HIGH VOLTAGE LABORATORY INSTYTUT ENERGETYKI

Similar documents
Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

PowerIT Indoor Voltage Transformer Fuses, WBP. Outdoor Voltage Transformer Fuses, BRT. Catalogue 1YMB en. Industrial IT.

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Transformer bushings, type GOH. Technical guide

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

PHOENIX CONTACT

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

CATALOGUE. ON Medium Voltage Outdoor Disconnectors

Current accuracy class. Sensor principles

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Motorized switch-disconnectors OTM 40 to 125 Amperes

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Electronic overload relays EF205 and EF370

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

KOLMA and IHDA Indoor Type Cable Current Transformers. Catalogue. Catalogue KOLMA 1 GB Medium Voltage. ABB Transmit KKOLMA 1 GB

Miniature circuit-breaker (MCB) SH200M Series

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Compact Integrated Distribution Substation (CIDS)

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Electronic overload relay EF65, EF96 and EF146

Mini contactors B6, BC6 with 3 pole

Surge arrester POLIM-H..SD

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Current transformers. Current transformers

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

Medium voltage fuses - European Fuses

On-load tap-changer OILTAP V

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

ZX-Family Gas-insulated medium voltage switchgear

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

CP Automatic capacitor bank

High-voltage high-breaking capacity VV fuse-links

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

High voltage current limiting Fuse links type CEF

Company Overview. Since 1975 in the sector, solid experience of design and production of dry type electric transformers and inductances

Technical Specification of GECOL. Packaged Transformers

MESG 12 / 17.5 / 24 / 36 KV

B kv Gas-insulated Substations

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

Prüffeld der Schaltwerke

MS General Information Extended Product Type: MS

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

HMI, APRIL, Test Laboratories in Ratingen

High-Voltage Fuse Links according to IEC

Air-insulated switchgear UniGear type ZS1

Current sensor. Instructions for installation, use and maintenance. Type KECR 17,5 AC1 ABB

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H. form A contact (normally open) for PCBs

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A


CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

Panel SCCR 50kA RMS Symmetrical 480V Maximum

Technical Data Accessories MCBs Ex9B.

TEKNISK RIKTLINJE TR05-10E

KECA 80 C85 Current Sensor Instructions for installation, use and maintenance

Scheda prodotto Relè Series E

Technical information

Application Note: Protection of Medium-Power Motors With SIPROTEC Compact 7SK80

Ultra Fast Earthing Switch UFES retrofit Overview

Semiconductor (AC) fuses

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7

PROTECTION AND CONNECTION. ABB Compact ATS Compact without compromise

EMPAC Metal enclosed capacitor bank for wind applications

FUSES. Safety through quality

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Surge Arresters. Supply Program. Answers for energy.

AS/NZS AS/NZS

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Surge arrester POLIM-H.. ND

AC/DC Arc Furnace and Ladle Furnace Transformers

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance

شركة كهرباء محافظة القدس المساهمة المحدودة

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

Bistable Relay. Types PSU6n, PSU14n.

Transcription:

HIGH VOLTAGE LABORATORY INSTYTUT ENERGETYKI POLAND 01-330 WARSZAWA, ul. Mory 8, tel. (+48 22) 836-80-48, fax (+48 22) 836-80-48 e-mail: ewn@ien.com.pl EWN/70/E/11-1 APPENDIX 3 APPENDIX 3 for test report EWN/70/E/11-1 Report of performed tests in Distribution Equipment Laboratory of Institute of Power Engineering in Warsaw. Test Report No. EUR/33/E/11-1E of 25.07.2011 Test Report No. EUR/33/E/11-2E of 10.08.2011 (Short-time current tests, short-circuit withstand capability test and mechanical.)

