R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Similar documents
R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Solid Dielectric, Single Phase Recloser

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Cobra-S. Catalog Cobra-S

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Air-insulated switchgear UniGear type ZS1

Solid Dielectric, Single Phase Reclosers

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Type SDV7 distribution circuit breaker family

Horizontal Circuit Switchers

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7

Outdoor vacuum breaker for railway applications - FSK II

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

SafeGear TM Motor Control Center Arc resistant metal-clad construction

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Horizontal Circuit Switchers

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

OVR Three Phase Recloser 15 kv - 38 kv. Descriptive Bulletin

R-MAG Medium Voltage Outdoor Dead Tank Vacuum Magnetic Circuit Breaker

AutoLink Frequently Asked Questions

Advance 27 ANSI 27 kv switchgear

GROUP D. Switch & Protective device.

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

Product Group Brochure. PS Range Capacitor Vacuum Switches

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

EE 741 Over-voltage and Overcurrent. Spring 2014

Contactor V-Contact VSC/P

Solid Dielectric, Three Phase Reclosers CATALOG VS11

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

Type SDV7 distribution circuit breaker family Answers for energy.

Outdoor Padmount Switching Products

Padmount Solid Dielectric Switchgear Catalog

Medium Voltage Outdoor Apparatus Portfolio 2009

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

solutions RUS accepted

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

B4 Load Break Switches

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

SWITCHGEAR DIVISION PRODUCT PROFILES

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

Publication No.: PSG

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

FEBRUARY 14, 2017 Joslyn Hi-Voltage Capacitor switches customer presentation

Solid Dielectric, Triple Option Reclosers Catalog O-vst14

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

Solid Dielectric, Independent Pole Operated Reclosers Catalog O-vst16

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Solid Dielectric, Three Phase Reclosers Catalog O-vs18

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

Medium Voltage Metal-Enclosed Switches

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

A Summary of Major Improvements to the ABB Recloser and Type R Breaker

Transformer bushings, type GOH. Technical guide

Q pole Pole Mounted Capacitor System

3TM Vacuum Contactors

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

B kv T&D GAS INSULATED SWITCHGEAR

CPG.0 Single busbar gas-insulated cubicles

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Medium Voltage Metal-Enclosed Switches

RUS accepted Catalog O-vst18

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

Unified requirements for systems with voltages above 1 kv up to 15 kv

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Transmission Switching

Power/Vac OEM Express Switchgear

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

Power/Vac Vacuum Replacement Breakers for GE Magne-Blast Type AM & AMH Breakers

We build a better future!

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

DPX earth leakage DPX 3 -I earth leakage

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

CP Automatic capacitor bank

NXPLUS C Single busbar. Maintenance-free for lifetime

Transcription:

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A - 3700 A

R-MAG The R-MAG is truly the next generation in vacuum circuit breakers, combining industry recognized magnetic actuation technology with a culture that embraces the production of safe, dependable products. ABB makes safety our first priority by employing magnetic actuators to eliminate maintenance on coils, motors, and mechanically charged springs that could result in injuries to field personnel. R-MAG benefits include: Simple, Less Frequent Maintenance - Rated for 10,000 full load operations (five times ANSI requirements) - No maintenance required on magnetic actuator - Plug & play actuator circuitry - Vacuum interrupters rated for 30,000 full load operations Increased Reliability - Magnetic actuator has only one moving part - No spring charging motors to replace - No trip/close coils to replace - Meets BIL requirements without using inter-phase barriers (barrier boards) that can degrade over time Safety - Less moving parts = less maintenance = fewer operator injuries Increased Performance - Definite purpose capacitor switching in accordance with ANSI C37.06-15.5 kv - 3000 A rated continuous current without forced air cooling - 15.5 kv - 3700 A rated continuous current with forced air cooling R-MAG circuit breakers have been fully tested to the most recent versions of ANSI C37.04, C37.06, C37.09 and IEC 62271. Available for 15 and 27 kv applications, this next generation circuit breaker offers solutions for many applications. 2 ABB

