Invensys (Foxboro) IMV25 Multivariable Setup

Similar documents
Invensys (Foxboro) IMV25 Multivariable Setup

ET9500 BEMS Interface Box Configuration Guide

Introduction. Installation & Start-Up Sequence

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Issue 2.0 December EPAS Midi User Manual EPAS35

Instruction Manual Installation and Operation Guidelines for DWL5000XY and DWL5500XY Tilt Sensor Modules (Version 2.2)

USERS MANUAL MCD REMOTE OPERATOR

Supersedes CL2 (512) Form CL2 (615) STARTUP CHECKLIST PHONE: CUSTOMER ORDER NO: JCI TEL NO: JCI ORDER NO: JCI CONTRACT NO:

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

Totalflow. Cold Weather Enclosure and Equipment Installation Manual (AB)

PowerJet Sequential Injection INDEX. 1 Introduction 1.1 Features of the Software. 2- Software installation

Product Manual. Part Number: MVP-193 Mefi-6 ECU Revision: 1.0

SP PRO KACO Managed AC Coupling

EPAS Desktop Pro Software User Manual

MSD Boost Control Module PN 7763

COMMUNICATIONS SETUP DBS STARTER PANEL

ECT Display Driver Installation for AP2 Module

MSD LS Ignition Control PN 6014/60143

GENERAL The AuRACLE Engine Management System primary display provides a graphical representation of the following engine instrumentation:

INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7

Stepper Motor Drive. Description: Specifications:

SP PRO ABB Managed AC Coupling

MCS-BMS-GATEWAY STARTUP GUIDE Covers Model No. FPC-C35

Installing a Programmed Fronius SCERT in a Managed AC Coupled system

GENERAL MOTORS SERVICE PARTS OPERATION 6200 Grand Pointe Drive, Grand Blanc, MI 48439

MP461SC Flex Probes* Installation Instructions

IBM CMM Quick Reference Guide

PowerSTAR PS-2024-D. Maximum Power Point Tracking Solar Regulator. w w w. r o c s o l i d. c o m. a u. Contents

ProtoNode FPC-N34 and FPC-N35

ENC82 Environmental Enclosure Installation Instructions

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

MSD Boost Control Module PN 77631

Overview of operation modes

TachoReader Combo Plus

Hi-Z USB Wireless. Introduction/Welcome

Freedom egen System End-of- Line Functional Checklist

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

Torque Cell Installation Guide for Model 250i/250iP DynoWare RT Dynamometers.

EV Display V4 User Guide

CAN-Translator. User s guide

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

Torque Module Installation and User Guide for model 250i Motorcycle Dynamometers.

CurveMaker HD v1.0 2Ki Programmable Ignition programming software

2013 schedule. Training services brochure

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW

EIP APPLICABILITY & EFFECTIVITY

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: , Revision 1

INTECH Micro 2300-RTD6

80V 300Ah Lithium-ion Battery Pack Data Sheet

SMART TICKET INTEGRATION GUIDE

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n Revision 0

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02

Advanced User Manual

PLS 210 Single-Channel High-speed Programmable Limit Switch Module User s Guide

ALM-Inline. Accurate Lambda Meter V1.1.2 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED.

Rosemount 3095FC MultiVariable Mass Flow Transmitter with MODBUS Protocol

User s Guide FP-5060 SERIES. Micro-Flow Sensors. Shop online at omega.com SM For latest product manuals:

Sensormedics Vmax with ECG Tango M2 Interface Notes

Zodiac Max INSTALLATION MANUAL

PSC1-003 Programmable Signal Calibrator

Wide Bank 28 DS3 QUICK START GUIDE

PDC PROPELLER DE-ICE CONTROLLER

ABB AC500 Technical Help Sheet

Introduction to 3D Printing

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

Dynojet Research, Inc. All Rights Reserved. Air Fuel Ratio Module Installation and User Guide.

Harris IRT Enterprises Digital Resistance Tester Model XP

Air Fuel Ratio Module and AFR-4 Pump Assembly Installation and User Guide.