EUR/33/E/11-2E Page 2/16 Contents Page 1. Test object 3 1.1. Description 3 1.2. Technical data 3 1.3. Technical documentation 3 1.4. Preparation for tests 3 2. Scope of tests 3 3. Test and measuring circuits 4 4. Tests and theirs detailed results 7 5. Test results evaluation 8 Annexes: 1. Short-circuit test records 2. Photographs taken during the tests 3. Documentations delivered by orderer 9 10 15 Report contents: numbered pages 16 records (pages not numbered) 5 tables 3 figures 3 photographs 10

EUR/33/E/11-2E Page 3/16 1. TEST OBJECT 1.1 Description Combined transformer type PVA 123 is used for supplying of measuring and protection circuits in the network of nominal voltage 110 kv and frequency 50 Hz. The transformer consists of current and voltage transformers mounted in common porcelain enclosure immersed with transformer oil. 1.2 Technical data The Manufacturer attributed the following construction data to the test object. Rated voltage Rated frequency Rated continuous thermal current Rated short-time current Rated dynamic current Rated static load 110/ 3 kv 50 Hz 50 A, 100 A, 200 A 10 ka, 20 ka, 40 ka 25 ka, 50 ka, 100 ka 3600 N 1.3 Technical documentation For the purpose of tests the orderer delivered the following technical documentation: - dimension drawing of combined transformer PVA 123, No.2GKK 610211, ABB Sp. z o.o., 12.07.2011 (Annex 3), - electrical diagram of combined transformer PVA 123, ABB Sp. z o.o., 25.07.2011 (Annex 3). The laboratory proceeded the identification of test object on the base of above documentation and the nameplate. 1.4 Preparation for tests The test object was prepared for test by factory. 2. SCOPE OF TESTS Test program, agreed with orderer, comprised the following tests according to requirements of EN 60044-3:2003 (idt IEC 60044-3:2002): - short-time current tests of current transformer windings acc. to item 6.2 a) of above standards at the following parameters: for 50 A: I dyn 25 ka, I th = 10 ka t th = 1 s, I th 2 t th 100 ka 2 s, for 100 A: I dyn 50 ka, I th = 20 ka t th = 1 s, I th 2 t th 400 ka 2 s, for 200 A: I dyn 100 ka, I th = 40 ka t th = 1 s, I th 2 t th 1600 ka 2 s, - short-circuit withstand capability test of voltage transformer acc. to item 6.2 f) of above standards at parameters: U p 63,5 kv, t p = 1 s, - mechanical tests acc. to item 6.4 d) of above standards for F R = 3600 N and resulting dynamic load of terminals P1 and P2/A 200 A.

EUR/33/E/11-2E Page 4/16 3. TEST AND MEASURING CIRCUITS For the tests the transformer was fixed to the rigid construction of the test stand. Short-time current tests were made in one phase circuit presented on fig. 1 and 2. Short-circuit withstand capability tests were made in test circuit presented on fig. 3. Mechanical tests were performed applying the load consecutively to the transformer s terminals as shown on photographs 5 to 10 in Annex 2. The following quantities were recorded during the tests using digital recorder type HIOKI 8842: - primary current of current transformer (with short-circuited all secondary terminals) during short-time current tests using laboratory current transformer type CdC class 0,5 with a ratio 50.000/2 A/A, - primary voltage and current, secondary current in short-circuited windings: 1a-1n (next da-dn) during short-circuit withstand capability tests of voltage transformer using: - inductive voltage transformer type U110a class 0,5 with a ratio 110/ 3/0,1/ 3 kv/kv for primary voltage measurement, - laboratory current transformer type GE 4461 class 0,2 with a ratio 5/5 A/A for primary current measurement, - laboratory current transformer type IL 20a class 0,5 with a ratio 2.000/5 A/A for secondary currents measurements. 3600 mm 1400 mm 1000 mm 2 AFL-8 525 mm 2 AL 1000 mm 2 2330 mm 3600 mm 3300 mm Fig. 1. Configuration of test circuit during short-time current tests

EUR/33/E/11-2E Page 5/16 110 kv L1 L2 T CB T - short-circuit transformer CB - back-up circuit-breaker R - reactor MS - make switch CT - current transformer TO - test object R MS CT Recorder HIOKI 8842 TO Fig.2. Test and measuring circuits during short-time current tests

