Optanium. High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps DESIGN HIGHLIGHTS: APPLICATIONS:

Similar documents
Reduce Maintenance Costs *

Input Current (Amps) Input Power (ANSI Watts)

High performance for high ceilings

Input Current (Amps) Input Power (ANSI Watts)

Input Power (Watts) (min/max)

Input Power (Watts) (min/max)

Input Power (Watts) (min/max)

Input Power (Watts) (min/max)

Input Current (Amps) Input Power (ANSI Watts)

Input Power (Watts) (min/max)

Input Current (Amps) Input Power (ANSI Watts)

ICN2S40N35I Ele Ballast (2) F40T V

Input Power (Watts) (min/max)

RELB2S40N35I (2)F40T12 120V Ele BLST

Input Power (Watts) (min/max)

Input Current (Amps) Input Power (ANSI Watts)

Performance and Efficiency

1,2,3... As easy as. Mark 10 Powerline. For Compact Fluorescent Lamps

Lighting The Way. Ballast Specification Guide

The sustainable choice. Optanium high-efficiency ballasts for today s T8 lighting needs

The New York University Concourse Project. New York City. Existing Electrical Conditions

HIGH FREQUENCY ELECTRONIC BALLASTS

ELECTRONIC FLUORESCENT BALLASTS

ICN3P32SC35I 3-F32T8 120/277V Electronic Ballast

ELECTRONIC FLUORESCENT BALLASTS

ELECTRONIC FLUORESCENT BALLASTS

VEL2S40SC35I 2 F34T12 277V Electronic Ballast

ELECTRONIC HID BALLASTS

VEL2P75S35I 2-F96T12 277V Electronic Ballast

Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies

ELECTRONIC HID BALLASTS

TVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts

ELECTRONIC FLUORESCENT BALLASTS

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps

EcoSystemR Multiple Control Input Ballasts

Compact SE Overview. High-Performance Dimming. Ballast

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps

Compact SE Overview. High-Performance Dimming. Ballast

Electronic Ballast Update. Schaedler/YESCO EXPO 2008 Presented by Rock Weinrich, Joseph E. Biben Sales Corporation

EcoSystem Multiple Control Input Ballasts

FDBT S 32W120V DM Bal

Distribution Restriction Statement Approved for public release; distribution is unlimited.

Lighting Electronics Atlas

MasterColor CDM-R111 70W/830 10D 1CT

Different ways. The Dynadimmer and the Chronosense. Public outdoor lighting has an important function in making outdoor activities after sunset

Philips LEDstick V Compact Brightness 88% LEDstick

Electronic Fluorescent Ballasts

Ecosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W

EcoSystem Multiple Control Input Ballasts

INSTANT START BALLASTS

QUICKTRONIC ICE Universal Voltage Systems

3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube

RZT2S54 Electr DMMG Ballast

OkSolar LED Outdoor Luminaires

Philips MASTER LEDtube InstantFit Standard Output 1500mm

The right components for your application

IZT2S32SC 2 Lamp 32/T8 Dimmable Ballast

Portfolio innovative LED systems. Fortimo and Lexel

Table of Contents T8 Instant Start Ballasts

ELECTRONIC FLUORESCENT BALLASTS

Nema Head We light your world

Ballast Technology & Specification Guide SYLVANIA QUICKTRONIC Electronic Ballasts

Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps

American Power Design, Inc.

