TXV - Characteristics TXV pumps are available in 11 models from to 150 cc/rev maximum displacement. Pump reference Direction of rotation Maximum displac. (1) Max. operating pressure Max. peak pressure (intermittent: 5%) Torque at 300 bar Max.speed (2) Weight Overhang torque (3) (cc/rev) (bar) (bar) (N.m) (rpm) (kg) (N.m) Standard pump range TXV 0512950 0512955 0 420 225 3000 26 34 TXV 60 0512500 0512505 60 0 420 335 2600 26 34 TXV 75 0512510 0512515 75 0 420 420 2000 26 34 TXV 92 0512520 0512525 92 0 420 515 1900 26 34 TXV 120 0515700 0515705 120 3 0 675 2100 26 34 TXV 130 0515300 0515515 130 365 3 730 2100 28,2 36 TXV 150 0518600 0518605 150 310 330 8 2000 28,2 36 TXV 130 indexable 0520300 / 130 360 3 730 1750 29,3 42 TXV 150 indexable 0525070 / 150 310 330 8 1750 29,3 42 With through shaft TXV 130 0518700 0518705 130 360 3 730 1900 31.1 47.4 (1) TXV pumps can be set for smaller maximum displacements (see page 37). (2) Higher speed possible depending on flow required : please contact us. (3) Overhang torque of the pump only. Viscosity affects maximum possible rotating speed. If viscosity > 0 cst, please contact us to obtain corresponding speed possibilities. For indexable series: see pages 34 and 35. Calculation of power to be supplied to the shaft as a function of flow and pressure P = P x Q 600 Calculation of torque to determine PTO, as a function of power and speed P C = x1000 where ω = πn ω 30 where: P = theoretical hydraulic power in kw C = theoretical torque in N.m N = rotating speed in rpm P = differential pressure in bar Q = flow in l/min ω = angular speed rad/s Ideal installation Return to the tank Force on pump shaft Fr : Acceptable max. radial force = 3000 N Fa : Acceptable axial force = 1600 N. Fr Drain line Inlet line Outlet line Pilot line Application circuit Fa Splined shaft : 8-32-36
Performance - TXV Torque absorbed as a function of pump output pressure 900 Torque (N.m) 0 700 600 500 0 300 200 100 0 0 50 100 150 200 250 300 350 0 450 TXV 150 n x / TXV 150 TXV 130 n x / TXV 130* TXV 120 TXV 92 TXV 75 TXV 60 TXV * TXV with through shaft Pressurs (bar) Flow as a function of rotating speed Q (l/min) 300 250 200 150 100 50 TXV 150 n x / TXV 150 TXV 130 n x / TXV 130* TXV 120 TXV 92 TXV 75 TXV 60 TXV * TXV with through shaft 0 0 500 1000 1500 2000 2500 3000 N (tr/min) Flow as a function of speed, with pump in maximum displacement position and oil level in tank above the pump. Volumetric efficiency These graphs are the results of testwork done in HL R&D laboratory, on a specific test bench, with an ISO 46 fluid at 77 F/25 C (100 cst). TXV series 100 % Efficiency at 1,000 rpm 90 0 100 200 300 360
TXV to 120 - Dimensions TXV TO 120 331.1 276 Maximum pressure setting Drain G3/8" to be connected to tank 125 55.1 9 Standby pressure setting LS G1/4" Splined shaft: 8-32-36 M12x1.75-6H 247.8 F f7 194 12.75 (4x) Dimensions in mm. TXV connections Pump reference Outlet Inlet A B (Ø) (Ø) (mm) (mm) TXV to 92 G 3/4" 15 19 G 1"1/2 TXV 120 G 1" 6 23.57 M10x1.5-6H (2x) Depth 15 mm to attach support device A 25 Outlet 6.45 29 6.45 29 Inlet A 25 Inlet Outlet 28 B 36 CW 28 36 CCW B Support device In cases where it is necessary to use a support device for the pump, this must be fixed to the same part which the pump is mounted on. * Support device Mass and position of centre of gravity L (mm) M (kg) TXV to 92 130 26 TXV 120 130 26 TXV 150 128 27.2 TXV 130 with through shaft 152.6 31.1 143 28.3 Centre of gravity M Screw M10 L * This support has to be designed to avoid strain on the pump flange
Dimensions - TXV 150 TXV 150 321.1 266 Maximum pressure setting Drain G3/8" to be connected to tank 127 55.1 9 Standby pressure setting LS G1/4" Splined shaft: 8-32-36 M12x1.75-6H f7 219 277 F M10x1.5-6H (2x) Depth 15mm to attach support device 50 50 12.75 (4x) Dimensions in mm. 29.4 37 32 CW CCW TXV series
TXV 130 with through shaft - Dimensions TXV 130 THROUGH AFT PUMP The TXV 130 pump exists in a through shaft version. With side porting for inlet and output, this through shaft TXV 130 configuration means any LEDUC TXV pump, or fixed displacement XPi or PA pump, can be mounted on the back. The maximum displacement of the through shaft TXV 130 can be factory set, on request, between 60 and 130 cc/rev. It is important to check that maximum torque to be transmitted by the shaft of the through shaft TXV 130 does not exceed 900 N.m. 27 15 M10x1.5-6H (2x) Depth 15mm to attach support device Maximum pressure setting 382.6 327.5 Drain G3/8" to be connected to tank Interface to mount TXV, XPi, PA pumps (splines 8-32-36 DIN ISO 14 - NF E 22.131) 55.1 9 Standby pressure setting Splined shaft: 8-32-36 E f7 228 281.5 F 57.1 Splined hub: 8-32-36 127 LS G1/4" Interface to mount TXV, XPi, PA pumps M12x1.75-6H 12.75 (4x) Dimensions in mm. View from E (Shaft side) (Hub side)
Dimensions - TXV 130 with through shaft TXV 130 THROUGH AFT PUMP (see p.30) CW CCW Support device The support device for the pump must be fixed to the same part which the pump is mounted on (see diagram below) and has to be designed to avoid strain on the pump flange. Support device C C Example of two TXV pumps. Example of TXV with a PA pump. Maximum torque transferable by the shaft of the pump driven by the PTO: TXV series C C = 900 N.m That is, the sum of torque for both pumps must be < 900 N.m. Example of TXV with a XPi pump. Please consult our Technical Department for advice regarding your installations.