CurveMaker DFS v2.0 Dyna FS Ignition Programming Software

DELTA4000 Accessories

User Manual Solar Charge Controller 3KW

PRESSURE SENSOR INSTRUCTIONS

MP56xSA Flex Probes* Installation Instructions

IPC-PC Intelligent Pump Control Operation Manual

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

X11CA-IM MASTER MODULE

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

Safety Precautions Product Contents Product PIN Diagram LED indicators Product Dimensions Installation of Panel with Casing Wire Legend Power Wiring

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

Direct Communication Module

LU23, LU28 & LU29 Series Quick Start

D&D Motor Systems, Inc.

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Idle Timer Controller - A-ITC520-A Ford E Series Ford F250 - F Ford F250 - F550 (*B-ITC520-A) F650/F750

RDS. For Windows TORSION SPRING CALCULATOR For ROLLING DOORS Version 4 REFERENCE MANUAL

Tutorial: Calculation of two shafts connected by a rolling bearing

Motions and Forces Propeller

MSD Circle Track LS Ignition Control PN 6014CT

Fuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

GPI (Gas Pump Interface) with Cash Register Express - Integration Manual

ZT-USB Series User Manual

Insulated Cable and Wire Market in Canada to Market Size, Trends, and Forecasts

Touch plate serial number. Please save this info here for use later:

ABB Robotics. Product manual, spare parts Motor Units and Gear Units

KEMKRAFT ENGINEERING, INC. MODEL KEI-234 STEERING WHEEL TORQUE/INCLINOMETER TESTER

Flow Computer Installation

Transcription:

Invensys (Foxboro) IMV25 Multivariable Setup MEASUREMENT & CONTROL SYSTEMS

Intellectual Property & Copyright Notice 2011 by ABB Inc., Totalflow Products ( Owner ), Bartlesville, Oklahoma 74006, U.S.A. All rights reserved. Any and all derivatives of, including translations thereof, shall remain the sole property of the Owner, regardless of any circumstances. The original US English version of this manual shall be deemed the only valid version. Translated versions, in any other language, shall be maintained as accurately as possible. Should any discrepancies exist, the US English version will be considered final. ABB is not liable for any errors and omissions in the translated materials. Notice: This publication is for information only. The contents are subject to change without notice and should not be construed as a commitment, representation, warranty, or guarantee of any method, product, or device by Owner. Inquiries regarding this manual should be addressed to ABB Inc., Totalflow Products, Technical Communications, 7051 Industrial Blvd., Bartlesville, Oklahoma 74006, U.S.A. IMV25 Overview This document discusses the use of the Invensys (Foxboro) IMV25 multivariable. For the sake of clarity, the Invensys IMV25 will hereafter be referred to as the Foxboro IMV25 or the IMV25. This document concentrates solely on applications using the Foxboro IMV25 or instances when the Foxboro unit is used in concert with an ABB 267CS (XMV) external multi-variable (i.e., a multi-tube application). Various configuration changes are required by the ABB XMV when used with the Foxboro units. These changes are detailed in this document. Wiring, software configuration and Modbus addressing will be covered for both G4 and G3 generations. G4 FCU Technology The following section discusses installation and configuration of the Foxboro IMV25 with respect to Totalflow G4 devices (XFC G4 /XRC G4 ). In some applications (i.e., multi-tube), the IMV25 may be used in conjunction with the more familiar ABB XMVs. NOTE: Pay special attention to the screen shots discussing changes to the ABB XMV when used in conjunction with the Foxboro units.

Step 1 Electrical Installation of the Foxboro IMV25 RTD Probe RTD Probe SHIELD BLK BLK WHT WHT SHIELD BLK BLK WHT WHT IMV25 P/N: 1641200-XXX IMV25 P/N: 1641200-XXX Probe Cable Entry (Wiring Diagram is shown outside of conduit for clarity) + - 1 2 3 4 A (+) S B (-) + - 1 2 3 4 A (+) S B (-) PWR & RS-485 Cable Entry To XFC / XRC Device BUS + (Wiring Diagram is shown outside of conduit for clarity) GND VBATT VBATT PWR (-) BUS - BUS+ BUS+ BUS- BUS- SHLD Gnd Case Gnd RS-485 Cable 6-Conductor P/N: 2011648-001 Case Gnd GND ROD Connect the Shield GND from the RS-485 cable at the enclosure end of the cable to the Chassis GND Lug located on the bottom of the enclosure. For every other RS-485 cable to an additional device, attach Shield GND to Shield GND. DO NOT ground at any other place. WARNING: This drawing does not illustrate the installation methods required for hazardous locations. Prior to any installation in a Classified Hazardous Location, verify installation methods per the National Electrical Code and local codes. Figure 1 Foxboro IMV25 Wiring and Grounding Recommendations Step 2 RTD Wiring for the Foxboro IMV25 Figure 2 Foxboro IMV25 Wiring for 2, 3 and 4 Wire RTDs 1

