The electric motors are designed for driving equipment that requires continuous operation, and their high efficiency reduces energy consumption.

Similar documents
521B0850 DKCFN.PD.010.FA2.02

521B0851 DKCFN.PD.010.FB1.02

521B0850 DKCFN.PD.013.FA5.02

The pumps are fixed displacement pumps in which the flow is proportional to the number of revolutions of the input shaft and the pump displacement.

Data sheet APP

Water pumps for Desalination APP 16-22

MAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com

MAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com

Energy Recovery Device isave 21-40

Data sheet. Data sheet. APP pumps APP APP Pumps APP 53 / APP 65 / APP 78 / APP 86. ro-solutions.com. hpp.danfoss.com

Tel: +44 (0) E mail: Web: Data sheet. APP pumps APP ro-solutions.com

Data sheet. Data sheet. APP pumps APP APP Pumps APP 53 / APP 65 / APP 78 / APP 86. ro-solutions.com

APP S 674 pumps APP S / APP S APP S

APP pumps APP / APP / APP (W) / APP / APP / APP Lenntech. Data sheet

APP pumps APP / APP / APP / APP (W) / APP / APP / APP 21-43

APP pump instruction APP 21-43

APP pump instruction APP and APP 16-22

PAHT pump PAHT X

Energy Recovery Device isave 21-40

APP S pumps APP S / APP S / APP S 21-38

2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps

PAHT pumps / PAHT G pumps / ATEX PAHT G pump

Nessie High-Pressure Pumps for technical water, type PAH

High-Pressure Pumps for Fire Fighting, type PAHF 20/25/32/40

PAH / PAHT / PAHT G pumps

Parallel coupled APP pumps

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

2/2 way Directional Control Valves, type VDH For inline mounting and Cetop 3 flange mounting (ISO 4401)

OML and OMM Orbital motors. Technical Information

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

MAKING MODERN LIVING POSSIBLE. Product overview. . Energy efficient. Reliable. Very long service intervals HIGH-PRESSURE SYSTEMS

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

Changing pistons APP 21-43

Axial Piston Fixed Motor A2FM

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Axial Piston Fixed Pump A17FNO Series 10

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass

Series 20 Axial Piston Pumps. Technical Information

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

PAHT / PAHT G pumps PAHT / PAHT G Disassembling and assembling

Axial piston fixed motor A2FM series 70. Americas. RE-A Edition:

External gear motor High Performance AZMB

Axial Piston Fixed Motor A10FM / A10FE (US-Version)

Variable Axial Piston Pump A10V Series - 52/53

2-Circuit Axial Piston Fixed Pump A18FDO

Series 20 Axial Piston Pumps. Technical Information

Vane pumps, direct controlled Type PV7...A

Axial piston fixed motor A2FM Series 70 A2FE Series 70

GM SERIES TECHNICAL CATALOG. Crankshaft Design Radial Piston Hydraulic Motors

E 068 E 088 In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min

Axial Piston Fixed Pump A17FNO

Automatic metal-edge filter AF 71 G

Changing pistons APP and APP 16-22

Axial Piston Fixed Pump A2FO

Oil Filter Module Pi 8300

Oil Filter Module Pi 8300

Fixed Displacement Pump A2FO

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

Automatic metal-edge filters AF 72 G

SCM M2. Other advantages:

Series TMM Axial Piston Motor. Technical Information

Truck Hydraulics. Serie VP1 Variable Displacement Pumps

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Axial piston variable pump (A)A4VSO

Return-Suction Filters E 158 E 198 E 248. Tank top mounting Connection up to -20 SAE Nominal flow rate up to 66 gpm us

Automatic metal-edge filter AF 73 G/AF 93 G

External Gear Pumps Series F

Displacement. (cc/rev) Tap Water Sea Water PC PV

Automatic filter AF 153 G

Axial Piston Variable Pump A2VK

THRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES

A10VO. Variable Displacement Piston Pump Technical Information Manual Module 3A

Flow sharing control block in mono block / sandwich plate design M6-22

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement

Truck Hydraulics. Series F1, F2, T1 Fixed Displacement Pumps

Vane motor high performance hydraulic series M5B - M5BS - M5BF

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design

Flow direction is reversed by tilting the swash plate to the opposite side of the neutral or zero displacement position.