FastFlex LED module Gen 2. Flexible system design and brilliant optical control. KiwiLighting.com

GC SERIES HORTICULTURAL LIGHTING SYSTEM

ELECTRONIC FLUORESCENT BALLASTS

GC SERIES HORTICULTURAL LIGHTING SYSTEM

Street LEDGINE. CitySpirit Street - CitySoul - MileWide

Switch to safe living. Lifestyle modular switches with protective technology

Hi-lume Overview. EcoSystem Hi-lume 1% Architectural Dimming

ELECTRONIC FLUORESCENT BALLASTS

Energy Solutions LED Accelerator Program

Certifications. Catalog. CFQ13W/G24q - 13W CFL Quad Tube Lamp (PL-C13W/4P, F13DBX/4P, CF13DD/E)

TownGuide Core. Easy to choose, easy to use

The power behind today s lighting designs

Installation/Operating Instructions

American National Standard for Lighting Equipment Voltage Surge Requirements

EnergyCalc. Saving energy with sustainable lighting solutions from Grainger

Max. Input Power (W) Inrush Current (A pk /µs)

UL AND CODE COMPLIANCE

PC T8 TEC, W PC TEC

LIGHTING SPECIFICATIONS

Installation/Operating Instructions

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

ICETRON ECOLOGIC Inductively Coupled Fluorescent System

2011 DOE Fluorescent Ballast Rulemaking. Susan Isenhour Anderson Manager of Energy Relations OSRAM SYLVANIA July 2012

Heritage of Quality and Reliability

Product range 2010 /11. isolde the new generation of Philips tanning lamps

Installation/Operating Instructions

L I G H T W A V UV Electronic Ballast E 2010

The right components for your application

HIGH INTENSITY DISCHARGE BALLASTS

FL ballasts Electronic fixed output

Electronic ballasts for fluorescent lamps Multi-lamp ECG. PC T5 PRO-M lp, W T5, T8, compact (CFL) and T5c circular fluorescent lamps

American Power Design, Inc.

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

SubstiTUBE IPS LED T8

F5 Platforms: FIPS Kit Installation MAN

FL ballasts Electronic fixed output

Transcription:

Optanium High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps P R O D U C T O V E R V I E W : Advance expands a new family of Smart Solutions for T8 lighting systems Optanium. Optanium is a high-efficiency electronic ballast family that combines maximized energy savings with the flexibility you need to create a T8 s ystem matched to your requirements. High-efficiency Instant start Optanium ballasts are available to meet specific needs in two versions - a standard light output design (0.87 Ballast ) and a low-watt design (0.77 Ballast ). All have cold-start capability down to -20 F and a low-profile design optimized for today s fixture designs. The ballast also meets the new NEMA/CEE high performance T8 lighting system specifications. DESIGN HIGHLIGHTS: Hi-efficiency Ballast consumes less input watts than a standard efficiency electronic ballast Instant-start lamp ignition Consumes less energy than Rapid-start ballasts UL Type CC Rated Meets UL criteria for arcing protection IntelliVolt technology (108-305V, 50/60Hz) Ensures shipment of correct voltage ballast or fixture for all applications Low-profile, lightweight housing Physically interchangeable with standard electromagnetic and electronic ballasts Provides flexibility in new generation fixture designs Independent lamp operation (ILO) Other lamps continue to operate when one or more lamps fail Striation reduction circuitry Reduces potential for lamp striation typically seen in energy saving lamps. Operates between 40 khz and 52 khz Eliminates interference with Infrared Control Systems or commonly used Electronic Article Surveillance (EAS) systems -20 F starting capability* Suitable for cold temperature situations using standard lamps Centium technology (<10 THD, >0.98 PF) Meets most demanding power quality requirements Perfect for applications where harmonics are a concern 20ft. remote mounting/tandem wiring capability Provides maximum application flexibility Auto-restrike capability Eliminates the need to reset power mains after failed lamps are replaced Operates standard F32T8 lamps and 4 energy saving lamps Provides maximum versatility * Consult lamp manufacturer for temperature versus lamp characteristics Note: 1. All standard models may experience lamp striations when operating with 25W, 28W, or 30W energy saving T8 lamps. The use of the Optanium (IOP) models is recommended to reduce lamp striation. 2. Only the Optanium (IOP) models are suitable for tandem-wiring applications operating 25W, 28W or 30W energy saving T8 lamps. APPLICATIONS: General Lighting Decorative Lighting Retail Lighting Indirect Lighting Tel: 800-322-2086 Fax: 888-423-1882 Customer Support/Technical Service: 800-372-3331 www.advancetransformer.com

