Blade Features. AirShield Control and Shut Off Dampers. AirShield

Similar documents
Actionair Control and Shut Off Dampers

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

IrisControlDamper. For Adjustment and Measuring of Airflow.

Cell Ventilation Security Grille

Anti-Ligature Grille. There s a much bigger picture to be found at Ruskin Air Management. Model AL/35 Model AL/24. range available.

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

CONTROL SMOKE AND BALANCING DAMPERS

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

Panel Floor Grilles Model LDA, MDA, HDA, PFS and F48

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers.

Floor Swirls Models BZD and SZD

Actionair Smoke/Shield PTC

Linear Floor Grilles Models FG, F20, F25 and FRO

NEW. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.

FlowBar High Capacity Slot Diffuser

VOLUME CONTROL / REGULATING DAMPERS

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

Fire Block and Pressed Steel Grilles

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

SFD-EN Smoke/Fire Dampers

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

INDEX. Chapter1 6. air master. Volume Control Dampers

Series HCD Airfoil Control Damper

Catalogue. FlowBar. High Capacity Slot Diffuser.

Fire & Gas Dampers. Fire & Gas Dampers are used in ventilation systems to prevent the spread of flame and/or smoke between divisions.

Fire Block and Pressed Steel Grilles

Specification. Introduction. A-60 Marine Fire Damper

Catef Marine-Fire. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

HotShield PTC TM. High Operating Temperature Smoke Management and Fire Dampers. Features

MOTORIZED VOLUME DAMPER

Linear Slot Diffusers Model Slot 20 and Model Slot 25

Catalogue. HotShieldPTC TM. High Operating Temperature Smoke Management and Fire Dampers.

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

A-60 Marine Fire Damper

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

BD Series. Backdraught Volume Regulating Damper M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide

SERIES C. Adjustable Deflection Grilles for Circular Ducting

Multileaf damper with actuator

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

Perforated Face Ceiling Diffusers

Ceiling swirl diffusers

Zero Leakage Isolation Damper

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Marine Fire and Gas Dampers

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Variable Air Volume Dampers

PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper

FD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

SSV Smoke Shaft Ventilation System

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Zest Iris Duct Dampers

Grilles & Diffusers. Series NV Non-vision grilles. Incorporating. Sight blocking design ensures privacy is maintained

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

VCD-23. Flange Options. Size Limitations

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Ceiling swirl diffusers

SDV Vane Swirl Diffusers

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

AL-Maraj Central A/C Systems Accessories Mfg Co.

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

HCD-230 Industrial Control Damper

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

For installation into ductwork

HOTCHKISS AIR ACOUSTICS

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

Butterfly valves, PN6, PN10, PN16

VCD-23 Low Leakage CONTROL DAMPER

VCD-23. Low Leakage CONTROL DAMPER

HIGH CAPACITY LINEAR SLOT DUFFUSERS

VAV TERMINAL BOXES TYPE: BA BT

LINEAR SLOT DUFFUSERS

Model VCD-43 Extruded Airfoil Blade Control Damper

Ceiling swirl diffusers with perforated face plate

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Fire Damper. Grilles Diffusers Dampers Louvers VAV Boxes Sound Attenuators. Spectrum Industries

Butterfly valves PN6, PN10, PN16

LINEAR SLOT DIFFUSERS

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

TABBED ACCESS DOOR RANGE

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

Transcription:

April 2011 AirShield AirShield AirShield Aerofoil Air Control Dampers AirShield Aeroseal Air Control and Shut Off Dampers AirShield Features and Design Guide Opposed blade dampers suitable for systems requiring air control (Aerofoil) and low closed blade leakage (Aeroseal). Suitable for low/medium pressure and velocity systems. Available in flanged type casing up to 1000mm square or spigotted type casings up to 1000mm square/1000mm diameter or flat oval up to 1000mm x 550mm in a single drive arrangement. Dampers Designed and Built in Britain (Rev 1.) Dampers Controls Fancoils Ruskin Air Management Limited www.ruskinuk.co.uk

