Health Based Asset Management. rjd

Similar documents
Low and medium voltage service. Power Care Customer Support Agreements

Reference Guide For Asset Management Inventory and Risk Analysis (Drinking Water)

Introduction to Condition-Based Maintenance Best Practices

V. Design, Application, Maintenance & Operation Technical Requirements

ADVANCED DRIVER ASSISTANCE SYSTEMS, CONNECTED VEHICLE AND DRIVING AUTOMATION STANDARDS

IAE-101: Electrical Fundamentals for Non-Electrical Personnel

Aspects of Heavy-Duty Truck PREDICTIVE. Maintenance. Bill Wade Wade&Partners

AV-25 Rotating Equipment Health Machine Condition Monitoring-MCM

Alternator protection, part 1: Understanding code requirements

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15

LECTURE 12 MAINTENANCE: BASIC CONCEPTS

Improving predictive maintenance with oil condition monitoring.

WINDROCK 6400 PORTABLE ANALYZER Premium Portable Monitoring for Reciprocating Machinery

EPSRC-JLR Workshop 9th December 2014 TOWARDS AUTONOMY SMART AND CONNECTED CONTROL

Understanding the benefits of using a digital valve controller. Mark Buzzell Business Manager, Metso Flow Control

Maintenance Issues for Local Fluid Fertilizer Plants

Smart Grid Implementation Strategies. Ray Gogel February 2010

PGM-FI MAIN RELAY CIRCUIT TROUBLESHOOTING

WINDROCK 6400 PORTABLE ANALYZER Premium Portable Monitoring for Reciprocating Machinery

Advanced Protective Relay Training

VALVE CONDITION ASSESSMENT USING NEW TECHNOLOGY. Sagar Khadka. ACTEW Water

Battery Technology for Data Centers and Network Rooms: Site Planning

High Voltage Electrical Maintenance Training

Overview. MISTRAS Overview

Agenda / ESPS Electrical Safety Program Solutions INC.

High Voltage Electrician Training

CCHMP Comments on ConocoPhillips Incident Report For 10/22/10 Flaring Event

TRANSMISSION - NGC. Symptom: P0706-CHECK SHIFTER SIGNAL. When Monitored and Set Condition:

Unit MC07K Knowledge of Diagnosis and Rectification of Motorcycle Engine Faults

Large Electric Motor Reliability: What Did the Studies Really Say? Howard W Penrose, Ph.D., CMRP President, MotorDoc LLC

Detection of Faults on Off-Road Haul Truck Tires. M.G. Lipsett D.S. Nobes

Thermography Report. Inspection Site: Lucky Mining Co. Rocky Rd Smithville, NSW. Requested By: John Seemore. Date of Inspection:

Case Study. Creative Lighting Company

BLADEcontrol Greater output less risk

ASI-CG 3 Annual Client Conference

GT 710. Surface-Mounted, Low Energy, ADA*, Fire-Rated Swing Door Operator PRODUCT FEATURES

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

Clutch System Troubleshooting Guide-Service Tips

Building the Ultimate Reliable Plant

P2284 REQUESTED INFORMATION. Pinpoint Test Ao: Injector Control Pressure Too High. Print Ford Pickup 6.0L Eng F250 Super Duty.

New Machinery Directive

P0750-LR SOLENOID CIRCUIT

PREVIEW ONLY. Course 106 INSTRUCTOR GUIDE. HVAC Systems Introduction and Overview. Module 1: Overview of Rail Car HVAC and General Safety Procedures

Is Your Wiring System Safe and Energy Efficient?

MAXIMIZING PUMP RELIABILITY THROUGH PRECISION LUBRICATION

Patient Care Facility

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

TROUBLE SHOOTING FOR NEGATIVE GROUND TRUCKS

RNRG WHITE PAPER Early Detection of High Speed Bearing Failures

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

USER S GUIDE HIGH INTENSITY ULTRASONIC PROCESSOR

Media Number -SENR Publication Date -01/10/1977 Date Updated -12/10/2001

Nico Brunke Operations Manager Equipment performance management South Africa Total Motor Management

Knowledge of Diagnosis and Rectification of Light Vehicle Engine Faults

TC Series Cooling Systems

EMPACK MECHELEN, 11 OCTOBER 2017, STAF SEURINCK, ABB BENELUX Upcoming digital solutions and services.

18. IGNITION SYSTEM 18-1 SYSTEM DIAGRAM 18-2 IGNITION SYSTEM INSPECTION 18-5 SERVICE INFORMATION 18-3 IGNITION COIL 18-8 TROUBLESHOOTING 18-4

P0706-TRANSMISSION RANGE SENSOR RATIONALITY

PM/ECCM Course Description and Outline

Fuel Selector Valve- Diagnosis/Replacement

Troubleshooting Guide

A Tutorial on Using Reliability Growth Cause Analysis (RGCA)

Why do Machines and Equipment Continue to Fail in Companies? (and how the Plant Wellness Way lets you build magnificent reliability.

FIRE HYDRANT SPECIFICATION CHANGE SUBMITTAL

P0750-LR SOLENOID CIRCUIT

Battery Maintenance for Medical Devices

DID YOU KNOW THIS HOLE COULD BE COSTING YOUR COMPANY MORE THAN $12,000 ANNUALLY?

