Variety of mounting methods. UL, CUL, and CSA listed for general and hazardous locations

Similar documents
CRYSTALGLO. Holophane s potted ballast provides good thermal dissipation and sound absorption, for long life and quiet operation.

ENDURALUME HL /02

Predator Medium Floodlight Wet Location

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

AFL FLOODLIGHT SERIES

PRISMALUME ENCLOSED HL /03

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

Applications. Standard Materials

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

Pole Series. Series Reflector Lens Mounting Lamping Finish Voltage. S w S w S w S w

Applications. Standard Materials. Certifications and Compliances

Lighting: Explosionproof Area HID. Applications. Standard Materials

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

Overall Dimensions. Specifications

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

ORDERING INFORMATION: 120 Volts (120)

Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4" (387mm) 15 3 /4"

Applications. Standard Materials. Certifications and Compliances

HOLOPHANE Outdoor Lighting

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Project: Type: Qty: QH2L. Options QH2L 27 3 /8" 23 3 /16" 3 1 /2" O.D. Pole. Options

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

Areamaster LED Flood/High Bay Luminaires

Project: Type: Qty: SA1L. Optics Mounting Light Engine CCT Finish Voltage Options. Series SA1L-XX-1-NH SA1L-XX /2" O.D.

Prismalume. Enclosed HOLOPHANE

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot

Prismpack. V Enclosed HOLOPHANE

Overall Dimensions. Specifications

N2MV Series W Non-metallic

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

Options. Pole and Arm. Suitable for wet locations

LEDMPAL15 15 Watt Multi-Purpose LED Area Light

KAD250MR3TBSPD04 Wall Fixture

DECORATIVE. Tear Drop Series

LEDMPALPRO LED Area Luminaire

Qty: L50 50W. B4 Two 12V 146 Ah. B5 One 12V 176 Ah. P4 150W Double. 4 XXX 4 hours PM 0 hours AM. 5 XXX 6 hours PM 0 hours AM PM4 45 PM6 60.

PRISMALUME HL-755 8/02

Standard Grade 14 Inch Reflector. Ordering Information

Capella 3. Project Name. Construction. Optical System. Product Applications

H700 H710 H720. Compact Flood. Typical Applications. Features. Lamp Types. Approvals SPECIALTY LANDSCAPE

80 Watt Multi-Purpose LED Area Light

IMPORTANT SAFETY INSTRUCTIONS

Ritorno Square Asymmetrical LED

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

Applications. Illustrated Features

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120

Series Optics Mounting Lamping Finish Voltage. H039T6 1 39wT6 H w. H w. (T6 only available with MA and MS refractors) 12 3 /8" (314mm)

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations

MVOLT

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

003 3 foot foot RUN Nominal Length* * For actual lengths see

Project: Type: Qty: Height Lamping Finish Voltage Options. Series MTRQ /8" (1252mm) /16" (551mm) Options


GreenCobra LED Street Light GCL G-Series Specification Data Sheet

Project: 1 IP65 Rated fixtures are rated for use outdoors where exposed directly to water from rain or irrigation.

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area.

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor

Qty: R4 Type IV Distribution. B4 Two 12V 146 Ah. B5 One 12V 176 Ah. P4 150W Double. 4 XXX 4 hours PM 0 hours AM. 5 XXX 6 hours PM 0 hours AM PM4 45

MetroVue HOLOPHANE THE

VINCI-LED Wall/Area/Flood Lighting

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

1 With internal stepdown transformer 26 7 /8" (683mm)

Evolve LED Area Lighting EALS

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE

ORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480)

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812

LUM SERIES-PLED w/ POLE RATED FOR 100MPH SHAFT

OP2 CosmoPolis Series

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Floodlight. AF1000 Series. Aktra Cutoff Floodlight W HID

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

Bavaria Downs. Chaska, MN. Lighting

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

E-Cobra LED Street and Area Light EC M2 Series Specification Data Sheet

PGL350P W PS Wallpack

Qty: B B lm/6.9W per foot. per foot. 2B lm/15.3W per foot. 2B lm/13.

