VAV Terminal Unit Control Package

Similar documents
Pneumatic Controls. Pneumatic Controls Sections

TK-6024, TK-6124, TK-8024, TK-8124

Electronic Controls. Electronic Controls Sections

General Information... 2

Fan Powered Low Profile Variable Volume Terminal Units

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE RESOURCE DOCUMENTS PAGE #

Powers TM Controls SW 141 Differential Static Airflow Switches

HOW TO SPECIFY SDV UNITS

Terms. Direct Acting (DA) The action of a controller that increases its branch line pressure as the controlled variable increases

Hoffman Controls. Installation & Operating Instructions. General. Installation. Determining Damper Shaft Rotation. Stop Pin Installation

VEP-11/12/21/22 Series

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

POWERS CONTROL RC 195 Multiple Input Receiver- Controller

SECTION AIR TERMINAL UNITS

POWERS TM CONTROLS LC Pneumatic Damper Actuator

IOM 002 Effective 12/17 A I R D I S T R I B U T I O N M O D E L Q S T M O D E L Q P T M O D E L E S T

AIR FLOW SOLUTIONS. MODEL QST Quiet, Series (Continuous) Flow VAV Terminal Unit. MODEL QPT Quiet, Parallel (Intermittent) Flow VAV Terminal Unit

ATP-2040 Electric Damper Actuator/Transmitter

RETROFIT TERMINAL UNITS

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

R-317 Air Flow Controller

SINGLE DUCT TERMINAL UNITS

R81EAA-2 Economizer Circuit Board

Powers Controls RL 147 Positioning Relay

Variable Air Volume Dampers

N-1001 Economizer Logic Network

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE #

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2

OE326-23I-OR VAV/Zone Controller

Damper Actuator Installation

Distributed By: M&M Control Service, Inc Product Product Code Technical Instructions Page #

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

T100A,F,M Controllers

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

V-9502 Series Pneumatic Valve Actuator Positioners

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

AK Application. Features. Applicable Literature. Positive Positioner Pneumatic Relay General Instructions

SERIES 700 ANALOG ELECTRONIC CONTROLS

Powers TM Controls RL 243 SW Switching Relay

IAQ. ROUND DUCT RETROFIT Model ARR

Auxiliary Equipment. Table of Contents. Auxiliary Equipment H-1. Product Product Code Technical Instructions Page #

C-5230 Pneumatic Signal Limiter

Powers Controls TT 184 Temperature Transmitters

P10 Series Low Range Pressure Controls

Laboratory Room Controller

Variable Air Volume (VAV) Pressure Independent Control

LDV / LDVQ 5000 AIR VOLUME CONTROL VALVE INSTALLATION MANUAL. Date: 02 / 10 Reference # : F-36. w w w. p r i c e - h v a c. c o m

RA-2000 Airflow Measuring System

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev.

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

RD-2000 Round Control Dampers

POWERS Controls No. 4 Pneumatic Damper Actuator

P70 Series MICRO-SET TM Pressure Controls for Refrigeration and Air Conditioning, 4-Wire, 2-Circuit Contact Block

R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators

BAS Construction Checklist

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

T PI Receiver-Controller

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

Honeywell MP516A UNIT VENTILATOR DAMPER OPERATOR GENERAL DESCRIPTION APPLICATION SPECIFICATIONS OPERATION

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator.

Air Pressure Sensing Switch with Adjustable Set Point Range. Dimensions in Inches (Millimeters)

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE

SINGLE DUCT AIR TERMINAL UNITS

LF Series Spring Return Direct Coupled Actuator

Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS. Features DESCRIPTION

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN Rev.

