N0N A 250V One-Time Class H Fuse

Similar documents
FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Low-Peak 600V Class RK1

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

FLQ4 4A 500V TD CT Midget Fuse. Descriptions 4A 500V TD CT MIDGET FUSE Time Delay Midget Fuse 4 Amp. Manufacturer Information

FLQ /2A 500V TD CT Midget Fuse. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

Low voltage, branch circuit fuses

Low Voltage, Branch Circuit Rated Fuses

Bussmann. Circuit Protection Solutions

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

Fast-acting supplemental fuse. For superior protection, Bussmann recommends upgrading to Low-Peak Class CC fuses. See data sheet # 1023.

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

Electric vehicle auxiliary fuses 500 Vdc, A

Assembly not available for new installations.

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

BH-1 modular fuse blocks, 700 V, 400 A

UL Recognized power distribution blocks

General Data Dimensions (Inches) Bussmann

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP)

SW Tog DP 30A 120/277V Autogrd B&S WH

Bussmann series Quik-Spec Power Module Switch elevator disconnect

FUSES 8.1. Questions? Answers at Western US: CED-ELEV

Class J modular ferrule and knifeblade fuse blocks

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP)

Accessories. For product data sheets, visit

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

6.3 mm reverse quick connect

20A-125V DPLX RCPT. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight. Long Description

Effective December 2015 Supersedes September 2013

TA Ta VA CTRL-XFRMR

British BS 88 Fuses. High Speed Fuses. Introduction. General Information

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

Low-Peak fuses offer the industry s most advanced circuit protection

R6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description

PT Medium voltage fuses for potential and small power transformers

Compact Circuit Protector

Fuse Accessories. Bussmann - Fuse Holders. Fuse Holders

Ferrule fuses. High Speed Fuses

Class gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

CUBEFuse. CUBEFuse catalog numbers (amps)

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

4750 Recp Duplex 15A 277V 2P3W H/L BK. Features amperage rating. Description RECP DUPLEX 15A 277V 2P3W H/L BK

Fuseology. Dual-Element, Time-Delay Fuse Operation

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

Ω 1 Ω Supplementary Fuses

General Purpose US Fuses

24HR 30A SPST TM SW. Features. Long Description

A 120V BR GFI Recpt. Features. Material, Color, and Finish. Description

LFJ602003C 200A 600V Fus Block

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

C E R T I F I C A T E O F C O M P L I A N C E

The easiest and fastest way to select and specify the right fuse

Bussmann series IEC cylindrical fuses

MS303DS MS-303 3P Man CNT Only. Features. Dimensions and Weight. Long Description

Selection and application guide

Miniature Circuit Breakers

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

Recp Duplex 20A 250V 2P3W STR Swire WH

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

4 Square Partition Square Cut Tile Wall 2 Gang Cover 2 1/8 Deep 1/2 to 1 RSD

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

High Speed Fuses. Section Contents Page

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

Quik-Spec Coordination Panelboard Specifications

SPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

Red Spot Fuse Holders

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

Uses, Certifications, and Standards Electrical Control and Instruments, Indoor/Outdoor EXTERNAL FEET, WALL standard UL 508, CSA C22.

E-RATED/MEDIUM VOLTAGE FUSES

561LVB 561LVB 4 Oct Box W/Bracket. Features. Dimensions and Weight. Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Red Spot Fuse Holders

TRBR20WBXSP 20A TR Comm WH Dup Rec. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight.

