Adjustable Speaker Mount GRAVIS 12

Similar documents
Adjustable Speaker Mount GRAVIS 8

K&F Rotation Clamp 450

Translation of the Original operating instructions Lifting device Z 70 /...

JBL VTX-V20-DF SUSPENSION MANUAL

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Assembly and Maintenance Manual Type ASNU

TECHNICAL BULLETIN Suspension of Objects from Hall Ceilings A supplement to our Technical Regulations

Assembly and Maintenance Manual Type RSBW

Assembly and Maintenance Manual Type AS

Instructions for Use Plain Trolley ULK Geared Trolley UHK

HST -LS Interlocking device (Translation of Original Manual)

Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar

Compensation unit AGE-XY 50-80

Original Operating Manual

LOG CHOP. Hydraulic Wood Guillotine. Owners Illustrated Instruction Book & Parts List

Rotary feed-through DDF-S/-KS

Support T10552 T10595 T40386

Operating Instructions. TM Girder Clamps

Original Operating Manual

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Before equipment use, please read this operation manual carefully. Serial Number: Date Purchased:

Operating manual. Custom made gearboxes

ov-lifting_bolts_divider - Updated Lifting Bolts

MG12K24T60V4 Mechanical Grapple

A408 GB. Pneumatic oil and diesel pumps 1:1

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

CENTAFLEX-K Assembly and operating instructions 014K S... M EN Rev. 1

Mod: KLD6-12/35XLAS-N

CENTAX-TEST Assembly and operating instructions 053C GB3. M EN Rev. 1

BEAM CLAMP INSTRUCTION MANUAL

Original operating manual

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

HST-BL-2830MS & HST-BL-2830MS-USA

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

Installation manual wall-mounted distributor

MANUAL. Single charger

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Spare parts list Return line filter RFM with 2-hole attachment

Installation manual portable distributors

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

Turbocharger / TPS-H Original assembly instructions English

LOG SPLITTER. Heavy Duty PTO Driven. Owners Illustrated Instruction Book & Parts List

Component for OTC No or No. 1750A Engine Mounting Adapter

Product Information Overspeed governor GB 260

Swiveling gripper finger GFS 16-40

Operating Instructions Hoist Chains EN 818-7

Pneumatic grease pump 50:1 and grease supply system

ov-lifting_bolts_divider - Updated Lifting Bolts

User Guide AMF Floor / Portrait Adaptor

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar

TRACTION MRL LIFT ATLAS EU 2:1. Installation manual /39

Turbocharger / A100-L Original assembly instructions English

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Timing-Belt Reverse Unit 8 80 R25 Notes on Use and Installation

INSTRUCTION MANUAL. Pacific Self-locking Beam Trolleys Pacific Adjustable Angle Clamps Pacific Top Girder Clamps

Rotary couplings single, twin, four and six passages - without/with leakage oil port max. operating pressure 250 / 500 bar

KeContact P20. User manual

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

PRODUCT INFORMATION BOOKLET Document Reference: SPK_SUB_PIB_EN_1.3 Distribution Date: October 30th, SpekTrix Sub [ ]

OPERATIONS MANUAL LEVER CHAIN HOIST

LAH 500. Loudspeaker Mounting Hardware. Mounting instructions Montageanleitung Montageanleitung Montageanleitung Montageanleitung

Spare Parts List Filter NFD Change-Over Version

PE51 HURLEY 3 STATION METAL SWING SET OWNER'S MANUAL

CENTAFLEX-H Assembly and operating instructions 008H /3000 M EN Rev

Crane fork KGM/KGA and KGQ/KGL

DGMS (Tech.) Circular No. 10 Dated Dhanbad the 19 th July, Safe use of mobile Cranes Code of practice

PAGE 1 OF 5 HEALTH, SAFETY & ENVIRONMENTAL MANUAL PROCEDURE: S360 Overhead Cranes & Lifts Procedure REV 4.0 8/14/2012