EUR/33/E/11-2E Page 6/16 L1 L2 System 110 kv L3 WB110 PN PP2 1a 1n Recorder HIOKI 8842 PP2 da dn PP1 WB110 - back-up circuit-breaker PN - voltage transformer PP1, PP2 - current transformers Fig. 3. Test and measuring circuits during short-circuit withstand capability tests

EUR/33/E/11-2E Page 7/16 4. TESTS AND THEIRS DETAILED RESULTS Mechanical tests were performed 05.07.2011 and short-circuit tests - in the nights 19/20.07, 08/09.08.2011. Tests results present tables 1, 2 and 3. During the tests the following records were made: - No. 30696 calibration of measuring circuit, - Nos. 30697, 30698 short-circuit withstand capability tests, - Nos. 30725, 30727, 30729 calibration of test circuit, - Nos. 30726, 30728, 30730 short-time current tests, (Annex 1 presents the copies of short-circuit test records - all records are stored in laboratory s archives), - phot. 1 to 4 combined transformer on short-circuit tests stand, - phot. 5 to 10 - combined transformer during mechanical tests (Annex 2 presents the photographs). Table 1. Results of static load withstand tests at F = 3620 N and dynamic *) Test Load Test Terminal Observations No. direction time - - - s - 1 2 3 4 5 6 7 8 9 10 P1 P1 P1 P1 P1 P1 P2/A P2/A P2/A P2/A transverse transverse vertical vertical longitudinal longitudinal transverse transverse vertical vertical 60 dyn. *) 60 dyn. *) 60 dyn. *) 60 dyn. *) 60 dyn. *) After tests no damage nor oil leak was stated. After tests no damage nor oil leak was stated. After tests no damage nor oil leak was stated. After tests no damage nor oil leak was stated. After tests no damage nor oil leak was stated. 11 P2/A longitudinal 60 After tests no damage nor oil leak was stated. 12 P2/A longitudinal dyn. *) Remark: *) Dynamic tests were performed by sudden loading the terminal by the weight 3620 N.

EUR/33/E/11-2E Page 8/16 Table 2. Results of short-circuit withstand capability tests (t amb = 20 C) Test No. Terminals U z I PS I SS t z Observations - kv A A s - 30697 1a 1n 65,4 1) 0,6 633 1,0 After tests no damage nor oil leak was stated. 30698 da - dn 65,5 1) 0,4 716 1,0 After tests no damage nor oil leak was stated. Legend: U z - test voltage I PS - r.m.s. value of primary side test current I SS - r.m.s. value of secondary side test current t z - test duration 1) - required U z 63,5 kv Table 3. Results of short-time current tests (t amb = 16 C) Test No. Term. i pesk I z t z I z 2 t z Observations - - ka ka s (ka) 2 s - 30726 50 A 27,0 1) 10,4 1,0 108 2) After tests no damage nor oil leak was stated. 30728 100 A 54,4 3) 20,8 1,0 432 4) After tests no damage nor oil leak was stated. 30730 200 A 102,7 5) 40,5 1,0 1640 6) After tests no damage nor oil leak was stated. Legend: i peak - peak value of test current - r.m.s. value of test current I z t z - test duration Required : 1) - i peak 25 ka, 2) - I 2 z t z 100 (ka) 2 s 3) - i peak 50 ka, 4) - I 2 z t z 400 (ka) 2 s 5) - i peak 100 ka, 6) - I 2 z t z 1600 (ka) 2 s 5. TESTS RESULTS EVALUATION According to criteria given in EN 60044-3:2003 (idt IEC 60044-3:2002) p. 6.2 a), 6.2 f) i 6.4 d) the results of tests of tested combined transformer is positive for: - I th = 10 ka, I dyn = 25 ka for 50 A terminal, - I th = 20 ka, I dyn = 50 ka for 100 A terminal, - I th = 40 ka, I dyn = 100 ka for 200 A terminal, - 63,5 kv at short-circuit in secondary circuits of voltage transformer, - F R = 3600 N and resulting dynamic load.

