Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

Similar documents
Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model VCD-20 3V CONTROL DAMPER

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

VCD-23. Low Leakage CONTROL DAMPER

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

VCD-23. Flange Options. Size Limitations

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

ID-141x 12-Gauge Hat Channel Industrial Damper

AMD-33 Air Measuring Station with VCD-33 Control Damper

VCD-23 Low Leakage CONTROL DAMPER

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

HCD-230 Industrial Control Damper

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

PC-125x Counter-Balanced Backdraft Damper

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax)

VOLUME CONTROL DAMPERS

BD-1600 Balancing/Zone Control Damper

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

ARROW INDUSTRIAL PRODUCTS

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

When Time is Everything... We Manufacture in Days - Not Weeks!

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

ARROW UNITED INDUSTRIES

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS

HVAC Control & Balancing Dampers

SD-1250 and SD-1600 Series Smoke Dampers

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

GRAVITY VENTILATORS SIZING

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

L O U V E R S & D A M P E R S

Model FSD-331 Combination Fire Smoke Dampers

2520- EC Motor Speed Controller

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

SECTION AXIAL HVAC FANS

WALL MOUNTING KIT ASSEMBLY INSTRUCTIONS MODELS: TXBW & TXDW

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

AIR CONDITIONING PRODUCTS COMPANY

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG CATALOG 4720 MAY 2014

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

RD-2000 Round Control Dampers

GRAVITY VENTILATORS SIZING

FILTERED SUPPLY CENTRIFUGAL Belt Drive

INSULATED CANTED ROOF CURB NON-PROPELLER PRODUCTS

INSULATED CANTED ROOF CURB NON-PROPELLER PRODUCTS

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Supplemental Information Control Damper Panel & Jackshaft Arrangements Volume Control Damper Models: AC1, AC2, 515, 516, 525, 526, AC18, AC19

Automatic Roof Door Vents


Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

SECTION DUCTWORK ACCESSORIES

HVAC Control & Balancing Dampers

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Industry best 5 year fan housing warranty, 1 year motor warranty

A Complete Line of Quality Products for Marine Applications

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

MOTORIZED VOLUME DAMPER

Motorized Fire Dampers

Thermal Isolation. Break

Air Measuring Products AMD AMS IAQ

CFSD Series. Product Description

WALL MOUNTING KIT ASSEMBLY INSTRUCTIONS MODELS: TXBW & TXDW

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

Axial Propeller Panel Fans, PAF-Series

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

VD-1600 Series Volume Control Dampers

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

Introduction to Johnson Controls Dampers

SECTION CONTROL DAMPERS

Transcription:

Submittal Data Model PELV-100 Penthouse Elevator Vented Hood Application and Design The PELV-100 Penthouse Elevator Vented Hood is a gravity ventilator penthouse with an 18" x 18" gasketed access door and a low leakage opposed blade control damper with either a 24VAC or 120 volt actuator. The unit is provided with weather hood(s) to help minimize wind driven rain and snow infiltration. The unit is shop assembled and shipped loose from the curb. Standard Construction Finish Roof Mill 0.090 formed aluminum with 0.5 in. insulation Hood 0.063 aluminum, non-insulated with ¾" ¾" Stamped Grille in Opening Curb Damper 18 ga. galvanized, 2 in. mounting flange, welded construction, 1" thick insulation Model...Buckley GPI Size... See Chart Model...Greenheck VCD-23 Size and Free Area... See Chart Actuator... 120V or 24VAC, Mounted Internally with End Switch, Power Closed, Fail Open Glass (Optional) 0.125 in. clear tempered glass Models Available Model Dimensional Data Curb Optional Glass Damper Hood A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty PELV-100-32-1 32 24¾ 36 31½ 31½ 18 14 1 26 18 PELV-100-32-2 32 24¾ 36 31½ 31½ 18 14 2 26 18 PELV-100-38-1 38 24¾ 36 37½ 37½ 24 14 1 32 18 PELV-100-38-2 38 24¾ 36 37½ 37½ 24 14 2 32 18 PELV-100-44-1 44 24¾ 36 43½ 43½ 30 14 1 38 18 PELV-100-44-2 44 24¾ 36 43½ 43½ 30 14 2 38 18 Unless otherwise noted, all dimensions are in inches. *The Total Free Area is based on the assumption that 80% of the screen is open. Buckley Associates, Inc. Manufactured by Buckley Associates, Inc, Hanover, Massachusetts Sheet Metal Union Local 17. TFB24-S TFB120-S TFB24-S TFB120-S TFB24-S TFB120-S TFB24-S TFB120-S FSNF24-S FSNF120-S FSNF24-S FSNF120-S Opening Size PELV-100 April 2016 Total Free Area* 1 30 18 3.0 sq. ft. 2 30 18 6.0 sq. ft. 1 36 18 3.6 sq. ft. 2 36 18 7.2 sq. ft. 1 42 18 4.2 sq. ft. 2 42 18 8.4 sq. ft. Water Infiltration Disclosure Louvered penthouses provide a level of defense against weather infiltration, however; louvered penthouses cannot be considered weather proof. Buckley recommends provisions to manage weather infiltration be present beyond the louvered penthouse so as to mitigate weather passage and prevent weather related damage to building conditions or equipment. Design of or materials as required to manager weather infiltration are not provided by Buckley. Buckley also recommends sound product application/engineering practice(s) be employed when applying louvered penthouses. Such practice(s) may include, but are not limited to, conservative throat and louver face area velocities. Buckley shall not be held liable for water related damage to building conditions or equipment.

Printed Date: 6/26/2013 Job: STOCK VCD Mark: D-1 H Low Leakage Control Damper Application & Design The model VCD-23 is a low leakage control damper for application as an automatic control or manual balancing damper. This model is intended for applications in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators are available. Non-jackshafted dampers will be supplied with a blade drive lever for internal actuator mounting. When external actuator mounting is specified in which case an extension pin with clip kit will be provided. Note: The extension pin with clip kit includes the extension pin and clip. W 5 1.25 Max. RATINGS Pressure: 5 in. wg Velocity: 3,000 ft/min Leakage: Class 1A @ 1 in. wg, Class 1 @ 4 in. wg Temperature: 200.0 F-250.0 F. Consult factory for higher temperatures. Installation instructions available at www.greenheck.com. Notes: All dimensions shown are in units of inches. W & H furnished approximately 0.25 in. undersized and only refer to damper dimensions (sleeve thickness is not included). Electrical accessory wiring terminates at the accessory. Field wiring is required to individual components. CONSTRUCTION FEATURES Blade Action: Opposed Frame Type: Channel Material: Galvanized Axle Material: Steel Axle Bearings: Synthetic Linkage Material: Steel Blade Seal: TPE Jamb Seal Mat.: 304 SS Sizing: Nominal Frame Thickness (ga): 16 Actuator Type: 120 VAC Actuator Mount: Internal Actuator Location: Left Side Fail Position: Open Cycle: 60 Cycle Jackshafting: No Preference Auxiliary Switches: Yes Temp. Rating (F): 180 ID # Tag Qty W (in.) H (in.) Drive Arr. Actuator Act. Qty. 1-1 1 38.000 18.000 Drive-CC-11-1FIL-0 FSNF120-S 1 1-2 1 26.000 18.000 Drive-CC-11-1FIL-0 TFB120-S 1 1-3 1 32.000 18.000 Drive-CC-11-1FIL-0 TFB120-S 1 CAPS 4.11.1420 R:\Job Files\Greenheck\Salesperson\CCameron\BUCKLEY\STOCK VCD.gfcj Page 1 of 2

Printed Date: 6/26/2013 Job: STOCK VCD Damper Drive Arrangements Job Summary -Start- Drive Arrangement: Drive-CC-11-1FIL-0 Damper Drive Arrangements Job Summary -End- CAPS 4.11.1420 R:\Job Files\Greenheck\Salesperson\CCameron\BUCKLEY\STOCK VCD.gfcj Page 2 of 2