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

Contents. Identification

MOTOR SCM M2

Fixed Displacement Motor AA2FM (A2FM)

Automatic filter AF 113 G

External gear pump Series G

Axial piston variable pump A7VO

Off-line Oil Filter Module Pi 8400

PUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar

Vane pump, direct operated

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

Return-Suction Filters E 068 E 088. In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min e

GMP-Type. Key Features: Integrated Motor-Pump Units

Automatic filter AF 173 G

VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

SCM ISO. SCM ISO is a range of robust axial piston motors especially suitable for mobile hydraulics.

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

Mobile Hydraulic Pumps T6G, T67G, T6ZC. Denison Vane Technology, fixed displacement

Fixed Displacement Motor A10FM A10FE

Orbital Motors Type OMP, OMR and OMH. Technical Information

Transcription:

DATA SHEET Sea Water Pump with Energy Recovery SWPE 1. General information The SWPE energy recovery unit consists of an APP pump and an motor, both connected to a double shafted electric motor. Energy recovery is obtained when high-pressure brine from the membranes is fed to the that converts the energy in the pressurized brine to mechanical energy to be re-used by the electric motor. As the has a fixed volumetric displacement, the recovery rate will be fixed. APP pumps and motors are designed to supply low viscosity and corrosive fluids under high pressure, eg. in seawater reverse osmosis filtration applications and for high pressure salt water pumping. The pumps and motors are based on the axial piston principle enabling a very light and compact design, and they are designed so that lubrication of the moving parts in the pumps and motors is provided by the fluid itself. No oil lubrication is thus required. All parts included in the pumps and motors are designed to provide long service life, i.e. long service life with a constantly high efficiency and minimum of service required. The pumps and motors are fixed displacement units in which the flow is proportional to the number of revolutions of the input shaft and the pump/motor displacement, regardsless of any counter-pressure. The electric motors are designed for driving equipment that requires continuous operation, and their high efficiency reduces energy consumption. Permeate Drain Pump Motor Feed 2. Benefits One of the smallest and lightest pumps/motors on the market. No preventive maintenance required (no periodic service like e.g. change of lubricant and wearing parts). Long service life. Danfoss guarantees 8000 hours maintenance-free operation. All parts of the pump and the motor are made of non corrosive materials eg. Duplex (SAF 220/EN1.4462/UNS S31803- S3220) and Super-duplex (SAF 207/EN1.4410/UNS S3270) stainless steel and carbon reinforced PEEK. High efficiency. The high efficiency of the electric motor saves money. 21B0889 DKCFN.PD.010.GA1.02 01-2007

3. Technical data APP pump / motor APP1.0/0.8 APP1./1.2 APP1.8/1.2 APP2./2.0 APP2./1.8 140 rpm Code number 180B8000 180B8002 180B8004 180B8006 180B8008 Feed flow m 3 /h (gpm) 0.0 (2.2) 0.80 (3.) 0.8 (3.7) 1.2 (.) 1.2 (.) Recovery rate % 29 28 32 29 32 Permeate (± 10%) m 3 /h (gpm) 0.14 (0.6) 0.22 (1.0) 0.27 (1.2) 0.36 (1.6) 0.40 (1.8) Electric motor (4 poles) 1.1 kw, IEC 90 1. kw, IEC 90 1. kw, IEC 90 2.2 kw, IEC 100 2.2 kw, IEC 100 2900 rpm Code number 180B8001 180B8003 180B800 180B8007 180B8009 Feed flow m 3 /h (gpm) 1.0 (4.6) 1. (6.8) 1.6 (7.3) 2. (11.2) 2. (11.2) Recovery rate % 29 28 32 29 32 Permeate (± 10%) m 3 /h (gpm) 0.30 (1.3) 0.43 (1.9) 0.2 (2.3) 0.74 (3.3) 0.82 (3.6) Electric motor (2 poles) 2.2 kw, IEC 90 3 kw, IEC 100 3 kw, IEC 100 * * If other flow or recovery rate is required, please contact Danfoss RO Solutions Sales Organization. * For this combination, please contact Danfoss RO Solutions Sales Organization. 4. Flow 1.20 Permeate production range 1.00 APP2./1.8 0.80 m 3 /h 0.60 APP1.8/1.2 0.40 APP1.0/0.8 0.20 0.00 00 1000 100 2000 200 3000 300 rpm Permeate production range 1.20 1.00 0.80 APP2./2.0 m 3 /h 0.60 0.40 APP1./1.2 0.20 0.00 00 1000 100 2000 200 3000 300 rpm 1 gpm = 3.79 l/min 1 l/min = 0.26 gpm 1 m 3 /h = 4.40 gpm 1 gpm = 0.23 m 3 /h Due to tolerances of both the pumps and the motors of an SWPE unit, permeate production will vary according to the figures above. 2 DKCFN.PD.010.GA1.02 21B0889

