MODEL GS1-100 Air Filtration System. Operations Manual

Similar documents
MODEL FA1 Mini Air Filtration System. Operations Manual

FA1 Series Air Filtration System. Operations Manual

MODEL FA5 Air Filtration System. Operations Manual

MODEL MC1500 Installation and Operation Manual Important:

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BTX-208. Fume Extraction System _B

Model G14SD Vapor Management System

EXT DUCTLESS FUME HOOD

User s Manual and Operating Instructions

Installation & Service Manual for Portable Fume Collector. Model PFC-800

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

X-3400A, X-3500, X-3700 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS

MODEL SCA Installation and Operation Manual Important:

Model Numbers: MAC-36-BDF, MAC-42-BDF, MAC-48-BDF CONSUMER: READ AND SAVE THESE INSTRUCTIONS

MODEL MA4210 Installation and Operation Manual Important:

XS500 Load Bank. Read all instructions before using the load bank. Contents

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

SPH General Manual 400 Series

Miracle State Of The Art Air Filtration System!

X100P Load Bank. Read all instructions before using the load bank. Contents

Videojet Fume Extractor Preventive Maintenance Guide

MC2500. Installation and Operation Manual

OWNER S MANUAL C O M M E R C I A L I N D O O R A I R Q U A L I T Y S O L U T I O N S. Total High Efficiency Particulate & Gaseous Filtration System

Portable Air Purifiers

Quest H5. Quest Dry. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest H5:

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

SPEED KEY After the fan has started, press to change fan speed in sequence of: Low - Medium - High. The corresponding indicator will illuminate.

XS400 Load Bank. Read all instructions before using the load bank. Contents

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

Owner s Manual Phoenix GuardianR

Loctite Air Filtration System Part Number EQUIPMENT. Operation Manual

EXT HEPA/CARBON FUME HOOD

Operations and Service Manual. XE400D-SB Load Bank

Operating Instructions. International English. CCS Dust Extractor

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

AIR CLEANERS. Model MX 1800 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Air Bear Right Angle. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

HEPA AIR FILTRATION SYSTEM

OmniAire Portable Air Cleaner OA1200PAC

Omniaire 1000V Instruction Manual-8/05

Operations and Service Manual. X30208 Load Bank

MICRO-AIR AIR CLEANER INSTALLATION AND OPERATION MANUAL. MX3510 Includes Installation, Operation, and Service Instructions CAUTION

DUAL 12 Volt-10 Amp AUTOMATIC BATTERY CHARGER

XL1000 Load Bank. Read all instructions before using the load bank. Contents

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

Portable HEPA System

I-6500 Series. Industrial Applications. Operations & Maintenance Manual. Air Purifiers for. Manufactured. Serial number.

LARGE CAPACITY INCUBATOR Installation, Operation and Maintenance Instructions

Installation & Service Manual for Horizontal Cartridge Filtration Systems

6300 Series Owner/Operator Manual

PLANNING THE INSTALLATION

Table of Contents. Safety Information Main Functions Set-Up Operation Maintenance Troubleshooting Specifications Customer Support Warranty Information

AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER

WELDING FUME EXHAUSTERS & ARMS

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BVX-100. Fume Extraction System _B

Multistage Air Filtration Systems Instruction Manual

MODEL SAFETY & INSTRUCTION MANUAL

PHOENIX GUARDIAN H. E. P. A. SYSTEM

Powerful. Efficient. RED. Look to Micro Air Dust Collectors for clean air and cost-effective operation.

QPET, QPETXU Battery Chargers

16" STAND FAN WITH REMOTE

VERSATILE/PORTABLE CARTRIDGE DUST COLLECTOR V SERIES MODELS - VB, VF, VP

POWER PINNER CD HAND WELDER 7300 OPERATOR S MANUAL

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

D-Series Blowers and Exhausters

Owner s Manual Phoenix Guardian HEPA System

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer

User s Manual and Operating Instructions

INSTALLATION INSTRUCTIONS

quatroair.com AIR TECHNOLOGIES INC.