ANSI () Ballast F17T8 (17W) 120 0.14 16 0.99-20 F / -28 C 230 IOP-1P32-SC 0.08 16 0.90 10 0.97 1 17 277 0.07 16 0.97 120 0.17 19 0.99-20 F / -28 C 230 IOP-2P32-SC 0.10 19 1.06 15 0.97 277 0.08 19 0.97 120 0.26 31 0.99-20 F / -28 C 230 IOP-2P32-SC 0.13 31 0.90 10 0.97 2 17 277 0.11 31 0.97 120 0.30 35 0.99-20 F / -28 C 230 IOP-3P32-SC 0.17 35 1.01 15 0.97 277 0.14 35 0.97 120 0.38 45 0.99-20 F / -28 C 230 IOP-3P32-SC 0.21 45 0.90 10 0.97 3 17 277 0.17 45 0.97 120 0.41 49 0.99-20 F / -28 C 230 IOP-4P32-SC 0.22 49 1.00 15 0.97 277 0.18 49 0.97 120 0.49 58 0.99 4 17-20 F / -28 C 230 IOP-4P32-SC 0.27 58 0.90 10 0.97 277 0.22 58 0.97 F25T8 (25W) 120 0.20 23 0.99-20 F / -28 C 230 IOP-1P32-SC 0.11 23 0.88 10 0.98 1 25 277 0.09 23 0.98 120 0.23 28 0.99-20 F / -28 C 230 IOP-2P32-SC 0.12 28 1.05 10 0.97 277 0.10 28 0.97 120 0.37 43 0.99-20 F / -28 C 230 IOP-2P32-SC 0.19 43 0.88 10 0.98 2 25 277 0.16 43 0.98 120 0.42 49 0.99-20 F / -28 C 230 IOP-3P32-SC 0.22 49 1.00 10 0.97 277 0.18 49 0.97 120 0.54 64 0.99-20 F / -28 C 230 IOP-3P32-SC 0.29 63 0.88 10 0.98 3 25 277 0.24 63 0.98 120 0.59 71 0.99-20 F / -28 C 230 IOP-4P32-SC 0.31 70 0.97 10 0.97 277 0.26 70 0.97 120 0.72 85 0.99 4 25-20 F / -28 C 230 IOP-4P32-SC 0.37 84 0.88 10 0.98 277 0.31 83 0.98

ANSI () Ballast F32T8, FBO32T8, F32T8/U6 120 0.25 28 0.99-20 F / -28 C 230 IOP-1P32-SC 0.13 28 0.87 10 0.98 1 32 277 0.11 28 0.98 120 0.30 35 0.99-20 F / -28 C 230 IOP-2P32-SC 0.16 35 1.05 10 0.98 277 0.13 35 0.98 120 0.47 55 0.99-20 F / -28 C 230 IOP-2P32-SC 0.24 54 0.87 10 0.98 2 32 277 0.20 54 0.98 120 0.53 63 0.99-20 F / -28 C 230 IOP-3P32-SC 0.28 62 1.00 10 0.98 277 0.23 62 0.98 120 0.70 82 0.99-20 F / -28 C 230 IOP-3P32-SC 0.36 81 0.87 10 0.98 3 32 277 0.30 80 0.98 120 0.75 90 0.99-20 F / -28 C 230 IOP-4P32-SC 0.39 89 0.97 10 0.98 277 0.32 88 0.98 120 0.92 109 0.99 4 32-20 F / -28 C 230 IOP-4P32-SC 0.47 107 0.87 10 0.98 277 0.39 106 0.98 F32T8/ES (25W Philips Lamps) 120 0.20 23 0.99 60 F / 15 C 230 IOP-1P32-SC 0.11 23 0.87 10 0.98 1 25 277 0.09 23 0.98 120 0.23 27 0.99 60 F / 15 C 230 IOP-2P32-SC 0.12 27 1.05 10 0.97 277 0.10 27 0.97 120 0.37 44 0.99 60 F / 15 C 230 IOP-2P32-SC 0.19 43 0.87 10 0.98 2 25 277 0.16 43 0.98 120 0.42 49 0.99 60 F / 15 C 230 IOP-3P32-SC 0.22 49 1.00 10 0.97 277 0.18 49 0.97 120 0.55 65 0.99 60 F / 15 C 230 IOP-3P32-SC 0.29 64 0.87 10 0.98 3 25 277 0.24 64 0.98 120 0.59 70 0.99 60 F / 15 C 230 IOP-4P32-SC 0.31 69 0.97 10 0.97 277 0.26 69 0.97 120 0.73 87 0.99 4 25 60 F / 15 C 230 IOP-4P32-SC 0.37 85 0.87 10 0.98 277 0.31 85 0.98

