U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

Similar documents
U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: SS 145.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: SPECIALTY WHOLESALE SUPPLY

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: CR LAURENCE CO., INC.

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS CORPORATION

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: EARTHWISE GROUP, L.L.C

AAMA THERMAL PERFORMANCE REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 3150 Curtain Wall TYPE: Glazed Wall System

AAMA THERMAL PERFORMANCE REPORT (Revised) Rendered to: UNITED STATES ALUMINUM

COMPUTER SIMULATION U-FACTOR, SHGC, VT PERFORMANCE EVALUATION OF FIXED WINDOW 3000 SERIES LOW PROFILE FIXED. Dominion Doors & Windows Ltd.

AAMA THERMAL PERFORMANCE REPORT. Rendered to: TORO ALUMINUM. SERIES/MODEL: Commdoor 225 Awning (Project Out) TYPE: Projecting, Awning

AAMA THERMAL PERFORMANCE REPORT. Rendered to: TUBELITE, INC. SERIES/MODEL: 200 Series Curtainwall (E2297) TYPE: Glazed Wall System

COMPUTER SIMULATION U-FACTOR, SHGC, VT PERFORMANCE EVALUATION OF FIXED WINDOW 3000 SERIES CASEMENT WINDOW. Dominion Doors & Windows Ltd.

AAMA THERMAL PERFORMANCE REPORT. Rendered to: US ALUMINUM INC., DIVISION OF CR LAURENCE CO., INC.

Performance Data and Comparisons

8400 SERIES THERMAL PERFORMANCE CHART

Notice of Product Certification Authorization

BS EN ISO :2006

NFRC Product Certification Authorization Report

Product Guide Specification

CHAPTER 3 INTEGRITY WOOD ULTREX DOUBLE HUNG

3948 Townsfair Way, Suite 200 July 2013 Columbus, Ohio Toll Free Website

Sliding Patio Doors Builders Vinyl

General Information SECTION DIRECTORY

Modern Aluminum COLLECTION

Manufacturer s Certification Ply Gem Replacement Windows

LUXURY SLIDING PATIO & SWINGING FRENCH DOORS

Sliding Patio Doors Flat Casing Vinyl

Guide Specification SECTION VINYL WINDOWS

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Product Guide Specification

Double Hung. Power Lift 28,000 Constant Force

your vision, our windows

Solarban 70XL and Solarban 70XLVT Coated Glass Technical Considerations and Guidelines

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

Pella Impervia 350 Series Vinyl Awning Windows and Sliding Patio Doors

CONSTRUCTION CONSULTING LABORATORY, INTERNATIONAL

Specifications... Quick Spec Guide...

Weather Shield Thermal Performance Criteria

Product Selection Guide Size and Performance Data...W-HG-2 Features and Options...W-HG-3 Combination Assemblies...W-HG-4 Glazing Performance...

New $1500 Stimulus Plan Tax Credit

SIZE AND PERFORMANCE SUMMARY GLAZING PERFORMANCE GRILLE PROFILES AND PATTERNS SIZE TABLES DESIGN DATA DETAILED PRODUCT DESCRIPTION CROSS SECTIONS

Architect Series Traditional

Visions 2000 Double Hung Tilt Window Parts Reference Catalog

HURRICANESHIELD IMPACT-RESISTANT GLASS SECTION DIRECTORY. Size and performance summary. Glazing performance. Grille profiles and patterns.

SIZE AND PERFORMANCE SUMMARY GLAZING PERFORMANCE GRILLE PROFILES AND PATTERNS SIZE TABLES DESIGN DATA DETAILED PRODUCT DESCRIPTION CROSS SECTIONS

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Architectural Manual. Vinyl Windows & Patio Doors

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

VINYL WINDOWS & DOORS

Warranty, Parts & Install Info 1. Series 4600 Double Hung Windows 2. Series 4710 Casement Windows 3. Series 9000 Sliding Patio Door 4

Sliding Windows Brickmould Vinyl

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

V3 Series Awning Windows (2011 to Present)

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

SINGLE SLIDING WINDOW 1000 SERIES 4-1/2" FRAME SINGLE SLIDER LIFT OUT

Casement Windows Builders Clad-Wood

Intelligent Design. Superior Performance.