User s Manual D-Series Blowers and Exhausters

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

AMAIRCARE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS. Rules for Safe Installation and Operation

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

Air Bear Supreme and Air Bear Cub. Media Air Cleaners READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

BATTERY SAVER LOW RIPPLE HO

LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL


MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

Owner s Manual Phoenix Guardian HEPA System

OWNER S MANUAL PORTABLE POWER COMPACT & ROBUST

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

ROUSH FUEL SYSTEM UPGRADE CURRENT FORD MUSTANG 5.0L

The BVX-100 Fume Extraction System

ALU-29CF Portable Light NSN:

MOBILE FILTRATION FUME CABINET

10 AMP ON BOARD BATTERY CHARGER

GSL Electronics Modified Sine Wave Power Inverters

Transcription:

MODEL GS1-100 Air Filtration System Operations Manual READ AND SAVE THESE INSTRUCTIONS ARNING: Disconnect from power supply before performing maintenance procedures such as cabinet cleaning, changing filters or servicing of electric motor or other electric components ARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device. ARNING: For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors. CAUTION: Do not operate without having all filters in place. Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Arrange cord away from traffic area and where it will not be tripped over.

GETTING STARTED I n i t i a l s e t - u p 1. Open all cartons & locate Hose/clamps & heels 2. Remove ALL filters & packing materials from cartons and inside the GS1-100 cabinet 3. Place the GS1-100 on its side & install wheels in bottom plate 4. Remove plastic wrap from gas filter (Part # FA201D) 5. Carefully remove perforated cardboard from top and bottom of filter to expose filter media 6. Place gas filter (Part # FA201D) into bottom of cabinet note direction of airflow arrow 7. Place polyester pre-filter ( Part # FA103) on top of panel filter 8. Close and latch lid L o c a t i n g t h e a i r c l e a n e r : Placing the GS1-100 as close as possible to the pollution source reduces the amount of hose or duct required, reduces back-pressure, lowers power consumption and improves overall performance. heels are standard equipment on the GS1-100, but rubber isolators are available if the unit is to be placed permanently in position. If you prefer isolators, call 800-432-7550 to arrange a no-charge exchange. I n l e t h o s e a t t a c h m e n t : The GS1-100 ships standard with a 1 x 3 or 2 x 2 inlet (for single 2 applications one inlet is capped) place the flex hose over the metal air inlet tube and tighten securely with the stainless steel clamp. Connect the hose to a Fumex suction hood or place as close as possible to the pollution source. E l e c t r i c p o w e r The GS1-100 is manufactured for use on 115/1/60 (5.7 amps) or 230/1/60 (3.8 amps) power. Confirm that correct power supply is available. 2

CONTROLS On/Off Switch Simple one touch controls Green light indicating blower speed will confirm power to the unit. Blower/Fan The GS1-100 utilizes a variable speed blower with three speed settings. Press the fan button to adjust speed control. Green light will indicate current speed. Filter monitoring The GS1-100 contains a VOC indicator to monitor odors/gases in the exhaust stream. hen the gas filter becomes saturated (breakthrough occurs) the Change Gas Filter warning light will illuminate. GENERAL FILTER CARE Fumex GS1-100 air filtration systems feature a multi-stage filtration system designed to remove a wide range of pollutants from a process plume in an extremely efficient, cost-effective manner. S T A N D A R D F I L T E R S : Part # 103 Polyester pre-filter The disposable polyester pre-filter is the first stage of the filtration process. Its main function is to remove dust particles 100 and larger in advance of the more carbon filter. Replacement: The service life of the polyester pre-filter is determined by the type and volume of large particles collected. Part # FA201D Gas / Odor Filter Most process plumes contain several gases, some odorous some not, some toxic at elevated concentrations some completely harmless regardless of concentration. To ensure employee safety the type and concentration of pollutants must be determined. Please contact Fumex Engineering for selection assistance. The GS1-100utilizes a blended activated carbon and activated alumina impregnated with KMnO4 filter to capture and treat gases/odors. This combination of materials provides protection across a broad range of gases commonly found in industrial manufacturing processes. Replacement: The life of the gas/odor filter is highly dependent on the type and quantity of gases extracted from the process. Average service life is 4-6 months. 3

