ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

Similar documents
W 12 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. DRIESCHER - Air-Insulated Medium-Voltage Switchgears

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

STROM SICHER SCHALTEN

H 29 H 29 H 29 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

15/60 15/60. FLa ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. Operating and maintenance instructions

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH :85366 MOOSBURG TEL. ( ) FAX ( )

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH D MOOSBURG TEL. ( ) FAX ( )

Rated voltage 12 kv to 38.5 kv Rated current 630 A to 2500 A

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

SAFETY EQUIPMENT FOR RAILWAYS

vertical fuse switch disconnectors

Design of Phase Comparators

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

EQUIPMENT FOR CONNECTION OF A PHOTOVOLTAIC INSTALLATION (UP TO 5 KW)

STROM SICHER SCHALTEN

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

Distribution Blocks & Bus-bar Solutions

Vertical fuse disconnects

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A

2013 JEAN MÜLLER Products

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

with Vacuum Circuit Breaker HAF

LINOCUR Size D02 63A 230VAC/440VAC

EDITION 2011/2012 SAFETY EQUIPMENT

PIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution

EaS devices Overhead Lines. Earthing and Short-circuiting up to 1000 V Fully insulated, shock-proof version 114 Device, fully insulated, Type VI

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Extensible Unit - VCE2a

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

SOUTH AFRICAN NATIONAL STANDARD

Vertical fuse disconnects

Medium voltage Low voltage Outdoor Railway Accessories ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

Switchgear Skid, C1192

IEC Low Voltage General Purpose Protection

Substation Committee K2 TF1 of the GIS Subcommittee GIS/GIL/SF 6 -Tutorials

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

SAFETY EQUIPMENT VOLTAGE DETECTORS. PHE Voltage Detector Nominal voltages up to 30 kv / 50 Hz

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

Vertical fuse disconnects

Cable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples.

OPERATING INSTRUCTIONS

Hand operated drives and accessories. for outdoor switching devices

INNOZED D0 fuse-bases with touch protection

Schedules 1 to 4, Lot B: Extension of the Lessos Substation

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

Linear luminaire with LED Series EXLUX 6002

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

COMPACT SUBSTATION GUIDE

Medium Voltage Distribution PI 100. up to 24 kv Air-insulated circuit-breaker switchgear for primary distribution. System configuration

3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR

EARTHING AND SHORT CIRCUIT LANCE DEVICE RAILWAYS

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Air-insulated switchgear UniGear type ZS1

SWITCHGEAR DIVISION PRODUCT PROFILES

Multipole Conductor Rail MultiLine Program 0831

Medium Voltage Metal-Enclosed Switches

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Summary Catalogue. In 1998, the daughter company DRIBO Stará Turá s.r.o. (Ltd.) was founded in the Slovak Republic.

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Manual for installation and operation HB 602/05 en. ZX2 Gas-insulated medium voltage switchgear

Outdoor Padmount Switching Products

Linear Luminaire with LED Series EXLUX 6002

Small Powered Vacuum Lifters. for horizontal transports. Easy Solutions For Heavy Loads. Small Powered Vacuum Lifters

General characteristics

ZX-Family Gas-insulated medium voltage switchgear

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

uni-cart THE RIGHT CHOICE WHERE SPACE IS AT A PREMIUM uni-cart

Medium Voltage Metal-Enclosed Switches

Chapter 6 Generator-Voltage System

Item Code Description Unit Qty Total

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

PIX High. Medium-voltage switchgear. Air-insulated switchgear kv ( 50 ka) Assembly - Operation - Maintenance Technical Manual

SF6 LOAD BREAK SWITCH. Remote Controlled OCR TELE_1_2013.EN

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

ACCESSORIES FOR SZE2 CABINETS

MOULDED CASE CIRCUIT BREAKERS BC160N

Earthing Switch Class B Hochspannungstechnik Peters & Thieding GmbH

NEXT STEP B) SAFETY :

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories

MOBILE SUBSTATION GUIDE

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

Instruction manual. EK6 Earthing switch 36/40.5 kv

SafeLink The Ultimate RMU. Rex de Bruyn PTMV New Zealand. ABB Ltd - Page 1 ABB

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Emergency Light Fitting for Fluorescent Lamps Series 6009

CPG.0 Single busbar gas-insulated cubicles

B kv Gas-insulated Substations

power cable accessories

Transcription:

773 DRIESCHER Medium voltageswitchgear and substation accessories 773 773 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D853 MOOSBURG TEL. +49 87 80 FAX +49 87 8 2 30 http://www.driescher.com infoservice@driescher.de

DRIESCHER Medium voltage switchgear and substation accessories 2 Index of contents 3 Insulating sticks, earthing sticks 4 Switching sticks, fuse tongs 5 Voltage detectors Spherical and ground terminal studs 7 Earthing and shortcircuiting devices 8 Insulating protective barriers 9 Operating levers, hand cranks 0 2 3 4 5 Key, storage devices for substation accessories, insulating protective barrier and HHcapacity fuses Warning and information signs Other substation accessories Conductor support for flat bars, cable fixing crossarms LVcable connection crossarm, MVconnection crossarm, earthing switch for transformer earthing Lubricants and cleaning agents, shortcircuit indicator, General Production program 2

DRIESCHER substation accessories medium voltage range Insulating sticks DIN VDE 08 part made of glass fibre reinforced polyester with bayonet input for the handling of insulating protective barriers Only for indoor substations! Rated voltage 30 kv 30 kv Partno. 773 4305 773 43020 L G 500 2000 L 0 500 900,25,55 Pic. : Insulating stick Earthing sticks DIN EN 235 made of glass fibre reinforced polyester Only for indoor substations! Partno. L G L I for the spindle of the earthing device max. load in kg 773 20 773 25 773 220 000 500 2000 430 930 430 35 35 20 0,90,,48 773 0 773 5 773 20 000 500 2000 430 930 430 with hexagon with hexagon with hexagon 35 35 20 0,45 0,0 0,75 Pic. 2: Earthing stick while mounting of a earthing device Pic. 3: Earthing stick with universal clamp Pic. 4: Earthing stick for spindle 3

DRIESCHER substation accessories medium voltage range Switching sticks DIN VDE 08 part 2 made of glass fibre reinforced polyester Only for indoor substations! L H L I L 0 L G Rated voltage Partno. L G L H L I L O Pic. 5: Switching stick with switching rod head 23 kv 23 kv 254 kv 254 kv 772 00 772 002 772 003 772 004 000 500 2000 2500 300 400 500 00 525 525 720 720 75 575 780 80 0,85,20,50,80 Fuse tongs DIN VDE 08 part 3 made of glass fibre reinforced polyester Only for indoor substations! 3) K=clamping range for min. and max. protective diameter. Clamping range with reducer (accessories) 30 0 mm a) b) Rated voltage Partno. L G L H L I L O K 3) mm bis 3 kv bis 3 kv bis 3 kv a a b 772 20 772 20 772 220 00 500 250 350 780 540 525 525 525 85 95 85 50 90 50 90 50 90 3, 3,2 2,9 HE 49850/ HE 49850/2 HE 402322 Pic. : Fuse tongs straight Pic. 7: Fuse tongs angled 4

DRIESCHER substation accessories medium voltage range Voltage detectors DIN VDE 082 part 4 / EN 3 made of glass fibre reinforced polyester passive voltage detector with optically LEDindicator Only for indoor substations! DIN VDE 082 part 4 / EN 3 made of glass fibre reinforced polyester optically indicator with implemented operator control mechanism Only for indoor substations! DIN VDE 082 part 4 / EN 3 made of glass fibre reinforced polyester optically indicator with implemented operator control mechanism For indoor and outdoor substations! 2 3 Rated voltage kv 0 kv 20 kv 20 kv 20 kv 2 3 Partno. 773 309 773 30 773 32 773 3 773 32 L O 720 720 720 775 770 L G 425 425 425 480 5 0,83 0,87 0,95 0,97,00 Pic. 8: Passive voltage detector with optically LEDindicator 5

DRIESCHER substation accessories medium voltage range Spherical terminal and ground terminal studs 3 4 5 7 Spherical ø 20 K 20 K 20 K 20 K Spherical ø 25 K 25 K 25 K 25 K Spherical ø Partno. G h H L SW t 3 4 5 3 4 5 7 7 38 00042 38 00002 38 00040 38 0004 Partno. 38 00047 38 00003 38 00045 38 0004 Partno. 38 00004 38 00005 G G M 25 25 25 25 h 33 33 h 0 2 37 0 H 53 75 H 59 59 0 57 L 8 8 98 73 L 55 2 L 35 L 45 L SW 27 27 27 27 SW 32 4 5 5 5 t 5 5 5 t 0,9 0,3 0,7 0,9 0,27 0,22 0,3 0,44 0,2 0,2 Pic. 9: Ground terminal studs Pic. 0: Spherical terminal studs