Prismpack V, Prismalume V, Large Prismpack, Large Prismalume

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

Evolve LED Area Lighting EALP

Perimaliter Wallpacks

Glass Washington Postlite LED HOLOPHANE. Decorative Glass Washington Postlite LED

Explosion Proof Dock Light - Class I, Div. I, Groups C & D - 70 Watt LED Lamp - Extension Arm

Post Top Globes. ACL Large Acorn Post Top Globe Page 109. ACS Small Acorn Post Top Globe Page 109

GE Evolve LED Area Lighting Scalable EASC High Lumen


SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications

ARIETA 13 Architectural LED Area Luminaire AR13 M2 Series Specification Data Sheet

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

TORNADOTM BOLLARD PATENTS PENDING

CC/CCS21 21" Post Top Mounted, Curvilinear, LED revision 5/9/11 kim_cc21pled_spec.pdf

ARIETA 18 Architectural LED Area Luminaire AR18 M2 Series Specification Data Sheet

Transcription:

PREDATOR The Predator floodlight offers versatility, efficiency, and performance, which provides a unique solution to a variety of lighting needs. With the Predator, Holophane continues its legacy of utilizing technology to develop creative and innovative lighting solutions. Because the Predator is capable of generating wide, narrow, and spot distributions and is able to withstand harsh environmental extremes, it can be used in a range of diverse applications. Flexibility in mounting positions is maximized with its 360 yoke. The quick disconnect removable door, which includes all electrical components, can be replaced in 60 seconds, resulting in decreased costs and inconvenience of downtime

PREDATOR Variety of distributions Extended component life Variety of mounting methods UL, CUL, and CSA listed for general and hazardous locations Features and Benefits Unique fluted reflector Produces the maximum amount of light per input watt with optimum uniformity. Transverse elliptical fluting minimizes redirected energy through the arc tube and provides streak and striation free illumination. Unitized electrical assembly Quick disconnect fixture door includes ballast and socket. Simplifies maintenance through 60 second replacement and decreases costs through minimal downtime. Corrosion resistance Construction consists of low copper (360.1 alloy) aluminum castings, phosphate pretreatment, 2 4 mil TGIC polyester powder paint, and hollow core high temperature silicone gaskets. 40 C UL listing Extends ballast and capacitor life 100% if operated in 25 C (77 F) average ambients.

BRIDGES PAPER MILLS POWER PLANTS PETROCHEMICAL PLANTS WASTEWATER FACILITIES BUILDING FACADES PARKING LOTS OUTDOOR SECURITY Application versatility Protected HPS starter Protects starter and ballast from damage when lamp fails. Mounting versatility 360 yoke for 100% flexibility. Knuckles for 2 and 4 inch tenons. Junction box mount. Stainless steel exposed hardware Provides long useful life in harsh locations. Low Energy Use Holophanemanufactured ballasts provide highest lamp wattage with lowest input watts. Optional low loss ballasts in 250 400W MH reduce losses by an additional 10 to 20 watts per fixture. Normal environment - UL/ CUL 1598 Suitable for Wet Locations Harsh environment - UL 844 Class I, Division 2 Class II, Division 1 & 2 (small Predator only) Class III, Division 1 & 2 (small Predator only) CSA Certified UL 1598A* Marine Outside *There are 4 levels of marine listings defined by UL 1598A, with Marine Outside having the most severe requirements. PREDATOR