. Energy consumption vs. pressure A variation of up to 20% may occur depending on the rpm and the efficiencies of the pump and the motor. The curves below are calculated using an efficiency of the electric motor of 86% and provided that the pressure at the inlet of the motor is 1 bar less than the pressure from the APP pump. 4, APP1./1.2 APP1.0/0.8 APP2./2.0 APP1.8/1.2 APP2./1.8 kwh/m 3 kwh/m 3 4 3, 3 4 0 60 6 70 7 bar b ar 6. Power consumption SWPE unit APP1.0/0.8 APP1./1.2 APP1.8/1.2 APP2./2.0 APP2./1.8 Recovery rate (%) 29 28 32 29 32 kwh @ 0 bar (72 psi) 140 rpm 0.6 0.9 0.9 1.4 1. 0 bar (72 psi) 2900 rpm 1.2 1.7 1.9 2.8 3.0 60 bar (870 psi) 140 rpm 0.7 1.0 1.2 1.7 1. 60 bar (870 psi) 2900 rpm 1. 2.1 2.3 3.4 3. 70 bar (101 psi) 140 rpm 0.8 1.2 1.3 2.0 2.1 70 bar (101 psi) 2900 rpm 1.7 2.4 2.7 3.8 4.0 The figures in the table above are calculated using an efficiency of the electric motor of 86% and provided that the pressure at the inlet of the motor is 1 bar less than the pressure from the APP pump. 1 hp hr = 0.7 kwh 1 kwh = 1.34 hp hr 7. Pressure 7.1 Inlet pressure 7.1.1 APP pump: The pressure at the pump inlet (I) must be in the range: 0. - bar (7.3-72. psi). 7.1.2 motor: The pressure at the motor inlet (I) must be in the range: 10-80 bar (14-1160 psi). 7.2 Outlet pressure 7.2.1 APP pump: The pressure at the pump outlet (O) must be in the range: 20-80 bar (290-1160 psi). 7.2.2 motor: The pressure at the motor outlet (O) must be in the range: 0. - bar (7.3-72. psi) 21B0889 DKCFN.PD.010.GA1.02 3

8. Temperature and corrosion 8.1 Operation: Fluid temperature: +3 C to +0 C (+37.4 F to 122 F) - dependent on the NaCl concentration Ambient temperature: +3 C to +0 C (+37.4 F to 122 F) The chart below illustrates the corrosive resistance of different types of stainless steel related to NaCl concentration and temperature. All critical parts of the APP water pump and the water motor are made of SAF 207. If the APP/ are operated at high salinity, always flush the APP/ with fresh water at operation stop in order to minimise the risk of crevice corrosion. 904L / SAF 220 NaCl vs. temperature 8.2 Storage: Storage temperature: -40 C to +70 C (+37.4 F to 122 F) provided that the APP/ is drained of fluid and stored plugged. Antefreeze protection is required at temperatures below 2 C. Danfoss recommends using Dowcal N from Dow Chemical Company or Chillsafe mono propylene glycol from Arco Chemical Company. 9. Noise level The noise from the SWPE unit is typically less than 80 db(a). Generally, noise will be reduced if speed is reduced and vice versa. Use flexible hoses in order to minimize vibrations and noise. Since the pump/motor typically is mounted on a bell housing or frame, the noise level can only be determined for the complete unit (system). It is therefore very important that the pump/motor is mounted correctly on a frame with dampers to minimize vibrations and noise. The noise level is influenced by: The speed of the pump/motor, high rpm create more noise than low rpm Rigid mounting of the pump/motor generates more noise than flexible mounting Pipe mounting direct to the pump/motor increases the noise level compared to a flexible hose 10. Filtration As water has very low viscosity, the APP pumps / motors have been designed with very narrow clearance in order to control internal leakage rates and improve component performance. Therefore it is important that the inlet water is filtered properly to minimize the wear of the pump/motor. The main filter must have a filtration efficiency of 99.98% at 10 µm. We recommend that you use precision depth filter cartridges rated 10µm abs. ß10>000 (equivalent to a filtration efficiency of 99.98%). Bag filters and string wound filter cartridges typically have only 90% filtration efficiency. This means that for each 100,000 particles reaching the filter, 10,000 particles pass through it compared to only 20 particles in a filter with an efficiency of 99.98%. For more information on the importance of proper filtration, please consult our publication Filtration (code number 21B0861), which also will provide you with an explanation of filtration definitions and a guidance on how to select the right filter. 4 DKCFN.PD.010.GA1.02 21B0889