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

Lifestyle Series Casement

W i n d j a m m e r S e r i e s 4 0 Change Your Outlook

2000T TERRACE DOOR. Features

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Pella 450 Series. Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data

Meeting ENERGY STAR Version 6.0

AAMA/WDMA/CSA 101/I.S.2/A440-08

SLIDING DOOR AND WINDOW SYSTEM WITH THERMAL BREAK

AAMA/WDMA/CSA 101/I.S.2/A440-08

GOLD LABEL CERTIFICATION

ECOSTAR and MAXGREEN

Siteline Clad Swinging Patio Doors Premium Wood

Gliding Windows Premium Vinyl

Series A L L - E N V I R O N M E N T V I N Y L W I N D O W S S T R E N G T H P E R F O R M A N C E E F F I C I E N C Y

6100 SERIES SINGLE HUNG

Architect Series Traditional

Pella 250 Series. Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data

Series A L L - E N V I R O N M E N T V I N Y L W I N D O W S S T R E N G T H P E R F O R M A N C E E F F I C I E N C Y

Meeting Residential Energy Requirements with Wood-Frame Construction

81870 Alside_24667 Alside 11/3/16 5:01 PM Page 2 80 Series

AAMA/WDMA/CSA 101/I.S.2/A NAFS North American Fenestration Standard/Specification for windows, doors, and skylights

Residential skylight sizes 2008 edition

DF COLLECTION. Architectural Detail Guide Hybrid Awning Window DF 3113 TABLE OF CONTENTS

350/500 Tuffline TM Entrances 1

Single-Hung Windows Premium Atlantic Vinyl

Ambassador ALUMINUM WINDOWS & DOORS FOR ALL SEASONS

Primed Epicr Radius and Geometric Windows - In-Sash Custom Wood

Neat Coated Glass. TECHNICAL SERVICE BULLETIN Bulletin #CG04 01/16

350/500 Heavy Wall TM Entrances 1

SIZE AND PERFORMANCE SUMMARY GLAZING PERFORMANCE GRILLE PROFILES AND PATTERNS SIZE TABLES DESIGN DATA DETAILED PRODUCT DESCRIPTION CROSS SECTIONS

Aluminum Wood Double-Hung Windows

StyleGuard IMPACT- When the storm is at its worst, our performance is at its best. RESISTANT WINDOWS DOORS AND

Siteline EX Clad Casement Windows Premium Wood

Architect Series Designer Series Pella ProLine. Architect Series...AW-1 Designer Series...AW-2 Pella ProLine...AW-2

Contents. Preface 6. 1 Scope General Outside of scope Terminology Units of measurement 13 1.

Elaine Sagers, Vice President Pella Corporation, January 18, 2016

Transcription:

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report REPORT NO: NCTL-110-16086-01 SIMULATION DATE: 08/30/13 REPORT DATE: 08/30/13 Client: Product Line: Specification: Procedures and Compliance: Northeast Windows USA, Inc. P.O. Box 159 Merrick, NY 11566 Northeast Windows USA, Inc. s 400 Vinyl Patio Door. NFRC 100-2010: Procedure for Determining Fenestration Product U-Factors. NFRC 200-2010: Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence. NFRC 500-2010: Procedure for Determining Fenestration Product Condensation Resistance Values. Therm 6.x / Window 6.x NFRC Simulation Manual (Approved at test date) All U-factor, Solar Heat Gain Coefficients, Visible Transmittance and Condensation Resistance values were calculated using the following characteristics: a default value of 0.30 solar absorptance for all products other than window glazed wall and sloped glazing which have a solar absorptance of 0.50. The best glazing option was used as the configuration for SHGC and VT specialty products table. NCTL is a NFRC accredited simulation laboratory and this simulation was conducted in full compliance with NFRC requirements. This report does not constitute an opinion or endorsement by the laboratory. Ratings values included in this report are for submittal to an NFRC-licensed IA and are not meant to be used directly for labeling purposes. Only those values identified on a valid Certification Authorization Report (CAR) by an NFRC accredited Inspection Agency (IA) are to be used for labeling purposes. Rounding per NFRC 601-2010: NFRC Unit and Measurement Policy. PRODUCT LINE DESCRIPTION General: The product line modeled is Northeast Windows USA, Inc.'s 400 Vinyl Patio Door.. Model Size Simulations: 2000mm x 2000mm (78.740 x 78.740 ) PROFESSIONALS IN THE SCIENCE OF TESTING