PREDATOR Predator CI Fixtures Class I, Division 2 Groups A, B, C, D Hazardous Locations Predator has been designed and tested in accordance with UL Standard 844. Therefore, it complies with Article 501.9(B) (2) of the National Electrical Code, specifically, tested in order to determine the marked operating temperature or temperature range. Predator CII Fixtures Class II, Division 1 & 2 Groups E, F, G Class III, Division 1 & 2 Hazardous Locations Predator has been designed and tested in accordance with UL Standard 844 to be dust-ignitionproof as required for Class II applications. The fixture will exclude dust from the inside of the enclosure and will function at full rating without developing surface temperatures high enough to cause excessive dehydration or gradual carbonization of any organic dust deposits that may build up. Maximum surface temperatures will not exceed 200 C (392 F) Group E and Group F or 165 C (329 F) Group G under normal conditions of use. All temperature classifications are for 40 C ambient temperature. Table 1 lists the UL tested maximum operating temperatures for lamp type and wattage based on operation in the specific ambient for which it is approved. Please refer to the Maximum Surface Temperature Code Table of the NEC. Table 1 Predator Temperature Classification for Class I, Division 2, Hazardous Locations and Class II, III, Division 1 & 2, Hazardous Locations. Class I, Division 2 Class II, III, Divisions 1 & 2 Lamp Type Maximum Mounting Lamp Type Maximum Mounting & Wattage Temp. C Code Restriction & Wattage Temp. C Group Code Restriction 50W HPS 163 T3B 1 50W HPS 163 E,F,G T4A 2 70W HPS 178 T3A 1 70W HPS 178 E,F,G T3C 2 100W HPS 221 T2C 1 100W HPS 221 E,F,G T3C 2 150W HPS 55V 272 T2A 1 150W HPS 55V 272 E,F,G T3C 3 150W HPS 100V 244 T2B 1 150W HPS 100V 244 E,F T3A 3 250W HPS 323 325* 1 150W HPS 100V 244 E,F,G T3B 4 400W HPS 388 T1 1 175W MH 306 E,F T3 3 175W MH 306 325* 1 175W MH 306 E,F,G T3C 4 250W MH 347 350* 1 100W MV 247 E,F,G T3C 2 400W MH 347 350* 1 175W MV 313 E,F T3 2 100W MV 247 T2B 1 175W MV 313 325* 1 250W MV 383 T1 1 400W MV 383 T1 1 1 Mounting restricted to lamp vertical, base down, +/- 90. 2 Mounting restrictions are referenced to lamp vertical, base down, 25 back of vertical to 90 lens down. 3 Mounting restrictions are referenced to lamp vertical, base down, vertical to 90 lens down. 4 Mounting restrictions are referenced to lamp vertical, base down, 90 lens down only. * UL Standards covering hazardous locations (UL 844) Paragraph 49.10 permits fixtures under Class I, Division 2, which are between 300 C and 450 C to be marked with 325, 350, 375, 400, 425, 450 to indicate actual maximum temperature. (e.g. Code 325 = 325 C) Note: Maximum temperatures for lamp type and wattage vary between Class I and Class II & III. Class I is established based upon the maximum temperature inside or outside the luminaire. Class II and III maximum temperature is based upon external surface temperature. Class III fixtures will exclude fibers or flyings from the inside of the enclosure and will function at full rating without developing surface temperature high enough to cause excessive dehydration or gradual carbonization of accumulated fibers or flyings. NEC Requirements UL Standard 844, File no. E12267