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

CENTAX-SEC Series B Assembly and operating instructions CX BFS1-LE/SE-**-B M EN Rev. 1

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

Spare Parts List Return Line Filter RFM with 4-hole attachment

MS2200, MS2500, and MS3000 Suspension Installation Manual ON/OFF HIGHWAY SUSPENSION SYSTEM

Maintenance and Operating Instructions PG Style Pipe Grapple

OPERATING INSTRUCTIONS (Translation) Hoisting crane

Crane Forks. Introduction. Important Notes. Key Benefits. User Guide

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

PRODUCT INFORMATION BOOKLET Document Reference: SPK_T_PIB_EN_1.3 Distribution Date: October 30th, SpekTrix-t [ ]

Spare Parts List Return line filter RF

Operating Instructions

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

User Manual Hoof trimmingcrush:sa0010. Version: User manual. Hoof trimming crush SA0010

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Operating manual CLEANlift telescopic lifting column

TOOL BOX TALK - SAFE USE OF LIFTING EQUIPMENT

KSZ 10B Current Probe Calibrator. Instruction Manual

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Provided by: Operating, Maintenance & Parts Manual

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Inhalt. Granule jet blasting device PG 5 8. Owner s Manual. Translation of the original instructions

Owner s (Operator s) Manual & Safety Instructions Manually Lever Operated Chain Hoist Model LX1B

TM SERIES MIXER TMS OPERATION & PARTS MANUAL

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: )

IB-TPK Tight Pack Kit ibox Series Suspension Brackets

Mobile greasing system 27846

IMPORTANT SAFETY NOTICE

SCOPELITE TIMING LIGHT OPERATING MANUAL

Transcription:

Adjustable Speaker Mount GRAVIS 12 User's Manual Translation of the original instructions Version 3.3 Released: 19.01.2017 Important Information, Please Read Before Use! KLING & FREITAG GmbH Junkersstraße 14 D-30179 Hannover TEL +49 (0) 511 96 99 70 FAX +49 (0) 511 67 37 94 www.kling-freitag.de

Table of contents 1 Introduction 4 1.1 Icons Used 4 1.2 About these user's manual 4 2 Product Description 5 2.1 Intended Use 5 2.2 Items Included 5 2.3 Components 5 3 Safety Instructions 6 3.1 Mounting the Speakers / Wall and Ceiling Installation 6 3.2 Admissible load capacity 6 4 Installation and Usage Instructions 7 5 Dimensions and Weight 8 6 EC Declaration of Conformity 9 7 Accessories 10 8 Care and Maintenance 11 9 Transportation and Storage 11 10 Disposal 11 KLING & FREITAG GMBH 2017 Version 3.3 Page 3 of 12

1. Introduction Thank you for purchasing a KLING & FREITAG product. To guarantee trouble-free operation and enable the KLING & FREITAG GRAVIS 12 speaker system to achieve its full potential, please read these user's manual carefully before use. This item is a quality accessory for the GRAVIS 12 speaker system. Combining it with your existing speaker system creates an extremely versatile pro-grade tool that meets all requirements in terms of audio quality and safe installation. 1.1 Icons Used This icon indicates a risk of injury or death. Not following these instructions may result in serious health problems including potentially fatal injuries. Warning This icon indicates a possibly dangerous situation. Not following these instructions may cause minor injuries or damage. Caution This icon marks instructions for proper use of the described products. Not following these instructions may cause malfunctions or damage. This icon marks information provided for simplified use of the described products. Tip 1.2 About these user's manual KLING & FREITAG GMBH. All rights reserved. All specifications regarding the features of the described products and applicable safety guidelines provided in these user's manual are based on information available at the time of publishing. We assume no responsibility for technical specifications, dimensions, weights, and properties. All information in these user's manual is subject to change without notice. To ensure safe operation, all persons using the speaker accessories must have access to this guide and all other relevant material during installation. The speaker accessories must not be set up nor operated unless these user's manual has been read, understood and kept readily available on site. The original language of all KLING & FREITAG user's manuals is German. If you need user manuals from KLING & FREITAG, you can order a replacement or download it from our www.kling-freitag.de. Contact: info@kling-freitag.de KLING & FREITAG GMBH, Junkersstr. 14, D-30179 Hannover Telefon +49 (0) 511 96 99 70, Telefax +49 (0) 511 67 37 94 KLING & FREITAG GMBH 2017 Version 3.3 Page 4 of 12