EUR/33/E/11-2E Page 9/16 ANNEX 1 Test records As not numbered pages the following copies of records are given: 30697, 30698 voltage transformer tests 30726, 30728, 30730 current transformer tests Denotations: u 110 test voltage during voltage transformer tests i N test current on primary side of VT i 1a-1n, i da-dn test current on secondary side of VT i test current during current transformer tests

EUR/33/E/11-2E Page 10/16 ANNEX 2 Photographs taken during the tests Phot. 1. PVA 123 after short-time current tests of VT Phot. 2. PVA 123 after short-circuit withstand capability tests of CT 50 A

EUR/33/E/11-2E Page 11/16 Phot. 3. PVA 123 after short-circuit withstand capability tests of CT 100 A Phot. 4. PVA 123 after short-circuit withstand capability tests of CT 200 A

EUR/33/E/11-2E Page 12/16 Phot. 5. Transverse load of terminal P1 Phot. 6. Transverse load of terminal P2/A 200 A

EUR/33/E/11-2E Page 13/16 Phot. 7. Vertical load of terminal P1 Phot. 8. Vertical load of terminal P2/A 200 A

EUR/33/E/11-2E Page 14/16 Phot. 9. Longitudinal load of terminal P1 Phot. 10. Longitudinal load of terminal P2/A 200 A

EUR/33/E/11-2E Page 15/16 ANNEX 3 Documentations delivered by orderer

EUR/33/E/11-2E Page 16/16

EUR/33/E/11-1E Page 2/13 Contents Page 1. Test object 3 1.1. Description 3 1.2. Technical data 3 1.3. Technical documentation 3 1.4. Preparation for tests 3 2. Scope of tests 3 3. Test and measuring circuits 3 4. Tests and theirs detailed results 5 5. Test results evaluation 6 Annexes: 1. Short-circuit test records 2. Photographs taken during the tests 3. Documentations delivered by orderer 7 8 12 Report contents: numbered pages 13 records (pages not numbered) 2 tables 2 figures 2 photographs 7

EUR/33/E/11-1E Page 3/13 1. TEST OBJECT 1.1 Description Combined transformer type PVA 123 is used for supplying of measuring and protection circuits in the network of nominal voltage 110 kv and frequency 50 Hz. The transformer consists of current and voltage transformers mounted in common composite enclosure immersed with transformer oil. 1.2 Technical data The Manufacturer attributed the following construction data to the test object. Rated voltage Rated frequency Rated continuous thermal current Rated short-time current Rated dynamic current Rated static load 110/ 3 kv 50 Hz 3000 A 63 ka 158 ka 3600 N 1.3 Technical documentation For the purpose of tests the orderer delivered the following technical documentation: - dimension drawing of combined transformer PVA 123, No.2GKK 610212, ABB Sp. z o.o., 12.07.2011 (Annex 3), - electrical diagram of combined transformer PVA 123, ABB Sp. z o.o., 25.07.2011 (Annex 3). The laboratory proceeded the identification of test object on the base of above documentation and the nameplate. 1.4 Preparation for tests The test object was prepared for test by factory. 2. SCOPE OF TESTS Test program, agreed with orderer, comprised the following tests according to requirements of EN 60044-3:2003 (idt IEC 60044-3:2002): - short-time current tests of current transformer acc. to item 6.2 a) of above standards at parameters: I dyn 158 ka, I th = 63 ka t th = 1 s, I th 2 t th 3969 ka 2 s, - mechanical tests acc. to item 6.4 d) of above standards for F R = 3600 N and resulting dynamic load. 3. TEST AND MEASURING CIRCUITS For the tests the transformer was fixed to the rigid construction of the test stand. Short-time current tests were made in one phase circuit presented on fig. 1 and 2. Mechanical tests were performed applying the load consecutively to the transformer s terminals as shown on photographs 2 to 7 in Annex 2. The following quantities were recorded during the tests using digital recorder type HIOKI 8842: primary current of current transformer (with short-circuited all secondary terminals) during short-time current tests using laboratory current transformer type CdC class 0,5 with a ratio 100.000/2 A/A

