Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Similar documents
Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Operating Instructions for Plastic Flow Meter. Model: KSK

Operating Instructions for Paddle Bellows Flow Monitor. Model: FPS-P...

Operating Instructions for Viscosity Compensated Flow Meter / Monitor. Model: VKM

Operating Instructions for Flow Indicator. Model: DAA

Operating Instruction for Flowmonitor. Model: DF-WM

Operating Instructions for Paddle Flowswitch Model: PPS-...

Operating Instructions for Paddle Flow Monitor. Model: PSR-..., PSE-...

Operating Instructions for Magnetic Filter. Model: MFR-00

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

Operating Instructions for Torsion Paddle Flow Meter / Monitor. Model: DPT-...

Operating Instruction for Electronic Pressure Switch. Model: PDD

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA

Instruction Manual. Ex-Time 40 / 50

Operating Instructions for Oval Wheel Flowmeter. Model: DOE

High Precision Turbine Wheel Flow Meter for Liquids

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AY1X/S1139

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

Solenoid coils VACF Type codes

Flap-Type Flow Meter Prall

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x)

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Control and Terminal Box Type A21-**-*****

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Compact pressure switch Model PCS

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Series TNS/TNF Thermometers Installation/Operation Instructions

Solenoid Valves Type 3963

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Technical Data. Dimensions

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Operating Instructions

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Limit switch attachments DAPZ

FLOW. control. switch measure. Flow Switches

Explosion-protected surface-mounting Thermostat ATH-Ex Series

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Level Measurement based on Archimedes Principle. Device Description

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Operating Instructions for Oval Wheel Flowmeter High pressure. Model: DON-H...R0/H0/Z1/Z2/Z3

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PUA574 / PUA579(x)

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Direct-acting 3/2 way plunger valve

Solenoid Operator 0516 / 1216

Operating Instructions

General Specifications

Circulation pumps BFP-ATEX-T3/T4

SITRANS P measuring instruments for pressure

Condensate Drain Valve AK 45. Original Installation Instructions English

Solenoid Valve Island Type 3965

Sensor boxes SRBE Key features and product range overview

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

SERIES 54 Inductive Proximity Sensor

Compact temperature switch Model TCS

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

Accessories Cable glands

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

HST -LS Interlocking device (Translation of Original Manual)

97105 Inline. Ordering information. Technical data. Accessories See page 5

Electronic Limit Switch Type

PHOENIX CONTACT - 01/2008

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Compact differential pressure switch Models DC, DCC

Explosion Proof Equipment General Overview*

Type Electronic Limit Switch

TER. Thermostats for Industrial Applications. Switching range: C to C. Housing material: aluminium. Capillary tube: copper

Ex m Solenoid Operator Type 0519

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Design and application

EX T... AT. Sensors with switching function. Identification II 2 G Ex db eb mb IIC PTZ 16 ATEX 0024

Electro-pneumatic control valves

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

PSR/PSE Paddle Flow Monitor for Liquids Switching ranges: L/min water p max : 250 bar, t max

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

ProFlow TO BE REALLY SURE. Vane Meters. Experience in flow measurement. Introduction

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01.

For mounting on subbase or footprint in accordance with CNOMO recommendation E 06620N Part numbers (and voltages) Voltage max. power consumption U nom

Intrinsically Safe Miniature Solenoid Valves

Operating Instructions (Translation)

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Differential pressure gauges with Bourdon tube

Mini temperature switch Stainless steel switch enclosure Model TXS

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

OPTISWITCH 6500 C Technical Datasheet

ExBin-P Pressure switches 5 Pa Pa

MAGNETIC FLOAT SWITCH

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B

Cable resistance thermometer Model TR40

Block mounting filter, for sandwich plate mounting

Transcription:

Operating Instructions for Float Flow Meter / Monitor Model: SWK

1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 4 5. Operating Principle... 4 6. Use in Hazardous Areas... 5 6.1 General... 5 6.2 Electrical Contact... 5 6.3 Equipotential Bonding... 5 7. Mechanical Connection... 6 8. Electrical Connection... 6 9. Operation / Configuration / Adjustments... 7 9.1 Adjustment of Limit-Value (SWK-1...)... 7 9.2 Adjustment of Limit-Value (SWK-2...)... 7 10. Maintenance... 8 11. Technical Information... 8 12. Order Codes... 9 13. Dimensions... 10 14. Declaration of Conformance... 11 Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: +49(0)6192-2990 Fax: +49(0)6192-23398 E-Mail: info.de@kobold.com Internet: www.kobold.com page 2 SWK K02/0413

