0)43 833 43 29 - info@weka-ag.ch - www.weka-ag.ch

Installation Instructions Magnetic Switches for WEKA Visual Level Indicators -2- Info Mounting Normal: Valid is the indicated switching function on the type label (float below switch) Installation 180 C opposite of the indication rail with the permitted tolerance according to the tube diameter Cable exit downwards Variation: Each of the following variants leads to a reversion of the indicated switching logic Mounting with cable exit upwards Mounting adjacent to the indication rail DS_Switches_AUS_2008_01_07.xls modification reserved WEKA AG - Schürlistrasse 8 - CH-8344 Bäretswil Phone ++41 (0)43 833 43 43 - Fax ++41 (0)43 833 43 29 - info@weka-ag.ch - www.weka-ag.ch

Contact rating guidelines for Magnetic Switches -3- Info Caution: Read this information before installing level indicators that have magnetic switches. Use of magnetic switches with inappropriate contact ratings can result in damage to the magnetic switches and malfunctioning of level indicators. For Ex rated magnetic switches (311x0-NI / -ND) it is necessary to adhere to the specified limit values of electrical parameters of the circuit. Construction: The key element of a Weka magnetic switch module or sub-assembly is a reed switch. A reed switch consists of two pieces of special flattened wire (the reeds or "paddles") hermetically sealed in a glass capsule. The reed switch is actuated by the magnetic field of the float. The glass capsule is filled with an protective gas that ensures high electrical life expectancy of millions of switching cycles. Contact rating (resistive loads): N/O or N/C switches Changeover switches Typ 31160 31160 -NN -NW -NA -NK -NI -ND -NM -NS -NN -NW -NA 31160 31160 -NK 31160 -NI 31160 -ND 31160 -NM 31160 -NS Contact rating max. 250V max. 1A max. 220VA max. 160W max. 250V max. 1A max. 60VA max. 40W Reed-Switch Magnet S N These values apply only for resistive loads. For inductive loads, see below. Note: None of the specified values may be exceeded. Caution: For many resistive load applications, the electrical circuit can have inductance and / or capacitance. Voltage spikes of 6 to 7 times the normal values can occur when switching off inductive loads. This can sometimes result in the contacts getting welded together, destroying the switch. Examples of inductive loads are transformers, solenoid operated devices (valves, contactors), some types of woundfilament lamps, etc. Protecting magnetic switches used with inductive loads: Figure 1 (D.C.) Reed-Switch inductive load For D.C. applications: + - diode 1N4004 A diode connected across the load coil short circuits the reverse voltage spike that occurs when the supply is switched off, thus protecting the switch contacts. Figure 2 (A.C.) Reed-Switch inductive load For A.C. applications: P 100Ω, ¼W 0,1µF, 600V N A resistor and capacitor in series connected across the switch forms a high impedance path at normal A.C. frequencies. This impedance turns low at high frequencies, diverting spikes currents from the switch. DS_Switches_AUS_2008_01_07.xls modification reserved WEKA AG - Schuerlistrasse 8 - CH-8344 Baeretswil, Switzerland Phone ++41 (0)43 833 43 43 - Fax ++41 (0)43 833 43 29 - info@weka-ag.ch - www.weka-ag.ch