Performance Specification Table 2. Photometric Data Vertical NEMA Beam Total Max. Photometric Source Watts Distribution Beam 1 Efficiency 2 Efficiency Candela Test # HPS 50 Narrow 7 x 5 64.2% 71.0% 3172 36339.IES Wide 7 x 7 69.4% 71.7% 1898 36363.IES 70 Narrow 7 x 5 63.4% 70.1% 4556 36337.IES Wide 7 x 6 68.7% 70.9% 2595 36361.IES 100 Narrow 7 x 5 64.3% 69.5% 6264 36335.IES Wide 7 x 6 68.0% 70.2% 4117 36359.IES 150 Narrow 7 x 6 65.3% 69.7% 9658 36333.IES Wide 7 x 6 67.6% 69.9% 6358 36347.IES Spot 4 x 4 47.8% 72.4% 29994 37019.IES 250 Narrow 7 x 4 66.6% 73.3% 20075 37199.IES Wide 7 x 6 70.1% 73.4% 13852 37200.IES Spot 6 x 4 64.7% 75.2% 25719 37198.IES 400 Narrow 7 x 5 67.0% 72.3% 29653 37196.IES Wide 7 x 6 69.6% 72.8% 22441 37191.IES Spot 6 x 5 64.6% 74.5% 42203 37197.IES MH 175 Narrow 7 x 5 65.5% 73.2% 10834 36343.IES Wide 7 x 6 70.9% 73.4% 5527 36367.IES Spot 4 x 4 51.4% 80.3% 23696 42320.IES 250 Narrow 7 x 4 59.2% 74.9% 19769 37218.IES Wide 7 x 6 72.2% 75.9% 11815 37219.IES Spot 6 x 4 56.6% 77.8% 24413 37217.IES 400 Narrow 7 x 4 64.1% 76.2% 32262 37202.IES Wide 7 x 6 71.4% 75.7% 19407 37201.IES Spot 5 x 4 59.5% 79.0% 43500 37203.IES DX MV 250 Narrow 7 x 7 67.4% 69.0% 4981 37224.IES Wide 7 x 7 67.0% 68.3% 4440 37225.IES Spot 6 x 6 66.5% 71.6% 7066 37223.IES 400 Narrow 7 x 7 63.0% 64.6% 7126 37208.IES Wide 7 x 7 62.5% 64.0% 6513 37207.IES Spot 6 x 7 64.1% 68.0% 11106 37209.IES 1 NCHA beam based on field angle 2 Beam efficiency based on field angles.field angles are used because they more accurately represent lumens in beam Fixture shall be Holophane catalog number. Mechanical Construction: The housing shall be die cast low copper (360.1 alloy) aluminum finished with a 7-stage pretreatment and an electrostatically applied 2-4 mil coat of polyester powder paint. The finish shall withstand a 160 inch-pound impact measured with a standard Gardner Impact Tester. It shall have passed a 1000 hour salt spray test as specified by ASTM B-117. It shall exhibit no cracking or loss of adhesion from a 180 bend over a 1/8 inch mandrel diameter per ASTM D522. All external screws shall be captive and be Type 316 stainless steel. The yoke shall be either AISI Type 316 stainless steel or zinc electroplated and yellow chromate finished cold rolled steel. The yoke shall be capable of being rotated 360 about the fixture for top, bottom, or back mounting. The door shall be hinged to provide easy access during lamping and shall be secured to the fixture while open. The door assembly shall include mechanical stops to assure proper compression of the gasket. The yoke mounted fixture shall have a threaded entry to accommodate 1/2 NPT conduit or connector. When the junction box mount fixture is used, a 1 NPT entry shall be provided. Water-tightness: No water shall enter the fixture when exposed to a solid stream of water from 3 GG40 brass spray nozzles - each supplying 12 gallons per minute at 100 PSI. The nozzles shall be 30 inches apart, centered on, and 24 inches from the fixture plane. Three tests shall be conducted for 15 minutes each with the vertical distance of the fixture at 6, 12, and 16 inches above the nozzles. The gasket shall be hollow core, Durometer 60 silicone, and have a 200 C continuous service temperature. It shall have demonstrated no visible deterioration after artificial aging for 96 hours in oxygen at a pressure of 300 pounds per square inch at a temperature of 156 F. Dust-tightness: An enclosure of a fixture for Class II locations shall be exposed for at least six heating and cooling cycles and for at least 30 