Step 3 Software Configuration of the Foxboro IMV25 In a multi-tube application, the user may find it necessary to employ a mix of Foxboro IMV25s and ABB 267CS XMVs; however, there are several issues that need to be addressed when using the two units on a common RS-485 Modbus communication link. 3A In the Communications Setup tab (Figure 3), the user needs to select 16-Bit Word Swapped for the Register Format. Foxboro IMV25 must be set to 16-Bit Word Swapped ABB XMV must be set to 16-Bit Word Swapped Figure 3 Register Format Changes to 16-Bit Word Swapped 3B Factory Units: Foxboro IMV25 must be set to English ABB XMV must be set to Metric 3C Display Scroll: Foxboro IMV25 must be set to Disabled ABB XMV must be set to Enabled (if the XMV has a display) 2

3D Modbus Register: Foxboro IMV25 must be set to 401 ABB XMV must be set to 401 Setting the ABB Modbus Register to 401 informs the ABB XMV to look for the 16-Bit Word Swapped register format. 3E Timeout (Milliseconds): Foxboro IMV25 must be set to 100 Baud rate is assumed to be 9600. In the examples below, XMV 1 is an ABB XMV (Figure 4) and XMV 2 (Figure 5) is a Foxboro IMV25. Both are being used together in a 3-tube application; the third tube is supported by the host flow computer. Figure 4 XMV 1 (ABB 267CS XMV) 401, Metric Units and Enable Display Scrolling 3

Figure 5 XMV 2 (Foxboro IMV25) 401, English Units and Disable Display Scrolling Step 4 Changing the Modbus Address of the Foxboro IMV25 If only one multi-variable is being connected to the com port, the user will not have to perform these steps. All IMV25 units ship with a default Modbus address of 1. Requirements: A laptop with PCCU32 installed. Use PCCU 7.17 or later. An appropriate converter (i.e., RS-232 to RS-485, USB to RS-485, etc.). Totalflow stocks an RS-232 to RS-485 converter (Part #: 1800255-001). A single Foxboro IMV25 unit. Only one unit at a time can be connected to the laptop. Additionally, only one unit at a time can have its Modbus address modified. Figure 6 displays the wiring connection from the serial port on a laptop to the Foxboro IMV25. 4

Foxboro IMV25 12 Volt Power Supply +12V GND Bus - Bus + Totalflow Prt. No. 1800255-001 RS-232 to RS-485 Converter To laptop serial port Wiring for changing the Modbus address in the Invensys IMV25 unit Figure 6 Foxboro IMV25 Recommended Wiring for Modbus Address Change Step 5 Using TFModbus to Change the IMV25 Modbus Address Before using TFModbus to change the IMV25 s Modbus address, the user must copy IMV25.ini into PCCU32 s TFModbus sub-folder. A copy of IMV25.ini can be obtained by contacting Totalflow Customer Service at 1-800-442-3097, option 2. The following steps will walk the user through changing the IMV25 s Modbus address using PCCU32 s TFModbus tool. 5A Open PCCU32. Click the TFModbus toolbar icon (Figure 7). This will bring up the various Modbus drivers. If the user has copied IMV25.ini into the TFModbus sub-folder, it should be included in the list of.ini files. 5

Figure 7 Activate TFModbus Tool 5B Highlight IMV25.ini (Figure 8). Upon completion, click Open. Figure 8 Select IMV25.ini to Change Modbus Address 6