Northeast Windows USA, Inc. NCTL-110-16086-01 Weatherseals: Location Left Head Left Jamb Left Sill Meeting Stile Right Head Right Jamb Right Sill Weather Seal Description (2) single strips of weather-strip (2) single strips of weather-strip (2) single strips of weather-strip (2) single strips of weather-strip (2) single strips of weather-strip (2) single strips of weather-strip (2) single strips of weather-strip Gas Fillings: Reinforcement: Not applicable. Gas Type Filling Technique Percentage Argon Single probe 90% Argon Double probe 95% Edge of - Glass Construction: Exterior vinyl glazing bead with an interior foam tape back bedding. Finish: Vinyl Frame Description: Code Type Definition VY Vinyl All members are vinyl with no reinforcements Sash Description: Code Type Definition VV Vinyl w/ Vertical Members Reinforced Reinforcement of vertical members Spacer and Sealant: Code Type Definition A8-S Aluminum-Butyl Composite Exposed corrugated aluminum spacer with butyl P1-S Polycarbonate- Butyl Exposed corrugated polycarbonate spacer with butyl - single Composite sealed. ZE-D Elastomeric Silicone Foam Elastomeric Silicone foam spacer system

Northeast Windows USA, Inc. NCTL-110-16086-01 Dividers: Where applicable, dividers were not modeled because the gap between dividers and lites were greater than 3mm. For Solar Heat Gain and Visual Light Transmittance default dividers less than 1 and greater or equal to 1 and default patterns were used for simulations. Divider Description: 3/16 x 5/8 Painted Aluminum Rectangular. Group Leaders: The following group leaders are actual simulated individual products per NFRC 4.2.4 and the NFRC Technical Interpretations where applicable. All remaining individual products' U-factors in the corresponding groups are represented by the group leader's U-factor. COG Group Leader: Determined by NFRC 100-2010 Section 4.2.4.1 (Only the Group Leader is shown). * Group Leader Glazing ID Glazing Description U COG 001 2m_Clear_Air 0.485 005 2m_SB70#2_Air 0.301 013 2m_366#2_Arg 0.254 015 2m_SB70#2_Arg95_EPS#4 0.195 019 2m_Select36#2_Air 0.308 021 2m_Select36#2_Arg 0.260 024 2m_SB70#2_Arg95_EPS#4_875 0.201 Modeling Assumptions and Comments Deemed Important: Sealing Rules: All cavities that are opened to the exterior within a frame section shall be modeled according to ISO 15099, Section 6.7.1, which states that cavities greater than 2mm but equal to or less than 10 mm shall be modeled as slightly ventilated air cavities. For physical testing purposes the product is sealed at the inside surface with tape or equivalent to prevent air infiltration. Air cavities created by this sealing technique must be simulated with the standard NFRC Frame Cavity material. If cavities on the frame are sealed (covered) to the surround panel with tape or equivalent, those cavities are also filled with NFRC Frame Cavity material within the simulation model. If the frame is not covered or sealed, those areas are left hollow or opened within the simulation model. Continuous elements: All elements continuous within the product line are identified from the Bill-of-Materials and detailed drawings via the referenced dimensions and cut lengths as compared to the overall size of the product. General Notes: The Condensation Resistance results obtained from this procedure are for controlled laboratory conditions and do not include the effects of air movement through the specimen, solar radiation, and the thermal bridging that may occur due to the specific design and construction of the fenestration system opening.