Magnetic switch, change over, bistable with plastic cable gland, for Australia -4- Type 37160-NN External electrical connections Function Magnetic switch for WEKA Visual Level Indicators bistable The switch module is attached to the float chamber, diametrically opposite the indication rail, with cable-exit below (see data sheet 20010501). The float magnet activates the reed contact when the liquid in the float chamber reaches that level. The switching logic is reversible by installing the switch N S module adjacent to the indication rail, or alternatively by inverting the switch module with cable-exit upwards. Please refer to the safety guidelines. Product code 37160-NN/3 with 3m cable 37160-NN/5 with 5m cable 37160-NN/10 with 10m cable Installed opposite the indication rail 37160-NN/20 with 20m cable Cable exit downwards Switching logic Change over, bistable BN GY BK Dimensions Contact rating max. 230V max. 1A max. 60VA max. 60W Enclosure IP68-5bar (EN 60529) Material Housing Stainless steel 316 /316L Cable gland PA6, grey, 3 8mm Seal Perbunan (NBR) Cable LiYY, grey, Ø 5.8mm Shield not shielded Cable cores 3 x 0,75mm² Core colours BK, GY, BN Tag label Polyester, yellow, black writing Operating conditions Media temperature -50 C +150 C Ambient temperature -20 C +80 C Media temperature Ambient temperature Temperature of liquid within the float chamber Temperature of air around the magnetic switch Fixation If ordered together with a VLI fixation is included in the delivery If fixation is ordered separately please indicate tube diameter for tube diameter 30 40mm Article no. 80648 for tube diameter 40 57mm and 57 80mm Article no. 84043 Remarks The switch is maintenance free. DS_Switches_AUS_2008_01_07.xls revised 20.04.07, Ot WEKA AG - Schürlistrasse 8 - CH-8344 Bäretswil Phone +41 (0)43 833 43 43 - Fax +41 (0)43 833 43 29 - info@weka-ag.ch - www.weka-ag.ch

Magnetic switch, change over, bistable for highest chemical resistance, for Australia -5- Type 37160-NS External electrical connections Function Magnetic switch for WEKA Visual Level Indicators bistable The switch module is attached to the float chamber, diametrically opposite the indication rail, with cable-exit below (see data sheet 20010501). The float magnet activates the reed contact when the liquid in the float chamber reaches that level. The switching logic is reversible by installing the switch N S module adjacent to the indication rail, or alternatively by inverting the switch module with cable-exit upwards. Please refer to the safety guidelines. Product code 37160-NS/3 with 3m cable 37160-NS/5 with 5m cable 37160-NS/10 with 10m cable Installed opposite the indication rail 37160-NS/20 with 20m cable Cable exit downwards Switching logic Change over, bistable BN GY BK Dimensions Contact rating max. 230V max. 1A max. 60VA max. 60W Enclosure IP68 - (EN 60529) Material Housing Stainless steel 316 /316L Cable gland Stainless steel, 1.4436, 5 10mm Seal FPM Cable LiYY, grey, Ø 5.8mm Shield not shielded Cable cores 3 x 0,75mm² Core colours BK, GY, BN Tag label Polyester, silver, black writing Operating conditions Media temperature -50 C +150 C Ambient temperature -20 C +80 C Media temperature Ambient temperature Temperature of liquid within the float chamber Temperature of air around the magnetic switch Fixation If ordered together with a VLI fixation is included in the delivery If fixation is ordered separately please indicate tube diameter for tube diameter 30 40mm Article no. 80648 for tube diameter 40 57mm and 57 80mm Article no. 84043 Remarks The switch is maintenance free. DS_Switches_AUS_2008_01_07.xls revised 20.04.07, Ot WEKA AG - Schürlistrasse 8 - CH-8344 Bäretswil Phone ++41 (0)43 833 43 43 - Fax ++41 (0)43 833 43 29 - info@weka-ag.ch - www.weka-ag.ch

