PRELIMINARY. Ordering Part Numbers: Converter P/N: AX082600

Isolated and rugged 24 Vdc power for battery powered electronic control systems on rail equipment

TECHNICAL DATASHEET#TD1516AX 3 AMP SOLENOID DRIVER

55GS1 DC/DC Converter

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

MD60 Series 60W DINergy Power Supply

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

PRODUCTS: POWER SUPPLY

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options

HAE S 05 W - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

STRATO LED Drivers Metal Enclosure 35W, Single output

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

VENTO LED Drivers. VENTO LED Driver. Features. LED Module. Active LED Cooler

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

SECTION DC POWER SUPPLY/BATTERY CHARGER

ELECTRICAL BUS BARS PRODUCT CATALOG #5

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

INDUSTRIAL POWER SUPPLIES SFL-SERIES

DCMCW60 SERIES FEATURES

USER MANUAL 6 Position Powered Rack for TD Series Modules TDR 01 AC

Power Supplies. SDN-C Compact DIN Rail Series

Data Sheet GTD21108 SERIES 20W. (201) Switching Power Supplies

USER MANUAL 6 Position Front Connect Rack for TD Series Modules with 16 Channel Modular Front Panel TDP

DART Charger Product Description, Information and Specification

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

STRATO LED Drivers 70W, Single output

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

User Manual. Solar Charge Controller 3KW

Mass Sine 24/10000 Mass Sine 24/15000

Switching Power Supplies

XLR Energy Storage Module

PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

Service Manual for Battery Control Center

EPIC Hermetic Sealed DC and AC Contactor Amp Power Switching RoHS Compliant, all date codes

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

RCD15W Series PART NUMBER STRUCTURE

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Battery Equalizer. Table of Contents Introduction. 2. Specifications.. 3. Theory of Operation Typical Applications... 5

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

ABB central inverters ULTRA-750/1100/ kW to 1560kW

EMERGENCY VEHICLE BATTERY MANAGER PS2024

PG02S Series 2W DC/DC CONVERTER, SIP-Package

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

1.0 Features and Description

Power Supplies PSS Series

Unit/Comments. %; Equal Output Loads %; Equal Output Loads Full Load

Installation and Operations Manual

DT Series Technical Manual

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

GB60S 60W Single Output General Purpose Series

Power Conversion. Battery Chargers. Model

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

AA-AMPX-SS. Stage I & II Air Management Packages w/ SwitchSpeed Controller

Lockout Hysteresis Voltage VDC Maximum Input Current Vin=18V, 100% Load A

MMC RTX series EN3716

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

15 Watt Low-Profile Wall Plug-In, Single Output, 5-24 VDC Switching Power Supply: N.A., Universal Input, ITE, Class II, Energy Star

Amphenol-Tuchel Electronics 44 Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

AC Switches: ML & MN Series DC Switches: MDC1A Series

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

GMT Fuse Panel Installation Guide

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Open Frame Power Supplies

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Features. Description. Table of Contents

STAR DAMPERS ASTRAL ACTUATOR (DA SERIES)

Caution. Description. Specifications and Ordering Information and Accelerometers

BZ Products Inc. U.S.A.

WATT MBH SERIES DC/DC CONVERTERS

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

OTEC Transfer switch open transition

Offshore and process industry Safety and Automation Systems (SAS) Marine Communication systems onboard ships. Railway & Metro infrastructure

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Phoenix Inverter

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

SSI Technologies MediaSensor

INTRONICS CORPORATE PROFILE

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

L830 Series Isolation Transformers

F-Series 30W PV Module SPM030P-WP-F

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

2008/2009 Product Catalog

Transcription:

Features: TECHNICAL DATASHEET #TDAX080000 48V-24V DC/DC Converter 240 Watts (24VDC) Isolated, Rugged P/N: AX080000K 48V-24V DC/DC Converter Input operating voltage range from 35 to 75VDC Conditioned output of 24VDC 2%, 240 Watts No minimum load requirement Switch mode operation delivers high efficiency Active reverse polarity protection Input to output isolation Robust, rugged and highly reliable Compact size for ease of mounting in confined spaces Connects via a 4-pin plug with 2 meter lead wires Suitable for moist, high shock and vibration environments Operational from -40 to 85 C IP65 protection Applications: SCADA Systems Charging Battery Based Power Supply Systems Remote Terminal Units (RTU) Power Conditioning for Controls & Instrumentation Switchgear Off-Highway Equipment Control Systems Motor Control Centers Marine Auxiliary and Propulsion Systems Machine Control Systems Telecommunications, Data communications These applications are found in a variety of industries including telecom and datacom equipment or industrial power systems, electric utilities, oil & gas, water/wastewater and mobile equipment. Description: The DC-DC Converter provides clean 24VDC power suitable for instrumentation and control networks or process equipment. For operation under the most harsh and demanding conditions, the unit is fully sealed and enclosed to protect against moisture, shock and vibration. Power from a battery or other source in the range of 35-75VDC is converted to a 24VDC regulated to 2%. Input to output isolation is provided. The unit is designed with extremely rugged surge and transient suppression in addition to sustained over/under voltage protection. With a nominal nameplate rating of 240 Watts of output power, the DC-DC Converter has an efficiency rated at >90%. Ordering Part Numbers: Converter with Wire Harness KIT: AX080000K (KIT AX080000 Converter, AX070103 Wire Harness) Items can also be ordered individually. Converter: AX080000 Mating Wire Harness, 2 m: AX070103 Mating Plug Kit: AX070117