Flare Valves 1/2 inch 2-Way and 3-Way

System 350 P352AB Electronic Pressure Control Series

D-4070 Two Stage Pneumatic Actuator

University of Delaware

Controllers & Transmitters

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Model 116 DPI Switch Installation and Operating Instructions

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

SINGLE DUCT AIR TERMINAL UNITS

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

PNEUMATIC CONTROL SYSTEMS DESIGN AND CONSTRUCTION STANDARD PART 1 - GENERAL. A. Codes and Standards that are Standard at the University:

TM-9100 Series Room Command Module

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Single-Duct. Table of Contents. Model Number Description SD 2 3. Service Model Number Description SD 4. Selection Procedure SD 5 6

EP-8000 Series Electro-Pneumatic Transducers

POWERS TM CONTROLS SW 786 Selector Switch

A91 Series Thermistor Temperature Sensors For Duct, Immersion and Space Sensing

Laboratory Exhaust Air Terminal

VAV TERMINAL BOXES TYPE: BA BT

FAN POWERED TERMINAL UNITS

IAQ. Model AVC. SINGLE DUCT VAV Model AVC

TC-200 Series. Application. Features. Applicable Literature. Single Bulb Thermostats General Instructions

Laboratory Room Single Duct Supply Air Terminal

Controls Analog. Options. Single-Duct Terminal Unit (VCCF, VCWF, and VCEF)

M9216 Series Electric Spring Return Actuators

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Fan - Powered Terminal Unit Series Flow

Direct-Coupled ControlSet Actuators (120/180/320 in-lbs.) Installation Guide 2-7/16"

Application Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification

Transcription:

VAV Terminal Unit Control Package Model CP-133-STK Pneumatic Pressure Independent, VAV Cooling, Constant Volume Heating at Min CFM set point. This actuator/controller will accommodate Direct or Reverse acting T-Stats. This control package may be applied to Single Duct VAV terminal units (Model SDV) or Fan Powered Box Terminal Units (Model NRFHE) Notes: 1. This control Package is provided as loose components for field installation and wiring. 2. Pneumatic T-Stat NOT provided as part of this package. 3. PE switches or Heat control valves NOT provided as part of this package. 4. Flow Cross Velocity Sensor NOT provided as part of this package. 5. Technical Data for the CTC-1611 pneumatic T-Stat is available, See IOM bulletin for VAV Terminal Units Accessories. 6. Technical Data for the Flow Cross Sensor is available, See IOM bulletin for T&B Model SDV Terminal units. Piping Diagram.. 2 Control Sequence Primary Valve 3 Piping/Wiring Fan Box application.. 4 Component Data sheets and IOM s 5-8 Page 1 of 8

Tuttle & BaileyR CONTROL PACKAGE M MAIN AIR SUPPLY 20 PSI T RELAY THERMOSTAT DIRECT ACTING (BY OTHERS) (ALTERNATE) BLEED THERMOSTAT DIRECT ACTING (BY OTHERS) M T R RESTRICTOR BY CONTROLS CONTRACTOR 3 AIR FLOW AIR FLOW SENSOR N.O. H.W. VALVE OR N.C. P.E. SWITCH HI LOW A B (BY OTHERS) WHITE RED GREEN T YELLOW B H L RESET START LO STAT P BLUE M NO DAMPER NC INCR INCR HI STAT P RESET SPAN G CSC-3011 N.O. DAMPER 2 DAMPER ACTUATOR 1 RESET CONTROLLER 8-13 RESET RANGE (8=MIN, 13=MAX) FACTORY PIPING FIELD PIPING NOTES: 1. DAMPER FAILS NORMALLY OPEN. 2. MAIN AIR SUPPLY CONSUMPTION IS 0.017 SCFM AT 20 PSIG. 3. PART NUMBER DEPENDENT ON UNIT SIZE. SUBMITTED BY: JOB NAME: LOCATION: ARCHITECT: ENGINEER: CONTRACTOR: ITEM PART NO 1 2 3 10065001 10058501 NOTE 3 DESCRIPTION KMC CONTROLLER CSC-3011 KMC DAMPER ACTUATOR MCP-8031 R FLO-CROSS SENSOR REV LEVEL: A DATE: 9/01 SDV SINGLE DUCT VAV PNEUMATIC CONTROLS Direct Acting - Normally Open DWG NO: 1202 WWW.TUTTLEANDBAILEY.COM Page 2 of 8 1202-9/01