EUR/33/E/11-1E Page 4/13 110 kv L1 L2 T CB T - short-circuit transformer CB - back-up circuit-breaker R - reactor MS - make switch CT - current transformer TO - test object R MS CT Recorder HIOKI 8842 TO Fig.1. Test and measuring circuits during short-time current tests

EUR/33/E/11-1E Page 5/13 3600 mm 1400 mm 1000 mm 2 AFL-8 525 mm 2 AL 1000 mm 2 2330 mm 3600 mm 3300 mm Fig. 2. Configuration of test circuit during short-time current tests 4. TESTS AND THEIRS DETAILED RESULTS Short-circuit tests were performed in the night 19/20.07.2011 and mechanical tests - 29.06.2011. Tests results present tables 1 and 2. During the tests the following records were made: - No. 30688 calibration of measuring circuit, - Nos. 30689, 39690 calibration of test circuit, - No. 30691, 30692 short-time current tests, (Annex 1 presents the copies of short-circuit test records - all records are stored in laboratory s archives), - phot. 1 combined transformer on short-circuit tests stand, - phot. 2 to 7 - combined transformer during mechanical tests (Annex 2 presents the photographs). Table 1. Results of short-time current tests (t amb = 20 C) Test No. i pesk I z t z I z 2 t z Observations - ka ka s (ka) 2 s - 30691 95,5 63,7 1,01 4098 1) was correct. After tests no damage nor oil Behaviour of transformer during the tests leak was stated. 30592 159,2 2) 63,9 0,06 - Behaviour of transformer during the tests was correct. After tests no damage nor oil leak was stated. Legend: i peak - peak value of test current - r.m.s. value of test current I z t z - test duration Required : 1) - I 2 z t z 3969 (ka) 2 s 2) - i peak 158 ka

EUR/33/E/11-1E Page 6/13 Table 2. Results of static load withstand tests at F = 3620 N and dynamic *) Test Load Test Terminal Observations No. direction time - - - s - 1 2 3 4 5 6 7 8 9 10 11 12 P1 P1 P1 P1 P1 P1 P2/A P2/A P2/A P2/A P2/A P2/A transverse transverse vertical vertical longitudinal longitudinal transverse transverse vertical vertical longitudinal longitudinal 60 dyn. *) 60 dyn. *) 60 dyn. *) 60 dyn. *) 60 dyn. *) 60 dyn. *) Behaviour of transformer during the tests was correct. After tests no damage nor oil leak was stated. Behaviour of transformer during the tests was correct. After tests no damage nor oil leak was stated. Behaviour of transformer during the tests was correct. After tests no damage nor oil leak was stated. Behaviour of transformer during the tests was correct. After tests no damage nor oil leak was stated. Behaviour of transformer during the tests was correct. After tests no damage nor oil leak was stated. Behaviour of transformer during the tests was correct. After tests no damage nor oil leak was stated. Remark: *) Dynamic tests were performed by sudden loading the terminal by the weight 3620 N. 5. TESTS RESULTS EVALUATION According to criteria given in EN 60044-3:2003 (idt IEC 60044-3:2002) p. 6.2 a), and 6.4 d) the results of tests of tested combined transformer is positive for: - I th = 63 ka, I dyn = 158 ka for current transformer, - F R = 3600 N and resulting dynamic load..

EUR/33/E/11-1E Page 7/13 ANNEX 1 Test records As not numbered pages the following copies of records are given: 30690, 30691 current transformer tests Denotations: i test current

EUR/33/E/11-1E Page 8/13 ANNEX 2 Photographs taken during the tests Phot. 1. PVA123 after short-time current tests of CT

EUR/33/E/11-1E Page 9/13 Phot. 2. Transverse load of terminal P1 Phot. 3. Transverse load of terminal P2/A

EUR/33/E/11-1E Page 10/13 Phot. 4. Vertical load of terminal P1 Phot. 5. Vertical load of terminal P2/A

EUR/33/E/11-1E Page 11/13 Phot. 6. Longitudinal load of terminal P1 Phot. 7. Longitudinal load of terminal P2/A

EUR/33/E/11-1E Page 12/13 ANNEX 3 Documentations delivered by orderer

EUR/33/E/11-1E Page 13/13