Installation Instructions for the Powerslide RV Pedestal #

Similar documents
Installation Instructions for Lighthouse SS Power Pedestal Rev. 3 5/20/14

Installation Instructions for Admiral Power Pedestal (# )

! WARNING! WARNING. Dock Boxes Unlimited, Inc. strongly recommends that these products be installed by a qualified electrician.

Lighthouse Power Pedestals,

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Anchorage SS Center Model AN3050. Installation, Maintenance, and Operation Manual

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Beginner's Guide to Marinas, RV Parks, and NEC Requirements for Both

Bayside Model BU2050 Installation, Maintenance, and Operation Manual

Fire Station Hose Rack Model FSHR Installation, Maintenance, and Operation Manual

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Marina Mate SS Model MMSS2050. Installation, Maintenance, and Operation Manual

Marina Mate SS Model MMSS2050 Installation, Maintenance, and Operation Manual

Harbor Light SS Model HLSS Installation, Maintenance, and Operation Manual

Marina Power & Lighting Capabilities Brochure

Installation, Maintenance, and Operation Manual

GTX UNIT SUBSTATION Installation, Maintenance & Operation Manual

General Specifications for Lighthouse Power Pedestal

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate

Harbor Light Model HL General Specifications

6.2. Power Pedestals. Contents

5.2. Power Pedestals. Contents Description

320A Single Phase URD Meter Loop Installations

RV Park Equipment Product Focus. Power Pedestals Distribution Equipment

Installing or Rebuilding Your Electric Service

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2

6.1 Introduction Product Description... Application Description... Optional Features...

Installation Manual. Rev

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...

SPRINGVILLE CITY ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

Approved Contractor Construction e-guide Residential Commercial

Marina Power and Lighting Product Focus. Power Pedestals Distribution Equipment

ChargePro 620 Electric Vehicle Charging Station Installation Guide

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

UTILITY CROSSING DETAIL

Double Pole Circuit Breaker Kit for Non-Regenerative MinPak Plus DC Drives

Volume 1 Residential and Light Commercial CA E December

COMMERCIAL QUICK REFERENCE

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Marina Power and Lighting Equipment. Product Focus. Power Pedestals Distribution Equipment. High-Quality, Weatherproof Electrical Equipment

Pow-R-Line 3E Panelboard

Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series:

SALEM CITY POWER ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

Table of Contents. Electrical Service Requirements. 1. General Requirements

Joint Use Pedestals. alid AJP.

WSB clean: Installation Manual

Electric Vehicle Charging Station

ORDIC FIBERGLASS, INC.

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

SynergEX Panelboards for Hazardous Locations

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

ANZI Transfer Switch and Generator Wiring Installation Addendum

Sentinel Field Satellite Controller

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

Connector Installation Guide Compression and Mechanical Connectors

IM K IM K. Instructions for Cutler-Hammer Jockey Pump Controllers

Access Riser Fits PRO370 and PRO380 Series

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

PERMANENT RESIDENTIAL UNDERGROUND SERVICE

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

AIR CORE REACTORS. Phoenix Electric Corporation

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011

Contents. Volume 1 Residential and Light Commercial CA E December

7. Residential Single-Family and Duplex Buildings (Dwellings)

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

Electric underground service installation requirements

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

Water to Water Geothermal Heat Pump 3-Phase Models Both 208 & 480

GB2 35/50 GPM Grease Interceptor for Indoor Use

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

UNDERGROUND SERVICE. Items to consider. There will be charges from ComEd if you convert from overhead to underground service.

Galaxy VM. Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017.

CHAPTER 1 INTRODUCTION

5300 Series Installation Guidelines

Actsafe Safety Bulletin #23 WORKING WITH LIGHTING SYSTEMS AND OTHER ELECTRICAL EQUIPMENT

ZIP LIGHT LED LUMINAIRE

Remote Manifold Kit. Table of Contents: Important Information... 2 Product Contents... 3 Installation INSTALLATION INSTRUCTIONS

Lighting Control Unit Installation Instructions

#366. Gate Operator Pre-Installation and Site Planning. Introduction

For Conduit Inspections

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

Microinverters and AC PV modules are becoming. Microinverters and AC PV Modules. Different Beasts. Perspectives on PV.

