Operating Instructions

Similar documents
Operating Instructions

Minimum quantity lubrication system MVE for external lubrication. Operation manual

Minimum quantity lubrication system MDE for external lubrication. Operation manual

Four Post Surface Lift

O P E R A T I N G M A N U A L

STARPOINT. Safety instructions. Starpoint VRS (-F) Fax: Phone:

B38 01/12. Installation and Operating Instructions Combi Gauges for Rail Cars Models Rg Fz, RChg Fz, DRg Fz, DRChg Fz. Contents

Operating and maintenance instructions

> VIP-Balancer < VIP-Balancer. VIP-Balancer

>IVH< >VVH< Shortening hook

Load Ring for bolting >VLBG<

RFID114. For use in combination with charge controllers used in electric vehicle charging stations, wall boxes or street light charging points.

Load Ring for bolting >VLBG-PLUS<

Load Ring for bolting >VLBG<

Operating manual FP-2. Index

Crane fork KGM/KGA and KGQ/KGL

Betriebsanleitung Operating Instructions. Diaphragm Pump

Instruction Manual for Microlitre Centrifuge Z 160 M

RSe Series. Operating Instructions. Safety Exhaust (Dump) and Safe Cylinder Return Control Reliable Double Valves. RC-RSe

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Universal spotlight LED

A408 GB. Pneumatic oil and diesel pumps 1:1

Gas and Diesel Sweep Star 60 Models C and C

Clamping and drive module

RESOL SBS 1000 * * Connection Operation

CORDLESS FLARING TOOL

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Instruction Manual for Ceramics up to 1320 C

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Powerflare Caution Light

RFID110-L1. For use in combination with charge controllers used in electric vehicle charging stations, wall boxes and street light charging points

Sugar beet covering eqipment

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Operating Instructions for Roll-Up Door Operators / MDF

Hydraulic Power Console HE V

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2.

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Automatic concealed bollards 275 H600 and 275 H800 with pit

HST -LS Interlocking device (Translation of Original Manual)

TM 60 TS 75 TS 100 Please read this user guide before using your operator. Please read carefully the security advises on the following pages!

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

OPERATING AND MAINTENANCE INSTRUCTIONS HYDRAULIC ELECTRICAL PUMPS HAM (Manual control) HAE (Electrical control)

Pneumatic, hydraulic Universal Riveting Tool PNP 90 UN 2.0. Instruction manual

Dumper 1001, 1501, 2001 OPERATOR S MANUAL

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Declaration of Conformity as per Directive 97/23/EC

20 TONNE HYDRAULIC PRESS MODEL NO: CSA20FBT

TPAK Series COOLANT PUMP

Pneumatic Axial Fan Type Tech. Doc. No. 802

Operating instructions

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Dumper OPERATOR S MANUAL

Vane pump, direct operated

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Betriebsanleitung Operating Instructions. Rotary Vane Pump

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

Hand winch with worm gear Type WH 7 S in accordance with DIN EN 13157

Suction unit SG-10 USER MANUAL. SG-10 standard version (REF ) SG-10 activated carbon version (REF )

MANUAL MACHINE BODY WITH INTERCHANGEABLE HEADS MU22N USE AND MAINTENANCE INSTRUCTIONS

SP6119 / SP6132 OPERATION MANUAL SPARE PARTS LIST

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Starting up hydraulic systems

Installation and Operating Instructions Magnetic Vibrator MR 1

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Assembly instructions

50 TONNE HYDRAULIC PRESS MODEL NO: CSA50FP

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

2 Ton - 50 Ton Bottle Jack

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Adjustable Speaker Mount GRAVIS 8

Adjustable Speaker Mount GRAVIS 12

Pneumatic grease pump 50:1 and grease supply system

TABLE OF CONTENTS. 1. Before You Begin 3 Disclaimer 3 What Is Included 3 Optional Accessories 3 Unpacking Instructions 3 Claims 3 Contact Us 3

HYDAC Fluidtechnik: Industrial Valves FLOW CNTROL VALVE COMPENSATED PRESSURE VP-SR X.XXX.0/01.09 E / D E /08.

Multi place suction unit SG-20

Type 6213 EV, 6281 EV

Hydraulic Impact Wrench Type

Spare Parts List Return line filter RF

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Translation. Operating Instruction Electromechanical linear drive..com

Operating Instructions LEO 23 GT

BR 31a Rack-and-pinion Actuator,

Proportional Pressure Reducing Valve PDM08130

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Installation Instructions

Oil-free piston compressors KK and piston vacuum pumps KV

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

Instruction manual and installation guide Traction sheave brake TSB TSB

CENTAFLEX-K Assembly and operating instructions 014K S... M EN Rev. 1

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Transcription:

Beuler Höhe 11, D-45525 Hattingen Tel. +49(0)2324/55515 info@stephandahlmann.de www.stephandahlmann.com Operating Instructions Contents Page 1. Designation and Illustration of the Machine 1 2. EC Declaration of Conformity 2 3. General Description of the Machine 3 4. Specified Conditions of Use 4 5. Residual Risks 4 6. Notes on Transport 4 7. Use and Conditions for Storage 4 8. Before Initial Operation 5 9. Operation 6 9.1 Operating the Machine 6 9.2 Pressure and / or Torque Adjustment 6 9.3 Tightening or Loosening Threaded Connections 6 10. Servicing and Fault Clearance 7 11. Shutdown 7 12. Technical Data 8 13. Electrical Diagram 9 14. Hydraulic Diagram 10 1. Designation and Illustration of the Machine Hydraulic device FE055-3-230V 1

2. EC Declaration of Conformity EG-Konformitätserklärung nach Maschinenrichtlinie 2006/42/EG Anhang II 1.A Der Hersteller Stephan Dahlmann Mechanik und Antriebstechnik GmbH Beuler Höhe 11, 45525 Hattingen erklärt hiermit, dass folgendes Produkt Produktbezeichnung: Serien-/Typenbezeichnung: Seriennummer: Hydraulikaggregat FE055-3-230V 721xxxx allen einschlägigen Bestimmungen der oben genannten Richtlinie sowie den weiteren angewandten Richtlinien (nachfolgend) - einschließlich deren zum Zeitpunkt der Erklärung geltenden Änderungen - entspricht. Folgende weitere EU-Richtlinien wurden angewandt: EMV-Richtlinie 2004/108/EG Folgende harmonisierte Normen wurden angewandt: DIN EN ISO 12100:2011-3 DIN EN ISO 4413:2011-04 Sicherheit von Maschinen Fluidtechnik - Allgemeine Regeln und sicherheitstechnische Anforderungen an Hydraulikanlagen und deren Bauteile Name und Anschrift der Person, die bevollmächtigt ist, die technischen Unterlagen zusammenzustellen: Dipl.-Ing. Stephan Dahlmann Beuler Höhe 11; 45525 Hattingen Ort: Hattingen Datum: 14.12.2011 (Unterschrift) Dipl.-Ing. Stephan Dahlmann, Geschäftsführer 2

3. General Description of the Machine Fig. 1 Components of the Machine: 1 Remote control 2 Remote control cable 3 Hydraulic fluid filler cap 4 Pressure adjustment valve 5 Manometer 6 Fluid level sight glass 7 Hose coupling connection "A" 8 Hose coupling connection "B" 9 Mains cable with mains plug 10 Manual actuation for solenoid valve 11 Fluid drain plug 3

4. Specified Conditions of Use This device is exclusively intended for use as a drive mechanism for hydraulic torque tools in line with the description and safety instructions given in these Operating Instructions. Any other use is considered to be improper! In particular the use of the machine as a drive for all other hydraulic devices such as presses, hoisting cylinders, hydraulic shears, spreaders, etc. is improper use! Improper use of the device or modifications to the device undertaken by the end-user exclude any liability on the part of the manufacturer and invalidate the Declaration of Conformity! In this case the user is liable for damages resulting from the use of the device. 5. Residual risks Danger due to hot surfaces: The surface of the oil cooler (if fitted) becomes hot; keep a safe distance; the warning symbol is attached to the cooler Danger due to noise: maximum noise level 82 db(a); the end-user must make personal protective equipment (ear-protectors) available. 6. Notes on Transport Delivery ex-works Hattingen: Packed in corrugated cardboard, on a pallet secured with strapping. Other types of packaging only after consultation with the manufacturer. Transport of the machine ready for operation: a. by hand: up to 30 kg with 1 person above 30 kg with two persons b. with industrial trucks: use suitable hoisting equipment c. suspended: use suitable slings (no chains, no metal ropes) 7. Use and Conditions for Storage Ambient temperature: -10 to +40 C for use and storage Protect from rain during use and storage. Modification of the conditions of use only after consultation with the manufacturer. Power supply connections: (delivery with earthed pin plug). In the event of modification to the mains connection, protection against shock must be guaranteed by installing a protective earth system. 4

8. Before Initial Operation Carry out a visual inspection before each start-up. Check remote control (1), mains plug (9) and all cables for damage. Check hose couplings, hoses 1) and hydraulic torque tools 1) for damage. 1) not included in delivery Hose couplings, hoses and hydraulic torque tools must be designed for an operating pressure of 700 bar. Hose couplings, hoses and hydraulic torque tools with lower operating pressures are not permitted to be connected to the hydraulic device! Check the entire machine, fluid reservoir, motor, manometer and air line lubricator for damage such as ruptures or leaks. Have damaged parts replaced by qualified technicians before operation. Check hose couplings (7, 8) for dirt. Clean soiled hose couplings before operation. Check the fluid level; the level must be up to the middle of the oil sight glass (6). If need be, top up hydraulic fluid. Set up the hydraulic device on a level, horizontal surface so that it is prevented from falling over or falling down. Connect the hydraulic device by means of the threaded couplings with the hoses and with the hydraulic torque tool: (as per Fig. 2) Power supply connections: (delivery with earthed pin plug). In the event of modification to the mains connection, protection against shock must be guaranteed by installing a protective earth system. Fig. 2 The hydraulic device must not be operated without the hoses and the hydraulic torque tool connected up! Connect the hydraulic device to the electricity supply. 5