Magnetic switch, change over, bistable with brass cable gland, for Australia -6- Type 37160-NM External electrical connections Function Magnetic switch for WEKA Visual Level Indicators bistable The switch module is attached to the float chamber, diametrically opposite the indication rail, with cable-exit below (see data sheet 20010501). The float magnet activates the reed contact when the liquid in the float chamber reaches that level. The switching logic is reversible by installing the switch N S module adjacent to the indication rail, or alternatively by inverting the switch module with cable-exit upwards. Please refer to the safety guidelines. Product code 37160-NM/3 with 3m cable 37160-NM/5 with 5m cable 37160-NM/10 with 10m cable Installed opposite the indication rail 37160-NM/20 with 20m cable Cable exit downwards Switching logic Change over, bistable BN GY BK Dimensions Contact rating max. 230V max. 1A max. 60VA max. 60W Enclosure IP68-5bar (EN 60529) Material Housing Stainless steel 316 /316L Cable gland Brass, nickel-plated, 5 10mm Seal Perbunan (NBR) Cable LiYY, grey, Ø 5.8mm Shield not shielded Cable cores 3 x 0,75mm² Core colours BK, GY, BN Tag label Polyester, silver, black writing Operating conditions Media temperature -50 C +150 C Ambient temperature -20 C +80 C Media temperature Ambient temperature Temperature of liquid within the float chamber Temperature of air around the magnetic switch Fixation If ordered together with a VLI fixation is included in the delivery If fixation is ordered separately please indicate tube diameter for tube diameter 30 40mm Article no. 80648 for tube diameter 40 57mm and 57 80mm Article no. 84043 Remarks The switch is maintenance free. DS_Switches_AUS_2008_01_07.xls revised 20.04.07, Ot WEKA AG - Schürlistrasse 8 - CH-8344 Bäretswil Phone ++41 (0)43 833 43 43 - Fax ++41 (0)43 833 43 29 - info@weka-ag.ch - www.weka-ag.ch

Magnetic switch, ON/OFF, bistable, Intrinsically safe II 2 G Ex ia IIC T6 Gb / II 2 D Ex iad IIIC T85 C Db Type -NI -18- External electrical connections bi-stable N S Instruction manual Function Magnetic switch for WEKA- VLI The magnetic switch is mounted outside of the float chamber opposite to the indication rail. The switching logic can be reversed by inverting the switch module with cable-exit upwards or by installing the switch module adjacent to the indication rail where technically authorised (see datasheet 20010501). The magnet inside the float activates the reed switch, when the liquid in the float chamber reaches that level. Please refer to the safety guidelines. Product code (standard) -NI/3 with 3m cable -NI/5 with 5m cable -NI/10 with 10m cable Installed opposite to indication rail -NI/20 with 20m cable Cable exit downwards Switching logic on/off, bi-stable WH BN Dimensions Electrical data: Only for connection to certified intrinsically safe circuits with the following maximum values: U i = 250V I i = 1.3A The effective internal capacitance and inductance are negligibly small. Additionally the maximum effective capacitance and inductance of the firmly connected cable have to be concidered with Ci=110pF/m und Li=0.7µH/m. Enclosure IP68-10bar (EN 60529) Hysteresis = 10 Material Housing Stainless steel 316 /316L Cable gland PA6: blue, 4 8mm Seal Perbunan (NBR) Cable LiYCY/EB: blue, Ø 5.8mm Shield shielded, but not connected Cable cores 2 x 0,75mm² Core colours WH, BN Type label Polyester: silver, black printing Operating conditions Media temperature Ambient temperature Temperature class -50 C +150 C -20 C +65 C T3 (200 C) -50 C +135 C -20 C +65 C T4 (135 C) -50 C +100 C -20 C +65 C T5 (100 C) -50 C +85 C -20 C +65 C T6 (85 C) Media temperature Temperature of liquid within the float chamber Ambient temperature Temperature of air around the magnetic switch Temperature class Specified max. surface temperature Grounding A connection to protection ground is only guaranteed if both fastening clamps are used to fix the magnetic switch to the float chamber. If the float chamber does not have electrical continuity to protective ground, or if only one fastening clamp can be used for fixing the switch, the connection must be made with the foreseen screw clamp of the switch. Fixation When ordering level indicators with switches, hose clamps are included. When ordering switches as spare parts, hose clamps are never included and must be ordered seperately. Only genuine parts have to be used as spare parts. In case of ordering hose clamps pipe size must be indicated: For pipe diameter 30 40mm Article no. 80648 For pipe diameter 40 57mm and 57 80mm Article no. 84043 Note EC- Type-Examination Certificate resp. IECEx CoC has additionally to be considered. www.weka-ag.ch The cable must be durably installed. This device is maintenance free and repair work is prohibited. For use in areas with explosive dust consider the max. media temperature instead of max. surface temperature. Only to use in combination with thermal non-insulated float chamber. Spesenabrechnung_2010_07_0 07.09.2010/Ot WEKA AG - Schürlistrasse 8 - CH-8344 Bäretswil Subject to change without notice Phone +41 43 833 43 43 - Fax +41 43 833 43 29 - info@weka-ag.ch - www.weka-ag.ch