AirShield Control and Shut Off Dampers The Range The AirShield range of quality engineered dampers are suitable for air conditioning and ventilation systems requiring air control and low closed blade leakage characteristics. For standard low/medium pressure and velocity systems. These aerodynamic precise movement opposed blade dampers can be either factory fitted with manual, electric or pneumatic controls and can be supplied in a flanged or spigotted casing. (Motorised option on Aeroseal only) Application Parameters AirShield Dampers to maximum width and height dimensions (see page 4) can be used where the operating total system pressure is up to 1000 Pascals and duct velocities to 12m/second. Actionair AirShield Dampers are designed for applications in normal dry filtered air systems. When required for modulating function, or if exposed to fresh air intakes and/or inclement conditions, the dampers should be subject to a planned inspection programme. Any application involving corrosive and/or aggressive hostile environmental conditions (e.g. swimming pools) may invalidate our warranty and should be referred to Actionair Sales Office. Aerofoil Air Control Damper Blade Features Aeroseal Air Control and Shut Off Damper Series Aerofoil Series Aerofoil for system air balancing having aerodynamic ribbed double skin type 1.4016 (430) Ferritic Stainless Steel 50mm wide x 0.4mm thick blades. Housed within a galvanised mild steel flanged or galvanised spigotted casing being suitable for systems with a temperature range of 20 C through to +70 C. Series Aeroseal Series Aeroseal for system air balancing and shut off having aerodynamic double skin type 1.4016 (430) Ferritic Stainless Steel 50mm wide x 0.4mm thick blades with synthetic trailing edge blade seals and Stainless Steel side seals. Housed within a galvanised mild steel flanged or galvanised spigotted casing being suitable for systems with a temperature range of 0 C through to +70 C. Optional Blade construction type 1.4401 (316) Austenitic Stainless Steel. Blade Drive Mechanism The totally enclosed, precise movement, opposed blade cap and bar drive mechanism positioned out of the airstream for protection against damage is hard wearing and free running. 2 www.actionair.co.uk

Casing Features Weights The damper casing having a single penetration for the drive control shaft making these dampers suitable for inclusion into air distribution systems of Class A and B of Eurovent Document 2/2 and Test Procedures for Classes A, B, and C (up to 1000 Pa) of HVCA Ductwork Specification DW144. Flanged A 1.5mm thick galvanised mild steel casing having peripheral flanges with pre punched elongated corner holes to suit proprietary duct flanges. Stainless Steel Options See Dimensional Data and refer to Actionair Sales Office Available on Aeroseal only. Spigotted Consists of Flanged Casing above with 0.9mm minimum thickness spigots on both sides. Stainless Steel Options See Dimensional Data and refer to Actionair Sales Office Available on Aeroseal only. Please Note: AirShield, Aerofoil and Aeroseal dampers are only available in widths and heights up to 1000mm, please refer to page 4 for full sizing parameters. Multiple Assemblies Type FLA Square/Rectangular Type SPG Square/Rectangular Type SPG Circular AirShield Aerofoil and Aeroseal Approximate Weights (Kg) SQUARE/ TYPE FLA TYPE SPG TYPE SPG CIRCULAR RECT. RECT. CIRCULAR DUCT SIZE 100 1.5 1.8 2.1 150 2.0 2.4 2.9 200 2.5 3.1 3.8 250 3.1 3.8 4.7 300 3.8 4.6 5.8 350 4.5 5.4 6.9 400 5.2 6.3 8.0 450 5.8 7.0 9.0 500 6.6 7.9 10.3 550 7.5 9.0 11.6 600 8.4 10.0 13.0 2060mm 650 9.3 11.0 14.4 700 10.0 11.9 15.7 1000mm Type SPG Flat Oval 750 11.3 13.3 17.5 800 12.4 14.5 19.2 For flanged damper arrangements with dimensions in excess of 1000mm wide, the ES35 or ES36 will always be offered, (please refer to the Actionair brochure ES Heavy Duty Air Control and Shut off Dampers). However, should individual AirShield dampers be preferred (due to damper depth limitations etc.), i.e. arranged side by side having 2 drives, ensuring that adequate space is allowed for access / fitting to each drive arrangement. They can be supplied up to 2060mm wide, by specific written instruction from customer at the time of Enquiry / Quotation / Order only. Please note: Aerofoil and Aeroseal dampers must not be installed with blades running vertical. 850 13.3 15.6 20.7 900 14.7 17.1 22.7 950 15.7 18.2 24.3 1000 16.8 19.4 26.1 For Type SPG Flat Oval weights please contact Actionair Sales Office. www.actionair.co.uk 3