DRIESCHER substation accessories medium voltage range Earthing and shortcircuiting devices DIN VDE 083 Teil 00 / EN 230 Only for indoor substations! Pic. : Earthing and shortcircuiting devices with cross pin and universal clamp rope diameter for shorting / earthing shortcircuit current I K s Partno. Type phase end Type operating spindle Type earthing end 50/25 mm 2 70/35 mm 2 95/35 mm 2 20/50 mm 2 50/25 mm 2 70/35 mm 2 95/35 mm 2 20/50 mm 2 9,9 ka 3,8 ka 8,7 ka 23,7 ka 9,9 ka 3,8 ka 8,7 ka 23,7 ka 773 00 773 05 773 0 773 5 773 20 773 25 773 30 773 35 3,9 4, 4, 5,9 3,9 4, 4, 5,9 50/50 mm 2 70/70 mm 2 95/95 mm 2 20/20 mm 2 50/50 mm 2 70/70 mm 2 95/95 mm 2 20/20 mm 2 9,9 ka 3,8 ka 8,7 ka 23,7 ka 9,9 ka 3,8 ka 8,7 ka 23,7 ka 773 40 773 45 773 50 773 55 773 0 773 5 773 70 773 75 with hexagon with hexagon with hexagon with hexagon 4,2 4, 7, 8,5 4,2 4, 7, 8,5 All ESdevices earthing end also available with universal earthing clamp with synthetic handle. Moreover earthing and shortcircuiting devices on demand. Pic. 2: Mounting of a earthing and shortcircuiting device with a earthing stick Pic. 3: universal clamp with earthing end synthetic handle 7

DRIESCHER substation accessories medium voltage range Insulating protective barriers corresponding to pictures, 2, 3 and 4 according to DIN VDE 082552 8 9 0 ) Information sign according to EN 227200 8 8 8 8 8 9 0 For switch panel type Partno. Length a Width b Thickness Colour W20759 W275752 W290752 W802 W902 kv compact switchgear F059 453 587 453 5872 453 5873 453 584 453 75094 780 8030 453 5884 453 589 800 730 730 80 795 400 25 800 50 0 80 90 20 094 395 434 8 8 red red red red grey grey red red 3,2 3,8 4, 5,5,8 7,0 3, 2,2 HA 4077/ HA 4077/2 HA 4077/3 HA 407722/3 HA 30773/3 HA 3077/2 KS 407737/ HA 407723/2 Insulating protective barriers with other dimensions, customer specific barriers or inflected protective barriers on request! Therfore please use attached register sheet. Examples for customer specific barriers 8 Pic. 4: Inserting of a protective barrier

DRIESCHER substation accessories medium voltage range Operating levers Steel parts galvanized! 2 Type Partno. L 3 straight for operating lever actuator 2 2 774 9350 774 9500 35 55 0, 0,88 with hexagon head 3 774 92500 55,25 for Dactuator Other customer specific versions on request. AZ 43794 AZ 43794 AZ 44399 Hand cranks 25 20 A 0,2 Steel parts galvanized, partially with torque clutch for indoor substations! 30 2 Application Torque clutch Partno. A B S 4 B344 Vakuum circuit breaker manual charging fixed mounting withdrawable version yes 770 03 770 08 4 5 50 84 LS 409793 AZ 400095 9 5 340 insert socket square SW 2 ø25 Motor drive UM hand crank UM20 / UM30 extended hand crank for UM 0 / UM 5 extended hand crank for UM 0 / UM 5 extended hand crank for UM 0 / UM 5 extended hand crank for UM 0 / UM 5 yes yes yes yes yes 77 000 770 025 770 02 770 02 770 027 7 7 7 7 49 4 0 5 28 82 000 875 2375 375 30 30 30 30 30 AZ 403348 AZ 30837 AZ 304809 AZ 307 AZ 3077 Other customer specific versions and different lenghts on request. A 525 B 332 S 7 Pic. 5: Operating lever, hand crank and key 9