9. Operation 9.1 Operating the Machine Switch on the motor by actuating the white push-button on the remote control (1). White push-button actuated: forward stroke of the tool piston White push-button not actuated: return stroke of the tool piston Switch off the motor by actuating the black push-button on the remote control (1) Relieve pressure of the device by manually actuating the solenoid valve (10) 9.2 Pressure and / or Torque Adjustment The torque of hydraulic torque wrenches is proportional to the pressure. This is why before tightening or loosening bolted connections the maximum pressure of the machine and thus the maximum torque of the torque tool must be adjusted: Do not place the hydraulic tool on either bolts or nuts. Switch on the motor by pushing the white push-button on the remote control (1) and keep the white push-button pressed down the tool piston extends. After reaching the end position of the tool piston, the maximum pressure of the system can be increased by turning the adjustment knob (4.1) on the pressure adjustment valve (4) clockwise until the required pressure is reached. The current system pressure is displayed on the manometer (5). By releasing the white push-button, the tool piston retracts. Fig.3 Checking the setting: after reaching the end position a second time, press the white push-button again in order to extend the tool piston completely and to keep it until the maximum pressure is reached. To reduce the maximum pressure, turn the adjustment knob (4.1) on the pressure adjustment valve (4) anti-clockwise. When the required pressure is reached, the setting is secured by tightening the wing nut (4.2) on the pressure adjustment valve (4). 9.3 Tightening or loosening threaded connections Tightening or loosening threaded connections is done according to the instructions of the torque tool manufacturer. 6

10. Servicing and Fault Clearance As a matter of principle, electrical work may only be carried out by qualified electricians. Use only original spare parts as per the spare parts list. Hydraulic fluid change and filter change (if fitted) at least once every year or at the latest after every 300 operation hours; if necessary earlier, if the hydraulic device is used in a dusty environment. Recommended hydraulic fluids: HLP32 or HLP46 Hydraulic fluid quantity : see Technical Data (Section 12) Fluid filter as per spare parts list Malfunction Possible cause Remedy Motor does not start Mains cable not connected connect Mains cable Incorrect mains voltage Mains cable faulty Check mains voltage; if necessary connect to suitable electricity supply Have it replaced by qualified electrician Remote control cable faulty Remote control faulty No (or insufficient) pressure build-up even though motor is running Tool does not move even though pressure builds up correctly Tool works the wrong way round Machine faulty Too little or no hydraulic fluid Maximum pressure not set or set too low Machine faulty One or several hose couplings not tightly connected Tool connected incorrectly Have it serviced by authorised workshop Top up hydraulic fluid Adjust pressure as per Section 9.2 Have it serviced by authorised workshop Connect up machine, hoses and tool as per Section 8, Fig. 2 Connect up machine, hoses and tool as per Section 8, Fig. 2 11. Shutdown Switch off motor by actuating the black push-button on the remote control (1). Release the pressure in the system by pressing and holding down the black push-button and at the same time pressing the white push-button once. Disconnect the hydraulic device from the compressed air supply. Turn the adjustment knob on the pressure adjustment valve (4) all the way anti-clockwise and thus set the maximum pressure to 0 bar. Disconnect the hydraulic device from the hoses. 7

12. Technical Data Type FE055-3-230V Technical Data Voltage Nominal power output Pump capacity: Low pressure < 75 bar Medium pressure 75-220 bar High pressure up to 700bar Weight without/with hydraulic fluid Fluid capacity Fluids: Dimensions: Length Width Height Noise level 1~230V 50Hz 0,55 kw 6.5 l/min 1.8l/min 0.7 l/min 25/29 kg 4.0 l HLP32; HLP46 40 cm 28 cm 40 cm 82 dba 8

13. Electrical Diagram 9

14. Hydraulic Diagram Hydraulikschaltplan Hydraulic Schematic FE055-3-230V B A 0-700bar Ø100;Kl.1,0 90bar 10009 Ventilblock / Manifold 0-700bar 10006 =205V 10065 10041 20583 750bar 10094 AV75 10010 AV250 10011 RK0 20374 RK0 20374 PE15 10170 PE6 10168 PE8 10169 10095 Ölbehälter / Oil Tank Stand 14.12.2011 10