Indoor air quality sensor.

Similar documents
HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

PSK203/PSK223/PSK233. Digital Thermostats for Low Temperature Refrigerating Units 1 GETTING STARTED PSK203 PSK223 PSK233

Idle Free Systems, Inc. Reference Guide System Component Information

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

FlexCharger Battery Chargers

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

HWP Protection Board

TRIPS AND FAULT FINDING

Electrical Energy and Power Ratings

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

INSTALLER MANUAL USER MANUAL. Contents

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Designed for ease of integration with automation systems

Driftsinstruks. Utopia kontroller feilkoder PCP-2HTE og PC-ART. Vi håper de får stor glede av et Novema kulde produkt!

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.

Application Engineering

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

Instructions for the BASIC BCVA Rotary heat exchanger, Sizes

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.

WIRELESS CONTROL MODULE (WCM)

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

4.2 Component Identification

eapu Reference Guide System Component Information (For serial numbers starting with 37)

ECONOMISER SERIES E2T USER MANUAL

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

PRO series programmer

Installation Instructions

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

ECM-MSPD. Installation, Operation, and Maintenance Manual

B-PC20 Power Close Module

CX-SERIES ADVANCED BATTERY CHARGER

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires it.

Advanced EasyStart Troubleshooting

Table of Contents Foreword I. Product Introduction II. Notice For Safety III. Main Technical Parameters IV.

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

C RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

AS-4000 OPERATING INSTRUCTIONS (PS-5000)

Electronic Ballast EVG 2000-T

Application Engineering

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

INSTALLATION INFORMATION

General Precautions. Personnel Precautions

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

GLM SERIES CONTROL Users Manual Rev:

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

CFT24 &CFT230 PART NOS:

GENERALITIES TECHNICAL FEATURES

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

A U T O M A T I C T R A N S M I S S I O N M U L T I - C H A N N E L T W O - W A Y L C D R E M O T E S T A R T E R AS-2510 TW.

EasyStart. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

An ISO 9001:2008 Registered Company

Artesis MCM Case Studies. March 2011

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

GRD502-B Flow Chart 02/05/09

3. SERVICE TOOLS Inverter checker RSUK09-17 CLIMATE COMFORT. All Seasons. Heating. Air Conditioning. Applied Systems.

CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS...

REVISION HISTORY REVISION HISTORY

SE8300 Series Installation Guide 24 Vac Low Voltage

BOX A3 TEST REL. DATE R.T. Check and Approval

CAUTION All safety information must be followed as provided in Service Manual

User Manual. 1. Introduction

1998 INDEX Sensors & Controls, Inc. All Rights Reserved

37. FATC (FULL AUTO TEMP. CONTROL) CIRCUIT 6810

Introduction...3. System Overview...3. PDC Control Unit Sensors PDC Button Interfaces Activation of the PDC...

Service instructions. MAGNA Series 2000

GTWY605 Fast Idle, Shift Interlock, I/O Chevy 610 Van - 6.0L and 6.6L Engines Contact InterMotive for additional vehicle applications.

Emergency lighting units EM series

SLIMZONE CLASSIC /

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Programmable 8 Channel Injector Driver Module

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

ATOTH-G Series BLDC Motor Controller. User s Manual

OUTDOOR UNIT CONTROLLER (OUC)

EconoMi$er, Power Exhaust, and Sensor Installation Instructions

Installation Instructions

SiCan Simple CAN Extension Charger to PacMon

Installation and Operation Back-UPS BX550CI-CN

2001 Chevrolet Corvette ACCESSORIES & EQUIPMENT Remote Keyless Entry Systems - Corvette

INSTALLATION INSTRUCTIONS CMH-7A LOW AMBIENT CONTROL

EFC Instructions Manual

USER MANUAL DCA15. Auto Aır Conditioner Controller Unit. Elektrosan Elektronik Müh. San. Ve Tic. Ltd. ENG. DCA15 V01 03/17

PANcharge1k Battery Charger User's Manual

Operators Guide: RoboSign Stop/Go Traffic Control System

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

SDM72 Start on Demand Modules

Operating manual and installation instructions ENGLISH. Electronic engine remote control. Copyright 2001 Vetus den Ouden n.v.