ANSI () Ballast F32T8/ES (28W) 120 0.22 25 0.99 60 F / 15 C 230 IOP-1P32-SC 0.11 25 0.87 10 0.98 1 28 277 0.10 25 0.98 120 0.26 31 0.99 60 F / 15 C 230 IOP-2P32-SC 0.14 31 1.05 10 0.98 277 0.11 31 0.98 120 0.41 48 0.99 60 F / 15 C 230 IOP-2P32-SC 0.21 47 0.87 10 0.98 2 28 277 0.18 47 0.98 120 0.46 55 0.99 60 F / 15 C 230 IOP-3P32-SC 0.25 54 1.00 10 0.98 277 0.20 54 0.98 120 0.61 72 0.99 60 F / 15 C 230 IOP-3P32-SC 0.31 71 0.87 10 0.98 3 28 277 0.26 71 0.98 120 0.66 79 0.99 60 F / 15 C 230 IOP-4P32-SC 0.34 78 0.97 10 0.98 277 0.28 78 0.98 120 0.81 96 0.99 4 28 60 F / 15 C 230 IOP-4P32-SC 0.41 94 0.87 10 0.98 277 0.35 94 0.98 F32T8/ES (30W) F40T8 120 0.23 27 0.99 60 F / 15 C 230 IOP-1P32-SC 0.12 27 0.87 10 0.98 1 30 277 0.10 27 0.98 120 0.28 33 0.99 60 F / 15 C 230 IOP-2P32-SC 0.15 33 1.05 10 0.98 277 0.12 33 0.98 120 0.44 52 0.99 60 F / 15 C 230 IOP-2P32-SC 0.23 51 0.87 10 0.98 2 30 277 0.19 51 0.98 120 0.50 59 0.99 60 F / 15 C 230 IOP-3P32-SC 0.25 58 1.00 10 0.98 277 0.21 58 0.98 120 0.65 77 0.99 60 F / 15 C 230 IOP-3P32-SC 0.34 76 0.87 10 0.98 3 30 277 0.28 76 0.98 120 0.70 84 0.99 60 F / 15 C 230 IOP-4P32-SC 0.36 83 0.97 10 0.98 277 0.30 82 0.98 120 0.86 102 0.99 4 30 60 F / 15 C 230 IOP-4P32-SC 0.45 101 0.87 10 0.98 277 0.37 100 0.98 120 0.35 41 0.99 1 40 32 F / 0 C 230 IOP-2P32-SC 0.18 41 1.01 10 0.98 277 0.15 41 0.98 120 0.64 74 0.99 2 40 32 F / 0 C 230 IOP-3P32-SC 0.33 73 0.97 10 0.98 277 0.27 72 0.98 120 0.92 110 0.99 3 40 32 F / 0 C 230 IOP-4P32-SC 0.46 108 0.93 10 0.98 277 0.38 107 0.98

