EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

Similar documents
Blade Features. AirShield Control and Shut Off Dampers. AirShield

Actionair Control and Shut Off Dampers

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

IrisControlDamper. For Adjustment and Measuring of Airflow.

Cell Ventilation Security Grille

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

Panel Floor Grilles Model LDA, MDA, HDA, PFS and F48

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

Anti-Ligature Grille. There s a much bigger picture to be found at Ruskin Air Management. Model AL/35 Model AL/24. range available.

Linear Floor Grilles Models FG, F20, F25 and FRO

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

Series HCD Airfoil Control Damper

CONTROL SMOKE AND BALANCING DAMPERS

Floor Swirls Models BZD and SZD

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers.

FlowBar High Capacity Slot Diffuser

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

VOLUME CONTROL / REGULATING DAMPERS

Fire Block and Pressed Steel Grilles

INDEX. Chapter1 6. air master. Volume Control Dampers

Fire Block and Pressed Steel Grilles

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

Catalogue. FlowBar. High Capacity Slot Diffuser.

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

NEW. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.

Linear Slot Diffusers Model Slot 20 and Model Slot 25

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

BD-1600 Balancing/Zone Control Damper

Actionair Smoke/Shield PTC

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

Zero Leakage Isolation Damper

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

MOTORIZED VOLUME DAMPER

Multileaf damper with actuator

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

SFD-EN Smoke/Fire Dampers

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Fire & Gas Dampers. Fire & Gas Dampers are used in ventilation systems to prevent the spread of flame and/or smoke between divisions.

FSD60/MFSD60 Multi-blade Fire Damper

For installation into ductwork

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Marine Fire and Gas Dampers

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

BD Series. Backdraught Volume Regulating Damper M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

VCD-23. Flange Options. Size Limitations

HIGH CAPACITY LINEAR SLOT DUFFUSERS

Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

Perforated Face Ceiling Diffusers

SMOKE DAMPER - CLASS F MODEL BMSD

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

LINEAR SLOT DIFFUSERS

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

VCD-23 Low Leakage CONTROL DAMPER

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Ceiling swirl diffusers

VD-1600 Series Volume Control Dampers

HotShield PTC TM. High Operating Temperature Smoke Management and Fire Dampers. Features

LINEAR SLOT DUFFUSERS

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

ID-141x 12-Gauge Hat Channel Industrial Damper

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

Catef Marine-Fire. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

L O U V E R S & D A M P E R S

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

CFSD Series. Product Description

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

When Time is Everything... We Manufacture in Days - Not Weeks!

Type NAK. Gas-tight shut-off damper with pneumatic actuator

HCD-230 Industrial Control Damper

Fan - Powered Terminal Unit Series Flow

FD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide.

VARYCONTROL VAV Dual Duct Terminal Boxes

VCD-23. Low Leakage CONTROL DAMPER

Specification. Introduction. A-60 Marine Fire Damper

VAV TERMINAL BOXES TYPE: BA BT

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Transcription:

April 11 EnergyShield ES EnergyShield ES Air Control and Shut off Dampers Features Dampers suitable for systems requiring air control and low closed blade leakage characteristics. Low torque characteristics. Rectangular versions available in Flanged or Spigotted type casings. Circular and Flat Oval versions available in Spigotted casings. Blades completely within casing. Standard opposed blade movement. Optional parallel blade movement. Product Range ES35 Air control and system balancing ES36 Air control, system balancing and low closed blade leakage to EN1751 class 2*. ES50 Aerofoil bladed, galvanised casing for air control, system balancing and low closed blade leakage to EN1751 class 3*. *Based on a 1m x 1m damper. Dampers built in the UK. Dampers Controls Fancoils Ruskin Air Management Limited www.ruskinuk.co.uk