R-MAG. The circuit breaker. Breaker Evolution - Matching optimum technologies 27 kv 15 kv Although many refinements have been made throughout the 80 year history of the outdoor circuit breaker, there have only been three generations of circuit breaker design. Early circuit breaker mechanisms were spring charged with separate close and trip springs used for oil breakers. The second generation of breakers used this same mechanism, modified for vacuum interruption. The new R-MAG generation of circuit breakers uses a magnetic actuator mechanism with vacuum interrupters. Each generation reflects the best technology available at the time of their introduction, building on the strengths of previous designs, while adding new innovations. Although it is well established that vacuum interrupters are capable of more than 10,000 operations, conventional stored energy mechanisms seldom operate beyond 500 operations without maintenance, re-lubrication, or replacement of parts. The main disadvantage of stored energy mechanisms is the large number of precision moving parts required to perform spring charging, closing and tripping functions. Conventional stored energy breakers also place limitations on the types of control voltages allowed. The R-MAG is truly the next generation in medium voltage vacuum circuit breaker technology. ABB is the first to combine the unique requirements of vacuum interrupter technology with a magnetic actuator designed to exploit these capabilities. Using a flux-shifting device with integral permanent magnets, the R-MAG mechanism has only one moving part. With simple open and close coils, an electronic controller and capacitors for energy storage, the R-MAG circuit breaker mechanism is capable of 10,000 operations. These are merely a few of the features that mark a departure from the conventional spring operated mechanism, introducing new capabilities and benefits for modern power systems. ABB 3

R-MAG Summary of benefits: Simple mechanical operation Actuator has only one moving part Manual opening capability High reliability The magnetic actuator, electronic controller and capacitors are the key components for this next generation product. The magnetic actuator has a magnetic frame assembly, two identical operating coils, two rare earth magnets and a single moving armature. Instead of mechanical assemblies for armature position sensing, proximity sensors detect armature position for the electronic controller. These permanent magnets will retain 99% of their flux density for more than 100 years. Extended life capacitors, used as stored energy devices, drive the actuator, minimizing the inrush current from the source. These special capacitors charge in as little as seven seconds after control power is available, and are "trickle charged" by the electronic controller as needed. Covers over the capacitor terminals prevent accidental contact. The magnetic actuator and control components are mounted in the low voltage compartment. All components at line potential are contained in the high voltage section and are completely isolated from the control compartment. Insulating entrance bushings are attached to the roof assembly by bolt and compression type clamps. Removal or replacement does not disturb the existing breaker adjustments. Bushing current transformers mount on the entrance and/or exit bushings. The accuracy class required determines the number of current transformers that may be mounted. All Type R-MAG circuit breakers use flexible shunt connectors. The R-MAG circuit breaker is designed to provide many years of trouble free service for the end user. 4 ABB

R-MAG. Circuit-breaker of the high tech generation. Construction of a vacuum interrupter Stem Twist protection Metal bellows End cap Bellows shield Ceramic insulator Vacuum Interrupter The conduction and interruption of short-circuit currents places great demands on vacuum interrupters. The robust construction of the ABB vacuum interrupters ensures fault-free and maintenance-free operation for decades. Control Wiring Auxiliary control relays and the electronic control module are mounted on panels located in the low voltage compartment. Fused switches protect control circuits. All bushing current transformer connections are wired to shorting type terminal blocks in the low voltage compartment. Main shield Contacts Stem End plate 30,000 operations at load current Electronic Controller The electronic controller uses robust components and a conformal coating to prolong the life of the device. The electronic controller will operate on AC or DC control power because it internally utilizes an AC to DC converter. Instead of selecting from a long list of control power options, the user only needs to select a controller for the low voltage range control power (20.4-52.8 VAC or 16.8-75 VDC) or a controller for the high voltage range control power (85-264 VAC or 77-280 VDC). Inside these ranges, the user may apply any value of direct current, or any value of 50 or 60 cycle alternating current to achieve circuit breaker operation. The electronic controller incorporates all capacitor charging, open/close coil switching, anti-pumping, interlocking and armature position details. Programmed self-monitoring functions monitor proximity sensors, coil continuity, capacitor voltage and other key functions. Surge Withstand and Electromagnetic Capability tests have been successfully performed per IEC 61000 standards. Only six watts of energy are needed to maintain controller functions and capacitor full charge. There is an optional 33 watt setting that extends the charging time, which is suitable for smaller batteries or power sources. For normal operation, the minimum requirement of the auxiliary power supply is 93 watts. Contact ABB for details. Life curve of 25 ka vacuum interrupters ABB 5