Dimensions Sizing Parameters Type FLA Widths from 100 1000mm in 1mm Heights from 100 1000mm in 50mm Type SPG Rectangular Widths from 100 1000mm in 1mm Heights from 100 1000mm in 1mm Type SPG Circular Diameters from 100 1000mm in 1mm Type SPG Flat Oval Widths from 300 1000mm in 1mm Heights from 100 550mm in 1mm Stainless Steel Options Size Parameters as above. Stainless Steel Type FLA Damper casings will have a depth of 150mm with 40mm peripheral flanges (Please refer to Actionair Sales Office). 150 20 16 20 16 13 Dia 8 8 40 4 www.actionair.co.uk

Control Options Manual Control (Option M) Always fitted as standard on Series Aerofoil units. Not suitable for Series Aeroseal or any Stainless Steel options. Consists of a red knob and slimline control box with blade position locking facility (a no. 6 pk screw supplied and fitted by others pierces through membrane in the control box) and visual blade position indication. Type FLA/SPG 5 34 98 65 Technical Data (Aeroseal only) Pneumatic Controls (Option E) Factory fitted Hytork Pneumatic Actuators are available in on/off and spring return versions. Factory fitted Controls will be selected to suit the torque requirements of the dampers. Please refer to Actionair Sales Office if you require any further information. Manual Quadrant Control (Option Q) (Aeroseal only) Electrical Controls (Option E) Factory fitted Belimo Actuators for 24V or Type Type SPG 230V open/closed or spring return FLA/SPG Stainless Steel operation and 24V modulating are 150 available. These will comply with EMC Consists of a dark Directive 2004/108/EC. brown steel handle, blade position locking facility and quadrant bracket with visual position indication. 6 16 5 Nm LM A 10 Nm NM A 31 100 25 62 183 47 Extended Shaft Control (Option X) (Aeroseal only) 20 Nm SM A 10Nm NF Type FLA/SPG Type SPG Stainless Steel A solid 12.7mm diameter stainless steel shaft marked to provide visual blade indication complete with support bracket for attachment of couplings and/or linkages for motorisation by others. (Shaft rotates clockwise to close damper). 12.7 DIA 127 27 58 OPEN CLOSED 60 16 43 12.7 DIA 143 20Nm SF www.actionair.co.uk 5

Specification AirShield Aerofoil Air control and system balancing dampers comprising of 50mm ribbed stainless steel aerodynamic blades with synthetic blade end bearings. Housed in either a galvanised mild steel frame having integral peripheral flanges, with prepunched corner holes to suit proprietary duct flanges (Type FLA) or with spigot plates on both Technical Data Pressure Drop Vs Velocity Positions 1, 2 and 3 are blade positions as indicated on dampers fitted with Manual Control or Manual Quadrant Control. PRESSURE DROP (Pa) 1000 900 800 700 600 500 400 300 200 100 90 80 70 60 50 40 30 20 10 9 8 7 6 5 4 3 2 1 SERIES AEROFOIL SERIES AEROSEAL EXAMPLE LINE 1 2 1/4 OPEN (POSITION 3) 1/2 OPEN (POSITION 2) 3/4 OPEN (POSITION 1) 1/4 OPEN (POSITION 3) 1/2 (POSITION 2) 3/4 OPEN (POSITION 1) FULLY OPEN FULLY OPEN sides, for square, rectangular, circular or flat oval connections (Type SPG). The totally enclosed precise movement opposed blade mechanism positioned out of the airstream for protection against damage is hard wearing and free running. AirShield Aerofoil as supplied by Actionair. Aeroseal Damper Leakage AirShield Series Aeroseal closed blade leakage 1000mm wide x 1000mm high Damper. PRESSURE DIFFERENTIAL ACROSS CLOSED DAMPER (Pa) 1000 500 300 250 200 150 120 AirShield Aeroseal Air control and system balancing shut off dampers comprising of 50mm stainless steel aerodynamic blades with synthetic trailing edge blade seals, synthetic blade end bearings and stainless steel top and side spring tempered flexible gasketing. Dampers to have a maximum closed blade leakage of 27 l/s at 1000 Pa when measured on a 1000mm wide x 1000mm high damper. Housed in either a galvanised mild steel frame having integral peripheral flanges, with prepunched corner holes to suit proprietary duct flanges (Type FLA) or with spigot plates on both sides, for square, rectangular, circular or flat oval connections (Type SPG). The totally enclosed precise movement opposed blade drive mechanism positioned out of the airstream for protection against damage is hard wearing and free running. AirShield Aeroseal as supplied by Actionair. AirShield Aerofoil dampers are supplied fitted as standard with type Manual Control (Option M). Aeroseal dampers are supplied fitted as standard with type Manual Quadrant Control (Option Q). Aeroseal Stainless Steel dampers are supplied with type Manual Quadrant Control (Option Q) fitted as standard. AirShield dampers can be factory fitted with one of the alternative control options as detailed on page 5 (Aeroseal and Stainless Steel dampers not suitable for Option M). Maintenance 100 The Actionair range of AirShield Dampers are designed for applications in normal dry filtered air systems and should be subjected to a planned inspection 70 programme, with cleaning and light oil lubrication in accordance with good industry practice. When exposed to fresh air intakes and/or inclement conditions 50 this may need to be performed more 3 4 5 6 7 8 9 10 12 1 2 3 4 5 6 78910 15 2025 30 regularly based on experience gained DUCT VELOCITY (m/s) LEAKAGE (I/s) from previous inspections. 6 www.actionair.co.uk