Application Parameters The ES range of dampers are suitable for air conditioning and ventilation systems requiring air control and low closed blade leakage performance. Blade construction for system pressures up to 0Pa and duct velocities of up to 10m/s on the ES35 and ES36 range and 1500Pa, and m/s on the ES50 range. Suitable for applications in normal dry filtered air systems, including modulation function. If exposed to fresh air intakes, and/or inclement conditions, the 316 stainless steel option should be considered by the client (ES35 + 36). All installations should be subject to a planned inspection programme, frequency of which is dependant upon application and environmental conditions. For specialist applications and products outside specified parameters, please consult with our Technical Sales Office. Please note: ES dampers must not be installed with blades running vertical. Blade Features EnergyShield ES ES35 1.5mm thick triple Vee groove blade profile, to give maximum strength. Suitable for systems with an operational temperature range of C to +70 C. ES35 C280: (no blade seal sealant), suitable for 280 C continuous operation. Standard: Galvanised steel. Optional: 316 stainless steel. ES36 1.5mm thick triple Vee groove blade profile, to give maximum strength. With additional blade seals attached within blade Vee groove to create low closed blade leakage. Suitable for systems with an operational temperature range of 180 C. continuous operation. ES36 C180: silicon blade seal, suitable for 280 C continuous operation. Standard: Galvanised steel. Optional: 316 Stainless steel. ES50 Profiled aerodynamic aluminium extrusion for low noise generation. Blade tip seals to give very low closed blade leakage. Suitable for systems with an operational temperature range of C to +70 C (+70 C only standard blade seal). Casing and Drive Features All damper blades are within the casing Total depth over spigots ES50 which significantly reduces air I.e. they do not protrude beyond the Type SPG (square/rectangular) = 254mm leakage between the blade ends, and the casing depth. This ensures blades will not Type SPG (circular (CIRC) and flat oval internal sides of the damper casing. foul equipment (such as grilles or louvres) (FLOV) = 304mm that may be fitted adjacent to the damper. This feature also allows easy fitting and Blade Drive Mechanism removal of the Flanged damper (FLA). For all ES Dampers, the damper casing The blade drive mechanism is mounted The 165mm wide FLA casing consists of leakage conforms to HVCA Ductwork out of the airstream to minimise pressure a single skin 1.2mm steel frame with Specification DW144 class A,B and class and noise generation, blade axles are mm flanges and pre punched corner C. Optional DW144 class C leakage 11.1mm hexagonal zinc plated steel. holes to suit proprietary duct flanges. available. Requires additional side cover Synthetic blade bearings give a corrosion The Spigot (SPG) type casings are 178mm plates. resistant, hard wearing and free running wide that include spigotted end caps fitted 301 grade stainless steel side gasketting operation. to either side of the FLA casing. is fitted as standard to series ES36, and Type FLA Square/Rectangular Type SPG Square/Rectangular Type SPG Circular Type SPG Flat Oval 2 www.actionair.co.uk

Size Range Dimensions Type FLA and Type SPG (Rectangular) Single section Widths in any size from 0mm to 10mm. Heights in any height from 0mm to 1800mm (SPG: 1700mm) in increments of 1mm. Double section 1. Single drive with hexagon coupling Widths in any size from 11mm to 80mm. Heights in any height from 0mm to 1800mm (SPG: 1700mm) in increments of 1mm (ES35). Heights in any height from 0mm to 0mm in increments of 1mm (ES36/ES50). 2. Single Drive with jackshaft (ES35/ES36, GALV, FLA) Widths in any size from 11mm to 2480mm. Flanged Casing (Type FLA). Single Drive (no mullion) Height 0 mm - 1800 mm in 1mm increments Width 0mm - 10mm in 1mm increments Drive 165 7 7 OVERALL DAMPER HEIGHT (= DUCT HEIGHT + 80mm) Spigot Casing (Type SPG Rectanglar) SPG rectangular spigots are supplied 5mm under duct size. DUCT WIDTH 38 Heights in any height from 350mm to 5mm 1800mm in increments of 1mm. Spigot Casing (Type SPG Circular) 3. Drive both sides SPG circular spigots are supplied 3mm under duct size. 178 Widths in any size from 11mm to 2480mm. Heights in any height from 0mm to 1800mm (SPG: 1700mm) in increments of 1mm. Type CIRC Diameters in any size from 0mm to 0mm. Type Flat Oval Single section Widths in any size from 300mm to 10mm. Double section Widths in any size from 11mm to 00mm. Single or double section Heights in any size from 0mm to 550mm. DUCT HEIGHT 5mm DUCT 63 DIAMETER 3mm Spigot Casing (Type SPG Flat Oval) SPG flat oval spigots are supplied 3mm under duct size. 178 DUCT HEIGHT 3mm 27.5 17.5 17.5 27.5 178 12 Dia 38 63 Double section arrangement Heights up to and including 0mm, supplied factory assembled Heights above 0mm, supplied individually with joining strips for site assembly, by others. Additional note for multiple Type SPG (Rectangular) Spigots attached to individual single DUCT WIDTH 3mm Alternative casing depths (FLA) in mm, 1, 150, 160 Blades will protrude outside casing. 165 default standard. section dampers. On site provision of filling gaps between spigot and duct 175, 0, 250. where dampers join required by others. Note: and 1 not available with side covers or jack shaft. 63 63 www.actionair.co.uk 3