Northeast Windows USA, Inc. NCTL-110-16086-01 Miscellaneous assumptions: 1. The screen extrusions were not modeled. 2. All radii are simulated at angles. 3. The modeling was performed in accordance with the manufacturer s assembly drawing. Component Area and Frame Heights: Frame heights, calculated areas, area weighted values for U-factor, SHGC, and VT, and center of-glazing are located in approved NFRC simulation programs for all individual products. NCTL Therm Section Filename Methodology Filename Codes Example: HD-CU-D-F1_003.THM HD Frame Section (Head) CU-D Spacer (Intercept) F1 Frame Description _003 Glazing ID #3

PRODUCT Product Number Pane ID #1 Pane ID #2 Pane ID #3 Pane ID #4 Pane Thickness #1 Pane Thickness #2 Pane Thickness #3 Pane Thickness #4 Gap 1 Gap 2 Gap 3 Gap Fill 1 Gap Fill 2 Gap Fill 3 % of Gap Fill 1 % of Gap Fill 2 % of Gap Fill 3 Emissivity Surface 1 Emissivity Surface 2 Emissivity Surface 3 Emissivity Surface 4 Emissivity Surface 5 Emissivity Surface 6 1 2mm Clear 2mm Clear 0.090 0.090 0.678 AIR CL A8-S N,G 0.75 0.45 44 2mm Clear/AIR/2mm Clear 0.60 0.52 NA 0.62 0.54 NA 3mm Clear 3mm Clear 0.117 0.117 0.639 AIR CL A8-S N,G 0.75 0.45 44 3mm Clear/AIR/3mm Clear 0.58 0.51 NA 0.61 0.54 NA Emissivity Surface 7 Emissivity Surface 8 Tint Spacer Grid Type Grid Size U-factor Condensation Resistance PRODUCT BY GLAZING SHGC NO GRID SHGC GRID<1" SHGC GRID>=1" VT NO GRID VT GRID<1" VT GRID >=1" 2 2mm ClimaGuard RLE 71/38 2mm Clear 0.090 0.090 0.678 AIR 0.027 CL A8-S N,G 0.75 0.32 55 2mm ClimaGuard RLE 71/38/AIR/2mm Clear 0.30 0.26 NA 0.53 0.47 NA 2mm ClimaGuard RLE 71/38 3mm Clear 0.117 0.117 0.639 AIR 0.027 CL A8-S N,G 0.75 0.32 55 2mm ClimaGuard RLE 71/38/AIR/3mm Clear 0.30 0.26 NA 0.53 0.46NA 2mm Solarban 70XL 2mm Clear 0.089 0.090 0.678 AIR 0.018 CL A8-S N,G 0.75 0.32 55 2mm Solarban 70XL/AIR/2mm Clear 0.21 0.19 NA 0.49 0.42 NA 3mm Solarban 70XL 3mm Clear 0.129 0.117 0.639 AIR 0.018 CL A8-S N,G 0.75 0.32 55 3mm Solarban 70XL/AIR/3mm Clear 0.21 0.19 NA 0.48 0.42 NA 3 2mm Solarban 70XL 2mm Clear 0.089 0.090 0.678 ARG 90 0.018 CL A8-S N,G 0.75 0.29 58 2mm Solarban 70XL/ARG/2mm Clear 0.21 0.18 NA 0.49 0.42 NA 3mm Solarban 70XL 3mm Clear 0.129 0.117 0.639 ARG 90 0.018 CL A8-S N,G 0.75 0.29 58 3mm Solarban 70XL/ARG/3mm Clear 0.21 0.18 NA 0.48 0.42 NA 2mm LoE 366 2mm Clear 0.087 0.090 0.678 ARG 90 0.022 CL A8-S N,G 0.75 0.29 58 2mm LoE 366/ARG/2mm Clear 0.21 