DRIESCHER substation accessories medium voltage range Key 8 Partno. Application ca. kg 9 8 9 20 382 0020 382 00209 39 00004 for fastener lock with thorn ø 5 for fastener lock with square 7 for socket cap screw M0 with hexagon socket head 0,05 0,05 0,5 20 Storage devices for optimal storage of your substation accssories Steel parts galvanized Clamp for Partno. Substation accessories Insulating protective barrier 2 4 007 30000 2,55 0,5 22500 HA 404205 2 Pic. : Clamp for substation accessories and insulating protective barriers Storage devices for HHcapacity fuses Steel parts galvanized for kv Partno. a 2 3 773 000 773 000 773 000 303 453 548 0,85 0,85 0,85 HH 404350 HH 404350 HH 404350 0

DRIESCHER substation accessories medium voltage range Warning and information signs 40 M Signno. Partno. Dimensions mm On set unit V M V 4 R G 2 R 50 M 7 R Z a R 5 M 52 M 40 M 40 000 470 002 470 004 40 00 470 0002 470 00 40 0002 40 0003 40 0005 20 x 297 ø 200 ø 200 200 x 0 200 x 20 20 x 74 400 x 00 500 x 700 30 x 520 no switching work is carried on place removal of the sign only by... symbol / no switching danger exists five safety rules high voltage danger of life Attention! grounded and interconnected! reverse voltage VDEstandard for operation of high voltage installationsvde 005 part /5.75 leaflet for fire prevention VDE 0 32t2.79 emergency acction in case of accident by electrical current 2 2 2 Satz 780 80800 set of warning and information signs standard according to VDE 005 All warning and informatin signs are available for magnet mounting. Pic. 7: Set of warning and information signs

DRIESCHER substation accessories medium voltage range Designation Other substation accessories Description Partno. Insulating mat Insulating mat handheld fire extinguisher LED Work and hand emergency light with charging set Wall holder for emergency light Wall desk Circuitdiagram pocket Safety bar Safety bar Mounting for safety bar Mounting for safety bar Occupational safety helmet without safety screen Safety screen for occupational safety helmet Touchup paint Plastic cable clamp Plastic cable clamp Substation documentation Screen mat for elec. control rooms according to VDE 0303, width m Screen mat for elect. control rooms according to VDE 0303, width,2 m Carbon dioxide, 5 kg, suited for elec. substations according to DIN 440 Optimal lighting for operating area, LED, V / 7 Ah Wood, DIN A3 resting surface with box Carbon dioxide, DIN A4 on edge, selfstick 0 x 7 mm, L = 200 mm, red, hardwood smooth planed 0 x 40 mm, L = 80 mm, red, hardwood smooth planed Sheet, for safety bar 0 x 7 mm, hotgalvanized Sheet, for safety bar 0 x 40 mm, hotgalvanized Specialpolyethylene, according to DIN EN 397 against iternal fault, antifog, according to DIN EN kg (500ml), different RALcolors K 2/38 K 3/52 DIN A4, 2 pages 75 7002 75 700 389 0000 337 0044 337 0045 389 02005 3 0303 8 00030 8 00040 2 52700 2 4990 389 0020 389 002 9 xxxx 395 0005 395 000 89 000 Pic. 8: LEDHand emergency light in the wallmounting holder and mounting for insulating protective barriers Pic. 9: Insulating mat 2

DRIESCHER substation accessories medium voltage range Conductor support for flat bars Typ III Ground and end plate hot galvanized for indoor and outdoor for flat bars up to 40 x 0 from 40 x 0 to 0 x 0 from 0 x 0 to 00 x 0 s 55 75 5 for single bus bars Partno. 773 28040 773 2800 773 2800 h 2 2 28 for double bus bars Partno. 773 28042 773 2802 773 2802 h 48 0,35 0,45 0, HE 443795 HE 443795 HE 443795 Typ IV Ground and end plate hot galvanized for indoor and outdoor, stainless screws for flat bars (vertical bars) Partno. h 40 x 0 50 x 0 0 x 0 80 x 0 00 x 0 773 29040 773 29050 773 2900 773 29080 773 2900 5 7 9 0,39 0,42 0,45 0,5 0,57 HE 404379 HE 404379 HE 404379 HE 404379 HE 404379 Conductor and final conductor support hot galvanized Terminal screws x 40 with nut, spring washer and shed are included Designation Partno. Conductor and final conductor support 773 20040 0,38 HE 4093292 Cable fixing crossarms 22 a) b) Cable fixing crossarms hot galvanized 23 Traverse Partno. 22a 22b 23 Angle section Anchor bar Angle section adjustable 2 05347 4 33820 773 90400 3,73 HA 402725/3a 2,70 HA 402725/3b 3,40 HA 402725/4 3