Magnetic switch, Change-over, bistable, Intrinsically safe II 2 G Ex ia IIC T6 Gb / II 2 D Ex iad IIIC T85 C Db Type 31160-NI -19- External electrical connections bistable N S Instruction manual Function Magnetic switch for WEKA- VLI The magnetic switch is mounted outside of the float chamber opposite to the indication rail. The switching logic can be reversed by inverting the switch module with cable-exit upwards or by installing the switch module adjacent to the indication rail where technically authorised (see datasheet 20010501). The magnet inside the float activates the reed switch, when the liquid in the float chamber reaches that level. Please refer to the safety guidelines. Product code (standard) 31160-NI/3 with 3m cable 31160-NI/5 with 5m cable 31160-NI/10 with 10m cable Installed opposite to indication rail 31160-NI/20 with 20m cable Cable exit downwards Switching logic Change-over, bistable WH BN GN Dimensions Electrical data: Only for connection to certified intrinsically safe circuits with the following maximum values: U i = 230V I i = 1.0A The effective internal capacitance and inductance are negligibly small. Additionally the maximum effective capacitance and inductance of the firmly connected cable have to be concidered with Ci=110pF/m und Li=0.7µH/m. Enclosure IP68-10bar (EN 60529) Hysteresis = 10 Material Housing Stainless steel 316 /316L Cable gland PA6: blue, 4 8mm Seal Perbunan (NBR) Cable LiYCY/EB: blue, Ø 6.2mm Shield shielded, but not connected Cable cores 3 x 0,75mm² Core colours WH, BN, GN Type label Polyester: silver, black printing Operating conditions Media temperature Ambient temperature Temperature class -50 C +150 C -20 C +65 C T3 (200 C) -50 C +135 C -20 C +65 C T4 (135 C) -50 C +100 C -20 C +65 C T5 (100 C) -50 C +85 C -20 C +65 C T6 (85 C) Media temperature Temperature of liquid within the float chamber Ambient temperature Temperature of air around the magnetic switch Temperature class Specified max. surface temperature Grounding A connection to protection ground is only guaranteed if both fastening clamps are used to fix the magnetic switch to the float chamber. If the float chamber does not have electrical continuity to protective ground, or if only one fastening clamp can be used for fixing the switch, the connection must be made with the foreseen screw clamp of the switch. Fixation When ordering level indicators with switches, hose clamps are included. When ordering switches as spare parts, hose clamps are never included and must be ordered seperately. Only genuine parts have to be used as spare parts. In case of ordering hose clamps pipe size must be indicated: For pipe diameter 30 40mm Article no. 80648 For pipe diameter 40 57mm and 57 80mm Article no. 84043 Note EC- Type-Examination Certificate resp. IECEx CoC has additionally to be considered. www.weka-ag.ch The cable must be durably installed. This device is maintenance free and repair work is prohibited. For use in areas with explosive dust consider the max. media temperature instead of max. surface temperature. Only to use in combination with thermal non-insulated float chamber. Spesenabrechnung_2010_07_0 07.09.2010/Ot WEKA AG - Schürlistrasse 8 - CH-8344 Bäretswil Subject to change without notice Phone +41 43 833 43 43 - Fax +41 43 833 43 29 - info@weka-ag.ch - www.weka-ag.ch

