Magnetic Drive Gear Pump

Similar documents
CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

CONTENTS INSTALLATION TECHNICAL SERVICE MANUAL TECHNICAL SERVICE MANUAL. General INSTALLATION, START UP, TROUBLESHOOTING,

TECHNICAL SERVICE MANUAL INSTALLATION, START UP, TROUBLESHOOTING, SERIES SG-04, SG-05 & SG-07 spur gear PUMPS

NECO Pumping Systems

TECHNICAL SERVICE MANUAL GENERAL PURPOSE JACKETED PUMPS SERIES 230 MODELS HX4, KK, LQ, Q, M, N

Model 1100 Turbine Flow Meter

TECHNICAL SERVICE MANUAL GENERAL PURPOSE BRACKET MOUNTED PUMPS SERIES 115 MODELS G, GX2, H and HX4

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

TECHNICAL SERVICE MANUAL

NECO Pumping Systems

MODEL 1100 TURBINE FLOW METER

Contents Project: Model: Chk d: Date:

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

VIKING SPUR GEAR SINGLE PUMPS SERIES SG-04, SG-05, SG-07 AND SGN-05, SGN-07 STANDARD CONSTRUCTION FEATURES

P-200 Plastic Utility Pump for Petroleum Products

SERIES 300V 115 and 230 VOLT AC FUEL TRANSFER PUMP Owner's Operation & Safety Manual Models FR300V, FR301V, FR310V & FR311V

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

FS Series INSTRUCTION AND MAINTENANCE MANUAL: FS SERIES SHEAR BLENDER. Sanitary Mixing and Blending Equipment

M-3025CB-AV Fuel Pump

INSTALLATION AND OPERATING

TECHNICAL SERVICE MANUAL

TITAN FLOW CONTROL, INC.

Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

OPERATION MANUAL INTERNAL GEAR PUMP. Models: NG-H, NG-HL, NG-K, NG-KK, NG-L, NG-LQ, NG-LL, NG-LS, NG-Q, NG-QS. Tel: Fax:

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

G8 Portable Fuel Transfer Pump Owner s Manual

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Solutions beyond products...

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

TECHNICAL SERVICE MANUAL HEAVY-DUTY BRACKET MOUNTED PUMPS SERIES 120 and SERIES 124 MODELS J, K, KK, L, LQ, LL AND LM

INSTALLATION AND OPERATING MANUAL

WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S

Installation, Operation & Maintenance Manual

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

SHURflo Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

INSTALLATION AND OPERATING MANUAL

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL HEAVY-DUTY PUMPS SERIES 332 AND 260 MODELS Q, M, N AND R

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

PPM EO-100 TM. Operation Manual

INSTALLATION AND SERVICE INSTRUCTIONS FOR 1008 AND 1010 SERIES PUMPS

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

A Series General Purpose Pumps General Purpose Pumps for Pressure Lubrication, Hydraulic Service, Fuel Supply and General Transfer

OWNER S MANUAL STOP. Models: Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof

Model GX Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

MODEL 900 IMPELLER-TYPE FLOW METER

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

BSM ROTARY GEAR PUMPS

Stealth Electronic Manual ZTM1015 Installation & Maintenance. For Oval Gear Meter Models:

PRODUCT OBSOLETED 1Q16

VIKING SG SERIES SEALLESS MAG DRIVE PUMPS

Positive Displacement Flowmeters GM020 series instruction manual

FIGURE 310AM, 310AMSW & 311AM 3-PIECE BALL VALVE

PeroxiDraw Dispenser

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Operation & Service Manual

MODEL 200 MULTI-JET FLOW METER

TITAN FLOW CONTROL, INC.

JET METER INSTRUCTIONS

Wastewater Combination Air Valve. Operation, Maintenance and Installation Manual

Read this entire manual before operation begins.

5874SS/5874PB/5874PBF/VRK5874/PBA6/ PBA6HPB/PBA7 Valve/Push Button

TECHNICAL SERVICE MANUAL

PRODUCT OBSOLETED 4Q16

FIXED DEPTH INSERTION METER INSTRUCTIONS

INLINE FOAM INDUCTOR HD FIRE PROTECT PVT. LTD. TECHNICAL DATA DESCRIPTION SPECIFICATION APPLICATION SYSTEM DESIGN DETAILS

Rotary Flow Meter SERVICE MANUAL*

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

8L SERIES THREE SCREW PUMPS

MR 5-30 Aviation Fuel Meter Owner s Manual

Series CP200. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. For Models: CP218 CP219 CP220 CP230

Models GP5132, GP5136, GP5142 & GP5145. Triplex Ceramic Plunger Pump Operating Instructions / Manual

Val-Matic QuadroSphere Trunnion Mounted Ball Valve

Electric Actuator Installation, Operation & Maintenance Manual

TECHNICAL SERVICE MANUAL

SERVICE MANUAL 200 SERIES MOTORIZED 20352, 20452, 20551, 20552, AND MODELS

FIGURE 310A & 311A 3-PIECE BALL VALVE

Please begin by checking that you have received all of the parts that come with your kit.