Selection Please refer to individual sections of the brochure for specific product detailed information. Aerofoil Aeroseal Flanged Casing Minimum 100 x 100 (Height increments of 50mm) Flanged Casing Maximum 1000 x 1000 30mm Flange Galvanised. 40mm Flange Stainless Steel Flanged Casing Depth 65mm Galvanised. 150mm Stainless Steel Spigotted Casing Minimum 100 x 100, Maximum 1000 x 1000 Circular Option Minimum 100 diameter, Maximum 1000 diameter Flat Oval Option Minimum 300 x 100, Maximum 1000 x 550 Air Balancing Shut off Function Opposed Blade Movement Manual Control Option M (Standard for Aerofoil) N/A (Not Stainless Steel) Manual Quadrant Control Option Q (Standard for Aeroseal) Extended Spindle Control Electrical Control (Optional) Blade Drive Mechanism mounted out of the airstream Casing Leakage Conforms to DW144 Class C up to 1000Pa Galvanised Case with 430 Stainless Steel Blades (Standard) Stainless Steel Options 430 and 316 available (Aeroseal only) N/A N/A N/A N/A Electrical Controls (Option E) Area m 2 Dia mm Open/Close or Modulating Spring Return RECTANGULAR / FLOV CIRCULAR 5 Nm LM A 10 Nm NM A 20 Nm SM A 10Nm NF 20Nm SF Airshield Aeroseal Up to 0.09 M 2 Up to 300mm Dia Up to 0.10 M 2 Up to 315mm Dia Up to 0.30 M 2 Up to 550mm Dia Above 0.30 M 2 Above 550mm Dia Due to a policy of continuous product development the specification and details contained herein are subject to alteration without prior notice. www.actionair.co.uk 7

Ordering Information Example Quantity Series Type Control Option Duct Size 10 AirShield Aeroseal FLA Q 800 (W) x 400 (H) Number Required AirShield Aerofoil or AirShield Aeroseal FLA Flanged Casing SPG Spigotted Casing, in Rectangular, Circular or Flat Oval Configuration. M Q Manual Control (fitted as standard to Series AirShield Aerofoil). Manual Quadrant Control (always fitted as standard to Series AirShield Aeroseal and Stainless Steel options). E Electrical Operator (Aeroseal only) 24V or 230V open/closed 24V or 230V spring return or 24V modulating. X Extended Shaft Control (Aeroseal only) Ruskin Air Management Limited is a ISO 9001 and 14001 registered company The statements made in this brochure or by our representatives in consequence of any enquiries arising out of this document are given for information purposes only. They are not intended to have any legal effect and the company is not to be regarded as bound thereby. The company will only accept obligations which are expressly negotiated for and agreed and incorporated into a written agreement made with its customers. Due to a policy of continuous product development the specification and details contained herein are subject to alteration without prior notice. Pneumatic Actuator Double acting. Spring Return. Ruskin Air Management Limited South Street, Whitstable, Kent CT5 3DU England. Tel: 01227 276100 Fax: 01227 264262 Email: sales@actionair.co.uk Website: www.actionair.co.uk PRODUCED BY www.geoffstrange.co.uk