5C The next screen (Figure 9) enables the user to set and check the IMV25 Modbus address. Read the instructions on the initial Start Here tab. Clicking the Set XMV 2 tab will set the attached IMV25 to a Modbus address of 2. The baud rate is assumed to be 9600 baud, and the Response Delay is set to zero milliseconds. DP, AP, Temp and the modified Modbus address will be displayed. Figure 9 Setting the Foxboro IMV25 to Modbus Address 2 If additional help is needed to use the TFModbus tool, refer to the Help screens by clicking the Help button. Step 6 Electrical Installation of ABB 267CS XMV It is not the intent of this document to discuss the installation of the ABB XMV. Figure 10 is included for completeness and the user s convenience. 7

Figure 10 ABB 267CS XMV Wiring and Grounding Recommendations Step 7 Software Configuration of the ABB XMV Changes to the ABB XMV configuration are only required when the XMV is used in conjunction with the Foxboro IMV25. For an explanation of the software configuration changes, refer to step 3. Step 8 Using TFModbus to Change the Modbus Address of the ABB 267CS XMV Requirements: A laptop with PCCU32 installed. Use PCCU 7.17 or later. An appropriate converter (i.e., RS-232 to RS-485, USB to RS-485, etc.). A single ABB XMV unit. Only one unit at a time can be connected to the laptop and have its Modbus address modified. 8

ABB XMV - + - + +12V GND Bus - Bus + Wiring for changing the Modbus address in the ABB XMV unit Figure 11 ABB 267CS XMV Recommended Wiring for Modbus Address Change Before using TFModbus to change the XMV s Modbus address, the user must ensure that the xmvsetup.ini is in PCCU32 s TFModbus sub-folder. If the file is not present, a copy can be obtained by contacting Totalflow Customer Service at 1-800-442-3097, option 2. The following steps will walk the user through changing the XMV s Modbus address using PCCU32 s TFModbus tool. 8A Open PCCU32. Click the TFModbus toolbar icon, MB (Figure 12). This will bring up the various Modbus drivers. 9

Figure 12 Activate TFModbus Tool 8B Highlight the xmvsetup.ini (Figure 13). Click Open. Figure 13 Select xmvsetup.ini to Change Modbus Address 10

8C The next screen (Figure 14) enables the user to set the ABB XMV Modbus address. Read the instructions on the initial screen. Example: Clicking the XMV 2 tab will set the attached XMV to a Modbus address of 2. The baud rate is assumed to be 9600 baud, and the Response Delay is set to 20 milliseconds. DP, AP, Temp and the modified Modbus address will be displayed to the user. Figure 14 Setting the ABB XMV to Modbus Address 2 If additional help is needed to use the TFModbus tool, refer to the Help screens by clicking the Help button. 11

G3 Flow Computer Considerations Many of the same installation and configuration issues regarding the G4 units are applicable to the G3 devices (XFC/XRC). In the older G3 units, the XMV Interface application is turned on as a separate application (Application Slot #8) in the Application tree-view. It is then associated with a specific communication port. In the G4 world, the XMVs are turned on as communication application (i.e., under the Communication applications in the Application tree-view). As this is the case, the same settings used for G4 devices will apply to the G3 devices. G3 FCU Example In the following example, a G3 XFC was loaded with the 2101050-028 Flash (a very basic Flash) and 2100961-006 station files. These station files (or configuration files) support four tubes. The first tube is associated with the host XFC. The remaining tubes are supported with multi-variables. Tubes 2 & 4 are supported using an ABB XMV, while tube 3 uses the Foxboro IMV25 multi-variable. The station files established Com2 as a Modbus Host to support the multi-variables. A The user will need to set the Register Format to 16-Bit Word Swapped (Figure 15). Figure 15 Register Format Changes to 16-Bit Word Swapped 12

Figure 16 Advanced Tab Under the XMV Interface, the user will need to modify a few settings for XMV 2, the Foxboro IMV25 (Figure 17). B C Under the XMV Setup, the Factory Units must be set to English. Display Scroll must be set to Disabled. D Modbus Register should be set to: Foxboro IMV25 must be set to 401 ABB XMV must be set to 401 Setting the ABB Modbus Register to 401 informs the ABB XMV to look for the 16-Bit Word Swapped register format. Figure 17 XMV 2 (Foxboro IMV25) 401, English Units and Disable Display Scrolling 13

ABB Inc. Totalflow Products 7051 Industrial Blvd. Bartlesville, Oklahoma 74006 Tel: USA (800) 442-3097 International 001-918-338-4880