Vane Pumps. Single Stage Single and Double Vane Pumps. Vickers. Overhaul Manual

Reference Manual FM-200 Series

Read this entire manual before operation begins.

Read this entire manual before operation begins.

Positive Displacement Flowmeters GM007 series instruction manual

Caution. Do not operate your Micro Rain traveler without a serious overview of this manual. Keep children and unauthorized people away from traveler

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Read this entire manual before operation begins.

OPERATING INSTRUCTIONS ZDX 1/12CS

Model LP200, LP250 & LP250W-MT

DEMA 651AG SINGLE-FEED INSTALLATION INSTRUCTIONS

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Warner Electric UNIBRAKE Motor Brakes

PARTS AND INSTALLATION MANUAL

MODEL 10LH SPECIFICATION

SERVICE MANUAL 200 SERIES MOTORIZED 20352, 20452, 20551, 20552, AND MODELS

OPERATING INSTRUCTIONS ZDX 7-1/2AS

Transcription:

Magnetic Drive Gear Pump Installation / Operation Manual DF-A8-T DFS-A8-T DT-A7-T DT-A6-T Model Numbers Covered: DT-A8-T DTP-A7-T DTP-A6-T DTP-A8-T DTPS-A8-T DTS-A7-T DTS-A6-T DTS-A8-T SST-A7-T SST-A90-T SST-A6-T REV09/0/0 ADDITIVE SYSTEMS INC. 07 S. Main St Broken Arrow OK, 70 www.additivesystems.com -800--0 Since 98

Table Of Contents Page #...Overview...Features - Specifications...Magnetic Coupling - Pump Mounting 6...Rotation - Pressure Relief Valve 7...Piping 8...Typical Installation Illustration 9 & 0...Start up Checklist - Trouble Shooting -...Performance Curves...Warranty Pick the right pump for your application Standard Duty Ductile Iron High Pressure Heavy Duty SS Hammer Oxygenates X Dyes (i.e. diesel and product tracking) X Gasoline X Fuel Additives X Pipeline Sampling X Diesel X X Liquid Gas Products X Jet fuels X X Fertilizers X X Chemicals X Withstand static PSI up to 00 PSI X X X Withstand static PSI up to 00 PSI X PB-000 PP-C-0 PP-C-0 Optional Equipment Galvanized Pump Base Standard Outer Magnetic Coupling High Pressure Outer Magnetic Coupling Get Other Items From ASI Freestanding Rack Storage Tank ASCO Solenoid Valve Pressure Relief Valve Sight Guage Check Valves Thermal Relief Kit Ball Valve Swagolok Fittings

Operation The pumps covered in this manual are positive displacement, external gear, rotary pumps. These pumps use a synchronous magnetic coupling to transfer torque from the drive motor to the pump. This arrangement allows for the elimination of mechanical shaft seals. ASI pumps are built to precision tolerances from the fi nest materials. Every pump is performance tested before shipment. When properly installed and maintained it will give long and dependable Service. The following pages contain important information for proper Installation and operation. Theory Of Operation External gear pumps use two identical gears rotating against each other -- one gear is driven by a motor and it in turn drives the other gear. Each gear is supported by a shaft with bearings on each side of the gear. Theory Of Operation. As the gears come out of mesh, they create expanding volume on the inlet side of the pump. Liquid fl ows into the cavity and is trapped by the gear teeth as they rotate.. Liquid travels around the interior of the casing in the pockets between the teeth and the casing -- it does not pass between the gears.. Finally, the meshing of the gears forces liquid through the outlet port under pressure. Because the gears are supported on both sides, external gear pumps are quiet-running and are routinely used for high-pressure applications such as hydraulic applications. With no overhung bearing loads, the rotor shaft can t defl ect and cause premature wear.

