Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

Similar documents
Solenoid drive. Operating instructions

Ex m Solenoid Operator Type 0519

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

Solenoid Operator 0516 / 1216

Technical Data. Dimensions

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Solenoid Operator 0513 / 1213

Solenoid coil for control in potentially explosive areas Type BZ

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

3/2 and 4/2 directional seat valves with solenoid actuation

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Solenoid coils VACF Type codes

SERIES 54 Inductive Proximity Sensor

Mechanical Operating Instructions

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Operating Instructions

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

OPERATING INSTRUCTIONS

Directional Control Valve Series D1VW

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

Installation and Operating Instructions

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Solenoid Valves Type 3963

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Electromagnetic Flow Monitor magphant

Installation and Operating Instructions

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

3-Way Solenoid Valve - Direct Acting

Lifting / Lowering valve type HSV

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Mounting and Operating Instructions EB 5868/5869 EN

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Control and Terminal Box Type A21-**-*****

Operating Instructions

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Operating instructions Solenoid interlock EX-AZM About this document. Content

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Operating Instructions

On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E Pamphlet

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Limit switch attachments DAPZ

10 Load and Motor Switchgear

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

ILED Dorado. User Manual

Proportional Solenoids for Hydraulics G RC Y 037, 045, 063

Chapter 2: Directional Control Valves

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

EX T... AT. Sensors with switching function. Identification II 2 G Ex db eb mb IIC PTZ 16 ATEX 0024

Braking Devices BR 230/ Assembly- and Commissioning Instructions

ELECTROMAGNETIC DISC BRAKES H2SP SERIES WITH CONSTANT BRAKING TORQUE

Proportional Solenoid for Hydraulics ATEX + IECEX

SITRANS P measuring instruments for pressure

Operating Instructions

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

DEVICE STATE/BYPASSED FAILURE OVERLOAD

86740/ /2-way piston valves

Level limit switch Series RF 3000 Selection list

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

Safety switches for hinged doors

Technical Data Sheet

97100 NAMUR. Technical data

Explosion-Protected Pressure Switches

Operating and Installation Manual Shut-off damper Type AK-Ex with control components T0* and P50

A good connection. International approvals.

TIDALFLUX 2300 F Quick Start

Valve Technology DIN EN Butterfly Valves

BR 10a Control and Shut-off Butterfly valve

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

Installation and Operational Instructions for ROBA-stop -tacho brake Type 83_.41_._ and ROBA-stop -tacho peak load brake Type _.

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

User Manual Rittal PMC UPS 6kVA

Modern Explosion Protection

2/2 Solenoid Cartridge Valve, Size 6

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Safety Switches Series 8537

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

Analytical Diaphragm Pump Series MP MP06, MP12

MAGNETO-INDUCTIVE POSITION DETECTORS

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Pneumatic Axial Fan Type Tech. Doc. No. 802

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

Limit Switch Type 3776

Transcription:

Operation Instructions (translation) Explosion Protection Explosion protection is one option and is marked on the ex-type plate on the solenoid drive. The actuators and the associated solenoid controllers correspond to ignition protection class na category II3G and can be used in areas in which potentially explosive gas, vapour, mist or air mixtures are not expected to occur, and if so seldom or only for brief periods, i.e. explosion zone 2. The electrical and thermal parameters of the individual variants can be found on the type plate. The explosion protection refers to operation. In case of installation, maintenance or repair the respective ex-directives, especially EN 60079-14 (VDE 0165 T1) are to be observed. The electric installation is to be executed by an electrician under additional observance of the relevant national directives (in Germany VDE 0100), or respectively, the installation must be supervised by an electrician. Subsequent to installation the information of the device markings are to be compared with the planned for conditions of operation to guarantee an operation in accordance with the regulations. Principles As a standard combinations of valve drive are supplied in a completely installed and checked state. On exchanging or changing of solenoid drives it must be observed, that the combination with an UNI-valve has been released and the magnet is correctly (e.g. permitted starting torque) installed onto the valve. Solenoid drives are electronic components, which are not operable without the respective valve. Solenoid valves with an A in the type key consist of starting coil and a restraining coil. After switching on of the valve the valve control switches from the starting power to the lower holding power. In case of open-air installation always use solenoid drive in IP65 with rain protection hood. Obviously damaged drives must not be installed, or respectively, must be exchanged. If the drives are subject to external loads of special types, additional protective measures must be applied as necessary. Electrical Connection Connection lines for drives, which are marked with an x behind the type of protection, must be temperature resistant up to at least 100 C. When choosing the connecting line, conductors of adequate cross section must be selected as well as the correct type of cable gland (EN60079-14). The diameter of the cable gland can be obtained from the relevant data sheet.if fl exible connecting lines are used, insulated end sleeves for strands with plastic collar as per DIN 46228 part 4, must be used.. The connection thread of the cable gland amounts up to 30 Watt M16x1,5, from 40 Watt M20 x 1,5. The available distribution voltage must be available at the drive in an area of between 15% to +10%. As protection against short circuits a fuse (max. 3xIB as per DIN 41571 or IEC 127), which corresponds to the rated current of the drive must be superposed on the solenoid drive. The rated safety current of the fuse must be equal or higher than the stated rated voltage of the solenoid drive. The turn-off ability of the fuse link must be equal or larger than the maximum short circuit current at the installation site. To at least guarantee the protection type IP 54, the solenoid housing lid must be carefully re-installed. Variants which are supplied ex works including a connection cable, are ready for use, i.e. the connection room needs not be opened any more. The capacitors in the solenoid valve control TS800C must be discharged by an expert. 1 TM 3275

Operation 100% ED are permitted even in case of the most unfavourable ambient conditions permissible. DANGER! During continuous operation the solenoid drive may get hot. Don t touch, danger of injuries! During operation it must be guaranteed, that neither the maximum permitted ambient temperature or of the fl uid nor the load limit (excess voltage) will be exceeded. If necessary the solenoid drive is to be protected against overcharging. All solenoid drives are wired with a varistor. To avoid induced voltage, which may cause damage of the line, the user must provide protective measures in case of necessity which go beyond the installed varistor. CE-Identifi cation The Council of the European Community passed common directives for the free movement of goods within the European Community, which determine the minimum requirements for safety and health protection. The CE-identifi cation confi rms, that the products correspond to the EC directives, i.e. are in agreement with the relevant, especially harmonized standards. For explosion-proof solenoid drives the following directives are to be considered: 94/9/EG, 2006/95/EG und 2004/108/EG. Note concerning directive 94/9/EG (explosion protection directive ATEX 100): The solenoid drives fulfi l the relevant requirements of directive 94/9/EG; therefore they have the CE-identifi cation as per annex X of the directive. The declaration of conformity is included. Note concerning directive 2006/95/EG (Low-Voltage Directive): The drives were developed, designed and produced in accordance with the standard Electromagnetic Appliances DIN EDV 0580. Thus they will also fulfi l the requirements of the low voltage guidelines, which apply to rated voltages from 50 to 1000V AC and from 75 to 1500V DC. Note concerning directive 2004/108/EG (EMV-Directive): The solenoids fulfi l the requirements of the specifi cation of the product families EN 55014-1,-2 ; EN 61000-3-2, -3-3 concerning the industrial sector as well as the sectors of private housing, business and trading, as well as of small businesses. On using of AC- and DC-variants the user must provide a suitable mains fi lter (e.g. X-capacitor 47 nf) at the mains entrance to attenuate the physically caused line-related turn-off current of the solenoid. In the sense of the EMV-directives solenoid drives with driving elements for valves are not regarded as independently operable appliances and are only processed further by expert companies, or respectively installed into a machine. They must not be started up until it was determined that the machine, or respectively, the complete line, corresponds to the regulations of the EMV-directives. Dismounting of the solenoid drive Stop the solenoid drive and cut off voltage supply.. DANGER! During continuous operation the solenoid drive may get hot. Don t touch, danger of injuries! 2 TM 3275