Magnetic switch, Change-over, bistable, Flameproof enclosure II 2GD T85 C Ex d IIC T6 ZELM 03 ATEX 0190 Type 31160-ND External electrical connections Function Magnetic switch for WEKA Visual Level Indicators bistable The magnetic switch is mounted outside of the float chamber opposite to the indication rail. The switching logic can be reversed by inverting the switch module with cable-exit upwards or by installing the switch module adjacent to the indication rail (see datasheet 20010501). N S The magnet inside the float activates the reed switch, when the liquid in the float chamber reaches that level. -21- Please refer to the safety guidelines. Product code (standard) 31160-ND/3 with 3m cable 31160-ND/5 with 5m cable 31160-ND/10 with 10m cable Installed opposite to indication rail 31160-ND/20 with 20m cable Cable exit downwards Switching logic Change-over, bistable BU BK BN GN / Dimensions Contact rating max. 230V max. 1A max. 60VA max. 60W Enclosure IP68-10bar (EN 60529) Hysteresis = 10 Material Housing Stainless steel 316 /316L Cable gland Brass: nickel-plated, 7 9mm Seal Perbunan (NBR) Cable PVC: grey, Ø 8.2mm,largely resistant to oils/petroleum products Shield Cable cores Core colours Type label Operating conditions Media temperature not shielded 4 x 0,75mm² (3 + PE) BN, BU, BK, GN/YE Polyester: silver, black printing Ambient temperature Temperature class -50 C +150 C -20 C +80 C T3 (200 C) -50 C +135 C -20 C +80 C T4 (135 C) -50 C +100 C -20 C +80 C T5 (100 C) -50 C +85 C -20 C +80 C T6 (85 C) Media temperature Temperature of liquid within the float chamber Ambient temperature Temperature of air around the magnetic switch Temperature class Specified max. surface temperature Grounding A connection to protection ground is only guaranteed if both fastening clamps are used to fix the magnetic switch to the float chamber. If the float chamber does not have electrical continuity to protective ground, or if only one fastening clamp can be used for fixing the switch, the connection must be made with the foreseen screw clamp of the switch. Fixation When ordering level indicators with switches, hose clamps are included. When ordering switches as spare parts, hose clamps are never included and must be ordered seperately. In case of ordering hose clamps pipe size must be indicated: For pipe diameter 30 40mm Article no. 80648 For pipe diameter 40 57mm and 57 80mm Article no. 84043 Note The relevant certificates are available at www.weka-ag.ch The cable must be durably installed. This device is maintenancefree and repair work is prohibited. For use in areas with explosive dust consider the max. media temperature instead of max. surface temperature. DS_Magnetic_Switches_E_2009_09_16 Subject to change without notice WEKA AG - Schürlistrasse 8 - CH-8344 Bäretswil Telefon +41 43 833 43 43 - Fax +41 43 833 43 29 - info@weka-ag.ch - www.weka-ag.ch

Classification of Hazardous Zones and Marking of Flameproof enclosures Equipment -29- Inflammable Material Classification and Marking of Flameproof enclosures Apparatus Incidence of inflammable material in Ex zone. Explosive media Hazardous zones Marking of Flameproof enclosures equipment Apparatus group Apparatus category Apparatus Group Classification of Gases, Aerosols, Vapors Examples of inflammable Gases [Note:This is only a partial list of inflammable gases/vapors] Gases Vapor Steam Present continuously, frequently, or over extended periods of time Present occasionally Presence unlikely or rare and only for brief periods of time Zone 0 Zone 1 Zone 2 II II II 1G 2G 3G IIA IIB IIC Ammonia, Methane, Ethane, Propane Town gas, Acrylonitrile Ethyl alcohol, Cyclohexane, N-butane Ethylene, Ethylene oxide Benzene, Diesel, Furnace oil, N-hexane Ethyl glycol, Hydrogen sulfide Acetaldehyde Ethyl ether Hydrogen Acetylene Carbon disulfide Inflamm-able dust cloud Present continuously, frequently, or over extended periods of time Present occasionally Presence unlikely or rare, and only for brief periods of time Zone 20 Zone 21 Zone 22 II II II 1D 2D 3D Temperature Classes The temperature class specifies the maximum surface temperature of the apparatus. The ignition temperature must be higher than the maximum surface temperature Methane - - Mines Mines I I M1 M2 < 85 C T6 < 100 C T5 < 135 C T4 < 200 C T3 < 300 C T2 < 450 C T1 Example: 0820 II 2G Ex d IIC T6 ZELM 03 ATEX0168 - Marking - including the reference number of the certification authority (notified body) An explosion inside the enclosure is prevented from spreading outside The energy in the electrical circuit in the hazardous zone is limited by design, thus preventing dangerous sparks and/or ignition temperatures Flameproof enclosures Intrinsically safe Ex d Ex i Zone 1 or 2 Zones 0, 1 and 2: Ex ia Zones 1 and 2: Ex ib IEC EN 60079-1 (Gas) IEC EN 61241-1 (Dust) IEC EN 60079-11 (Gas) IEC EN 61241-11 (Dust) ATEX marking and certificate number Year of certification Abbreviated name of certification authority (notified body) The equipment may be used without restriction The equipment may be used subject to specific conditions The equipment is an "Ex" component with partcertification and therefore cannot be used as standalone. - X U Certificate reference number Principle of protection [All methods of ignition protection are not indicated here, for simplification] Means of protection Marking [Omitted here: Ex o, Ex p, Ex q, Ex e, Ex m, Ex n] Symbol Zone compatibility Standard Traceability reference Conditions Marking Authority Methods of Protection and Apparatus Marking Certificate Additional information Note: - Per ATEX guidelines, WEKA Level Indicators and accessories are components only, as they function only together with other equipment. - An electrical device can be used in a temperature class lower than its certification, if operating conditions allow this. - "Ex" components and attached metallic equipment must be connected to a common electrical ground point. DS_Transmitter_E_2009_04_23.xls 23.04.09/Ot WEKA AG - Schürlistrasse 8 - CH-8344 Bäretswil - Switzerland Modifications reserved Phone +41 43 833 43 43 - Fax +41 43 833 43 29 - info@weka-ag.ch - www.weka-ag.ch