ANSI () Ballast F17T8 (17W) 120 0.13 15 0.99-20 F / -28 C 230 IOP-1P32LW-SC 0.07 15 0.80 10 0.97 1 17 277 0.06 15 0.97 120 0.15 18 0.98-20 F / -28 C 230 IOP-2P32LW-SC 0.08 18 0.90 20 0.96 277 0.07 18 0.94 120 0.23 27 0.99-20 F / -28 C 230 IOP-2P32LW-SC 0.12 27 0.80 10 0.97 2 17 277 0.10 27 0.97 120 0.26 31 0.98-20 F / -28 C 230 IOP-3P32LW-SC 0.14 31 0.87 20 0.96 277 0.12 31 0.91 120 0.34 40 0.99-20 F / -28 C 230 IOP-3P32LW-SC 0.18 40 0.81 10 0.97 3 17 277 0.15 40 0.96 120 0.36 43 0.98-20 F / -28 C 230 IOP-4P32LW-SC 0.19 43 0.85 20 0.97 277 0.17 43 0.93 120 0.45 53 0.99 4 17-20 F / -28 C 230 IOP-4P32LW-SC 0.23 53 0.81 10 0.97 277 0.20 53 0.96 F25T8 (25W) 120 0.17 21 0.99-20 F / -28 C 230 IOP-1P32LW-SC 0.09 21 0.78 10 0.98 1 25 277 0.08 21 0.98 120 0.20 24 0.99-20 F / -28 C 230 IOP-2P32LW-SC 0.11 24 0.90 10 0.97 277 0.09 24 0.96 120 0.32 39 0.99-20 F / -28 C 230 IOP-2P32LW-SC 0.17 39 0.78 10 0.98 2 25 277 0.14 39 0.98 120 0.36 43 0.99-20 F / -28 C 230 IOP-3P32LW-SC 0.19 43 0.86 10 0.97 277 0.16 43 0.96 120 0.48 57 0.99-20 F / -28 C 230 IOP-3P32LW-SC 0.25 56 0.79 10 0.98 3 25 277 0.21 56 0.98 120 0.52 62 0.99-20 F / -28 C 230 IOP-4P32LW-SC 0.27 61 0.85 10 0.97 277 0.22 61 0.97 120 0.64 76 0.99 4 25-20 F / -28 C 230 IOP-4P32LW-SC 0.33 75 0.79 10 0.98 277 0.27 75 0.98

ANSI () Ballast F32T8, FBO32T8, F32T8/U6 120 0.22 25 0.99-20 F / -28 C 230 IOP-1P32LW-SC 0.11 25 0.77 10 0.98 1 32 277 0.10 25 0.98 120 0.26 31 0.99-20 F / -28 C 230 IOP-2P32LW-SC 0.14 31 0.90 10 0.98 277 0.11 31 0.98 120 0.41 48 0.99-20 F / -28 C 230 IOP-2P32LW-SC 0.20 48 0.77 10 0.98 2 32 277 0.17 48 0.98 120 0.46 55 0.99-20 F / -28 C 230 IOP-3P32LW-SC 0.24 54 0.85 10 0.98 277 0.20 54 0.98 120 0.62 73 0.99-20 F / -28 C 230 IOP-3P32LW-SC 0.32 72 0.77 10 0.98 3 32 277 0.27 71 0.98 120 0.67 80 0.99-20 F / -28 C 230 IOP-4P32LW-SC 0.35 79 0.84 10 0.98 277 0.29 79 0.98 120 0.81 96 0.99 4 32-20 F / -28 C 230 IOP-4P32LW-SC 0.43 95 0.77 10 0.98 277 0.35 94 0.98 F32T8/ES (25W Philips Lamps) 120 0.17 21 0.99 60 F / 15 C 230 IOP-1P32LW-SC 0.09 21 0.77 10 0.98 1 25 277 0.07 21 0.98 120 0.20 24 0.99 60 F / 15 C 230 IOP-2P32LW-SC 0.11 24 0.90 10 0.97 277 0.09 24 0.96 120 0.32 38 0.99 60 F / 15 C 230 IOP-2P32LW-SC 0.17 38 0.77 10 0.98 2 25 277 0.14 38 0.98 120 0.36 43 0.99 60 F / 15 C 230 IOP-3P32LW-SC 0.19 43 0.86 10 0.97 277 0.16 43 0.96 120 0.49 58 0.99 60 F / 15 C 230 IOP-3P32LW-SC 0.25 57 0.77 10 0.98 3 25 277 0.21 57 0.98 120 0.52 62 0.99 60 F / 15 C 230 IOP-4P32LW-SC 0.27 61 0.85 10 0.97 277 0.22 61 0.97 120 0.65 77 0.99 4 25 60 F / 15 C 230 IOP-4P32LW-SC 0.33 75 0.77 10 0.98 277 0.28 75 0.98