5. OVERCURRENT RELEASE (OCR)

CD100 Series. Operators Manual SINGLE COLUMN CARD DISPENSER

Optional: Wiring a Relay for Gauge Controlled Output

SECTION B Supplemental Restraint System

Installation, Operation and Maintenance Manual

Aura Interior Wiring Manual (5-Wire and BACnet)

i-drive, i45 & i90 DIAGNOSTIC GUIDE

ACTIVA SERIES ROOF TOP Air Conditioners 100/175

PUR (A, B, C, D) INSTRUCTION FOR VARIABLE SPEED WITH WIRING DIAGRAM FOR EMX P10 ROTOR SIZE

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Transcription:

Indoor air quality sensor. Options and Accessories, Installation manual Ref.: N-40175_EN 1107

Index Index 1 Indoor air quality sensor... 1 1.1 General Information... 2 1.2 General measurements... 2 1.3 Technical specifications... 2 1.4 Assembly... 3 1.5 Operations... 3 1.6 Installation... 4 1.6.1 Buttons and LED... 5 1.6.2 Configuration... 5 1.6.3 Accessories and sensors... 6 1.7 Wiring diagram... 7 i

1 Indoor air quality sensor

1 Indoor air quality sensor 1.1 General Information 1.1 General Information The sensor measures the degree of pollution due to different reasons such as the level of room occupancy, tobacco, kitchen smoke, carbon monoxide, etc. When the pre-set limits are exceeded, the control acts on the economiser, adjusting the outside air damper. This option requires the economiser for it to work properly. 1.2 General measurements Measurements in mm 1.3 Technical specifications This accessory includes the following components: Air quality sensor. Signal conversion board from 230 V AC to 5 V DC. Connection cable for sensor fitting inside machines. 2

Indoor air quality sensor 1 Assembly 1.4 1.4 Assembly Sensor installed on the return side inside the machine A. Indoor air quality sensor. B. Rain protection assembly and economiser (existing). Sensor installed in room The place where the indoor air quality sensor is to be installed in the room -A- must be representative of its air quality level. It must be installed on a wall free of obstacles at a distance of 1.5 to 3 m from the floor. Sensors should not be installed behind curtains or shelving or in gaps or areas where people are permanently present (in this case, the minimum distance should be 1 to 2 metres). X = 1.5 3 m. 1.5 Operations The air quality sensor has a VOC (volatile organic compounds) sensor that compares their concentrations in the air with the setting selected on the sensor. Where the value is higher than the setting, the sensor triggers output Y1 using a relay. The 230 V AC output signal between Y1 and N is connected to conversion board of 230 V AC to 5 V DC. This board is fitted alongside the economiser control board. The 5V DC signal cable must be connected on connecting J18 on the economiser board. Where the thermostat setting temperature of the room is met and there is an air quality request signal, the damper is opened to the programmed renewal minimum and the inside fan starts up. The damper then opens further, bearing in mind the maximum (30 C) and minimum (12 C) supply temperatures. In the following cases: Disappearance of the air quality request signal, the thermostat makes a cold or heat request The damper returns to the renewal minimum. Where there is no request from the thermostat and the inside fan is in automatic mode, the fan will stop and the dampers will close. 3

1 Indoor air quality sensor 1.6 Installation A. Connection terminals. B. Air quality level selection. C. VOC sensor. Three air quality levels can be selected on the sensor according to the bridge positions: 0: Normal, default position. -: Acceptable. +: Very good. 1.6 Installation N O T E The electrical connection for the sensor will be different depending on the place where it is installed. Bear in mind the current regulations in the country where the equipment is to be installed. Disconnect the power supply to the unit using the main switch -Q3- (See Installation Manual). Install the air quality sensor on the return side of the economiser separator panel or inside the room. Install the 230 V AC to 5 V DC signal conversion board alongside the economiser board. Previously remove the plastic cover and secure the board using the plastic separators on the plate support. Connect the 5 V DC signal cable on connecting J18 on the economiser board. Sensor installed on the return side inside the machine: Connect the black and blue wires (386 and 387) of the economiser cable (inside the cable ducting on the electrical box side) to X1 terminals L and N, respectively. Then connect air quality sensor terminals L and N. Run the brown (Y1) and blue (N) wires from the sensor to the signal conversion board. Sensor installed in room: Install a 4 x 1 mm 2 cable (black, blue, brown and yellow-green) from the electrical box on the unit to the location where the sensor is to be installed in the room. Connect the black (L), blue (N), brown (Y1) and yellow-green (earth) wires to the X1 connector terminals and to the sensor. Then connect wires 387 (N) and 386 (Y1) to the side of the electrical box (connector X1) and to the side of the signal conversion board. Checking the correct working order of the sensor: Set the thermostat so that the room temperature is met. Bridge terminals L and Y1 or make the sensor detect smoke to check that the output relay is triggered. The damper should open very slowly. C A U T I O N Loose connection terminals produce overheating of cables and terminals. The unit is working incorrectly and there is a risk of fire. Check that the cables are firmly secured to their connection terminals. 4