0.18 NA 0.49 0.43 NA 4 3mm LoE 366 3mm Clear 0.117 0.117 0.639 ARG 90 0.022 CL A8-S N,G 0.75 0.24 48 3mm LoE 366/ARG/3mm Clear 0.21 0.18 NA 0.48 0.42 NA 2mm Solarban 70XL 2mm Comfort E-PS 0.089 0.087 0.553 ARG 95 0.018 0.148 OT A8-S N,G 0.75 0.24 48 2mm Solarban 70XL/ARG/2mm Comfort E-PS 0.20 0.18 NA 0.45 0.40 NA 3mm Solarban 70XL 3mm Comfort E-PS 0.129 0.123 0.514 ARG 95 0.018 0.148 OT A8-S N,G 0.75 0.24 48 3mm Solarban 70XL/ARG/3mm Comfort E-PS 0.20 0.17 NA 0.44 0.38 NA 2mm LoE 366 2mm Comfort E-PS 0.087 0.087 0.553 ARG 95 0.022 0.148 OT A8-S N,G 0.75 0.24 48 2mm LoE 366/ARG/2mm Comfort E-PS 0.20 0.18 NA 0.46 0.40 NA 3mm LoE 366 3mm Comfort E-PS 0.117 0.123 0.514 ARG 95 0.022 0.148 OT A8-S N,G 0.75 0.24 48 3mm LoE 366/ARG/3mm Comfort E-PS 0.20 0.17 NA 0.44 0.38 NA 5 2mm Comfort Select 36 2mm Clear 0.087 0.090 0.678 AIR 0.037 CL A8-S N,G 0.75 0.33 54 2mm Comfort Select 36/AIR/2mm Clear 0.28 0.25 NA 0.50 0.44 NA 3mm Comfort Select 36 3mm Clear 0.129 0.117 0.639 AIR 0.036 CL A8-S N,G 0.75 0.33 54 3mm Comfort Select 36/AIR/3mm Clear 0.28 0.25 NA 0.49 0.43 NA 2mm Comfort Select 36 2mm Clear 0.087 0.090 0.678 ARG 90 0.037 CL A8-S N,G 0.75 0.33 54 2mm Comfort Select 36/ARG/2mm Clear 0.28 0.25 NA 0.50 0.44 NA 6 2mm Comfort Select 36 2mm Clear 0.087 0.090 0.678 AIR 0.037 CL A8-S N,G 0.75 0.29 57 2mm Comfort Select 36/AIR/2mm Clear 0.28 0.25 NA 0.50 0.44 NA 3mm Comfort Select 36 3mm Clear 0.129 0.117 0.639 AIR 0.036 CL A8-S N,G 0.75 0.29 57 3mm Comfort Select 36/AIR/3mm Clear 0.28 0.25 NA 0.49 0.43 NA 2mm Comfort Select 36 2mm Clear 0.087 0.090 0.678 ARG 90 0.037 CL A8-S N,G 0.75 0.29 57 2mm Comfort Select 36/ARG/2mm Clear 0.28 0.25 NA 0.50 0.44 NA 7 3mm Comfort Select 36 3mm Clear 0.129 0.117 0.639 ARG 90 0.036 CL A8-S N,G 0.75 0.25 49 3mm Comfort Select 36/ARG/3mm Clear 0.28 0.24 NA 0.49 0.43 NA 3mm Comfort Select 28 3mm Comfort E-PS 0.125 0.123 0.514 ARG 95 0.029 0.148 OT A8-S N,G 0.75 0.25 49 3mm Comfort Select 28/ARG/3mm Comfort E-PS 0.20 0.18 NA 0.42 0.37 NA 2mm Solarban 70XL 2mm Comfort E-PS 0.089 0.087 0.678 ARG 95 0.018 0.148 OT A8-S N,G 0.75 0.25 49 2mm Solarban 70XL/ARG/2mm Comfort E-PS 0.20 0.18 NA 0.45 0.40 NA 8 2mm Clear 2mm Clear 0.090 0.090 0.678 AIR CL P1-S N,G 0.75 0.45 46 2mm Clear/AIR/2mm Clear 0.60 0.52 NA 0.62 0.54 NA 3mm Clear 3mm Clear 0.117 0.117 0.639 AIR CL P1-S N,G 0.75 0.45 46 3mm Clear/AIR/3mm Clear 0.58 0.51 NA 0.61 0.54 NA 9 2mm ClimaGuard