ANSI () Ballast F32T8/ES (28W) 120 0.19 22 0.99 60 F / 15 C 230 IOP-1P32LW-SC 0.10 22 0.77 10 0.98 1 28 277 0.08 22 0.98 120 0.22 26 0.99 60 F / 15 C 230 IOP-2P32LW-SC 0.12 26 0.90 10 0.98 277 0.10 26 0.97 120 0.35 42 0.99 60 F / 15 C 230 IOP-2P32LW-SC 0.19 42 0.77 10 0.98 2 28 277 0.15 42 0.98 120 0.40 47 0.99 60 F / 15 C 230 IOP-3P32LW-SC 0.21 47 0.86 10 0.98 277 0.18 47 0.97 120 0.54 64 0.99 60 F / 15 C 230 IOP-3P32LW-SC 0.28 63 0.77 10 0.98 3 28 277 0.23 63 0.98 120 0.58 69 0.99 60 F / 15 C 230 IOP-4P32LW-SC 0.30 68 0.85 10 0.98 277 0.25 68 0.97 120 0.71 84 0.99 4 28 60 F / 15 C 230 IOP-4P32LW-SC 0.36 82 0.77 10 0.98 277 0.30 82 0.98 F32T8/ES (30W) F40T8 120 0.20 24 0.99 60 F / 15 C 230 IOP-1P32LW-SC 0.11 24 0.77 10 0.98 1 30 277 0.09 24 0.98 120 0.24 28 0.99 60 F / 15 C 230 IOP-2P32LW-SC 0.12 28 0.90 10 0.98 277 0.10 28 0.98 120 0.38 45 0.99 60 F / 15 C 230 IOP-2P32LW-SC 0.20 45 0.77 10 0.98 2 30 277 0.17 45 0.98 120 0.43 51 0.99 60 F / 15 C 230 IOP-3P32LW-SC 0.23 51 0.85 10 0.98 277 0.19 51 0.98 120 0.57 68 0.99 60 F / 15 C 230 IOP-3P32LW-SC 0.30 67 0.77 10 0.98 3 30 277 0.25 67 0.98 120 0.63 75 0.99 60 F / 15 C 230 IOP-4P32LW-SC 0.32 74 0.84 10 0.98 277 0.27 74 0.98 120 0.76 90 0.99 4 30 60 F / 15 C 230 IOP-4P32LW-SC 0.40 88 0.77 10 0.98 277 0.33 88 0.98 120 0.29 35 0.99 1 40 32 F / 0 C 230 IOP-2P32LW-SC 0.16 35 0.87 10 0.98 277 0.13 35 0.98 120 0.58 67 0.99 2 40 32 F / 0 C 230 IOP-3P32LW-SC 0.30 66 0.85 10 0.98 277 0.25 66 0.98 120 0.82 98 0.99 3 40 32 F / 0 C 230 IOP-4P32LW-SC 0.43 96 0.84 10 0.98 277 0.35 96 0.98