Indoor air quality sensor 1 Installation 1.6 C A U T I O N Do not turn on the general switch on the unit or start the unit until all installation work has been completed. 1.6.1 Buttons and LED Buttons There is a button on the main electronics board called the test button that has several functions depending on the way it is pressed: - As a LonWorks service pin: whenever it is pressed, it sends the Neuron ID via the LonWorks network. - Shortens certain times and resets any fault detected if pressed until the green LED lights up. - Identifies the optional accessories and sensors connected to the board if kept pressed down until the red LED lights up. LED There are three LED signalling diodes: The green LED indicates whether the equipment is working properly or if there are incidents. If the equipment is working properly, this LED will flash at a frequency of 1.43 Hz. (0.70 sec). The red LED indicates faults. If there are not faults, the LED will remain switched off. It also lights up when accessory configuration is being scanned. The yellow LED performs the functions of the LonWorks service LED and also indicates that a compressor time is running when it flashes. Where the red and green LED remain lit, the configuration must be reloaded on the board. It can only pass through communications in the event of decommissioning. There is a green LED on all accessories that flashes when communications are sent to them. It will therefore indicate that it has been correctly identified. If the LED remains on, it indicates that the accessory is powered but either it has not been correctly identified or it is not receiving the communications. There is a yellow LED on the economiser that indicates that the outside air is favourable when it is lit and a button that, together with the potentiometer, stores the renewal minimum position (see the Economiser Installation Manual). There is also a yellow LED on the hot water coil that indicates if the water temperature is favourable (LED remains lit) or if the coil is performing a defrost function (LED flashing). 1.6.2 Configuration Every time the electronic board is powered with 24 V AC the system configuration is checked as follows: 1 Micro-switch reading. 2 Communications transceiver identification. 3 Thermostat communication check. 4 Check and enabling of all located accessories. The first two tasks are not carried out at any other time. The third is carried out once a minute when communication cannot be established. The fourth task is also carried out on resetting faults and when accessories are located. The micro-switches are consulted every time the electronic board is powered with 24 VAC. The board will act according to their positions. 5

1 Indoor air quality sensor 1.6 Installation N O T E Where SW1 and SW2 are OFF, configuration is carried out remotely via the communications system. Micro-switch configuration: Number Status Meaning 1 / 2 4 5 6 7 8 OFF/OFF ON/OFF OFF/ON ON/ON ON OFF ON OFF ON OFF ON OFF Pay no attention to the SW, they are programmed via communications. Defrosting time 0 sec. Defrosting time 60 sec. Defrosting time 90 sec. Crossed coils. Independent coils. Compressor delay 2 sec. Compressor delay 5 sec. Cold only selection. Heat pump selection. 4-way valve active in heat. 4-way valve active in cold. ON Thermostat with signal B. OFF Thermostat with signal O. ON OFF Fan enabled during defrost. Fan disabled during defrost. Transceiver ID Every time the electronic board is powered with 24 V, the transceiver installed is recognised and the communications parameters adapted. If the identifier is unknown, an incident will be indicated. When an SMX transceiver is used, the green LED on the board will flash at a frequency of 0.8 Hz (1.25 sec) to indicate that it has recognised it. 1.6.3 Accessories and sensors Accessories are installed for the extended operating of the equipment. These accessories can be factory or site-fitted. Disconnect the power supply to the unit using the main switch -Q3- (See Installation Manual). Then install the accessory and all necessary parts and re-connect the power supply. Press the test button for more than three seconds to search for and configure the accessories installed until the red LED lights up. When the search and configuration process starts, the red LED on the board will light up and will remain on until the operation is completed. Once switched off, the board will manage the located accessories. The optional sensors to be connected to the board are also chosen during the search. If any of the optional sensors configured ceases to generate correct values, an incident is generated. In the case of the supply sensor, which may be fitted to connector J6 on the second compressor board, to connector J6 on the economiser board or to connector J6 on the hot water coil board, an attempt will first be made to identify it on the second compressor and, where it is not located, on the economiser or on the hot water coil. 6

Indoor air quality sensor 1 Wiring diagram 1.7 1.7 Wiring diagram 7

1 Indoor air quality sensor 1.7 Wiring diagram 1. F11 KM11 M11 X2-R 2. Accessories 3. Accessories 4. 5. Optional Reg. 1 A (090, 120, 150). Reg. 1.4 A (180, 240, 300). Reg. 1.4 A (180, 240, 300). A1 to X2-7 (Cable 583) A2 to X2-B Exhaust fan 24 VAC Phase-R switching X2-7 To A1 from KM11 Air quality sensor, optional, fitted on return (inside machine) L N Y1 Black Blue Brown Air quality sensor, optional, fitted on ambient (machine exterior) L N Y1 6. Air quality board (green) 7. 8. B15 B16 B17 M10 X1 Black Blue Brown Yellow-Green Enthalpy sensor C7400A return, optional + Red S White Enthalpy sensor C7400A outside, optional + Red S Return sensor (black) White Discharge sensor, optional depending on model (yellow) Inside sensor (white) Damper 0-10 V Grey C R Black Red Cables to be installed on site (not supplied) Data and measurements subject to changes without prior notice. 8