hours to a circulating dust-air atmosphere to determine that the fixture is dust-ignition-proof with regard to exclusion of dust. There shall be no entrance of the dust into the device as determined by visual examination following the chamber test described. The fixture is to be installed in a test chamber to permit free circulation of the dust-air mixture around the fixture. The test chamber is to be provided with a cover and with dust-air-inlet and - outlet connections. The fixture is to be exposed to the dust-air atmosphere that is to be produced by auxiliary apparatus and introduced into the test chamber. The tests are to be conducted at an ambient temperature of 10-40 C (50-104 F) and a relative humidity of 40-60 percent. Grain dust consisting of wheat or com dust, or both, that has passed through a U.S.A. Standard 150-micron (100-mesh) wire cloth is to be used for the dust-air atmosphere if the fixture is for Class II, Group F, Group G, or Groups F and G locations. Magnesium dust, all of which has passed through a U.S.A. Standard 250-micron (60 mesh) wire cloth, 66 percent of which has passed through a 150-micron (100-mesh) wire cloth, and 22 percent of which has passed through a 75-micron (200-mesh) wire cloth, is to be used for the dust-air atmosphere if the fixture is for Class II, Group E, Groups E and F, Groups E and G, or Groups E, F, and G locations. Quick Disconnect Electrical: The fixture door shall contain all ballast components, including the socket, and be designed for fast removal as a complete assembly without disturbing aiming. The fixture shall be capable of being changed to a different wattage, voltage, or lamp source by simple change out of the unitized electrical assembly. Replacement shall take less than 60 seconds. Optical and Socket Assembly: The reflector shall consist of high purity alloy #3002 aluminum of minimum 0.08 thick sheet. Lens shall be 4.5 mm minimum thickness tempered glass. The beam efficiency shall be no less than *. The total efficiency shall be no less than *. Lamp holders shall be porcelain with high temperature 16 ga. wiring. Sockets shall be pulse rated. The screw shell shall be nickel-plated brass with anti-vibration grips. Ballast: Shall be copper wound, high power factor, Lead or Low Loss Lead as specified. Ballasts shall reliably start and operate the lamp in ambient temperatures to minus 40 F. The lamp extinguishing voltage shall be as low as 39% of nominal. Ballast shall provide 100% wattage to the lamp and have a published Ballast Factor of 1.0 per ANSI C82.2. The fixture shall be UL listed for 40 C. When operated at 10 C below rated ambient temperature, ballast insulation and capacitor life shall be extended 100%. The low loss ballast available for 250 400 watt lamps, if specified, shall have a core of grain oriented M-6 steel to reduce ballast losses 10 to 20 watts per fixture. A protected started for High Pressure Sodium lamps, if specified, shall sense an inoperative lamp and automatically shut down to prevent continuous pulsing and thermal damage to itself and ballast secondary windings. Warranty: The electrical assembly shall be warranted for a period of 5 years and the luminaire for a period of 2 years from the date of shipment. Listing: The fixture shall be UL/CUL 1598 listed for 40 C ambient Suitable for Wet Location. It shall be UL 844 listed for Class I, Division 2; Class II, Division 1 & 2; Class III, Division 1 & 2. It shall be UL 1598A listed for Marine Outside. *Note: See Table 2 for applicable beam efficiency and total efficiency. PREDATOR