Optanium Ballast Specifications Section I - Physical Characteristics 1.1 The electronic ballast shall be physically interchangeable with standard electromagnetic and standard electronic ballasts. 1.2 The electronic ballast shall be furnished with integral leads, color-coded to ANSI C82.11. Section II - Performance Requirements 2.1 Ballast shall be Instant Start or Programmed Start. 2.2 Instant Start ballast shall provide Independent Lamp Operation (ILO) for allowing remaining lamp(s) to maintain full light output when one or more lamp fails. Programmed Start ballast shall provide semi-independent lamp operation. 2.3 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power. 2.4 Ballast shall operate from 50/60 Hz input source of 120V through 277V with sustained variations of +/-10% (voltage and frequency) with no damage to the ballast. 2.5 Ballast shall be high frequency electronic type and operate at a frequency above 42 khz through 52 khz to minimize interference with infrared control systems and eliminate visible flicker. 2.6 Ballast shall have a Power greater than 0.98 for primary lamp. 2.7 Ballast shall have a minimum ballast factor for primary lamp application as follows: 0.77 or 0.71 for Low Watt, 0.87 or 0.88 for Normal Light Output, and 1.18 for High Light. 2.8 Ballast shall provide for a Lamp Current Crest of 1.7 or less in accordance with lamp manufacturer recommendations. 2.9 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp. 2.10 Ballast shall have a Class A sound rating for all 4-foot lamps and smaller. WHITE BLACK BALLAST WHITE BLACK BALLAST 2.11 Ballast shall have a minimum starting temperature of -20 F (-29 C) or 0 F (-18 C) for standard T8 lamps and 60 F (16 C) for energy-savings T8 lamps. 2.12 Ballast shall tolerate sustained open circuit and short circuit output conditions without damage. 2.13 Ballast shall contain an anti-striation circuitry to prevent striation on energy-savings lamps. 2.14 Programmed Start ballast shall provide lamp EOL Protection Circuitry Section III - Regulatory Requirements 3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB). 3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P, and Type 1 Outdoor; and Canadian Standards Association (CSA) certified, where applicable. 3.3 Ballast shall comply with ANSI C62.41 Category A for Transient protection. 3.4 Ballast shall comply win ANSI C82.11, where applicable. 3.5 Ballast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI (conducted and radiated). 3.6 Ballast shall comply with UL Type CC rating. 3.7 Ballast shall meet NEMA/CEE high performance T8 lighting system specificatio. Section IV - Other 4.1 The electronic ballast shall be produced in a factory certified to ISO 9002 Quality System Standards. 4.2 The electronic ballast shall carry a five-year warranty from the date of manufacture against defects in material or workmanship, including replacement for operation at a maximum case temperature of 70 C. Ballasts with a 90 C designation in their catalog number shall also carry a three-year warranty at a maximum case temperature of 90 C. 4.3 The manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market. LINE 1 - Lamp Operation LINE 2 - Lamp Operation WHITE BLACK BALLAST WHITE BLACK YELLOW YELLOW BALLAST 1.18" 8.90" 9.5" LINE LINE 1.7" 3 - Lamp Operation 4 - Lamp Operation Advance 10275 W. Higgins Road Rosemont, IL 60018 Tel: 800-322-2086 Fax: 888-423-1882 Customer Support/Technical Service: 800-372-3331 www.advancetransformer.com As a Licensee in the NEMA Premium Electronic Ballast Program, Advance has determined that this product meets the NEMA Premium Efficiency specifications for premium energy efficiency. 2008 Advance, A Division of Philips Electronic North America All rights reserved. Reproduction in whole or part is prohibited without the prior written consent of the copyright owner. The information presented in this document, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the published for any consequences of its use. Publication thereof does not convey nor imply any license under patent or other industrial or intellectual property rights. Form No. EL-2153-R07 1/08