FEATURES. Ductile Iron Construction - Standard. Carbon Graphite Bearings.. Balanced Magnetic Coupling.. Double - Sealed Containment Shell. All Tefl on Seals 6. * Consult ASI for speeds greater than 800 RPM Standard Duty Ductile Iron High Pressure Heavy Duty SS Hammer Port Connections Nominal Capacity @ 800 RPM DF-A8-T / 00# ANSI Flat Face Flange - 8 GPM DFS-A8-T / NPT - 8 GPM DT-A7-T ½ NPT - GPM DT-A6-T / NPT - GPM DT-A8-T / NPT - 8 GPM DTS-A7-T ½ NPT - GPM DTS-A6-T / NPT - GPM DTS-A8-T / NPT - 8 GPM DTP-A7-T ½ NPT - GPM DTP-A6-T / NPT - GPM DTP-A8-T / NPT - 8 GPM DTPS-A8-T / NPT - 8 GPM SST-A7-T ½ NPT - GPM SST-A90-T ½ NPT - GPM SST-A6-T / NPT - GPM Magnetic Coupling Do not attempt to drive or force coupling in place.after coupling is in place to dimension, secure to shaft with the two set screws. See page for Critical Mounting Dimension. Verify that the key does not extend into the open area inside the outer coupling, this will cause the key to rub the pumps containment shell. CAUTION: Do not install unattached coupling into pump housing. Magnetic force will make removal diffi cult. Inspect magnets for any metallic debris. Remove any foreign material. Place key into keyway slot on motor shaft. A light fi lm of Anti-Seize lubricant over the motor shaft will help prevent Corrosion. Slip coupling over shaft to the specifi ed dimension.(see page ) If coupling will not slip easily over shaft, it may be necessary to fi le off a small amount of material form two sides of the key. This is due to plating buildup in keyway of coupling.

NEMA 6C Motor Critical Mounting Dimension Failure to install the outer magnetic coupling at the proper distance of 9/6 from the face of the motor will severely hamper the life of your motor, pump, and magnetic coupling. While this critical dimension is easy to achieve, it is vital to the life of your equipment. Critical Dimension 9/6 Critical Pump To Motor Mounting CAUTION: Keep hands and fi ngers clear of mating surfaces when assembling pump to motor. Carefully guide pump and housing assembly over outer coupling toward motor. As coupling magnets align they will rapidly pull pump and motor assembly together. Secure housing to motor with the four () /8 socket head cap screws provided. Pump Mounting NEMA 6C Motor. Pump and motor assembly should be mounted securely to a solid base.. Mount pump as close to liquid supply as possible. Locate pump below liquid level. If possible. The better the suction conditions the better the pump will perform.

Rotation These pumps are designed for clockwise rotation. (Viewed from motor end of pump) Inlet Outlet NEMA 6C Motor Pressure Relief Valve All Pumps covered in this manual are positive displacement type and require an external pressure control valve rated for the pumps maxium fl ow rate in the discharge line. The pressure control valve provides over pressure protection for the pump and related piping. The control valve will also maintain correct operating pressure in the system. 6

Piping. Select piping equal to or larger than the port connections. Check inside of piping for debris.. Suction piping should be as short and direct as possible. Suction piping should be one size larger than the port size.. Install a strainer of adequate size in supply line. A supply of clean liquid is imperative for pump longevity. Select a strainer with a mesh size large enough not to restrict fl ow, but small enough to protect pump. Forty or sixty mesh screen is acceptable.. Install pressure control valve and pressure gauge in the discharge line.. The pressure gauge is necessary to monitor operating pressure and control valve setting. 6. Do not use the pump to support piping. Use hangers, stands or other means to support the piping. 7. Piping should fi t without imposing strain on the pump casing. Strain or distortion on the pump casing can cause mis-alignment and rapid wear of the pump components. 8. Pipe connections must be tight. Thread sealant and or tefl on tape will help eliminate leaks. If using tefl on tape be careful not to over tighten fi ttings causing damage. 7

8

Startup Check List Before starting pump check the following:. Control valve, pressure gauge and strainer are in place.. All pipe connections are tight.. Pump rotates freely.. All valves are open.. Motor rotation is correct. 6. Pump has adequate liquid supply. STARTUP After starting, pump should begin to deliver liquid within 0 to 0 seconds. If not, shut off pump and go through previous check list. TROUBLE SHOOTING If pump does not deliver liquid - probable causes:. Clogged strainer.. Rotation is reversed.. Valves are closed.. Air pockets or vapor locked.. Low tank level. 6. Pressure relief piston stuck or is set too low. 7. Suction lift too high. PUMP EXCESSIVELY NOISY PROBABLE CAUSES:. Vibration due to pump and / or piping mounting. Anchor mounting base and piping.. Pump cavitation or starved. Strainer clogged. Suction piping too small. Suction lift too high. Pump speed too high for viscosity of liquid. 9