Standard Extended Spindle ES35, ES36 and 50, Extended Spindle and Hexagon Drive Arrangements 0-10 1.mm JOINING STRIP (BOTH SIDES) 11-80 0-0 80 0-0 0-1800 (35) 0-0 (36/50) HEX COUPLINGS Standard section single unit Two sections unit with Hex coupling (single drive) 11-2480 81-3160 0-0 80 0-0 80 0-0 0-1800 (35) 0-0 (36/50) HEX COUPLINGS 1.mm JOINING STRIP (BOTH SIDES) Two sections unit (drive both sides) Three sections unit with Hex coupling (drive both sides) Jack Shaft External Drive Arrangements Galvanised Flanged Only ES35, ES36 Single Damper, External Drive ES35, ES36 Multiple Small Dampers, External Drive 1.mm JOINING STRIP (BOTH SIDES) 110 110 0-600 0-600 0-600 Single section unit with jackshaft external drive Two sections unit with jackshaft external drive ES35, ES36 Multiple Large Dampers, External Drive ES35, ES36, External Drive Jack Shaft arrangement 1.2mm JOINING STRIP (BOTH SIDES) 2481-3760 0-10 80 0-10 80 0-10 110 JACKSHAFT 600-10 600-600 1.mm JOINING STRIP (BOTH SIDES) Two sections unit with jackshaft external drive (single drive) Three sections unit with jackshaft external drive (drive both sides) 4 www.actionair.co.uk

Jack Shaft Internal Drive Arrangements Galvanised Flanged Only ES35, ES36 Single Damper, Inboard Drive ES35, ES36 Multiple Small Dampers, Inboard Drive 1.2mm JOINING STRIP (BOTH SIDES) 335 to 1800 335 to 1800 0 to 600 0 to 600 0 to 600 Single section unit with jackshaft inboard drive Two sections unit with jackshaft inboard drive ES35, ES36 Multiple Large Dampers, Inboard drive ES35, ES36, Inboard Drive Jack Shaft Arrangement 11-2480 0-10 80 0-10 2481-3760 0-10 80 0-10 80 0-10 JACKSHAFT JACKSHAFT 1.mm JOINING STRIP (BOTH SIDES) 1.mm JOINING STRIP (BOTH SIDES) Two sections unit with jackshaft inboard drive (single drive) Three sections unit with jackshaft inboard drive (drive both sides) Face and Bypass Jack Shaft External Drive Arrangement ES35, ES36 Face and Bypass Small Dampers, External Drive ES35, ES36 Face and Bypass Large Dampers, External Drive 601-1280 11-2480 110 335 to 1800 110 0-600 0-600 601-10 601-10 1.2mm JOINING STRIP (BOTH SIDES) 1.2mm JOINING STRIP (BOTH SIDES) Note: Face and bypass available for all multiple arrangements www.actionair.co.uk 5

Control Options Extended Shaft Control (Option X) 12.7mm diameter Zinc plated steel Extended Spindle for motorised control. Supplied as standard, loose for site fitting by others. FLA Type Casing SPG Type Casing Ø 12.7 Ø 12.7 126 165 126 178 188 Casing Leakage Options Note: Class C casings have spindle factory fitted. Exposed Linkage Class B Casing leakage. Side covers for Class C Casing leakage. Class C Casings have spindle factory fitted. Manual Quadrant Control (Option Q) Manual Quadrant Control, fits onto a reduced shaft and is supplied factory fitted. 41 135 32 145 Class C Casings have spindle factory fitted. 6 www.actionair.co.uk