2. Product Description 2.1 Intended Use The adjustable speaker mount GRAVIS 12 is solely for commercial use and may only be used with the loudspeaker GRAVIS 12 in the manner described here. Warning The may not be used to lift and secure people or objects other than the above-mentioned speaker systems. The Adjustable Speaker Mount GRAVIS 12 is protected from temporary climatic conditions. For long-term use, however, it is designed to be used indoors only. When used with the TV spigot 20 mm and the TV hook clamp, the Adjustable Speaker Mount GRAVIS 12 can be mounted on trusses or pipes with a diameter of 30 50 mm. With the M10 flange you can mount the Adjustable Speaker Mount GRAVIS 12 on a speaker stand or a distance rod. 2.2 Items Included Adjustable Speaker Mount GRAVIS 12 with captive metal clamp lever (1x) User's Manual 2.3 Components 1 2 3 4 5 1. Thread M10 2. Thread M8 3. Drill hole Ø 10.5 mm 4. Clamp lever 5. Rubber washer KLING & FREITAG GMBH 2017 Version 3.3 Page 5 of 12

3. Safety Instructions 3.1 Mounting the Speakers / Wall and Ceiling Installation Suspended loads pose a safety risk. Warning Only qualified technicians are permitted to perform the installation steps. Be sure to use personal protective equipment at all times. The technicians installing the speaker on site are responsible for and guarantee safe setup and use. Never use signal cables or power cords for suspending, aligning, or securing the systems. Before installing, check the stability, strength, and materials of walls, ceilings, and boarding. For example, use suitable rawlplugs for wall panels and make sure the strength is sufficient. Note that the suspension points on the hall ceiling (i.e. shackles, attachment points, or chain hoists) must comply with the DGUV regulations 17 and 18 or similar locally applicable accident-control standards. The maximum load must have been certified by an authorized expert. Be sure to tighten all bolts and screws to the specified torque. Unless otherwise stated, use only KLING & FREITAG original parts for mounting the speakers. Never use other parts (in particular, parts not made by KLING & FREITAG). Make sure all fittings used are suitable for the task at hand and meet all relevant safety requirements. Ensure that all connections are secured against coming loose and that only authorized, statically tested and correctly sized supports, mounting equipment, wire ropes and chains are used. Be sure to always visually inspect all safety-related speaker and accessory components before use. If there are signs of wear, cracks, or deformation, etc., replace the affected parts immediately. Visual inspection also includes checking all screwed connections of supporting components. The information described here does not relieve the user of the duty to follow the given safety requirements and legal regulations. 3.2 Admissible load capacity The speaker accessory Adjustable Speaker Mount GRAVIS 12 may only be loaded with one speaker model GRAVIS 12. Warning The speaker accessories may [...] mounted. KLING & FREITAG GMBH 2017 Version 3.3 Page 6 of 12

4. Installation and Usage Instructions 1. Pull the clamp lever outward. 2. As shown, position the clamp lever thread of the swivel arm above the M10 thread in the sides of the speakers and tighten the swivel arm slightly. 3. Adjust the speaker as desired. 4. Tighten the clamp lever. 5. Pull the clamp lever outward. Turn the clamp lever to a visually appealing position. KLING & FREITAG GMBH 2017 Version 3.3 Page 7 of 12