RLE 71/38 2mm Clear 0.090 0.090 0.678 AIR 0.027 CL P1-S N,G 0.75 0.32 59 2mm ClimaGuard RLE 71/38/AIR/2mm Clear 0.30 0.26 NA 0.53 0.47 NA 2mm ClimaGuard RLE 71/38 3mm Clear 0.117 0.117 0.639 AIR 0.027 CL P1-S N,G 0.75 0.32 59 2mm ClimaGuard RLE 71/38/AIR/3mm Clear 0.30 0.26 NA 0.53 0.46NA 2mm Solarban 70XL 2mm Clear 0.089 0.090 0.678 AIR 0.018 CL P1-S N,G 0.75 0.32 59 2mm Solarban 70XL/AIR/2mm Clear 0.21 0.19 NA 0.49 0.42 NA 3mm Solarban 70XL 3mm Clear 0.129 0.117 0.639 AIR 0.018 CL P1-S N,G 0.75 0.32 59 3mm Solarban 70XL/AIR/3mm Clear 0.21 0.19 NA 0.48 0.42 NA 10 2mm Solarban 70XL 2mm Clear 0.089 0.090 0.678 ARG 90 0.018 CL P1-S N,G 0.75 0.28 62 2mm Solarban 70XL/ARG/2mm Clear 0.21 0.18 NA 0.49 0.42 NA 3mm Solarban 70XL 3mm Clear 0.129 0.117 0.639 ARG 90 0.018 CL P1-S N,G 0.75 0.28 62 3mm Solarban 70XL/ARG/3mm Clear 0.21 0.18 NA 0.48 0.42 NA 2mm LoE 366 2mm Clear 0.087 0.090 0.678 ARG 90 0.022 CL P1-S N,G 0.75 0.28 62 2mm LoE 366/ARG/2mm Clear 0.21 0.18 NA 0.49 0.43 NA 11 3mm LoE 366 3mm Clear 0.117 0.117 0.639 ARG 90 0.022 CL P1-S N,G 0.75 0.24 51 3mm LoE 366/ARG/3mm Clear 0.21 0.18 NA 0.48 0.42 NA 2mm Solarban 70XL 2mm Comfort E-PS 0.089 0.087 0.553 ARG 95 0.018 0.148 OT P1-S N,G 0.75 0.24 51 2mm Solarban 70XL/ARG/2mm Comfort E-PS 0.20 0.18 NA 0.45 0.40 NA 3mm Solarban 70XL 3mm Comfort E-PS 0.129 0.123 0.514 ARG 95 0.018 0.148 OT P1-S N,G 0.75 0.24 51 3mm Solarban 70XL/ARG/3mm Comfort E-PS 0.20 0.17 NA 0.44 0.38 NA 2mm LoE 366 2mm Comfort E-PS 0.087 0.087 0.553 ARG 95 0.022 0.148 OT P1-S N,G 0.75 0.24 51 2mm LoE 366/ARG/2mm Comfort E-PS 0.20 0.18 NA 0.46 0.40 NA 3mm LoE 366 3mm Comfort E-PS 0.117 0.123 0.514 ARG 95 0.022 0.148 OT P1-S N,G 0.75 0.24 51 3mm LoE 366/ARG/3mm Comfort E-PS 0.20 0.17 NA 0.44 0.38 NA 12 2mm Comfort Select 36 2mm Clear 0.087 0.090 0.678 AIR 0.037 CL P1-S N,G 0.75 0.32 58 2mm Comfort Select 36/AIR/2mm Clear 0.28 0.25 NA 0.50 0.44 NA 3mm Comfort Select 36 3mm Clear 0.129 0.117 0.639 AIR 0.036 CL P1-S N,G 0.75 0.32 58 3mm Comfort Select 36/AIR/3mm Clear 0.28 0.25 NA 0.49 0.43 NA 2mm Comfort Select 36 2mm Clear 0.087 0.090 0.678 ARG 90 0.037 CL P1-S N,G 0.75 0.32 58 2mm Comfort Select 36/ARG/2mm Clear 0.28 0.25 NA 0.50 0.44 NA 13 2mm Comfort Select 36 2mm Clear 0.087 0.090 0.678 AIR 0.037 CL P1-S N,G 0.75 0.29 62 2mm Comfort Select 36/AIR/2mm Clear 0.28 0.25 NA 0.50 0.44 NA 3mm Comfort Select 36 3mm Clear 0.129 0.117 0.639 AIR 0.036 CL P1-S N,G 