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx ZLM 10.0003issue No.:0 Certificate history: Current Date of Issue: 2010-12-15 Page 1 of 3 Applicant: Electrical Apparatus: Optional accessory: Type of Protection: Marking: Weka AG Schuerlistr.8 8344 Baeretswil Switzerland magnetic switch type -NI/* and type 31160-NI/* Intrinsic Safety Ex ia IIC T6 Gb Ex iad IIIC T85 C Db Approved for issue on behalf of the IECEx Certification Body: Position: Dipl.-Ing. Harald Zelm Head of Certification Body 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: ZELM Explosionsschutz GmbH Siekgraben 56 D-38124 Braunschweig Germany http://iecex.iec.ch/iecex/iecexweb.nsf/uid/1d93e057ac2e8f17c12577bd002ae0b0?opendocument

Certificate No.: IECEx ZLM 10.0003 IECEx Certificate of Conformity Date of Issue: 2010-12-15 Issue No.: 0 Page 2 of 3 Manufacturer: Weka AG Schuerlistr. 8 8344 Baeretswil Switzerland Manufacturing location(s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2007-10 Edition: 5 IEC 60079-11 : 2006 Edition: 5 IEC 61241-11 : 2005 Edition: 1 Explosive atmospheres - Part 0:Equipment - General requirements Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" Electrical apparatus for use in the pressence of combustible dusts - Part 11: Protection by intrinsic safety 'id' This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in Test Report: DE/ZLM/ExTR10.0003/00 Quality Assessment Report: DE/ZLM/QAR09.0001/00 http://iecex.iec.ch/iecex/iecexweb.nsf/uid/1d93e057ac2e8f17c12577bd002ae0b0?opendocument

Certificate No.: IECEx ZLM 10.0003 IECEx Certificate of Conformity Date of Issue: 2010-12-15 Issue No.: 0 Page 3 of 3 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: The magnetic switches type -NI/* and type 31160-NI/* are for the generation of a signal at a level change of media. Therefore the switch will be used together with a visual level indicator. The type -NI/* uses an on/off switch, the type 31160-NI/* uses a changeover switch. The star (*) indicates the length in meter of the permanently connected cable. CONDITIONS OF CERTIFICATION: NO Annexe: IECExZLM100003-annex.pdf http://iecex.iec.ch/iecex/iecexweb.nsf/uid/1d93e057ac2e8f17c12577bd002ae0b0?opendocument