Operation Manual For NDJ-9S Digital Rotary Viscometer

Similar documents
Operation Manual For NDJ-4 Rotary Viscometer MADE IN CHINA

NDJ Series Product Standard: Q/SGKW5 SNB Series Product Standard: Q/SGKW6. Operation Manual for NDJ Series and SNB Series Digital Viscometer

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Instruction Manual. DMF-1-Series Coriolis Mass Flow Meter

Positive displacement batch controller

OVERVIEW OF CONTROLS

ETHOS Digital Sound Level Meter. Operating Manual

Load Cell for Manually Operated Presses Model 8451

SPECIFICATION SHEET Pulse tool / Impact Wrench Testing System MODEL : IWT-101

Standard BQ-P6 Binder Padder and Spine Taper

OPERATION MANUAL. BALTECH VP-3450 device for bearing diagnostics using shock pulse method

BGD 160 series Portable Digital Viscometer INSTRUCTION MANUAL

Table of Contents. Chapter 1 Product Summary... 2

For BIS Use Only Doc: CED 50(7436) BUREAU OF INDIAN STANDARDS

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

M-11 MARINE DIESEL ENGINE FUEL INJECTOR

Tension and Compression Load Cell Model 8435

Technical Part. Technique Specification

BRAKE TESTER DECELEROMETER

Rotor No.3, No.4, No.5 No.1, No.2, No.3 Cup A, B No.3 Cup Extension Rod - 1 PC Batteries 4pcs, IEC R6 4pcs, IEC R6

FLOW METER WITH FLOAT type K

SYLLABUS. EASA 748/2012 Part-21 SUBPART F/G POA - ADVANCED (FLY Course code: 004-C-P) Issue of FLY EN

FACF AUTOMATIC CAPSULE FILLER SERIES USER MANUAL

Model TUR-200D Turbine Flowmeter

Customer Name. Instruction for Operation. Single Head Sleever

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SELECTRIC, INC. Selectric (PX) Full Voltage Type Motor Control Panel Installation And Operation Manual

Please read these instructions completely before proceeding with installation. Read all maintenance guidelines on page 7 before operating the vehicle.

PowerLink JC Series Torque Transducer User Manual

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS

Operating / Assembly Instructions Type A and CS Coupling

AUTOMATIC FILM APPLICATOR AB3120, AB3220, AB3320, AB3400, AB3125, AB 3225, AB3325, AB3405

HK Equipment CZD Brake tester Max. weight Size Roller size Measure range Error Rated use condition: CCH Sideslip tester 10,000kg (15,000kg) 3990 x 840

INSTRUCTION MANUAL HI 921 AUTOSAMPLER

American Weigh Scales LS-110. User Manual. LS-110 (110lb x 0.2lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 2.

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

EMC-HD. C 01_2 Subheadline_15pt/7.2mm

WALKIE HIGH LIFT HYDRAULIC SYSTEM

Unit AE01K Knowledge of Locating and Correcting Simple Electrical Faults in the Automotive Workplace

GLASSCO LABORATORY EQUIPMENTS PVT. LTD.

User Manual Journey Onward

Kit No Please read these instructions completely before proceeding with installation. Figure 1 MN-614 (06601) ECR

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum

Techcon Systems TS500R-PC Controller For Positive Displacement PC Pump

EGQ 212: Duct transducer, CO 2 and temperature

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

GPM Hydraulic Flow Meter User Manual

HOUSTON OILFIELD EQUIPMENT 9669 PORT ERROLL RD. HOUSTON, TX PHONE: (713) FAX: (713)

Weighing Scale IDS-802. User Manual

JGAURORA 3D PRINTER MODEL: A5 USER GUIDE

Z125 Front Fork Upgrade kits. Installation SOP

Unit AE06K Knowledge of Diagnosis and Rectification of Vehicle Auxiliary Electrical Faults

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

PPI - 90 Portable Power Pallet Inverter Instruction Manual

Smart Valve Positioner

Smart Electromagnetic Flowmeter Detector for Sanitary use

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

Detector (for water measurement applications)

Models: DC Electric Vibrators. Operating Instructions CEG CEG CEG CEG CEG

Intelligent torque meter tester

Comfy Dry Bath Incubator

K - Flow Meter with Float

APPLICATION NOTE. Labeling Machine

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

Instruction Manual. Vibration Calibrator VC20. Manfred Weber. Metra Mess- und Frequenztechnik in Radebeul e.k. Meissner Str D Radebeul

Instruction Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION MRC.VER

American Weigh Scales SG-300. User Manual. SG-300 (300g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.

GRAVITY MEASUREMENT, INC.

MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus

Model 5000 Vortex Meter

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Thermo-hygrometer-anemometer VT 210

Operations Manual. Eagle 2000 Series Stretch Wrapper Models B, BE, BHS, EB, EBT, BWS

P Flaming/Brown Micropipette Puller System User Interface Manual Rev 1.12c ( ) One Digital Drive Novato, CA 94949

SELECTRIC, INC. Selectric (PA) Autotransformer Type Motor Control Panel Installation And Operation Manual

Guideline No.M-10(201510) M-10 Marine Diesel Engine Fuel Injection Pump

Thermo-hygrometer-anemometer VT 210

Advanced Hybrid Wind / Solar Charge Controller. User Manual

HIGHLIGHT. Note KERN HCD. Hanging scales/crane scales. Complete crane scale for lower to medium load ranges

SANITARY SELF PRIMING PUMP Manual

Chapter 1 Vehicle characteristics and safe driving rules Vehicle characteristics

DYNAMOMETER CONTROLLER MODEL 5220 INSTRUCTION AND REFERENCE MANUAL

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

DIESEL Engine Fire Pump Controllers Features

To put integrity before opportunity To be passionate and persistent To encourage individuals to rise to the occasion

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011

JJG Translated English of Chinese Standard: JJG

COMMISSION REGULATION (EU) / of XXX

Series 10-ZSE40A(F)/10-ISE40A

RS ACTUATO RS ACTUATO

SWISS MADE EXECUTIVE. Series 360 ES

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

To be the Chief Evangelist CR-10S Pro Printer Guide Book To make Top-quality 3D printer

Unit HV04K Knowledge of Heavy Vehicle Chassis Units and Components

BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS)

Models SPG5A and SPG6A

Table of Contents. 1. The Statement Overview Instrument Familiarization Method of use General Specifications...

Transcription:

Operation Manual For NDJ-9S Digital Rotary Viscometer

1 Contents 1. General... 2 2. Main technical data... 2 3. Working principle... 2 4. Installation... 3 5. Operation procedures... 4 6. Precautions... 7 7. Packing List... 8

1. General NDJ-9S is a Digital rotary viscometer which has been upgraded. This viscometer adopts advanced mechanical design technology, manufacturing process and micro computer control technology, make the data acquisition correct and the display adopts LCD with blue backlight and high brightness, make the displayed data clear. NDJ-9S Digital rotary viscometer is used for determining the liquid viscose capacity and the absolute viscosity. Comparing with other similar products, this instrument has the following features: High measuring accuracy; Stable in measured display; Easy operation and read-out; Excellent in Anti- interference. NDJ-9S has been widely used to determine and measure the liquid viscosity in many applications such as grease, painting, pharmacy and adhesives. 2. Main technical data 1) Measurement range: 1~1 10 5 mpa s 2) Rotor types: 1#, 2#, 3# and 4# rotors; (You can determine viscosity as low as 0.1mPa.s with 0# rotor.) 3) Rotor velocity: 6 rpm, 12 rpm, 30 rpm, and 60 rpm(automatic) 4) Measurement error: ±5% (Newton liquid) 5) Power supply: 220V±10% 50z±10% 6) Ambient temperature: 5 C~ 35 C;Relative humidity: 80% 3. Working principle This instrument is a rotary viscometer; rotor could be rotated constantly by the variable speed motor. Rotate the standard rotor, the rotors will subject to a torque moment proportional to liquid viscosity because of the liquid viscose hysteresis. The torque moment will be measured by the sensors and processed into the viscosity and shown on the display. This instrument adopts micro computer technology, range (rotor number and speed) can be set and the data determined by sensor can be processed conveniently, and the rotor number speed viscosity etc. can be displayed clearly on LCD. The instrument was designed and manufactured with 4 rotors (1#, 2#, 3#, 4#) and 4 different velocity (6 rpm, 12 rpm, 30 rpm, and 60 rpm), which 2

3 enable it to measure any viscosity value in the given range. 4. Installation 1) Instrument structure Figure 1 (1) Level indicator (2) LCD (3) Housing (4)Protection bracket (5) Base (6) Operation key (7) Rotor connector (8) Rotor (9) Level adjustment knob 2) Installation i. Check power supply, it should meet the requirement of the instrument: according to the relevant provisions, the instrument should be grounded. ii. No corrosive gas, no electro-magnetic interference and no severe vibration in instrument surrounding area. iii. Screw the stanchions into the hole on the base, put the tooth side of the stanchions facing on the front of base, and tight it by a wrench to avoid loosen (Figure 2). iv. Adjust the clamping bolt to make the instrument moving up and down, and to protect it drop down from stanchions.