Volume 4C: Circuit Protection Bussmann series solutions

Harmonization of IEC and North American Safety Standards

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

Equipment Protection. Transformers 600V or Less

Transcription:

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 AllenWatson@elliottelectric.com N0N 250V One-Time Class H Fuse Catalog Number Manufacturer Description Weight per unit Product Category N0N 250V Class H One-Time Fuse 0.3000 (lbs/each) Renewable & Non-Renewable Features amperage rating class H connection Blade End X Blade End interrupt rating 00 Amp (RMS Symmetrical), 00 Amp at 25 Vdc Voltage Rating 250/25 Dimensions and Weight Size Descriptions Description Long Description Product Type special features.060 In Diameter X 5.88 In Length Manufacturer Information Brand GTIN 0005720684 Manufacturers Part Number NON- UPC 05720684 250V ONE-TIME CLASS H FUSE 250V Class H One-Time Fuse Buss One Time Fuse One Time Fuse Taxonomies, Classifications, and Categories Category Description Fuses & Fuse Accessories Type Non Current Limiting Packaging Carton Package 5 Weight Per each 0.3 Uses, Certifications, and Standards Application standard Light Duty Circuit Locations UL 248-6, CSA, CE

NON (250V) 8-600A, General Purpose Fuses Dimensions in All Diameters ± 0.008 2" (0.03) 0.38" ( 0.094) 0.56" (± 0.008) 2.59" /8 to 450 to 600A 3" (0.03) 8.63" (± 0.094) 0.8" (± 0.008) 2.06" Description: Basic protection 250V NON Class K5 and H general purpose, non-current-limiting, one-time fuses. 35 to 5.88" (± 0.062) 225 to 7.3" (± 0.062) Catalog Symbol: NON-(amp) Ratings: Volts 250Vac 25Vdc ( 8-) Amps 8-600A IR 50kA Vac RMS Sym. ( 8-) 0kA Vac RMS Sym. (65-600A) 50kA Vdc ( 8-) 0kA Vdc (65-) Agency Information: CE, UL Listed, Class K5 ( 8-), Std. 248-9, Class H (65-600A), Std. 248-6 (25Vdc 8-), UL Guide JDDZ, File E4274 CSA Certified, Class 42-0, File 53787 ( 8-2A, 65-600A) For CSA Certified 5-, see PON Data Sheet # 426. Catalog Numbers (amps) NON- 8 NON-3 NON-2 NON-65 NON-200 NON- 2 NON-3 2 0 NON-5 NON-70 NON-225 NON- 3 4 NON-4 NON-20 NON-75 NON-250 NON- 8 0 NON-5 NON-25 NON-80 NON-300 NON- NON-6 NON-30 NON-90 NON-350 NON- 4 NON-6 4 NON-35 NON- NON-400 NON- 2 NON-7 NON-40 NON-0 NON-450 NON- 6 0 NON-8 NON-45 NON-25 NON-500 NON-2 NON-9 NON-50 NON-50 NON-600 NON-2 2 NON-0 NON-60 NON-75 Carton Quantity and Weight Amp Rating Carton Qty. 8-30 0 35 60 0 65 5 0 200 225 400 450 600 70 to.06" 0 to.56" Features: Protect lighting, heating and other circuits not subject to temporary surges and where available short-circuit currents are relatively low NON one-time fuses do not have any appreciable degree of timedelay and thus should not be specified in circuits where large transients or motor overloads occur. Use Bussmann advanced protection FUSETRON FRN-R or ultimate protection Low-Peak LPN-RK dual-element, time-delay fuses. For general purpose circuits, size at amp rating of circuit For motor circuits, size at 300% to 400% according to the NEC motor ampacity tables 430.247 to 430.250, per 430.6(A)() Recommended Fuse Blocks Fuse Amps -Pole 2-Pole 3-Pole 0-30 H25030- H25030-2 H25030-3 35-60 H25060- H25060-2 H25060-3 70- HM25-CR HM25-2CR HM25-3CR 0-200 HM25200-CR HM25200-2CR HM25200-3CR 225-400 HM25400-CR HM25400-2CR HM25400-3CR 450-600 HM25600-CR HM25600-2CR HM25600-3CR For additional information on 250 volt fuse blocks, see Data Sheet # 2 (H250) and product brochure # 392 (HM Series). Fuse Reducers For Class R Fuses Equipment Desired Fuse Catalog Numbers Fuse Clips (Case) Size (Pairs) 250V NO.263 NO.23 NO.26 NO.226 NO.262 NO.264 NO.2642 For additional information on Class K5 & H fuse reducers, see Data Sheet # 8. 073 BU-SB3738 Page of 4 Data Sheet # 030