Solenoid drive MG 0801, 3803 Unscrew and remove hexagonal nut (901). Completely remove solenoid drive ( 800) from the upper part of housing (106). Solenoid drive MG 004 008 Solenoid drive MG 010 020 900 105* 401* 501 105* 501 900 401* 700 IP54 IP65 701 1004 702 500 103 IP 54 IP 65 701 1004 702 500 103 402* 115.000.047..* /..** = Spare parts..** 402* 115.000.003 Unscrew hexagonal head screw (900) and remove it including insulating bush (401*). Remove cover of solenoid housing (105*) from solenoid housing (103). Loosen and remove connecting bolt (501). Solenoid drive volume control butterfl y valve Loosen protective cap (505) and remove including o-ring (403*). Remove cover of solenoid housing (105*) from solenoid housing (103). Unscrew and remove hexagonal nut (901). Item Description 103 Solenoid housing 106 Upper part of housing 500 Magnet plate 501 Connecting bolt 701 Cable gland 702 Solenoid 714 Mains outlet 800 Solenoid drive 900 Hexagonal head screw 901 Hexagonal nut 1004 Casting compound Spare parts Item Description 105*(**) Solenoid housing cover 401* Insulating covering 402*(**) Gasket 403** O-ring..* are supplied as an E-Kit (MG004 MG020) are supplied as an E-Kit (volume control fl ap) 3 TM 3275

Subsequently the solenoid housing (103) will be completely dismounted from the upper part (106) of the solenoid valve together with magnet plate (500) and coil (702). Remove magnet plate (500) and coil (702) from the solenoid housing (103). Assembly will be done in reverse order. NOTICE! Before assembly or if the sealing elements are damaged, with solenoid actuator MG004 MG020 (solenoid housing cover (105*), insulating housing (401*) and fl at gasket (402*)), or with solenoid actuator volume control butterfl y valve (solenoid housing cover (105**), O-ring (403**) and fl at gasket (402**)), replace if necessary. (also contained within E-kit) Screw torques of the connecting bolt (501) and the hexagonal head screw (900) Screw torque Thread size Item 501 + 900 4,6 Nm M6 11 Nm M8 22 Nm M10 62 Nm M14 Solenoid drives MG... / MG..Xn Type MG... P W Nominal current A 24 110 125 220 230 240 110 230 VAC VAC 3803 18 - - - - - - - 0,08 0801 16 1,5 - - - - - - - 004 10 0,4 0,09-0,05 0,04 0,04 0,09 0,04 005-3 15 0,6 0,1-0,07 0,07 0,06 0,1 0,07 008-2 30 1,3 0,3-0,1 0,1 0,1 0,3 0,1 010 40 1,7 0,4-0,2 0,2 0,2 0,4 0,2 012 50 2,1 0,5-0,2 0,2 0,2 0,5 0,22 014 70 2,9 0,6-0,3 0,3 0,3 0,6 0,3 016 90 3,8 0,8 0,7 0,4 0,4 0,4 0,8 0,4 018 125 5,2 1,1 1,0 0,6 0,5 0,5 1,1 0,5 019 160 6,7 1,5 1,3 0,7 0,7 0,7 1,5 0,7 020 175 12,5 1,6-0,8 0,8 0,7 1,6 1,3 4 TM 3275