0.75 0.29 62 3mm Comfort Select 36/AIR/3mm Clear 0.28 0.25 NA 0.49 0.43 NA 2mm Comfort Select 36 2mm Clear 0.087 0.090 0.678 ARG 90 0.037 CL P1-S N,G 0.75 0.29 62 2mm Comfort Select 36/ARG/2mm Clear 0.28 0.25 NA 0.50 0.44 NA 14 3mm Comfort Select 36 3mm Clear 0.129 0.117 0.639 ARG 90 0.036 CL P1-S N,G 0.75 0.24 53 3mm Comfort Select 36/ARG/3mm Clear 0.28 0.24 NA 0.49 0.43 NA 3mm Comfort Select 28 3mm Comfort E-PS 0.125 0.123 0.514 ARG 95 0.029 0.148 OT P1-S N,G 0.75 0.24 53 3mm Comfort Select 28/ARG/3mm Comfort E-PS 0.20 0.18 NA 0.42 0.37 NA 2mm Solarban 70XL 2mm Comfort E-PS 0.089 0.087 0.678 ARG 95 0.018 0.148 OT P1-S N,G 0.75 0.24 53 2mm Solarban 70XL/ARG/2mm Comfort E-PS 0.20 0.18 NA 0.45 0.40 NA 15 2mm Clear 2mm Clear 0.090 0.090 0.678 AIR CL ZE-D N,G 0.75 0.45 45 2mm Clear/AIR/2mm Clear 0.60 0.52 NA 0.62 0.54 NA 3mm Clear 3mm Clear 0.117 0.117 0.639 AIR CL ZE-D N,G 0.75 0.45 45 3mm Clear/AIR/3mm Clear 0.58 0.51 NA 0.61 0.54 NA 16 2mm ClimaGuard RLE 71/38 2mm Clear 0.090 0.090 0.678 AIR 0.027 CL ZE-D N,G 0.75 0.32 57 2mm ClimaGuard RLE 71/38/AIR/2mm Clear 0.30 0.26 NA 0.53 0.47 NA 2mm ClimaGuard RLE 71/38 3mm Clear 0.117 0.117 0.639 AIR 0.027 CL ZE-D N,G 0.75 0.32 57 2mm ClimaGuard RLE 71/38/AIR/3mm Clear 0.30 0.26 NA 0.53 0.46NA 2mm Solarban 70XL 2mm Clear 0.089 0.090 0.678 AIR 0.018 CL ZE-D N,G 0.75 0.32 57 2mm Solarban 70XL/AIR/2mm Clear 0.21 0.19 NA 0.49 0.42 NA 3mm Solarban 70XL 3mm Clear 0.129 0.117 0.639 AIR 0.018 CL ZE-D N,G 0.75 0.32 57 3mm Solarban 70XL/AIR/3mm Clear 0.21 0.19 NA 0.48 0.42 NA 17 2mm Solarban 70XL 2mm Clear 0.089 0.090 0.678 ARG 90 0.018 CL ZE-D N,G 0.75 0.28 60 2mm Solarban 70XL/ARG/2mm Clear 0.21 0.18 NA 0.49 0.42 NA 3mm Solarban 70XL 3mm Clear 0.129 0.117 0.639 ARG 90 0.018 CL ZE-D N,G 0.75 0.28 60 3mm Solarban 70XL/ARG/3mm Clear 0.21 0.18 NA 0.48 0.42 NA 2mm LoE 366 2mm Clear 0.087 0.090 0.678 ARG 90 0.022 CL ZE-D N,G 0.75 0.28 60 2mm LoE 366/ARG/2mm Clear 0.21 0.18 NA 0.49 0.43 NA 18 3mm LoE 366 3mm Clear 0.117 0.117 0.639 ARG 90 0.022 CL ZE-D N,G 0.75 0.24 49 3mm LoE 366/ARG/3mm Clear 0.21 0.18 NA 0.48 0.42 NA 2mm Solarban 70XL 2mm Comfort E-PS 0.089 0.087 0.553 ARG 95 0.018 0.148 OT ZE-D N,G 0.75 0.24 49 2mm Solarban 70XL/ARG/2mm Comfort E-PS 0.20 0.18 NA 0.45 0.40 NA 3mm Solarban 70XL 3mm Comfort E-PS 0.129 0.123 0.514 ARG 95 0.018 0.148 OT ZE-D N,G 0.75 0.24 49 3mm Solarban 70XL/ARG/3mm Comfort E-PS 0.20 0.17 NA 0.44 0.38 NA

