PIT, PIF & PIX Pressure-to-Current Transmitters

Similar documents
PIT, PIF & PIX. Features. Pressure-to-Current Transmitters

LRX LRX. TemperatureTransmitter. Low-Power. April B. Low-Power. Temperature Transmitter

Type Type 1001 Transducers. I/P & E/P Transducers

Series Level-Trol Electronic Liquid Level Transmitters

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

Miniature I/P, E/P Transducer

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

Type Type I/P & E/P Transducers

Fisher 546 Electro Pneumatic Transducer

Smart Pressure Transmitter

Special Purpose Transmitters

V200 Series Positioners

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

VALVE ACCESSORIES & CONTROLS V200 POSITIONER A POSITIONER THAT OFFERS IT ALL IN ONE COMPACT, SIMPLE, HOUSING

Type I/P & E/P Transducers

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)

V200 Series Positioners

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

Flexible Sensors for Thermowell Temperature Assemblies

Features. Flexibility

LTX RF LEVEL SENSOR. Instruction Manual

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION

OEM Pressure Transmitters

Series 8000 Air Actuated Valves

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

RCM. Direct Reading Flowmeter. for Liquids or Gases

Type A-10 General Purpose Pressure Transmitter

V200 Series Positioners

Type A-10 General Purpose Pressure Transmitters

Bourdon Tube Pressure Switches

G2 Industrial Grade Meters

Fisher i2p 100 Electro Pneumatic Transducer

Low Profile Insertion Vortex

Type 2000 Transducer Product Instructions

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

Precision Control Devices

Masoneilan Series

Smart Pressure Transmitter

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

CONTROLS INC. Position Indicators. Valve Positioners

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

HX-P420 SERIES 4 to 20 ma OUTPUT

Corrosion Resistant Pneumatic Positioners Model 4700P and 4700E

FasTrak High Capacity Smart Positioner

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

Rosemount 3051S Electronic Remote Sensor (ERS) System

Differential pressure gauge Model , copper alloy Model , stainless steel version

Smart Pressure Transmitter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Type 3660 and 3661 Positioners

Model FVP General Specification. Flanged Vortex Plate. Product Features

SG1000A Slide Gate Sensor Slide Gate & Valve Position

Sanitary RTDs and Temperature Transmitters

Model DFX Doppler ultrasonic flow meter

Electric Actuators Maximum in-lbs

Proximity Transmitters, and Seismic Vibration Transmitters

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition

User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

F-2700 SERIES INSERTION VORTEX FLOW METER

Automation Capabilities

Series Village Lane Easley, SC Ph: (864) Fax: (864) Worm and Spur Gear Electric Actuators

FM Approved Remote Kit Assembly (Part No ) Standard Remote Kit Assembly (Part No ) G2 SERIES G2 Industrial METER MODULES

Hot Tap Insertion Vortex

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26

PISTON STYLE GAUGE. Mid-West Instrument

Installation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System

ELECTRICAL INSTALLATION

CML Electric Actuator for Baumann Series

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA U.S.A. TEL: (215) FAX: (215)

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Point level measurement Capacitance switches

F-1500 SERIES INSERTION TURBINE FLOW METER

Micro Motion F-Series Coriolis Flow and Density Meters

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Transcription:

R, PIF & PIX October 2017 Description Moore Industries family of pressure-to-current transmitters provide an economical solution when a pneumatic device must interface with a data acquisiton control system, controller, recorder, or other electronic instrument. These compact, yet powerful units accept a pneumatic signal (3-15 psig, 0.2-1 bar, 3-27 psig, etc.) and accurately convert it to a proportional 4-20mA (or 10-50mA) output. Control Room and Field Mounting Our complete line of P/I transmitters includes models perfect for both control room and field mounting. Moore Industries P/I transmitters are available with a wide variety of housings, and with special features and options. For detailed information, see Table 1 and the Ordering Specifications table. Certifications Factory Mutual Research Corporation (FMRC) Non-Incendive [DIN] & PIX [EXI, EXIP, HP]: Class I, Division 2, Groups A, B, C, D Explosion-Proof PIX [EXI, EXIP]: Class I, Division 1, Groups A, B, C, D NEMA 4X; IP65 Moore Industries complete line of reliable P/I transmitters includes units suitable for mounting in almost any field and control room environment. Features Immune to shock, vibration and position. Perform with exceptional accuracy (±0.2% of span) even in unstable environments. Mount in any position without performance loss. C US Canadian Standards Association (CSA) General Location PIX [HP] Intrinsically-Safe PIX [HP] with -ISC option: Class I, Group D; Class II, Groups E, F, G; Class III Explosion-Proof PIX [P3LS] Class I, Groups C, D; Class II, Groups E, F, G; Class III Canadian International (Canada & US) General/Ordinary Locations [DIN] Long, trouble-free service life. Being 100% solid state, there are no moving parts to wear out or adjust. Self-sealing pneumatic connection. The and PIX (HP) can be taken out of service without disconnecting the pneumatic line and with no air loss. CE Conformant EMC Directive 2014/30/EU EN61326 Pneumatic Transmitter 3-15psig 4-20mA Figure 1. Pneumatic Transmitter to Computer System Interface. 2017 Moore Industries-International, Inc. 218-710-01W Page 1

Specifications Performance Calibration Capability: Error shall not exceed ±0.2% of span including independent linearity as defined in SAMA Standard PMC 20.1 1973 Repeatability: Within ±0.1% of input span Resolution: ±0.05% of input span Maximum Non-Linearity: ±0.2% as per SAMA PMC 20.1 1973 Load Capability: 600 ohms at nominal 24Vdc Load Effect: ±0.01% of span from zero to maximum load RFI/EMI Effect: (DIN) and PIF: With field strengths of 10 V/m at frequencies of 20-500MHz, less than ±0.1% span change; PIX: With field strengths of 30 V/m at frequencies of 20-500MHz, less than ±0.1% of span change Performance (continued) Ambient Temperature Connections Input: Instrument air only Pressure Limit: 150% full scale input pressure without damage Output Limit: 130% of output span Output Ripple: Negligible Line Voltage Effect: Less than ±0.01% of span per volt of line voltage change at the input terminals Range: 1.1 C to +54 C (+30 F to +129.2 F) Effect: Less than ±2.0% of full scale input over above range (DIN-Style): 1/8-inch NPT female is standard, 1/8-inch NPT male is optional PIF: Pneumatic: 1/4-18 NPT female is standard, plastic tube fitting for 1/4-inch O.D. tubing is optional; Electrical: 1/2 NPT female (WP), M20 X 1.5 female (WPM) Connections (continued) Adjustments Weight PIX (Hockey-Puck): Pneumatic: 1/4-inch NPT female PIX (EXI and EXIM): Pneumatic: 1/4-inch NPT female; Electrical: 1/2 NPT female (EXI); M20 x 1.5 female (EXIM) Type: Multiturn adjustments (no interaction between span and zero adjustments) Span: Fully adjustable to 100% of output span Zero: Adjusts 0 to ±10% of span (DIN-Style and 4-Wire) and PIX (Hockey-Puck): 340 grams (12 ounces) PIX (EXI and EXIM): 1.25 kilograms (2 lbs., 13 oz.) PIF: 490 grams (1 lb., 1 oz.) Table 1. Unit Descriptions and Special Features. Unit Mounting Options Special Features 2-Wire Aluminum DIN-style housing (DIN) Snaps on a G rail or Moore Industries DPR DIN-style rack Only 1-inch wide, perfect for installation in a control room or field-mounted cabinet. Front panel LED varies in intensity with the level of the input signal. Available with pneumatic test jack (use with pneumatic test coupler P/N 163-202-00) and a removable terminal block. A wide range of certifications, including Intrinsic Safety, available. PIX 2-Wire Hockey-puck (HP, FL and P3LS) and Extruded Aluminum (EXI and EXIM) housings Explosion-proof enclosures mount on a 2-inch pipe or surface; hockey-puck with flanges mounts on a relay track Explosion-proof enclosures mount in rugged field environments. Models with a wide range of certifications including explosion-proof available. Explosion-proof versions have inherent 30V/m RFI/EMI protection. PIF 2-Wire NEMA 4X (IP55) Polyetherimide thermoplastic housing (WP and WPM) Mounts (vertical or horizontal) on a 2-inch pipe or surface Watertight, dust-tight, and corrosion-resistant; superior heat, flame (rated UL94V-0 flame retardant), impact and chemical resistance. 4-Wire Standard housing (AB and WT) Mounts on a surface or in a protective enclosure Can be powered directly from a 117, 220, or 240Vac source. Page 2 Specifications and information subject to change without notice.