Solenoid drive MG...A / MG..A..Xn with internal drive TS900, TS1500 Type P Nominal current A TS 900 TS 1500 MG..A.. W 24 110 220 230 240 110 230 VAC VAC 016-A 720/70 30/2,9 6,5/0,6 3,3/0,3 3,1/0,3 3,0/0,3 6,5/0,6 3,1/0,3 018-A1 900/70 38/2,9 8,2/0,6 4,1/0,3 3,9/0,3 3,8/0,3 8,2/0,6 3,9/0,3 018-A2 1200/70-11/0,6 5,5/0,3 5,2/0,3 5,0/0,3 11/0,6 5,2/0,3 019-A1 1200/120-11/1,1 5,5/0,6 5,2/0,5 5,0/0,5 11/1,1 5,2/0,5 019-A2 1500/90-14/0,8 6,8/0,4 6,5/0,4 6,3/0,4 14/0,8 6,5/0,4 019-A5.3 400/20 17/0,9 3,6/0,2 1,8/0,09 1,7/0,09 1,7/0,08 3,6/0,2 1,7/0,09 019-A5.4 400/50 17/2,1 3,6/0,5 1,8/0,23 1,7/0,2 1,7/0,2 3,6/0,5 1,7/0,22 Solenoid drive MG...A5 / MG..A5..Xn with internal drive TS200 Type MG... P W Nominal current A 24 230 VAC 010-A5 200/20 8,3/0,8 1,2/0,9 012-A5 200/20 8,3/0,8 1,2/0,9 014-A5 200/20 8,3/0,8 1,2/0,9 016-A5 200/20 8,3/0,8 1,2/0,9 018-A5 200/20 8,3/0,8 1,2/0,9 019-A5 200/20 8,3/0,8 1,2/0,9 Switching frequency: Circuits / hour Solenoid drive MG 1000 004-020 20 016A - 020A 600 010A5-019A5 20 016A5C6, 019A5C6 ; 016A5.2C6, 019A5.2C9 Solenoid valve control Solenoid valve control TS 200 TS 800 TS 900 / 1500 RKS 5-1500 / 5-4000 max. Switching Capacity Watt 200 800 900/1500 1500/4000 Switchover Sec. 1,5 40(*) 3 3 for opening delay Sec. - - 10 10 (*) Charging time 5 TM 3275

Solenoid drive MG...A with mounted control: RKS 5-4000 Solenoid drive MG...A With category II3G, only permitted outside the ex- zone (installation of RKS(*) separate from valve in switch cabinet) Type P Nominal current A MG..A.. W 24 230 VAC 019-A3 4000/100-17,4/0,4 019A-A3.1 3000/160-13/0,7 020-A1 2000/100-8,7/0,4 020-A2 3000/125-13/0,5 020-A3 4000/132-17,4/0,6 Solenoid drive MG...A with mounted control: RKS 5-1500 Solenoid drive MG...A...Xn With category II3G, only permitted outside the ex- zone (installation of RKS(*) separate from valve in switch cabinet) Type MG..A.. P W Nominal current A 24 125 018-A2 1200/70 50/2,9-019-A1 1200/120 50/5-019-A2 1500/90 63/3,8-019-A5 200/20-1,6/0,16 RKS 5-1500 / 5-4000 Depht 115 mm As per request of customer valve control RKS 5-1500 / 5-4000 for installation into switching cabinet Solenoid drive MG...A...C with mounted control: TS800 Solenoid drive MG...A...C...Xn With category II3G, only permitted outside the ex- zone (installation of RKS(*) separate from valve in switch cabinet) Type P I nom.. A Charging time MG..A..C W 24 sec. 16A5C6 48/20 2 40 19A5C6 48/20 2 40 16A5.2C6 72/50 3 40 19A5.2C9 72/50 3 50 RKS(*) Relay Combination Controller 6 TM 3275

Standard solenoid drive IP54 Standard solenoid actuator IP 65* C B C A B A * compound fi lled with casting resin. Solenoid actuator Harting connector HAN 7D / 8D optionally available E C B A 7 TM 3275