DRIESCHER substation accessories and more Low voltage cable connection crossarm Low voltage cable connection crossarm Steel parts hot galvanized Cable connection crossarm Partno. for 30 kva transformer up to max. 90 A nominal current for 30 kva transformer up to max. 800 A nominal current for 30 kva transformer up to max. 2900 A nominal current 773 90300 773 90230 773 90232 HA 402725/ HA 40977/ HA 40977/2 Medium voltage cable connection crossarm Medium voltage cable connectin crossarm Steel parts hot galvanized 275 275 ) Terminal screws x 40 with nut, spring washer and shed are included Pic. 20: medium voltage cable connection crossarm Rated voltage Cable connection crossarm Partno. H 2 kv kv kv kv without spherical and ground terminal studs without spherical and ground terminal studs with spherical and ground terminal studs ø20 /M2 with spherical and ground terminal studs ø25 /M2 773 9022 773 902 773 90225 773 90227 2 2 2 2 7,35 9,00 0,00 0,25 HA 402725/2a HA 402725/2b HA 402725/2c HA 402725/2e 3pol. indoor earthing switch for transformer earthing on high voltage side 3pol. Indoor earthing switch for high voltage transformer earthing Steel parts hot galvanized Drive components: shaft extension AZ 44385 bearing block AZ 3400/3, bushing for Dactuator AZ 44400, operating lever AZ 44399 Rated voltage Rated shorttime current x / y c p L Earthing switch Partno. 2 2 20 ka 3,5 ka 20 ka 450 450 55 00 00 750 20 20 275 325 325 405 ES 220 ES 23,5 ES 20 734 030 734 040 734 7030 IT 403277/ IT 403277/2 IT 403277/3 4

DRIESCHER substation accessories and more Lubricants and cleaning agents Designation Application Partno. Delivery type Quantity Rivolta S.K.D. 4002 Barrierta L55/ Rivolta S.K.D. SÄKAcleaning paste Rivolta S.L.X. 500 Rivolta M.T.X. 0 forte contact lubricant for indoor switches contact lubricant for outdoor switches and partly for indoor switches lubricant for hinge and slide points cleaning paste for insulators and other insulating parts cleaning of contact surfaces covered with Barrierta high capacity cleaner 490 070 490 0702 490 070 490 09003 490 0902 490 0900 tube tube spray tube spray spray 00 g 0 g 400 ml 750 g 300 ml 400 ml Shortcircuit indicator Shortcircuit indicator with liquid crystal display 25: Clamp yoke 2: Hinge yoke for flat bars Mounting Partno. Operating current (min) H 25 2 30 x 4 bis 40 x 5 30 x 4 bis 40 x 0 Clamp yoke Hinge yoke 337 0300 337 03002 400 A 400 A 82 49 0,23 0,7 General Brochure 7 Brochure 774 Brochure 77 Brochure 80 Brochure 89 indoor / outdoor insulators and bushings indoor actuators and accessories outdoor actuators and accessories low voltage switchgears and substation accessories NHcapacity fuses 5

Our range of products includes: Mediumvoltage systems Singlebusbar and duplicatebusbar switchgear Fixed mounting, withdrawable design and trucktype units Compact switchgear assemblies Customerspecific models Industrial switchgear Power factor correction and filter equipment Mediumvoltage switches Indoor loadbreak switches, disconnectors, and earthing switches (single and triple pole) Indoor circuit breakers (low oil content and vacuum) Outdoor loadbreak switches, disconnectors, and earthing switches (single and triple pole) Railway switches for power supply and catenary Highvoltage highbreakingcapacity fuses Customerspecific switches Lowvoltage systems Openframework design Enclosed switchgear (up to.300 A) Motor Control Center (MCC) Cable and fixedstation distribution cabinets Lowvoltage switches Switch disconnectors Switching strips and fuse blocks Compact substation Concrete construction Container construction Driving gear Handoperated and motoroperated mechanisms for indoor and outdoor application Accessories For medium and low voltage For station equipment Insulators (0,5 kv 38,5 kv) Plastic and glass fibrereinforced plastic screening Service Maintenance and Service of all switches and switchgear Training courses and seminars Thermography; Liveline working Dimensions, weights, diagrams and descriptions in the list are nonbinding. Subject to change without notice. STROM SICHER SCHALTEN ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH Orderno. 38707730 095