Tuttle & BaileyR CONTROL PACKAGE 1202 CONTROL DIAGRAM MAX. AIR FLOW MIN. REHEAT H.W. ELECT. 0 3 5 8 10 13 THERMOSTAT BRANCH PRESSURE - PSIG PRIMARY AIR FLOW SEQUENCE OF OPERATION 1.) COOLING ONLY Airflow is at minimum when thermostat branch pressure is below 8 PSIG. On a rise in room temperature, the thermostat branch pressure increases to 13 PSIG and air flow increases to maximum. The reverse will occur, with a drop in room temperature. 2.) COOLING WITH REHEAT Primary air flow is at minimum and the reheat is energized when thermostat branch pressure is between 3-8 PSIG. As room temperature increase reheat is sequenced off. With a further rise in room temperature the thermostat branch pressure increases to 13 PSIG and primary airflow increases to maximum. The Reverse will occur with a drop in room temperature. NOTE: Optional reheat control requires a normally open hot water valve or normally closed P/E switch. 3.) Damper fails open with loss of pneumatic air. WWW.TUTTLEANDBAILEY.COM 1202P2-9/01 Page 3 of 8

Page 4 of 8

CSC 3000 Series Volume Reset Controller Description The KMC CSC-3000 Series Volume Reset Controllers are designed for use on heating or cooling systems with normally open or normally closed VAV terminal units. The CSC-3000s are sub-master air velocity controllers with adjustable minimum and maximum velocity limits. A master controller, typically a room thermostat, resets the CSC s velocity set point between minimum and maximum velocity setpoints. CSC-3000s universal design is intended for new or replacement applications that call for direct or reverse acting reset on normally open, or normally closed, VAV terminal units. The CSC features field adjustable reset start point and span settings for any application. Features Available in 0 to 1" and 0 to 2" wc ranges Direct or reverse acting reset (normally open or normally closed damper settings) Field adjustable reset start point and span Application CSC-3000s are used in applications that require normally open, or normally closed, VAV terminal units using direct or reverse acting thermostats.!caution Pneumatic devices MUST operate with CLEAN, DRY, control air. Any other medium will result in the device s eventual failure. Models CSC 3011 10 CSC 3021 10 CSC 3023 10 CSC 3025 10 CSC 3016 10 0 to1" range; 8 psig start; with bracket 0 to1" range; 3 psig start; with bracket 0 to1" range; 10 psig start; with bracket 0 to 2" range; 8 psig start; with bracket (high flow) 0 to 2" range; 8 psig start; with bracket Accessories/Repair Parts HFO-0006 In-line control-air filter HMO-4508 Mounting bracket SSS-1002 One sensing point; 3-5/32 (80 mm) length SSS-1003 Two sensing points; 5-13/32 (137 mm) length SSS-1004 Three sensing points; 7-21/32 (195 mm) length SSS-1005 Four sensing points; 9-29/32 (252 mm) length Specifications and design subject to change without notice. Page 5 of 8