11. Dimensions 11.1 Pump/motor Description Pump Motor APP0.6 and APP1.0 0.8 and 1.2 APP1., APP1.8, APP2.2 and APP2. 1.8 and 2.0 C mm (in) Ø 88 (3.) Ø 10 (4.1) D mm (in) 131 (.2) 166 (6.) E Parallel key, DIN 688, mm (in) 20 (0.20 0.20 0.78) 20 (0.20 0.20 0.78) F Bleeding M6, Hexagon AF = mm M6, Hexagon AF = mm I Inlet connection Pump: BSP G½ ; 1 (0.9) deep Pump: BSP G¾ ; 1 (0.9) deep Motor: BSP G½ ; 1 (0.9) deep Motor: BSP G½ ; 17 (0.67) deep O Outlet connection Pump: BSP G½ ; 1 (0.9) deep Pump: BSP G½ ; 17 (0.67) deep Motor: BSP G½ ; 1 (0.9) deep Motor: BSP G¾ ; 1 (0.9) deep Pump/motor mounting flange SAE A 2 SAE A 2 21B0889 DKCFN.PD.010.GA1.02

11.2 Complete unit APP Pump/motor rpm A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) G (mm) H (mm) IEC Electric motor APP1.0/0.8 140 190 220 90 140 100 460 131 131 1.1 kw, IEC 90-4 APP1./1.2 140 190 220 90 140 12 460 166 131 1. kw, IEC 90-4 APP1.8/1.2 140 190 220 90 140 12 460 166 131 1. kw, IEC 90-4 APP2./2.0 140 210 240 100 160 140 60 166 166 2.2 kw, IEC 100-4 APP2./1.8 140 210 240 100 160 140 60 166 166 2.2 kw, IEC 100-4 APP1.0/0.8 2900 190 220 90 140 12 460 131 131 2.2 kw, IEC 90-2 APP1./1.2 2900 210 240 100 160 140 60 166 131 3 kw, IEC 100-2 APP1.8/1.2 2900 210 240 100 160 140 60 166 131 3 kw, IEC 100-2 12. Installation 12.1 Mounting The figure below illustrates how to mount the pump and the motor and connect them to electric motor/combustion engine. A: Flexible coupling B: Bell housing C: Motor shaft If alternative mounting is required, please contact Danfoss Sales Organization for further information. To ensure easy mounting of the flexible coupling without using tools, the tolerances must be dimensioned accordingly. Note: Any axial and/or radial loads on the shaft must be avoided, see User guide (21B0888). Permeate Drain Pump Motor Feed The pump/motor discharge should be connected to the rest of the plant with flexible high-pressure hoses. 6 DKCFN.PD.010.GA1.02 21B0889