G E N E R A L M A I N T E N A N C E 1) The blower motor is a sealed unit, 24,000 hr. MTBF rated. It is permanently lubricated and does not require oiling keep it free of dust accumulations to prevent overheating. 2) Remove any loose accumulations of dust/debris from the air filter chamber periodically. This product employs overload protection (fuse). A blown fuse indicates and overload or short-circuit situation. If the fuse blows, unplug the product from the outlet. Replace the fuse as per the user servicing instructions (follow product marking for proper fuse rating) and check the product. If the replacement fuse blows, a short circuit may be present and the product should be discarded or returned to an authorized service facility for examination and/or repair Remote Start/Stop (Optional) The GS1-100 can be supplied with an optional remote start feature. If this option is factory installed on your unit, simply provide 24v to the red wire and the black wire is common. The unit will start when the signal is applied and turn-off when signal is removed. ARNING Connect Remote Starter Cable to 24v, Class 2 Power Supply Only ARNING Disconnect From All Power Supplies Before Servicing 4

R e p l a c e m e n t P a r t s P a r t # I t e m P a r t # I t e m C a b i n e t r y E l e c t r i c a l FA108 heels, standard FA97 Blower motor ass y, 115/1/50-60 FA109 Vibration Isolators FA96 Blower motor ass y, 240/1/50-60 FA117 Cabinet latch FA003 Control board assembly FA118 Cabinet hinge FA114 Fuse, 10 amp (120vac) FA106A Flanged air inlet 3 FA114A Fuse, 15 amp (240vac) FA106B Flanged air inlet 2 x 2 FA115 Cordset (120vac) FA115B Cordset (230vac) FA113 Fuseholder F i l t e r s G a s F i l t e r s FA103 Polyester pre-filter FA201D A/C + A/A cell w/ KMnO4 FA101B Activated carbon a r r a n t y a n d L i a b i l i t y l i m i t a t i o n s : Fumex FA1 air cleaners are guaranteed for 24 months from date of invoice to be electrically and mechanically sound. This warranty covers the material and workmanship only. Any defective item will be repaired or replaced, at our option, free of charge provided it has not been misused, abused, or otherwise damaged and is returned PREPAID to: Fumex, Inc. 1150 Cobb International Pl., Kennesaw, GA 30152 There are no warranties which extend beyond the descriptions set forth in this warranty, notwithstanding any knowledge of Fumex, Inc. regarding the use or uses intended to be made of goods, proposed changes or additions to goods, or any assistance or suggestions that may have been made by Fumex personnel. Customer is responsible for determining the suitability of Fumex products for customer s use or resale, or for incorporating them into objects or applications which customer designs, assembles, constructs or manufactures. Fumex reserves the right to discontinue any item and to make changes in the specifications, terms and conditions or prices at any time without prior notice. Information furnished in the specifications is believed to be accurate and reliable at time of printing, however Fumex accepts no responsibility for product use, or the effect of future design or specification changes. For Assistance or Technical Support please Contact Fumex Inc. phone 770-514-7907 fax 770-514-1547 USA toll-free 800-432-7550 www.fumexinc.com Fumex, Inc. 1150 Cobb International Place Kennesaw, GA USA 30152 Fumex, Inc., 2009, all rights reserved. Specifications subject to change without notice 5

GS1 DIGITAL UNIT 120/240/1/60 MOTOR F U S E PLUG CONN #3 CONN #2 CONTROL PANEL CONN #1 POS NEG LEGEND HITE 1 REMOTE START CONECTOR 2 THREE PIN CONNECTOR 3 FIVE PIN CONNECTOR 6

RELAY ACTIVATION PROCEDURES FOR GS UNITS 1. Remove all power sources from GS unit 2. Locate eight screws securing cabinet bottom panel 3. Remove all and gently pry bottom panel loose CAUTION Do not work on panel with power applied Relay activation jumper 24 volt start connector 4. Locate relay activation Jumper on rear of control panel. (Small plastic rectangle) 5. Gently remove jumper by pulling cap off pins. Shorting cap should be installed over a single pin for storage and to prevent loss of cap. Once the jumper has been removed the unit will only start by applying the proper voltage to the start stop relay. hen the unit is running the on and off switch can be used as long as start relay has power. 6. Reinstall bottom panel and screws 7. Apply power to start relay (see wiring diagram for your unit) 7