Details All dimensions in inches (mm). Specifications 1" Range Differential Pressure 0 to 1" wg (249 Pa) Minimum Set point 0 to 1" wg (249 Pa) Maximum Set point Minimum to 1" wg 2" Range Differential Pressure 0 to 2" wg (498 Pa) Minimum Set point 0 to 2" wg (498 Pa) Maximum Set point Minimum to 2" wg Reset Span Factory set @ 5 psig(35 kpa), field adjustable 0 to 10 psig (69 kpa) Reset Start Point Factory set @ 8 psig ( 55 kpa), field adjustable 0 to 10 psig (69 kpa) Output Sensitivity 1" Models 5 psi/.02" wg (35 kpa/5 Pa) 2" Models 5 psi/.04" wg (35 kpa/10 Pa) Damper Action Factory set @ N.O., adjustable for N.C. or N.O. Thermostat Action Direct or reverse action Main Air Pressure 15 to 30 psig (103 to 207 kpa) Max. Signal Pressure 6" wg (1493 Pa) applied to either port (H or L) Air Consumption CSC-3011/21/23/16 28.8 scim @ 20 psig (7.87 ml/s @ 138 kpa) CSC-3025-10 46.1 scim @ 20 psig (12.59 ml/s @ 138 kpa) Temperature Limits Operating 40 to 120 F (4 to 49 C) Shipping -40 to 140 F (-40 to 60 C) Material Weight ABS, UL Flame Class 94 HB 11 oz. (312 grams) KMC Controls, Inc. 19476 Industrial Drive New Paris, IN 46553 574.831.5250 www.kmccontrols.com 2003 KMC Controls Inc. 213-035-01A Page 6 of 8

Mounting Installation Guide Variable Volume Controllers CSC-3000 Series The CSC-3000 Series are position sensitive. They must be mounted AND calibrated in either the horizontal (preferred) or vertical plane. 1. Connect the right angle bracket to the mounting surface with 2 self threading screws in the two 3/16" (5 mm) mounting holes. 2. Inset the controller, face down, up, right or left. Controller must be adjusted and installed in the same plane or readjustment will be necessary. 3. Make sure to leave enough room to make connections. Connections For all models of the CSC-3000 Series use 1/4" (5 mm) O.D. FR tubing, on the following push-on fittings: 1. Connect the clean, dry, main air supply to Port M. 2. Connect the damper actuator to Port B. 3. Connect the Thermostat output to Port T. 4. Connect the total pressure tap on the air flow sensor to Port H. 5. Connect the static pressure tap on the air flow sensor to Port L. Adjustments and Calibration Damper Action The damper action is factory set at Normally Open (N.O.). To field select Normally Closed (N.C.): 1. Loosen damper selection screw. 2. Turn selection dial clockwise until the NC arrow aligns with the Damper arrow. 3. Tighten selection screw. Page 7 of 8

Adjustments and Calibration Continued Thermostat Reset Span and Start: The thermostat reset span is factory set at 5 psi. To field adjust: 1. Remove gauge tap cap at Port G 2. Attach a 0 30 psi pressure gauge 3. Adjust thermostat pressure at Port T to 20 psi 4. Adjust Reset Span (CCW to increase, CW to decrease) until gauge pressure is equal to the desired rest span. This is total span pressure, not the ending span pressure. 5. Adjust thermostat pressure at Port T to desired start pressure. 5. Adjust the Reset Start until the gauge pressure begins to increase slightly. 6. Replace the gauge tap cap. Differential Pressure Range Deviation from the original 5 psi reset span will either directly, and proportionally, effect the CSC-3000 s differential pressure range. To adjust the differential pressure range on a Normally Open or Normally Closed damper with direct or reverse acting thermostat: 1. Adjust the center knob, LO STAT (ccw to increase) to desired air flow with 0 psi at Port T. 2. Adjust the center right knob HI STAT (ccw to increase) to desired air flow with 20 psi at Port T. NOTE: LO STAT is always calibrated first. This air flow setting is the minimum for DA/Cooling or RA/ Heating applications, or maximum for RA/Cooling or DA/Heating applications. HI STAT is always calibrated second. This air flow setting is the maximum for DA/Cooling or RA/ Heating applications, or minimum for RA/Cooling or DA/Heating applications. NOTE: Always make adjustments in the same plane/orientation as the one in which the unit will operate. Maintenance No routine maintenance is required. Each component is designed and manufactured for reliability and performance. Careful installation and use will ensure long term dependability. KMC Controls P.O. Box 497 19476 Industrial Drive New Paris, IN 46553 574.831.5250 www.kmccontrols.com Page 8 of 8 213-019-01J