Solenoid actuator Xn version IP 54 and IP 65** In accordance with DIN EN 60079-0, as well as the inner earth connection, version type Xn solenoid actuators have an additional outer earth connection, with a conducting connection between them. The outer earth connection is suitable for connecting a maximum of two equipotential bonding conductors, each with a crosssection of up to 6mm². C B Minimum cross-sectional area of earthing conductors Cross-sectional area of the phase conductor of the installation, S mm² S 16 Minimum cross-sectional area of the associated protective conductor, S P mm² S 16 < S 35 16 S > 35 0,5 S A Protective conductor connection The solenoid actuator must always be integrated in the equipo- tential bonding. A connecting facility is available for this purpose in the vicinity of the magnetic coil connecting terminal. NOTICE! The solenoid drive must additionally be earthed via the external earthing connection on the housing. ** encapsulated with cast resin up to the terminal strip Dimension Drive Weight in kg A B ØC D E MG... IP 54 IP 65 004 100 60 80-152 1,6 1,7 005 100 60 80-152 1,6 1,7 008 120 73 102-163 3,2 3,5 010 (A) 159 88 127-176 6,0 7,0 012 (A) 159 97 127-176 6,6 7,2 014 (A) 201 120 153-189 10,5 11,7 016 (A) 201 134 153 152 189 11,7 12,5 018 (A) 223 152 191 171 208 19,0 22,2 019 (A) 223 152 191 171 208 21,3 24,5 020 (A) 256 182 230-227 36,3 40,0 8 TM 3275

Rainproof cover standard series MG Rainproof cover explosion protection series for MG Xn version E E F F Size ØE F MG..(A)..., MG..Xn.. Size ØE F MG..(A)..., MG..Xn.. 1 170 50 004, 005 3 260 64 014(A), 016(A) 2 220 56 008, 010(A), 012(A) 4 370 50 018(A), 019(A), 020(A) Connection plan with screwed cables as per DIN EN 50262 available as stan- dard & Xn version for explosion protection version Solenoid drive MG... 004 005-3 008-2 010 012 014 016 018 019 020 010-A5 012-A5 014-A5 016-A 016-A5 018-A1 design VAC design 24 110 125 220-240 24-110 240 01 01 01 01 02 02 04 018-A2 05 018-A5 04 019-A1 019-A2 05 04 05 04 04 04 019-A3 05 05 05 05 019-A5 019-A5.3 019-A5.4 020-A1 020-A2 020-A3 04 04 04 04 04 05 05 05 05 05 AP 01 AP 02 AP 04 AP 05 9 TM 3275

Connection plan with pin-and-socket connector as per DIN EN 175301-803 (not available in Xn version) Solenoid design VAC design drive MG... 24 110 125 220-240 24-110 240 3803 - - - - 06 06 0801 004 005-3 008-2 010 012 014 016 018 019 020 010-A5 012-A5 014-A5 016-A 016-A5 016A5C6 016A5.2C6 018-A1 03 018-A2 09(*) 018-A5 03 019-A1 019-A2 AP 08 08 08-08 08 06 06 AP 09 - - 03 03 09(*) 03 03 03 07 - - - - - 09(*) 03 09(*) 03 03 03 019-A3 - - 09(*) 09(*) 09(*) 019-A5 03 03 03 03 03 019A5C6 019A5.2C9 019-A5.3 019-A5.4 020-A1 020-A2 020-A3 07 - - - - - 03 03 09(*) 03 03 03 - - - 09(*) 09(*) 09(*) AP 03 AP 06 AP 07 AP 09* * Installation of switching cabine 10 TM 3275

Connection plan with pin-and-socket connector as per DIN EN 175301-801 / DIN 43652 (not available in Xn version) DIN EN 175301-801 Solenoid design VAC design drive MG... 24 110 125 220-240 24-110 240 004 005-3 008-2 010 012 014 016 018 019 020 010-A5 012-A5 014-A5 016-A 016-A5 016A5C6 016A5.2C6 08 08 08 08 010 010 03 03 09(*) 03 03 03 07 - - - - - 018-A1 03 018-A2 09(*) 018-A5 03 03 03 03 019-A1 09(*) 03 09(*) 019-A2 019-A3 - - 09(*) - 019-A5 03 03 03 03 019A5C6 019A5.2C9 07 - - - - - 019-A5.3 019-A5.4 03 03 09(*) 03 03 03 020-A1 020-A2 020-A3 - - - 09(*) - 09(*) AP 03 AP 07 AP 09 AP 09* DIN 43652 AP 08 AP 10 * Installation of switching cabine 11 TM 3275

Declaration of Conformity: Solenoid actuator in standard version Declaration of Conformity: Solenoid actuator in Xn version 12 TM 3275