4 v. Loosen and take away the yellow cover cap on the bottom of viscometer. vi. Adjust the level adjustment screw; make the level bubble to locate on the central point. Notice: PC computer interface and Printer interface in figure 3 have not been used yet. 5. Operation procedures 1) Prepare the liquid to be measured and put it into a glass beaker or a right angle container with the diameter not smaller than 70 mm and the

5 height not less than 125mm. 2) Take care of the liquid temperature. 3) Ensure the instrument is level. 4) Adjust the lifting screw and put the rotor into the measured liquid till the level mark on the rotor reach the liquid surface. 5) Control panel operation and display interface i. Figure 4: Control panel operation ii. Turn on the power switch, enter standby state, the instrument display both Chinese and English character. Screen shown in figure 5. Press or to select language mode you need, press OK to set, press OK to enter, screen shown in figure 6: Cursor stop at 1#, press or to select the rotor you need. iii. Press or, switch to rotate speed mode. Cursor stop at 6RPM (Figure 6), press or, select rotate speed, the instrument has five rotate speeds: 6 rpm, 30 rpm, 60 rpm and auto mode. After setting rotor and rotate speed, press OK, the rotor begins to rotate, and the instrument begins to measure, screen shown in figure 7 iv. After setting auto mode and rotor, press OK, the instrument begins to measure automatically, search appropriate speed gradually. Finally, display the measured result or the required rotor number

6 automatically. Rotor 1 # Rotate speed 6RPM Viscosity Percent XX.X% Figure 7 In figure 7, the rotate speed unit is RPM, and the viscosity unit is mpa s; the vertical bar on right side displays the sampling process; percent: the measured viscosity is the percent of the full scale. v. In figure 6, move the cursor to output mode, press or to select communication state or print state Notice: Print function and communication function have not been used yet. vi. In figure 6, move the cursor to clock mode, press or to select display mode or amendment mode, if you choose the display mode, current time can be displayed; if you choose the amendment mode, you can amend time and date. vii. Press Reset, viscometer will stop measuring; press OK again, the viscometer will begin to measure according to the rotor number and rotate speed which you set last time. viii. Estimate the viscose range approximately, and then select the rotor and the rotate speed based on the range table. ix. If the viscosity of liquid cannot be estimated, the measured liquid should be regarded as high viscosity liquid. Select rotor from small to large (the rotor number from high to low) and select rotate speed from slow to fast. In general, measure high viscosity liquid, you should use small rotor and slow speed, measure low viscosity liquid, you should use large rotor with fast speed. x. This instrument has overload alarm function, if the measured value bigger than 100%, measured value will be displayed over. In order to ensure measurement precision, the range percent should be within 10%~100%. xi. Press Reset key at any time, system will return to the initial state. xii. Range table

7 Velocity range 60 30 12 6 rotor 0 10 20 50 100 1 100 200 500 1000 2 500 1000 2500 5000 3 2000 4000 10000 20000 4 10000 20000 50000 100000 6. Precautions 1) The instrument has been regulated strictly before ex-factory. Please read the operation manual carefully before you use. 2) This instrument should be used under the designed voltage and frequency and their allowable error ranges, or incorrect results could be resulted. 3) Care should be taken for mounting or removing rotors, slightly and lift the connecting screw bolt to avoid a transverse force acting on rotor to cause it bending. Keep cleaned on screws and connecting points between rotor and connecting bolt rod, or a unstable rotation could be caused in the real measurement. 4) The instrument mounted with rotor should not be revolved without liquid to avoid damaging the axis tip. 5) After completing measurement each time, the rotor should be fully cleaned (rotor should be removed from instrument for cleaning), then place it on the protection bracket. 6) When moving or shipping instrument, put on the yellow caver cap and lift the connecting bolt rod and screw the bolt on the cap tightly. Notice: Before turning on the instrument, you should take away the yellow cover cap, avoid damage. 7) Unauthorized removing or replacing the instrument part, and applying lubricates are not allowable. 8) Suspension, emulsion or polymer and other high viscosity liquids are non-newton liquids, their viscosity will change with shear velocity and time, it is normal for their measured inconsistent results under the selected rotor and velocity and time, and it is not resulted from the instrument problems (in general, the rotor and velocity and time should be specified for non-newton liquids).

8 9) The cautions should be taken for followings to obtain a good measuring result: i. Accurately control the temperature of liquid to be measured; ii. Put the rotor immerged in liquid the unchanged temperature for enough time under make its temperature same as liquid; iii. Ensure the liquid homogeneity; iv. Put the rotor located on the center of the liquid container in real measurement; v. Remove bubbles adhered on the rotor when put it into liquid; vi. Use the settings close to full range as far as possible for measurement; vii. Use rotor protection bracket for measurement; viii. Ensure rotor cleaned; ix. Strictly follow the operation instruction for measurement. x. Please use 0# rotor when the viscosity of measured liquid less than 15mPa.s 7. Packing List No. Name Quantity Standard configuration Optional configuration 1 NDJ-9S Digital Rotary Viscometer 1 Qt. 2 Rotors, 1 #, 2 #, 3 # and 4 # 1 Qt of each 3 Power adapter 1 Set 4 Protection bracket 1 Qt. 5 Base 1 Qt. 6 Lifting assembly 1 Set 7 Operation manual 1 Qt. 8 License 1 Qt. 9 Quality certificate 1 Qt. 10 0 # rotor 1Qt.