5. Dimensions and Weight Self-weight: 2.5 kg 383mm [15.079" ] 56 [2.205" ] 370,5 [14.587" ] 390,5 [15.374" ] 22 [0.866" ] 455 [17.913" ] 40 [1.575" ] 2 x M10 2 x M8 3 x Ø10,5 KLING & FREITAG GMBH 2017 Version 3.3 Page 8 of 12

6. EC Declaration of Conformity according to EC Machinery Directive 2006/42/EG We: KLING & FREITAG GmbH Junkersstrasse 14 30179 Hanover Germany hereby declare under our own responsibility that the following product(s): Type: Model(s): Mechanical speaker accessory Adjustable Speaker Mount GRAVIS 12 complies with the requirements of the EC health and safety directives. The following standards have been applied: DIN EN ISO 12 100 DIN EN 18 800 BGV C1 Hannover, January 5, 2016 Jürgen Freitag (CEO) KLING & FREITAG GMBH 2017 Version 3.3 Page 9 of 12

7. Accessories Stand socket M10 M10 x 17 Eyebolt Pipe Clamp for TV Spigot TV spigot 20 mm KLING & FREITAG GMBH 2017 Version 3.3 Page 10 of 12

8. Care and Maintenance 1. For the owner and user, it is mandatory to be aware that speaker accessories used to fly or mount the speakers are fundamentally safety-relevant. Warning Note that the mains cables are delivered with varying connector options or with open wires (mains side), depending on the country or order number. The accessory Adjustable Speaker Mount GRAVIS 12 can exhibit signs of wear over the years, i.e. from mechanical strain, transport damage, corrosion, or improper handling. As a basic principle, you must visually inspect the speaker accessory Adjustable Speaker Mount GRAVIS 12 before and after you use it. For fixed installations, you must inspect it for signs of wear at regular intervals. When performing those checks, particularly look for deformations, cracks, dents, damage to threads, and corrosion. Also check slings and lifts (e.g. shackles, chains, and steel ropes) carefully for wear and deformation. If as a result of these checks any uncertainty should arise with regard to safety or if specific faults are found, the Adjustable Speaker Mount GRAVIS 12 system may no longer be used and you must send in the product to KLING & FREITAG GmbH for inspection and repairs, if necessary. If defects are ascertained, then you must send in the product to KLING & FREITAG GmbH for inspection and repairs, if necessary. Inspection regulations may vary depending on application and country of use. Observe all applicable regulations; when in doubt, contact the local authorities. Many countries require regular inspection of mounting components and accessories. An additional annual inspection is typically required to be performed by a technical expert. Moreover, a legally certified or official authority must perform a detailed inspection every four years. Therefore, be sure to maintain an inspection log. Enter the values determined for each speaker and accessory during the periodic checks into this log. This way, relevant data are always at hand in case of inspection. The log should also document maintenance measures and inspection intervals and contain parts lists. 2. Clean this speaker accessory regularly using a corrosion-prevention penetrating oil (for example, WD-40 ). 9. Transportation and Storage The speaker accessory Adjustable Speaker Mount GRAVIS 12 is protected against short term moisture. Store, transport, and use the accessories in dry environments only. This speaker accessory is not designed for long-term use in a corrosive environment. Make sure that the system is adequately ventilated during longer storage periods so any residual moisture can escape from the equipment. Furthermore, you have to ensure that the accessory Adjustable Speaker Mount GRAVIS 12 is protected from mechanical strain to prevent possible damage. 10. Disposal Dispose of this product in compliance with your national regulations. Ensure that after being disposed of that this product cannot be used again or in any other way. KLING & FREITAG GMBH 2017 Version 3.3 Page 11 of 12

INDEX Accessories... 10 Care... 11 Components...5 Dimensions...8 Disposal... 11 EC Declaration of Conformity... 9 Intended Use... 5 Items Included... 5 Maintenance... 11 Mounting... 7 Power handling... 6 Product Description...5 Safety Instructions...6 Storage... 11 Transportation... 11 Weight...8 KLING & FREITAG GMBH 2017 Version 3.3 Page 12 of 12