13. System design The design of the system must ensure that self-emptying of the water motor during standstill is avoided. Always place the outlet line (drain) higher than the water motor. The outlet pressure of the water motor must never exceed the inlet pressure of the water motor. Air in the water will cause cavitation and damage the water pump and the water motor. 13.1 Membrane system with energy recovery and bleeding In order to eliminate the risk of damage and cavitation, observe the following guidelines: 1. For easy system bleeding without starting up the system, apply a bypass non-return valve (1) in parallel with the APP pump. 2. Place an inlet filter (2) in front of the APP pump (3). Please consult section 10, Filtration for guidance on how to select the right filter. Important: Thoroughly clean pipes and flush system prior to start-up - the APP pump and the must be bypassed. 3. Place a monitoring pressure switch (6) set at min. 1 bar between filter and pump inlet. The monitoring switch must stop the pump at pressures lower than 1 bar (14. psi). At 3000 rpm - use 2 bar (29 psi) as set point. 4. Dimension the inlet and outlet lines to obtain minimum pressure loss (large flow, minimum pipe length, minimum number of bends/connections, and fittings with small pressure losses).. Always maintain a positive pressure at the pump inlet (4) of min. 0. bar (7.3 psi) and max. bar (72. psi). At speeds above 3000 rpm the pressure at the inlet of the water pump must be min. 2 bar (29 psi). 6. Use flexible hoses () to minimize vibrations and noise. 7. Install a safety valve (7) in order to avoid system damage as the Danfoss APP pump creates pressure and flow immediately after start-up, despite any counter-pressure. 8. Always maintain a pressure at the motor inlet (8) of min. 10 bar (14 psi) and max. 80 bar (1160 psi). 9. As the pressure on the outlet line must not exceed bar, do not throttle the water motor outlet. 1 7 2 3 Feed 4 APP Permeate 6 M Outlet 8 Brine 13.2 Membrane system with energy recovery, bleeding and VFD In order to eliminate the risk of damage and cavitation, observe the following guidelines: 1. For easy system bleeding without starting up the system, apply a bypass non-return valve (1) in parallel with the APP pump. 2. Place an inlet filter (2) in front of the APP pump (3). Please consult section 10, Filtration for guidance on how to select the right filter. Important: Thoroughly clean pipes and flush system prior to start-up - the APP pump and the must be bypassed. 3. Place a monitoring pressure switch (6) set at min. 1 bar between filter and pump inlet. The monitoring switch must stop the pump at pressures lower than 1 bar (14. psi). At 3000 rpm - use 2 bar (29 psi) as set point. 4. Dimension the inlet and outlet lines to obtain minimum pressure loss (large flow, minimum pipe length, minimum number of bends/connections, and fittings with small pressure losses).. In order to eliminate the risk of damage and cavitation, a positive pressure at the pump inlet (4) is always to be maintained at min. 0. bar (7.3 psi) and max. bar (72. psi). At speeds above 3000 rpm the pressure at the inlet of the water pump must be min. 2 bar (29 psi). 6. Use flexible hoses () to minimize vibrations and noise. 7. Always maintain a pressure at the motor inlet (7) of min. 10 bar (14 psi) and max. 80 bar (1160 psi). 8. As the pressure on the outlet line must not exceed bar, do not throttle the water motor outlet. 9. Using a VFD (8) makes it possible to control the rotation speed, ramp up and ramp down of the electric motor. By altering the rotation speed, the permeate production can be changed to obtain optimum energy recovery. 10. Install a pressure transmitter (9) to measure the pressure at the membrane inlet. Use the signal from the pressure transmitter to obtain an automatic pressure-controlled adjustment of the VFD and optimum utilization and load of the membrane. 1 Feed 2 4 3 APP 9 Permeate 6 M 8 Outlet 7 VFD Brine 21B0889 DKCFN.PD.010.GA1.02 7

14. Service Provided that the pump/motor has been running according to the Danfoss specifications on pre-filtration, pressure, and rotation speed, Danfoss guarantees 8000 hours service-free operation, after which Danfoss recommends a pump/motor inspection where any worn parts must be replaced, in order to prevent a total and disastrous breakdown. Note: It is always recommended to replace pistons and shaft sealing if another service-free period is to be obtained. If the pistons are not replaced, more frequent inspection is recommended. The APP pump and the motor are made of duplex/super duplex materials with fine corrosion properties. However, it is always recommended to flush the pump/motor when the system is shut down. At high TDS and high water temperature, the service life of the shaft sealing will be reduced. For these applications it is recommended to replace the shaft sealing after approx. 4000 hours operation. 14.1 Periodic maintenance Water acts as lubricant in the APP/. Thus there is no oil in the the pump/motor. By operation below the curve for SAF 207 in the figure in section 8.1, no parts are expected to be replaced within the first 8000 hours of operation. It is recommended to inspect the internal parts of the after 4000 hours of operation, due to the high salinity of the received media. 14.2 Repair In case of irregular function of the APP/, please contact the Danfoss RO Solutions Sales Organisation. 8 DKCFN.PD.010.GA1.02 21B0889