PUMP CAPACITY LOW Probable causes:. Strainer clogged.. Air leaks in suction piping.. Motor running too slow.. Relief valve set too high.. Valves partially closed. 6. Excessive clearance in pump caused by corrosion or abrasives in liquid. CAUTION! Before servicing or removal of pump verify the following:. Liquid supply is shut off.. Liquid in the pump can be contained.. Drive motor has been disconnected or locked out. For service or parts please contact your distributor or ASI directly at: Additive Systems Inc. 07 S. Main Broken Arrow, OK. 70 Ph. -800--0 Fax 98--7 www.additivesystems.com 0

SST-A90-T BHP.80 A90 Performance Curve-8SSU 00 PSI.60 0 PSI.0 0 PSI.0 00 PSI 0 PSI 0 GPM.0 0 PSI 00 PSI.0.0 SST-A90-T Visc: Cps/8 SSU Based On: 0 inhgg 70 F,.9 SG 0 00 600 900 00 00 800 0 70 Pump Speed - RPM

SST-A90-T BHP.0 A90 Performance Curve-00SSU.0.0 00 PSI 00 PSI 00 PSI 00 PSI 00 PSI 0 GPM 6 00 PSI 00 PSI SST-A90-T Visc: 6. Cps/00 SSU Based On: 0 inhgg 70 F,.9 SG 0 00 000 00 000 00 Pump Speed - RPM 000

SST-A90-T BHP A90 Performance Curve-700SSU 00 PSI 00 PSI 00 PSI 00 PSI 00 PSI 0 GPM 6 00 PSI 00 PSI DT-A90-T Visc: 8. Cps/700 SSU Based On: 0 inhgg 70 F,.9 SG 0 70 00 0 000 70 0 70 0 Pump Speed - RPM

DT-A7-T / DTP-A7-T / DTS-A7-T / SST-A7-T BHP A7 Series Pump Performance Curve-8SSU.80.60.0.0 00 PSI 0 PSI 00 PSI 0 PSI 00 PSI 7 PSI 0 PSI 0 GPM.0.0 0 PSI 00 PSI 00 PSI.0 Visc: Cps/8 SSU Based On: 0 inhgg 70 F,.9 SG 0 00 600 900 00 00 800 0 70 Pump Speed - RPM

DT-A7-T / DTP-A7-T / DTS-A7-T / SST-A7-T BHP.0 A7 Series Pump Performance Curve-00SSU.0.0 0 GPM 6 00 PSI 00 PSI 00 PSI 0 PSI 00 PSI 0 PSI 7 PSI 00 PSI 00 PSI Visc: 6. Cps/00 SSU Based On: 0 inhgg 70 F,.9 SG 0 70 00 0 000 70 0 70 0 Pump Speed - RPM

DT-A7-T / DTP-A7-T / DTS-A7-T / SST-A7-T BHP A7 Series Pump Performance Curve-700SSU 00 PSI 00 PSI 00 PSI 00 PSI 00 PSI 0 GPM 6 00 PSI 00 PSI Visc: 8. Cps/700 SSU Based On: 0 inhgg 70 F,.9 SG 0 70 00 0 000 70 0 70 0 Pump Speed - RPM 6

DT-A6-T / DTP-A6-T / DTS-A6-T / SST-A6-T BHP.0 A6 Series Pump Performance Curve-8SSU 00 PSI.0.0 0 GPM 6 0 PSI 00 PSI 0 PSI 00 PSI 7 PSI 0 PSI 0 PSI 00 PSI 00 PSI 00 PSI Visc: Cps/8 SSU Based On: 0 inhgg 70 F,.9 SG 0 00 600 900 00 00 800 0 70 Pump Speed - RPM 7

DT-A6-T / DTP-A6-T / DTS-A6-T / SST-A6-T BHP A6 Series Pump Performance Curve-00SSU 0 GPM 0 00 PSI 00 PSI 00 PSI 0 PSI 00 PSI 0 PSI 7 PSI 00 PSI 00 PSI 8 6 Visc: 6. Cps/00 SSU Based On: 0 inhgg 70 F,.9 SG 0 70 00 0 000 70 0 70 0 Pump Speed - RPM 8