Northeast Windows USA, Inc. NCTL-110-16086-01 A baseline product test in accordance with the "NFRC 102: Test Procedure for Measuring the Steady-State Thermal Transmittance of Fenestration Systems" is required in order to validate the "Model Size Matrix of U-Values" as previously indicated. Per Section 1.4.3 of NFRC 100-2010, the baseline product is the individual product selected for validation testing. The individual product selected as the baseline product shall be the lowest simulated individual product or an individual product having a simulated U-factor within 0.60 W/ (m 2 *K) (0.10 BTU/HR/ft 2 /ºF) or 20% of the listed lowest simulated U-factor. Note: 1. For lowest U-factor listings where multiple individual products are shown, validation testing can be conducted on any within 20% of the lowest simulated u-factor. 2. Actual simulated individual products are required for product line validation testing. For the purposes of validation testing, production line units and sizes shall be used to represent the baseline products. Representative sizes are therefore defined as the production sizes with the least deviation (D) from the model sizes, calculated per NFRC 100. The previously listed model sizes shall be used for baseline product validation testing. Copies of this report and the detailed product drawings will be retained by NCTL for a period of four (4) years. This report may not be reproduced, except in full, without the approval of NCTL. The results only to the fenestration product simulated. The attached diskette(s) contain(s) all required NFRC data and software files. NATIONAL CERTIFIED TESTING LABORATORIES Performed by: Reviewed by: CHRISTIAN J. MITCHELL NFRC Accredited Simulator STEVEN H. COBLE NFRC Accredited Simulator Simulator In Responsible Charge Attachments

Northeast Windows USA, Inc. Report Log NCTL-110-16086-01 Product Line: Northeast Windows USA, Inc. s 400 Vinyl Patio Door. Date: 08/30/13 - Original Report issued to Northeast Windows USA, Inc. and Inspection Agency

ATTACHMENT A Product Drawings

BOM 400 Sliding Glass Door Part Name Part Name Material Cross Section C Patio Door Cross Section Patio Door Main Frame DW2 Vinyl Patio Door Sash Square Nose DW3 Vinyl Reinforcement DW1 Steel Patio Door Interlock DW4 Vinyl Glazing Bead B WDGBTG 3009 Vinyl Spacer