PREDATOR Mounting versatility Since the yoke can rotate 360 around the fixture, the Predator can be mounted from below, above, or any intermediate position. An optional knuckle fitter, adjustable in 5 increments, can be ordered in lieu of the yoke, or a slip fit adaptor can be supplied as an accessory to the yoke for mounting on a 2" tenon. For ceiling mounting in tunnels or back mounting for sign lighting, a box mount can be supplied in lieu of the yoke to give a 15 tilt from the mounting plane. The knuckle fitter, junction box, and slip fit adaptor options are not suitable for hazardous locations. 1 3 2 5 4 6 1 Housing: Low copper (360.1 alloy) die cast aluminum with polyester powder paint. 2 Mounting: 360 swivel of mounting yoke around fixture provides top, bottom, or back mounting. 3 Reflector: Unique reflector design eliminates bright streaks, provides uniform illumination, and low surface brightness. 4 5 Tempered glass lens Quick-disconnect removable door: Includes all electrical components, including the socket. Captive stainless steel screws. Door does not distort when fastened. 6 Gasket: Hollow core high temperature silicone gasket. Junction box mount 08657 2" Tenon pole adaptor Knuckle fitter Mounting Options

Ordering Data How to construct a catalog number for Predator Fixture type EXAMPLE: PD 050HP 12 H N 3 G PS 1 2 3 4 5 6 7 8 Catalog no. Description 1 Luminaire type PD Small Predator (UL 844, UL 1598A, UL/CUL 1598, 40 C wet location) PF Medium Predator (UL 844 and UL/CUL 1598, 40 C wet location) 2 Source and wattage PD 050HP 50W HPS (120 volt only) H 070HP 70W HPS 100HP 100W HPS 15AHP 150W/55V HPS 175MH 175W MH PF 250HP 250W HPS 25LHP 250W HPS, energy saving W 400HP 400W HPS 40LHP 400W HPS, energy saving 250MH 250W MH 25LMH 250W MH, energy saving 40LMH 400W MH, energy saving 250MV 250W MV 400MV 400W MV 3 Voltage 12 120 volt 20 208 volt 63.5mm (2.5 ) 31.8mm (1.25 ) 24 240 volt 25mm (1.0 ) 27 277 volt 34 347 volt (Canada only) 48 480 volt MT Multi-voltage (120-277 volt USA) NA with 050HP, 250 and 400MV 4 VT Vari-tap (120, 277, 347 volt) Only available with 250HP, 250 MH, 400HP UL/CUL listing PD H Class I only (UL 844) J Class I, II, III, and marine outside (UL 844) K Wet location (UL/CUL 1598) L Marine outside (UL 1598A) PF B Class I (UL 844), and marine outside (UL 1598A) K Wet location (UL/CUL 1598) L Marine outside (UL 1598A) 5 Optical N Narrow vertical, wide horizontal beam W Wide vertical, wide horizontal beam S Spot distribution (UL/CUL 1598 & UL 1598A on PD only ) 6 Mounting 1 2 Knuckle fitter (UL/CUL 1598 only) 2 Box mount (UL/CUL 1598 and UL 1598A only) 3 Stainless steel yoke 4 Zinc plated yoke (UL/CUL 1598 only) 5 4 Knuckle fitter (UL/CUL 1598 only) 7 Color G Gray B Bronze K Black (UL/CUL 1598 on PF only) W White (UL/CUL 1598 on PF only) 8 Options and accessories See page 8 51mm (2.0 ) 2X 10.7mm (.422 ) (2) clearance holes for mounting bolts (1) 13.5mm (.53 ) hole for wiring Predator W H D Weight PD 13.125 17.875 7.875 20-23 lbs. PF 16.875 22.75 10.5 39-46 lbs. Effective Projected Area (In Ft2) Tilt above Small Predator Medium Predator Nadir EPA EPA 15 1.14 1.86 45 1.66 2.66 90 1.93 2.87 135 1.70 2.45 180 1.14 1.61 D Protractor markings every 15 for a 180 total - 2 places Clearance holes for luminaire mounting Order number Job name PREDATOR

Options and Accessories Wire guard Visor Visor & side shield Catalog no. Options (factory installed) A Gray top visor C Bronze top visor D Gray side shield (UL/CUL 1598 only) E Bronze side shield (UL/CUL 1598 only) F Black top visor (UL/CUL 1598 on PF only) H White top visor (UL/CUL 1598 on PF only) L Black side shields (UL/CUL 1598 on PF only) J White side shields (UL/CUL 1598 on PF only) PS Protected starter for HPS units only R 1 Photocontrol receptacle (NEMA twistlock) (UL/CUL 1598 on PF only) _ TB 1 Terminal block Accessories (shipped separately) LAMP Ship appropriate lamp as line item F1 Single fuse assembly for 120, 240, 277, or 347 volt (UL/CUL 1598 only) F2 Double fuse assembly for 208, 240, or 480 volt (UL/CUL 1598 only) PDWG Wire guard for PD unit PFWG Wire guard for PF unit PDPR12 120V photocontrol (UL/CUL 1598 only) PDPR 208, 240, 277V photocontrol (UL/CUL 1598 only) PDPR34 347V photocontrol 08657-xx 2 2 tenon pole adapter (UL/CUL 1598 only) Notes: 1 Contact TSG 2 Insert GR-Gray, BZ-Bronze, BK-Black, WA-White for xx in catalog number Acuity Lighting Group, Inc. 214 Oakwood Ave., Newark, OH 43055 / Holophane Canada, Inc. 9040 Leslie Street, Suite 208, Richmond Hill, ON L4B 3M4 / Holophane Europe Limited, Bond Ave., Milton Keynes MK1 1JG, England / Holophane, S.A. de C.V., Apartado Postal No. 986, Naucalpan de Juarez, 53000 Edo. de Mexico Contact your local Holophane factory sales representative for application assistance, and computer-aided design and cost studies. For information on other Holophane products and systems, call the Inside Sales Service Department at 740-345-9631. In Canada call 905-707- 5830 or fax 905-707-5695. Limited Warranty and Limitation of Liability Refer to the Holophane limited material warranty and limitation of liability on this product, which are published in the Terms and Conditions section of the current product digest, and is available from our local Holophane sales representative. Visit our web site at www.holophane.com