Ordering Information Unit Input Output Power Access Options 2-wire, DIN-style (10-50mA also available) 12-24DC 12-30DC 12-42DC See Table 2 -ISC CSA approved Intrinsically- Safe (12-24DC power required) -RTB Removable Terminal Block DIN Aluminum DIN-style rail-mount housing WTP1 NEMA 4 enclosure for one or WTP2 for two s PIX 2-wire, Hockey Puck (HP, FL, and P3LS) or Extruded Aluminum (EXI and EXIM) (10-50mA also available) 12-24DC 12-42DC Not Required -GA1 Pressure gauge offered as installed accessory (EXI and EXIM housings only) -ISC** CSA approved Intrinsically- Safe (12-24DC power required) -PTJ Unit comes equipped with pneumatic test jack (EXI and EXIM housings only) -RO Reverse output whereby output decreases proportionally to input increase Note: Standard unit is Factory Mutual and CSA approved explosion proof ** -IS options not available with HP housing EXI* Extruded aluminum explosionproof housing (NPT conduit entry port) (FM Approved) EXIM* Extruded aluminum explosion-proof housing (metric conduit entry port) (No FM) HP** Hockey-puck housing with spring clips for mounting in an explosion-proof enclosure FL Hockey-puck housing with flanges for surface or relay track mounting P3LS* Hockey-puck housing in a 3-hub, solid cover, explosion-proof enclosure * When P suffix is added to the model number, unit comes equipped with U-bolts for mounting on a 2-inch pipe (e.g. P3LSP, EXIP, P3HS, P3HG) ** -IS options not available with HP housing PIF 2-wire, Thermoplastic 12-42DC Not Required -RO Reverse output whereby output decreases proportionally to input increase -TF1 Plastic tubing fitting offered as installed accessory for 1/4-inch O.D. tubing WP* Polyetherimide thermoplastic, NEMA 4X (IP55) housing with 1/2-inch NPT female wire entry threads WPM* Metric version of the housing with M20 x 1.5 female wire entry threads * When P suffix is added to the model number, unit comes equipped with U-bolts for mounting on a 2-inch pipe (e.g. WPP) 4-wire, Standard (10-50mA also available) 117AC 220AC 240AC (50/60Hz, ±10%) Not Required -4W Required option for 4-wire -BF Female bulkhead fitting (1/4-inch NPT) AB Standard housing with angle flanges for surface mounting (see the AB housing sheet for details) WT AB housing mounted in watertight, NEMA 4 enclosure (-BF option required) * When P suffix is added to the model number, unit comes equipped with U-bolts for mounting on a 2-inch pipe (e.g. WPP) To order, specify: Unit / Input / Output / Power / Access ( DIN-style only) / Options [] Model Number Examples: / / / 12-42DC / -RTB [DIN], PIF / / / 12-42DC / -TF1 [WP] PIX / / / 12-42DC [EXI], / / / 117AC / -4W [AB] Page 3