NON (250V) 8-600A, General Purpose Fuses Time-Current Curves - Average Melt 300 5A 20A 35A 600A AMP RATING 0 TIME IN SECONDS 0. 0.0 20,000 CURRENT IN AMPS 0,000 073 BU-SB3738 Page 2 of 4 Data Sheet # 030

NOS (600V), -600A, General Purpose Fuses Dimensions in All Diameters ± 0.008 5" (± 0.03) 3.38" ( 0.094) 0.8" (± 0.008) 3.3" to 5.5" (± 0.03) 450 to 600A.63" (± 0.094).06" (± 0.008) 2.59" 35 to 225 to Description: Basic protection 600V NOS Class K5 and H general purpose, non-current-limiting, one-time fuses. 7.9" (± 0.062).34" 9.63" (± 0.062).84" Catalog Symbol: NOS-(amp) 70 to 0 to Ratings: Volts 600Vac Amps -600A IR 50kA Vac RMS Sym. (-) 0kA Vac RMS Sym. (70-600A) Agency Information: CE, UL Listed, Class K5 (-), Std. 248-9, Class H (70-600A), Std. 248-6, UL Guide JDDZ, File E4273 CSA Certified, Class 42-0, File 53787 Catalog Numbers (amps) NOS- NOS-9 NOS-40 NOS- NON-300 NOS-2 NOS-0 NOS-45 NOS-0 NOS-350 NOS-3 NOS-2 NOS-50 NOS-25 NOS-400 NOS-4 NOS-5 NOS-60 NOS-50 NOS-450 NOS-5 NOS-20 NOS-70 NOS-75 NOS-500 NOS-6 NOS-25 NOS-75 NOS-200 NOS-600 NOS-7 NOS-30 NOS-80 NOS-225 NOS-8 NOS-35 NOS-90 NOS-250 NOS 600V Carton Quantity and Weight Amp Rating Carton Qty. 30 0 35 60 0 70 5 0 200 225 400 450 600 Features: Protect lighting, heating and other circuits not subject to temporary surges and where available short-circuit currents are relatively low NOS one-time fuses do not have any appreciable degree of timedelay and thus should not be specified in circuits where large transients or motor overloads occur. Use Bussmann advanced protection FUSETRON LPS-R or ultimate protection Low-Peak LPS-RK dual-element, time-delay fuses. For general purpose circuits, size at amp rating of circuit For motor circuits, size at 300% to 400% according to the NEC motor ampacity tables 430.247 to 430.250, per 430.6(A)() Recommended Fuse Blocks Fuse Amps -Pole 2-Pole 3-Pole 0-30 H60030- H60030-2 H60030-3 35-60 H60060- H60060-2 H60060-3 70- HM60-CR HM60-2CR HM60-3CR 0-200 HM60200-CR HM60200-2CR HM60200-3CR 225-400 HM60400-CR HM60400-2CR HM60400-3CR 450-600 HM60600-CR HM60600-2CR HM60600-3CR For additional information on 600 volt fuse blocks, see Data Sheet # 2 (H) and product brochure # 392 (HM Series). Fuse Reducers For Class R Fuses Equipment Desired Fuse Catalog Numbers Fuse Clips (Case) Size (Pairs) 250V NO.663 NO.26 NO.66 NO.626 NO.262 NO.264 NO.2642 For additional information on Class R fuse reducers, see Data Sheet # 8. The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 073 BU-SB3738 Page 3 of 4 Data Sheet # 030

NON/NOS Class K5 & H, 600/250Vac NOS (600V), -600A, General Purpose Fuses Time-Current Curves - Average Melt 300 5A 20A 35A 600A AMP RATING 0 TIME IN SECONDS 0. 0.08 0.06 0.04 0.03 0.02 0.0 20,000 CURRENT IN AMPS 0,000 The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 073 BU-SB3738 Page 4 of 4 Data Sheet # 030