PROPER ELECTRICAL CONNECTIONS

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

INSTALLATION GUIDE. Model #GB1 20/25 GPM Grease Interceptor For Indoor Use. Contents

NEC 2011 Code Changes

Cabinet and Rack Installation

Installation, Operation and Maintenance Manual

SECTION FUEL-OIL DISTRIBUTION (APPLIES TO FUEL TANKS FOR GENERATORS)

Owner's/Installation Manual

Owner s Manual. For Automatic Transfer Switch. 100 Amp. Model Number RTG16EZA3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

Transcription:

Installation Instructions for the Powerslide RV Pedestal #70-8760 Rev: 11/20/2017 Hazardous voltage. Can cause severe injury or death. Eaton Electrical Inc. strongly recommends that these products be installed by a qualified electrician. Turn off main power before opening panel. IMPORTANT - INSTALL EQUIPMENT IN CONFORMANCE WITH CODES This product must be installed in accordance with the National Electric Code (NEC) or the Canadian Electrical Code (CEC0 and any applicable local codes. Before installing equipment, check with your local electrical inspector for requirements and information. If you have questions or need assistance, contact a qualified electrician. Turn off or disconnect the power supplying this equipment before beginning work. This may require that you contact your electric utility to disconnect power to an existing load-center. The line side of the main breaker is energized unless power is disconnected upstream. Eaton Electrical, Inc. will not assume responsibility for property damage or personal injury resulting frommisuse of the information in this publication.

Powerslide RV Pedestal Wiring Diagram Installation Note We strongly recommend that a qualified electrical contractor install this unit. Copper wire and clean the wire, coat the wire with an anticorrosion grease, and retighten the assembly. Three methods to choose from: ON CONCRETE PAD-PAD MOUNT BASE Utilize the Pad Mount mounting base, as shown in drawing above, pad mount bracket mounts to inside of lower portion of pedestal. 1. Remove (2) screws from lower access cover and slide cover down to release from top retaining bracket. 2. Remove lower pedestal cover by removing (4) screws. Pull cover away from post. 3. Assemble pad mount base to inside of lower portion of pedestal utilizing (9) screws provided. 4. Pad mount bracket is provided with six 3/8" diameter holes for mounting to concrete using compression bolts or threaded rod set in the concrete. DIRECT BURY - PEDESTAL EXTENSION Utilize the in ground pedestal extension, as shown in drawing above, in ground pedestal extension mounts to inside of lower portion of pedestal. 1. Remove (2) screws from lower access cover and slide cover down to release from top retaining bracket. 2. Remove lower pedestal cover by removing (4) screws. Pull cover away from post. 3. Assemble direct burial pedestal extension to inside of lower portion of pedestal utilizing (9) screws provided. 4. Insure that post is positioned properly. Bottom of post should be 24" below grade level. 5. Lay wires in and attach to proper terminals. Refer to publication on panel cover for torque and wire size information. 6. Replace lower pedestal cover and secure with (4) screws. 7. Replace upper pedestal cover and secure with (2) screws. To padlock lower access cover utilize clip-on hasp provided. 8. To increase stability, mounting in concrete at or below grade level marking is recommended. POST MOUNT -4 X 4 INTERNAL POST 1. Position pedestal in location of install, mark center of pedestal location. 2. Dig hole to allow post to be below frost line of area installed, typically 24" or deeper, consult local codes to insure compliance. 3. Install post and cement inplace, back fill with soil. 4. Once cementi set remove soil below in forward facing area of pedestal for incoming conductors to be routed from wire trench. 5. slide pedestal over post, post should be no longer than 12" above grade. 6. Affix pedestal to post utilizing (4) 1/4-20 screws into post. Parts Save 10% When You Buy Parts and Pedestals Online! Please visit www.marinapower.com for a full parts listing. To request a parts handbook: Call 1-800-723-8009 E-mail marinaparts@eaton.com Eaton Corporation Marina Power and Lighting 149 Warwick Court Williamsburg, VA 23185 United States tel: 1-800-723-8009 fax: 757-258-8805 www.marinapower.com www.marinapower.com 1-800-723-8009 Installation Guide #70-8760 POWERSLIDE RV PEDESTAL 1

Pad Mount Single Dual www.marinapower.com 1-800-723-8009 Installation Guide #70-8760 P OW E R S LID E R V P E D E S TA L 2

Burial Mount Single 39.66 Fasten direct burial to pedestal 8.67 3.87 23.98 Dual www.marinapower.com 1-800-723-8009 Installation Guide #70-8760 P OW E R S LID E R V P E D E S TA L 3

Post Mount Single 39.66 1.50 4.75 Fasten post to pedestal 8.67 4.59.58 3.50 23.00 Dual www.marinapower.com 1-800-723-8009 Installation Guide #70-8760 P OW E R S LID E R V P E D E S TA L 4

Water Assembly 3/4 RAVEN BALL VALVE COMMUNICATION ASSEMBLIES COMMUNICATION ASSEMBLIES INCLUDE ISOLATION BOXES FOR INTERNAL CONNECTIONS. WEATHERPROOF COVER INTERNET T.V. PHONE T.V. www.marinapower.com 1-800-723-8009 Installation Guide #70-8760 POWERSLIDE RV PEDESTAL 5