ADVANCED PID TROUBLESHOOTING

08/01/ Chassis Cab Occupant Restraint System Information

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

ABB DRIVES SERVICE. Optimize your wind economy. Wind Converter Services

Water Valve Shutoff. WVS Water Valve Shutoff

Group 3: Pricing from 1 April 2018 and load management

Hydraulic Maintenance & Troubleshooting. Content - Norman Kronowitz Presenter Jim Trinkle

Patient Care Facility

Autonomously Controlled Front Loader Senior Project Proposal

Additions, Revisions, or Updates

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

ELECTRONIC FUEL INJECTION

M.V. LIMITING FUSE WITH THERMAL PROTECTION

AUTOMATIC OPERATOR SENSORS & ACCESSORIES

B1D7B SEAT HORIZONTAL MOTOR CONTROL CIRCUIT PERFORMANCE

1998 Acura 3.5RL. F - BASIC TESTING' '1998 ENGINE PERFORMANCE Acura - Basic Diagnostic Procedures

April 17, 2018 CITY OF BONNEY LAKE WATER PROJECTS. Geoff Dillard, P.E.

Bench fume hood with horizontal sash - 14" working sash height. Bench fume hood with vertical sliding doors 14" working gap between doors

SYSTEM OPERATION IMPORTANT CAUTIONS

2015 IPWEA Queensland Conference Mackay. 14 th October 2015

HUIZHI XIE (JOINTLY WITH HONGFEI LI AND YASUO AMEMIYA)

SOME BASICS OF TROUBLESHOOTING

Team Aware Perception System using Stereo Vision and Radar

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

PROACTIVE PRODUCT SERVICING

REVO SSR, S1PH & A1PH up to 40A The solid-state relay evolution

VEEDER-ROOT COMPANY. Product Knowledge Session. Understanding Line Leak Detection Methods / Test Type / Certifying

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

UTSA 1604 Campus Automated Sliding Doors Assessment

PROTECT YOUR BUSINESS WITH INSITE360

ES Fueling Aircraft, Vehicles, and Auxiliary Equipment Document Identification Number

Battery Monitoring Why Technology Matters. Mats Karlstrom V.P. Sales & Marketing, Alber

Transcription:

Health Based Asset Management 1

Health Care Proactive and Reactive Approaches Physical Routine Screenings Symptoms Targeted Diagnostics Emergency Targeted Diagnostics 2

What is the health of the assets? Is it important to know? How do we assess? 3

What is the health of the Assets? Is it important to know? How do we assess? 4

Asset Health Find & repair these problems or let them fail? Fuse Box Aerial Electrical Cable 5

Reactive & Proactive Approaches Reactive: Run to failure Break / Fix Preventive: Scheduled tasks that minimize risk of failure. Predictive/Health-Based: Systematic monitoring to assess machine health 6

Annual Maintenance Cost Per Horsepower Predictive $7-9 Health Monitoring Preventive $11-13 Reactive $17-18 Benefit: $$$$$ / Reliability Source: ISA s InTech Magazine, December 1987, pages 29-32: 7

Right Balance Operating Equipment Asset Management Handbook Compiled by John Mitchell Penn State Applied Research laboratory 8

Asset Failures Effective Maintenance programs are guided by the consequences of asset failure. Safety & Environmental Operational Economical 9

Cost Operating Equipment Asset Management Handbook Compiled by John Mitchell Penn State Applied Research laboratory 10

Asset Failures Severe $$$$$ Failure Consequences None or Insignificant $ Major Maintenance Effort 11

Asset Maintenance / Failure Matrix Severe Failure Consequences 1 2 Crisis Maintenance (Reactive) Adequate Maintenance *Reliability Focused Maintenance (Proactive) 3 4 Excessive Maintenance None or Insignificant (Reactive) (Proactive) Maintenance Effort Major 12

Potential - Failure Curve Reliability Centered Maintenance - John Moubray Normal Start of failure Failure detection with diagnostic equipment Health Condition Failure detection with human senses Time Point of failure 13

Health/Condition Assessment & Diagnostic Programs Instrument verification Infrared inspections Ultrasonic leak detection Vibration analysis Motor testing and inspection Motor starter inspections Protective relay testing Stationary battery testing Transformer inspection Insulating & Lubricating oil testing Wire-to-water efficiencies Precision alignment Power quality monitoring 14

Health/Condition Assessment Programs Tank Inspections Hydrant inspection & flushing Valve exercising Pipe inspections Pipe cleaning Corrosion monitoring Corrosion protection Large meter testing Hydraulic monitoring Leak monitoring Pressure & control valve PM s Backflow device testing 15

The Cheap Fix PAW Facilities: July - December, 1999 Repair cost if allowed to fail Repair cost of scheduled repair Difference $117,000 $17,000 $100,000 Benefit: Est. savings (avoided costs) $100,000 16

Six Patterns of Failure A Infant and age related failure with wear out zone - 4% of failures age B Age related failure with wear out zone - 2% of failures age C Slowly increasing probability of failure (fatigue) - 5% of failures age Reliability Centered Maintenance - John Moubray 17

Six Patterns of Failure D Few failures when new-then constant probability of failure - 7% of failures age E Constant probability of failure at all ages-random failure - 14% of failures age F Infant mortality, then constant probability of failure - 68% of failures age Reliability Centered Maintenance - John Moubray 18

Failure Pattern B Constant probability of failure - failure at wear out zone 2% of failures B Useful Life Age Reliability Centered Maintenance - John Moubray 19

Lighting Failure Pattern B 20

Battery Failure Pattern B 21

Failure Pattern F Infant mortality, then constant probability of failure 68% of failures F Age Reliability Centered Maintenance - John Moubray 22

Root Causes Characteristic of certain devices Poor design or manufacturing quality Incorrect installation or operation Unnecessary & excessively invasive maintenance Poor maintenance practices or workmanship 23

Asset Health Do You Want Extended Life? Reliability? Efficiency? Quality? 24

You Must Employ Health Based Programs 25