R-MAG. Low maintenance permanent magnet technology. Instantaneous representation of magnetic flux density distribution Following the advance of vacuum interruption in the field of medium voltage circuit breakers in the last 20 years, a natural amalgamation of technology has been achieved with the addition of magnetic actuator technology. The requirements of one technology optimally match the opportunities of the other. Magnetic actuator technology naturally provides the suitable travel-time and force-travel characteristics for the vacuum switching devices. All operating mechanism functions are integrated in the magnetic actuator of the R-MAG circuit breaker. The actuator is a bistable magnet system, in which armature change-of-state is accomplished by the magnetic field of two electrically excited coils. The armature is held magnetically in the limit positions by the fields of two rare-earth permanent magnets. Switching operations are achieved by excitation of one of the two coils until the retaining force of the permanent magnets is exceeded. Even after complete failure of the auxiliary power, the energy stored in the capacitors will allow electrical operation for 200 seconds. In the event of complete loss of control power, the circuit breaker can be tripped manually. The armature of the magnetic actuator is linked to an operating shaft connected via insulated push rods to each of the vacuum interrupters. The only points of lubrication for this mechanism are at the union of the armature to the operating shaft, the pivot points of the operating shaft and the pivot points of the operating shaft to the push rods. Long life synthetic lubricants are applied during assembly to further reduce the need for lubrication during the life of the circuit breaker. Magnetic latching in a limit position Magnetic latching plus current build up in one coil Armature reaching the opposite limit position 6 ABB

R-MAG technical data. Rated Maximum Voltage (kv RMS) 15.5 15.5 15.5 15.5 27 27 27 Rated Continuous Current (A RMS) 1200 1200 1200/2000 1200/2000/3000 1 /3700 2 1200 1200/2000 1200/2000 Rated Voltage Range Factor K*** 1 1 1 1 1 1 1 Rated Power Frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Rated Power Frequency Withstand Dry 60 Hz for 1 Min (kv RMS) 50 50 50 50 60 60 60 Wet 60 Hz for 10 Sec (kv RMS) 45 45 45 45 50 50 50 Rated Lightning Impulse Withstand Voltage (BIL - kv peak) 110 110 110 110 125/150 125/150 125/150 Rated Chopped Wave Impulse Withstand Voltage (kv peak) Rated Standard Operating Duty (Standard Duty Cycle) 142 142 142 142 NA/194 NA/194 NA/194 Exceeds ANSI standard, will meet O-0.3 sec-co-15 sec-co Rated Interrupting Time (cycles) 3 3 3 3 3 3 3 Maximum Permissible Tripping Delay Y (sec) 2 2 2 2 2 2 2 Closing Time (cycles) 6 6 6 6 6 6 6 Reclosing Time (sec) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 Rated Short Circuit Interrupting Current at Contact Part (ka RMS, Sym) 12.5 16 20 25 12.5 20 25 Close & Latch Initial Current Loop (ka RMS, Asym) 20 25.6 32 40 20 32 40 Rated Close & Latch (ka peak) 32.5 41.6 52 65 32.5 52 65 Rated Short Time Current - 3 sec (ka RMS, Sym) Rated Transient Recovery Voltage (kv peak) Load Current Switching Capability (A RMS) Rated Overhead Line Switching Current (A RMS) Rated Isolated Cable Switching Current (A RMS) Rated Isolated Shunt Capacitor Bank Switching Current (A RMS) Rated Back-to-Back Cable Switching Current (A RMS) Rated Back-to-Back Shunt Capacitor Bank Switching Current (A RMS) Rated Transient Overvoltage Factor Rated Back-to-Back Transient Inrush Current (ka Peak) Rated Back-to-Back Transient Inrush Frequency (Hz) Grounding of System and Capacitor Bank System Capacitor Bank Mechanical Life (No Load Operations) 12.5 16 20 25 12.5 20 25 29 29 29 29 51 51 51 1200 1200 1200/2000 1200/2000/3000 1 /3700 2 1200 1200/2000 1200/2000 100 100 100 100 100 100 100 600 600 600 600 400 400 400 600 600 600 600 600 600 600 600 600 600 600 400 400 400 600 600 600 600 600 600 600 3.0* 3.0* 3.0* 3.0* 3.0* 3.0* 3.0* 2.5** 2.5** 2.5** 2.5** 2.5** 2.5** 2.5** 20 20 20 20 20 20 20 4240 4240 4240 4240 4240 4240 4240 Grounded or Ungrounded Grounded or Ungrounded 10,000 10,000 10,000 10,000 10,000 10,000 10,000 1 up to 3000 A without forced air cooling 2 3700 A with forced air cooling * General purpose ** Definite purpose ABB 7

ABB Inc. 655 Century Point Lake Mary, FL 32746 U.S.A. For sales & marketing contact your local representative or: Tel: +1-407-732-2000 1-800-929-7947 Fax: +1-407-732-2029 www.abb.com/mediumvoltage 1VAL255101-DB April 2009 Rev I (replaces DB38-921M)