2. Note Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health & Safety and prevention of accidents. When used in machines, the measuring unit should be used only when the machines fulfil the EWG-machine guidelines. as per PED 97/23/EG In acc. with Article 3 Paragraph (3), "Sound Engineering Practice", of the PED 97/23/EC no CE mark. Diagram 8, Pipe, Group 1 dangerous fluids 3. Instrument Inspection Instruments are inspected before shipping and sent out in perfect condition. Should damage to a device be visible, we recommend a thorough inspection of the delivery packaging. In case of damage, please inform your parcel service / forwarding agent immediately, since they are responsible for damages during transit. Scope of delivery: The standard delivery includes: Float Flow Meter / Monitor Model: SWK Operating Instructions SWK K02/0413 page 3

4. Regulation Use These units, type SWK, are used for the purpose of measuring and monitoring liquid flow. Only clean, low-viscous and homogeneous liquids may be measured which do not chemically attack the materials used in the construction of these units. An attempt to measure high-viscous liquids may lead to considerable measurement errors. Large dirt-particles can cause the blockage of float and subsequently turn on error indications. Also, ferrite particles, which deposit on float (with embedded magnets), can generate the same effect (we recommend a magnet-filter). These units are configured in the following manner: Housing made of Brass, St. Steel or PVC Attached reed contact N/O with 1m PVC cable (Brass version) Attached reed contact N/O with 2m PVC cable (PVC/VA version) Attached and aligned pointer display (option) 5. Operating Principle KOBOLD Flow Meter/Monitor of type SWK operates according to the well known float principle, however without making use of the generally employed extended measuring tube. Inside a cylindrical flow-tube a float with aperture moves in the direction of the flow against the recoiling force of a spring. Within the float, a pair of magnets is located which trigger a potential-free protective-gas reed contact and drives a pointer display. The reed contact is mounted on the exterior of the flow-housing. The springs arrangement allows the unit to be operated without consideration to mounting position and keeps the installation dimensions to a minimum. Flow monitors of type SWK generally find application where small volume flow needs to be measured in a fail-safe manner. page 4 SWK K02/0413

6. Use in Hazardous Areas 6.1 General The Flow Meter/ Monitor does not have a potential igniting source of its own as a mechanical operating resource; it does not get any identification according to the guideline 94/9/EC ("ATEX 100a ). The mounted contact can be used in intrinsically safe circuits as a simple apparatus according to EN 60079-14. The following limit values for the switching contact should not be exceeded: U = 30 VDC, I = 100 ma, P = 1,2 W. The measurement units can be used as follows: a) In the Zone 2 (Gas-Ex, Cat. 3G) into explosion group of IIA, IIB and IIC b) In the Zone 22 (Dust-Ex, Category 3D) at non-conductive dusts with a minimum igniting energy of > 3 mj c) In the Zone 1 (Gas-Ex, Cat. 2G) into explosion group of IIA, IIB and IIC d) In the Zone 21 (Dust-Ex, Category 2D) at non-conductive dusts with a minimum igniting energy of > 3 mj 6.2 Electrical Contact In the Ex-area, the Flow Meter/ Monitor can be used according to Category 2G and 2D for group II; in Zone 1 and 21 in connection with a switching amplifier for protection type Ex II (2)GD [EEx ia] IIC (intrinsically safe). The electrical connection is explained in section 8 Electrical Connection. 6.3 Equipotential Bonding The Flow Meter/ Monitor will allow equipotential bonding of the equipment. This will occur only when the connection pipes are made of metal. SWK K02/0413 page 5

7. Mechanical Connection Before installation: Make sure that the permitted maximum operating pressure and the operating temperature of the device are not exceeded. Make sure that the electrical supply for the devices corresponds with the operational data of the device. Make sure that no remains of packing material exist within the device. The devices should not be installed within an inductive field. If possible, it should be checked, after the mechanical installation whether the connection joints/ piping is properly sealed. Attention! A displacement of switching range occurs if the flow takes place from top to bottom. 8. Electrical Connection Attention! Make sure that the voltage values of your system correspond with the voltage values of the measuring unit, mentioned on type-label. Make sure that the supply wires are de-energized. The connection of the bistable reed contact succeeds is accomplished through the cable on the contact housing. The potential-free contact closes on rising level above the adjusted flow value. page 6 SWK K02/0413