DT-A6-T / DTP-A6-T / DTS-A6-T / SST-A6-T BHP A6 Series Pump Performance Curve-700SSU 00 PSI 00 PSI 00 PSI 00 PSI 00 PSI 0 GPM 6 00 PSI 00 PSI Visc: 8. Cps/700 SSU Based On: 0 inhgg 70 F,.9 SG 0 00 600 900 00 00 800 0 70 Pump Speed - RPM 9

DF-A8-T / DFS-A8-T / DT-A8-T / DTP-A8-T DTPS-A8-T / DTS-A8-T BHP A8 Series Pump Performance Curve-8SSU.80 00 PSI.60.0 7 PSI 0 PSI.0 0 GPM 6 0 PSI 7 PSI 00 PSI Visc: Cps/8 SSU Based On: 0 inhgg 70 F,.9 SG 0 00 600 900 00 00 800 0 70 Pump Speed - RPM 0

DF-A8-T / DFS-A8-T / DT-A8-T / DTP-A8-T DTPS-A8-T / DTS-A8-T BHP A8 Series Pump Performance Curve-00SSU 00 PSI 0 GPM.0 00 PSI 0 PSI 00 PSI 0 PSI 7 PSI 0 PSI 00 PSI 00 PSI 0 7.0.0 Visc: 6. Cps/00 SSU Based On: 0 inhgg 70 F,.9 SG 0 70 00 0 000 70 0 70 0 Pump Speed - RPM

DF-A8-T / DFS-A8-T / DT-A8-T / DTP-A8-T DTPS-A8-T / DTS-A8-T BHP A8 Series Pump Performance Curve-700SSU 00 PSI 00 PSI 00 PSI 7 PSI 0 GPM 0 8 6 00 PSI 00 PSI Visc: 8. Cps/700 SSU Based On: 0 inhgg 70 F,.9 SG 0 00 600 900 00 00 800 0 70 Pump Speed - RPM

ASI Pump Warranty Additive Systems Inc. warrants pumps manufactured by ASI to be free from defects in workmanship or material for a period of one () year* from date of startup, provided that in no event shall this warranty extend more than eighteen (8) months form the date of sale. Pumps manufactured by ASI carry a no-leak guarantee which extends for three () years from date of purchase. If during said warranty period, a pump proves to be defective in workmanship or material under normal* use and service, and if such products are returned to ASI in Broken Arrow, Oklahoma, transportation charges prepaid, and if the product is found by ASI to be defective in workmanship or material, they will be replaced or repaired free of charge, F.O.B. Broken Arrow, OK. *Pumps utilized for other than normal service, will be warranted for a period of ninety (90) days from date of startup. Please reference the chart on page to identify the right pump for your application. ASI assumes no liability for consequential damages of any kind and purchaser by acceptance of delivery assumes all liability for the consequences of the use or misuse of ASI products by the purchaser, his employees or others. ASI will assume no field expense for service or parts unless written authorization for it is received in advance. This is ASI s sole warranty and is in lieu of all other warranties, expressed or implied, which are hereby excluded, including in particular all warranties of merchantability or fi tness for a particular purpose. No offi cer or employee of Additive Systems Inc. is authorized to alter this warranty. Serial Number Serial Number Serial Number Serial Number Date Installed Date Installed Date Installed Date Installed

Products Custom fabricate to your spec in steel, aluminum, SS, etc. Industrial, commercial, agricultural, residential Gasoline, Diesel, Biodiesel, CNG, Ethanol, Jet, Water, Crude Oil, Natural Gas Liquids, Mercaptan, etc. Turnkey Truck Racks, Blending Skids, Metering Skids High Pressure Sampling Pumps Leak-Free Magnetically-Coupled Gear Pumps SS Hammer Industrial Duty Magnetically-Coupled Pumps Tanks built to virtually any size OSHA Standards, NFPA Specifi cations Custom Vent Hatches Specialty Breathers Desiccant Filters Additive Monitoring and Management Systems Custom containment pans Ladders, Platforms, Cages Mechanical Gauges Red-line Tank Gauges Service Turnkey Installation of Additive Equipment Quality Preventative Maintenance Programs Complete System Calibration Retrofi t Installation of existing equipment General Maintenance Complete Engineering/CAD Services Systems Replacement and Upgrades Over 0 Years Combined Employee Experience Guarantee the Job Is Done Right Tailored jobs for specifi c requirements Maintenance checks on your injection system: monthly/quarterly/annual