Electrical Controls (Option E) Weights Factory fitted Belimo Actuators for 24V or 230V open/closed or spring return operation and 24V modulating are available. These will comply with EMC Directive 04/108/EC. FLA Damper Weight Table ES35 base product (Kg) Height Width 0 0 600 800 0 10 0 3.8 5.4 7.0 8.6 10.2 11.8 0 6.0 8.3 10.6 12.9 15.1 17.4 600 7.8 10.6 13.4 16.3 19.1 21.9 800 9.5 12.9 16.3 19.7 23.1 26.5 0 11.4 15.3 19.1 23.0 26.9 30.7 5 Nm LM A 10 Nm NM A 10 13.2 17.7 22.1 26.6 31.0 35.5 10 15.1.3 25.5 30.6 35.8 41.0 1600 17.0 22.8 28.5 34.2 39.9 45.6 1800 18.7 25.0 31.2 37.4 43.6 49.9 CIRC Damper Weight Table ES35 (Kg) 0 dia 5.4 0 dia 11.7 600 dia 19.0 Nm SM A Nm GM 800 dia 27.5 0 dia 37.3 Multipliers for alternative configurations (select nearest size up from chart and use multiplier below). ES36 multiply by 1.1 ES50 multiply by 0.91 Example: 600 x 0 ES36 19.1 x 1.1 = 21.01 Kg approx. 10Nm NF Nm SF www.actionair.co.uk 7

Selection Electrical Controls (Option E) Single Section Double Section Dia mm Open/Close or Modulating Spring Return 300 C 1 Hour with Hex drive arrangement* RECTANGULAR/FLOV CIRCULAR 5 Nm LM A 10 Nm NM A Nm SM A Nm GM A 10 Nm NF Nm SF 15 Nm HM5 3P Nm HM5/6 Nm HM5/6 2P ES35 Up to 0.26 M 2 Up to 500mm Dia Up to 0.43 M 2 Up to 650mm Dia Up to 0.96 M 2 Up to 950mm Dia Up to 1.35 M 2 Above 950 mm Dia Above 1.35 M 2 Up to 0.44 M 2 Up to 0.72 M 2 Up to 1.58 M 2 Up to 1.76 M 2 Up to 2.46 M 2 Above 2.46 M 2 ES36/50 ES36 R T Only Up to 0.11 M 2 Up to 300mm Dia Up to 0.18 M 2 Up to 0mm Dia Up to 0.44 M 2 Up to 650mm Dia Up to 0.79 M 2 Up to 850mm Dia Up to 1.62M 2 Above 850mm Dia Up to 1.79 M 2 Above 1.79M 2 Up to 0.36M 2 Up to 0.64 M 2 Up to 0.72 M 2 Up to 1.36 M 2 Above 1.36 M 2 * For other multiple arrangements refer to Actionair Technical Sales Office 8 www.actionair.co.uk

Technical Data Pressure Drop Vs Velocity at intermediate Blade positions. Dampers tested were 600mm x 600mm square ES35R, 36R (Opposed Blade) 0 ES35P, 36P (Parallel Blade) 0 500 0 1 /4 OPEN 500 0 PRESSURE DROP (Pa) 50 10 5 1 /2 OPEN 3 /4 OPEN FULLY OPEN PRESSURE DROP (Pa) 50 10 5 1 /4 OPEN 1 /2 OPEN 3 /4 OPEN FULLY OPEN 2 2 1 0.5 1 2 5 10 DUCT VELOCITY (m/s) 1 0.5 1 2 5 10 DUCT VELOCITY (m/s) ES50R (Opposed Blade) 1500 0 ES50P (Parallel Blade) 1500 0 500 500 PRESSURE DROP (Pa) 0 0 50 10 1 /4 OPEN 1 /2 OPEN 3 /4 OPEN 5 5 FULLY OPEN PRESSURE DROP (Pa) 50 10 1 /4 OPEN 1 /2 OPEN 3 /4 OPEN FULLY OPEN 2 2 1 1 0.5 1 2 5 10 0.5 1 2 5 10 DUCT VELOCITY (m/s) DUCT VELOCITY (m/s) www.actionair.co.uk 9

Technical Data Continue Damper Leakage ES36 Closed Blade leakage 0mm wide x 0mm high damper ES50 Closed Blade leakage 0mm wide x 0mm high damper 0 1500 0 500 500 DIFFERENTIAL PRESSURE (Pa) 0 50 DIFFERENTIAL PRESSURE (Pa) 0 50 10 1 2 5 10 50 1 2 5 10 50 10 LEAKAGE (I/s/m2) LEAKAGE (I/s/m2) 10 www.actionair.co.uk