9. Operation / Configuration / Adjustments The commissioning of these units is prohibited in machines (as long as the guidelines 89/392/EWG remain enforced), which do not comply with these guidelines. The unit is supplied in 'ready for operation' condition. The switching point is adjusted on the lowest scale value. 9.1 Adjustment of Limit-Value (SWK-1...) Loosen the knurled nut on the reed contact. Adjust the marking on the contact for the desired value on the scale. In once positioned the knurled nut should be tightly screwed. 9.2 Adjustment of Limit-Value (SWK-2...) Loosen the knurled nut on the reed contact. Connect a suitable continuity-tester on cable ends. Case 1: On an installed unit Open the supply line, and let the flow-medium enter slowly, till the pointer display shows the desired flow value- at which the rising flow should operate the switch (the value for the decreasing flow lies below due to the hysteresis). Case 2: On an uninstalled unit the adjustment may be performed by lifting the float with a suitable tool. Switch-housing is repositioned from top to bottom, till the reed contact just closes (electrical continuity). In this position, secure the contact by tightening the knurled nut. The unit is now adjusted and ready for operation. On correct adjustment, the limit-value contact performs bistable action. That means, even after on crossing above the adjusted limit-values, the contact remains closed. Hysteresis Hysteresis is an indication of difference between switch-on (rising float) and switch-off (falling float) points of a contact. The average hysteresis corresponds to a float-centre movement of about 3 mm. SWK K02/0413 page 7

10. Maintenance As long as the medium to be measured is not contaminated, the device SWK is almost maintenance-free. With lime or such depositions within inner sections the device should be cleaned regularly. Attention! Before the commencement of maintenance work, make sure that the supply wires are de-energized. 11. Technical Information Housing/Float: SWK-x1..: brass nickel plated, Ms 58 SWK-x2..: stainless steel, 1.4301 SWK-13..: PVC Connections: G 1/2 female Float: SWK-x1..: brass, Ms 58 SWK-x2..: stainless steel, 1.4301 SWK-13..: PVC Magnets: ceramic Compression spring: stainless steel 1.4310 Gaskets: none Butt rings: SWK-x1...: brass, Ms 58 SWK-x2...: stainless steel, 1.4301 SWK-x13...: PVC Max. temperature: SWK-x1.., SWK-x2: 100 C SWK-13..: 60 C Max. pressure: SWK-x1.., SWK-x2: 250 bar SWK-13..: 6 bar Loss of pressure: 200 mbar at ME Installation position: Switch contact: any position bistable reed contact N/O contact or changeover contact with increasing flow rate Breaking capacity N/O contact: max. 230 V AC / DC, max. 3 A max. 60 W/VA Changeover contact: (SWK-xxxxU) max. 100 V AC/DC, max. 0.5 A, max. 5W/VA Electr. connection: 1 m PVC cable Switching hysteresis: 3 mm on scale (mean value) Repeatability: 2.5 % (contact) ± 4 % f. s. (indicator) Protection: IP 68 contact; IP 54 indicator Ex range: ATEX Zone 1 as simple apparatus page 8 SWK K02/0413

Average electrical switch contact life (MTTF): at max. electrical load: at half load (<10%max. load): at low load (<10V/<1mA): 10 5 switching operations 5*10 7 switching operations 10 8 switching operations 12. Order Codes Example: SWK-1101 Switching range L/min. water Connection female Flow monitors Flow meters and monitors Switch contact Material Material Material Material Material stainless stainless brass PVC brass steel steel 0.05-0.1 G 1/2 SWK 1101 SWK 1201 - SWK 2101 SWK 2201 0.1-0.2 G 1/2 SWK 1102 SWK 1202 - SWK 2102 SWK 2202 0.2-0.8 G 1/2 SWK 1108 SWK 1208 SWK 1308 SWK 2108 SWK 2208 0.5-1.8 G 1/2 SWK 1118 SWK 1218 SWK 1318 SWK 2118 SWK 2218 1.7-4.0 G 1/2 SWK 1140 SWK 1240 SWK 1340 SWK 2140 SWK 2240 4.0-9.0 G 1/2 SWK 1190 SWK 1290 SWK 1390 SWK 2190 SWK 2290 8-16 G 1/2 SWK 1116 SWK 1216 SWK 1316 SWK 2116 SWK 2216 13-24 G 1/2 SWK 1124 SWK 1224 SWK 1324 SWK 2124 SWK 2224 without = N/O contact u = changeover contact SWK K02/0413 page 9

13. Dimensions page 10 SWK K02/0413

14. Declaration of Conformance We, KOBOLD Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product: Float Flow Meter / Monitor Model: SWK... to which this declaration relates is in conformity with the standards noted below: DIN EN 61010-1 1994-03 Safety requirements for electrical equipment for measurement, control and laboratory use IEC529, DIN VDE 0470-1 1992-11 Protection through housing (IP-Code) Also, the following EWG guidelines are satisfied: 2006/95/EC Low Voltage Directive Hofheim, 16. Jan. 2007 H. Peters M. Wenzel General Manager Proxy Holder SWK K02/0413 page 11