Figure 2. DIN-Style Dimensions Front access pneumatic test jack 25mm (1.00 in) 10mm (0.40 in) 118mm (4.65 in) G-type Din-rail (P/N 800-124-24) 85mm (3.35 in) Rear access location SIDE VIEW 1/8-inch NPT fitting (bottom or rear) Bottom access location 14mm (0.56 in) FRONT VIEW 11mm (0.45 in) Figure 3. G-Type Mounting Rail (P/N 800-124-24, Specify Length) Table 2. Access Designations for DIN housing Electrical Output Location Pneumatic Input Location Pneumatic Test Jack Location Access Designation Front Bottom None -FA1 Front Rear None -FA2 Front Bottom Front -FA3 Front Rear Front -FA4 Front (no mtg. block) None -FA7 Front (no mtg. block) Front -FA8 Rear Rear None -RA1 Rear Bottom None -RA2 Rear Rear Front -RA3 Rear Bottom Front -RA4 Rear Rear Rear -RA5 Rear Bottom Rear -RA6 Rear (no mtg. block) None -RA7 Rear (no mtg. block) Front -RA8 Rear (no mtg. block) Rear -RA9 15mm (0.59 in) 10mm (0.42 in) 32mm (1.26 in) CL 16mm (0.65 in) Screws may project 6.35mm (0.25 in) without interference Figure 4. Test Coupler (P/N 163-202-00) for units with pneumatic test jack 6.35mm (0.25 in) DIA. plastic tubing (not supplied) 6mm (0.24 in) Page 4

Figure 5. Up to 16 high-density DIN-style s mount on a DPR Multi-Unit Rack 8mm (0.31 in) 29mm (1.12 in) 482mm (19.0 in) 467mm (18.38 in) 426mm (16.75 in) 142mm (5.26 in) 50mm (2.00 in) Rear access electrical connections to s 88mm (3.47 in) 76mm (3.00 in) 6mm (0.23 in) 6mm (0.23 in) x 12.7mm (0.50 in) 1/8-inch thick aluminum side plates (2) Rear access pneumatic connections to s Wire duct and cover 25mm (1.00 in) x 38 mm (1.50 in) Figure 6. EXI and EXIM Dimensions 127mm (5.00 in) 64mm (2.50 in) square 89mm (3.50 in) square 99mm (3.90 in) 114mm (4.50 in) 89mm (3.50 in) 102mm (4.00 in) 114mm (4.50 in) 145mm (5.70 in) Page 5

Figure 7. Hockey-Puck Dimensions 76mm (2.97 in) 45mm (1.75 in) 38mm (1.50 in) 43mm (1.68 in) 21mm (0.82 in) HP HOUSING FITTING 83mm (3.25 in) GND 76mm (2.86 in) ZERO 1 3 5 2 4 6 SPAN 41mm (1.63 in) 61mm (2.40 in) FL HOUSING FITTING 1/4-inch NPT fitting FRONT VIEW SIDE VIEW Figure 8. WP and WPM Dimensions 4 mounting holes Symmetrical mounting hole pattern permits mounting on either horizontal or vertical pipe 97mm (3.68 in) 70mm (2.75 in) Wire entry port 1/2-14 NPT threads -WP -WPP Options M20 X 1.5 Threads 33mm (1.30 in) -WPM -WPMP Options 57mm (2.25 in) Plastic tube fitting for 1/4 O.D. tubing (-TFI option) 142mm (5.60 in) 2-inch pipe BOTTOM VIEW 29mm (1.15 in) Pneumatic supply port 1/4-18 NPT 31mm (1.22 in) 38mm (1.50 in) SIDE VIEWS United States info@miinet.com Tel: (818) 894-7111 FAX: (818) 891-2816 Australia sales@mooreind.com.au Tel: (02) 8536-7200 FAX: (02) 9525-7296 Belgium info@mooreind.be Tel: 03/448.10.18 FAX: 03/440.17.97 The Netherlands sales@mooreind.nl Tel: (0)344-617971 FAX: (0)344-615920 China dho@mooreind.sh.cn Tel: 86-21-62491499 FAX: 86-21-62490635 United Kingdom sales@mooreind.com Tel: 01293 514488 FAX: 01293 536852 Page 6