Specification ES35 Air control dampers to EN1751 class 0* and DW144 class B casing leakage comprising of 1.5mm thick x 157mm triple Vee galvanised steel blades with synthetic blade bearings. Housed in a 1.2mm thick x 165mm deep galvanised steel casing. Integral mm peripheral flanges with pre punched corner fixing holes to suit proprietary duct flanges. Damper blades within damper casing. Drive mechanism mounted outside airstream. ES35 as manufactured and supplied by Actionair ES36 Air control and shut off dampers EN1751 class 2* and DW144 class B casing leakage comprising of 1.5mm thick x 157mm triple Vee galvanised steel blades with silicone coated glassfibre scrim blade seals and stainless steel side gasketting. Synthetic blade bearings. Housed in a 1.2mm thick x 165mm deep galvanised steel casing. Integral mm peripheral flanges with pre punched corner fixing holes to suit proprietary duct flanges. Damper blades within damper casing. Drive mechanism mounted outside airstream. ES36 as manufactured and supplied by Actionair. ES35 Stainless Steel Air control dampers EN1751 class 0* and DW144 class B casing leakage comprising of 1.5mm thick x 157mm triple Vee 316 stainless steel blades with stainless steel blade bearings. Housed in a 1.2mm thick x 165mm deep 316 stainless steel casing. Integral mm peripheral flanges with pre punched corner fixing holes to suit proprietary duct flanges. Damper blades within damper casing. Drive mechanism mounted outside airstream. ES35 Stainless Steel as manufactured and supplied by Actionair ES36 Stainless Steel Air control and shut off dampers EN1751 class 2* and DW144 class B casing leakage comprising of 1.5mm thick x 157mm triple Vee 316 stainless steel blades with silicone coated glassfibre scrim blade seals and stainless steel side gasketting. Stainless steel blade bearings. Housed in a 1.2mm thick x 165mm deep 316 stainless steel casing. Integral mm peripheral flanges with pre punched corner fixing holes to suit proprietary duct flanges. Damper blades within damper casing. Drive mechanism mounted outside airstream. ES36 stainless steel as manufactured and supplied by Actionair. ES50 Air control and shut off dampers EN1751 class 3* and DW144 class B casing leakage comprising of profiled aerodynamic aluminium aerofoil blades with blade seal tips and stainless steel side gasketting. Synthetic blade bearings. Housed in a 1.2mm thick x 165mm deep galvanised steel casing. Integral mm peripheral flanges with pre punched corner fixing holes to suit proprietary duct flanges. Damper blades within damper casing. Drive mechanism mounted outside airstream. ES50 as manufactured and supplied by Actionair. ES CIRC, ES FLOV and ES SPG As appropriate rectangular model with additional note: Spigotted circular or flat oval components sealed and attached to damper flanges manufactured in the same material as the base damper.. *Based on a 1m x 1m damper. Ordering Information ES35, ES36 and ES50 Example Quantity Series Casing Type Operation Control Option Duct Size Casing Leakage 10 ES35 FLA R X 10 (W) x 0 (H) B Number ES35 FLA R Opposed Blade X Extended Shaft Control B Required ES36 Flanged Movement (standard option) C (Requires side Covers) ES50 SPG P Paralled Blade Q Manual Hand Quadrant Spigotted Movement E Electrical Operator 24V or 230V open/closed 24V or 230V spring return or 24V modulating. JS Jackshaft IB Inboard OB Outboard FB Face and Bypass For further application, technical and pricing information, please refer to Actionair Sales Office. www.actionair.co.uk 11

Ruskin Air Management Limited is a ISO 9001 and 101 registered company. The statements made in this brochure or by our representatives in consequence of any enquiries arising out of this document are given for information purposes only. They are not intended to have any legal effect and the company is not to be regarded as bound thereby. The company will only accept obligations which are expressly negotiated for and agreed and incorporated into a written agreement made with its customers. Due to a policy of continuous product development the specification and details contained herein are subject to alteration without prior notice. Comprehensive and detailed information is available for all Actionair products. Visit our website at www.actionair.co.uk Ruskin Air Management Limited South Street, Whitstable, Kent CT5 3DU England. Tel: 01227 276 Fax: 01227 264262 Email: sales@actionair.co.uk Website: www.actionair.co.uk LNNN00318