Block Diagram Figure 1.0 48-24V DC/DC Converter - Block Diagram Technical Specifications: All specifications are typical at nominal input voltage and 25 degrees C unless otherwise specified. Input Specifications Output Specifications Power Source 48 VDC nominal Nameplate Rating (Output Power) 240 Watts nominal 260 Watts maximum Operating Voltage Range 35 75VDC continuous Output Current 10A continuous (nominal @24VDC) 11A maximum (in current mode) Maximum Input Current 7.5 Amps DC Output Voltage 24VDC 2% Reverse Voltage Protection Provided Output Voltage Ripple V(RIPPLE) < 250 mvpp Turn-on Time (with full load) 250 msec max/5% of final value Turn-on Overshoot None Stability Transient Response Short Circuit Current Stable at all loads (no minimum load requirement) 200mV/1.5ms (No Load to Full Load) 100mV/1ms (50% - 100% Load) Protection provided Self recovery 11A current limit TDAX080000 2

General Specifications Isolation Isolated from input, output and chassis ground 500V between primary and secondary Efficiency Average Efficiency BATT+ Volts % Volts 91.83 31.6 92.01 31.99 92.13 32.99 92.33 34.00 92.41 35.01 92.57 36.02 92.62 37.02 92.66 38.02 92.70 39.00 92.74 40.00 92.80 41.01 92.81 42.00 92.83 43.00 92.86 44.01 92.86 45.01 92.90 46.01 92.97 47.01 93.03 48.01 92.56 49.02 92.65 50.00 92.87 51.00 92.86 52.00 92.92 53.00 92.93 54.01 92.92 55.01 92.90 56.00 Packaging and Dimensions Aluminum enclosure with encapsulation 7.20 x 5.90 x 3.02 inches 182.88 x 149.86 x 76.84mm (W x L x H) TDAX080000 3

Operating Temperature Storage Temperature Humidity -40 to 85 C (-40 to 185 F) See Figure 2.0 for derating curve. -50 to 85 C (-58 to 185 F) 0-99% relative humidity (non-condensing) Figure 2.0 48-24V DC/DC Converter Derating Curve Electrical Connection 4 pin Deutsch connector P/N: DTP04-4P-L012 Pin Out: Mating Wire Harness Protection Rating Weight A mating plug wire harness assembly is available. P/N: AX070103 (The mating plug assembly is comprised of Deutsch P/N: DTP06-4S, WP4S and four contact sockets 0462-203-12141 with 2 meters (6.5 ft.) of 12 AWG lead wires, unterminated.) Mating Wire Harness Pin Out: Red Input + Black Input Black/White Output Red/White Output + IP65 5.70 lbs. (2.58 kg) TDAX080000 4

Grounding Protective Earth (PE) must be connected to the grounding stud to reduce the risk of electric shock. The conductor providing the connection should have a ring lug and wire larger than or equal to 4 mm 2 (12 AWG). The ring lug should be placed between the nut and a star washer. (To secure the ground strap, use a 8-32 K- LOK locknut, stainless steel, 3/8 O.D.) All chassis grounding should go to a single ground point designated for the machine and all related equipment. Mounting The ground strap that provides a low impedance path for EMI should be a ½ inch wide, flat, hollow braid, no more than 12 inches long with a suitable sized ring lug for the module s grounding lug. It may be used in place of the PE grounding conductor and would then perform both PE and EMI grounding functions. Mounting ledges include holes sized for ¼ inch or M6 bolts. The bolt length will be determined by the end-user s mounting plate thickness. Typically ¾ inch (20 mm) is adequate. Installation If the module is mounted without an enclosure, it should be mounted vertically with connectors facing left and right to reduce likelihood of moisture entry. All field wiring should be suitable for the operating temperature range of the module. Install the unit with appropriate space available for servicing and for adequate wire harness access (6 inches or 15 cm) and strain relief (12 inches or 30 cm). 1. A maximum 30A fuse is recommended in the primary circuit to provide protection for the primary wiring. 2. Use four ¼-20 1-inch screws to mount the converter. 3. Ground the unit to chassis ground by attaching a ground strap to the ground stud and locking washer found on the housing (see mechanical drawing). 4. Snap the plug connector into the mating receptacle mounted on the converter. 5. Connect the wiring to power and output terminal blocks (provided by customer). 6. Once the load is ready to receive power, turn on the power source to the converter. Specifications are indicative and subject to change. Actual performance will vary depending on the application and operating conditions. Users should satisfy themselves that the product is suitable for use in the intended application. All our products carry a limited warranty against defects in material and workmanship. Please refer to our Warranty, Application Approvals/Limitations and Return Materials Process as described on www.axiomatic.com/service.html. Form: TDAX080000-02/27/15 2015 Axiomatic Technologies Corporation TDAX080000 5