Mediclean Complanate Ultra Clean Ventilation

Similar documents
Quasar elite Duo Single Cardanic

ULTRASUITE. Operating Room Diffuser System with Integrated LED Lighting

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

GEA Clean Rooms. Modules with laminar air flow for ceiling installation GEA Fresh Heaven j^uu GEA Fresh Heaven j^uu=mltbo.

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

CG2010 Cytogard Cytotoxic Drug Safety Cabinets

GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE.

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

GloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE.

is with a variety of standard dimensions. Also our units can be custom engineered to any size.

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

Laminar ceilings, exhaust columns, exhaust grilles

OIL-INJECTED MEDICAL AIR COMPRESSORS GA 5-11 MED / GA MED / GA 7-37 VSD+ MED

PRECISION UK Ltd DUPLEX AGSS PLANT

Stainless Steel Theatre Furniture. Stainless Steel Theatre Furniture. Manufactured to the highest possible standards

AS , EN12469 (Microbiological Testing Method)

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

MiniRoom. Isolation cubicles flexibility with containment. Horizontal laminar flow of air for greater protection - positive or negative

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Thermo Scientific 1300 Series A2. Class II, Type A2 Biological Safety Cabinets. Good for you good for the environment

Ceiling swirl diffusers

KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology

Series. Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry

Indirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160)

Class II biological safety cabinets

Healthcare. Sterile Storage. STAT. You need it quick, clean, controlled, and secure.

& DEPYROGENATION OVENS

MULTILINE NEXT AC. MOBILE PATIENT COUCH FOR OUTPATIENT SURGERY.

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

Ceiling swirl diffusers with perforated face plate

Series EuroFlow Biological Safety Cabinets Class II

SafeFAST Premium. Class II Microbiological Safety Cabinets THE LOWEST POWER CONSUMPTION THE LOWEST CO 2 EMISSIONS THE LOWEST NOISE LEVEL

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET.

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

GE Healthcare. OEC Brivo Plus. The confident choice. It s simple.

MAXI SKY with people in mind

CytoFAST Elite. Cytotoxic Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

TM Series MICROBIOLOGICAL SAFETY CABINETS. Technical Specifications

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

MAXI SKY 600 THE COMPLETE, CUSTOMISED CEILING LIFT SYSTEM

LAMINAR AIRFLOW EQUIPMENT

Miracle State Of The Art Air Filtration System!

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Ceiling swirl diffusers

Bio II Advance. Class II Biological Safety Cabinet

A Thermolab Group Company. HyZone. Class II Microbiological Safety Cabinets. for operator, environment and product protection.

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

MUNICIPAL AND INDUSTRIAL DEWATERING APPLICATIONS ROTARY PRESS OPTIMUM-CV

Envirco BIOLOGICAL SAFETY CABINET

TITAN, ATLAS & SIRIUS SMALL, PORTABLE. economical cabinets. with low energy consumption

DATA & FACTS Clean Rooms Fresh Heaven MAXX Fresh Heaven MAXX POWER. Laminar Air-Flow Units for Industrial Applications and Ceiling Installation

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

CytoFAST Elite. Cytotoxic Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

##CFG BWOP Manuals## Quasar elite HD-LED Mobile Models Assembly Guide

Aeolus V. Green Line. Product protection. Vertical Laminar Flow Cabinets. High quality. Ergonomic design. Low noise level.

HEPA Filter Module For critical air environments

SC330 SC Lojer Oy Putajantie 42, P.O. Box 54, FI Sastamala, Finland Tel (0) Fax +358 (0)

When Time Matters! listed Fire Damper

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Taking small steps together, always ahead, towards a better world. Optima CG / Optivent CG. Innovative Laminar Flow Solutions for Operating Theatres

Swimming Pool CSR2 Heat Recovery Equipment

LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL

ICU/CCU Doors You Can Depend On

Maximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment

AMENDMENTS Dated: August 25, 2010

Automotive Spraybooths

Air Curtains for Revolving Doors

Unimodule M2 Unidirectional Flow Clean Bench/Workstation OPERATION MANUAL

THE BETTER WAY TO CREATE CONTAINMENT

CRYSTAL-AIRE. concealed commercial air cleaners

Bio II Advance. Class II Biological Safety Cabinet

FOR AIR CONDITIONING AND VENTILATING APPLCATIONS

T & M Series Couplings. Metal membrane couplings for the oil & gas industry

3603 Ultra Slide. Surgical Table

Maxi sky 600. with people in mind

BIOLOGICAL SAFETY CABINET

MINI-VERTICUS & VERTICUS THE NEXT GENERATION COMPRESSORS FOR SPORTS & SAFETY APPLICATIONS

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS

Circulaire. Superb Containment, Excellent Capacity. Filtration Fume Cabinets

GLOVE BOX GALLERY. Inert Gases. Temperature and Humidity

ARCHITECTURAL ALUMINIUM SOLUTIONS. Door Closers. Comfort and safety. Sapa Building System

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Smart By Design Flexible By Nature

MOBILAIR M 350. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 24.0 to 34.0 m³/min (850 to 1200 cfm)

Downflo workstation DuSt ColleCtorS

FilterBox Wall. Automatically or manually cleaned for dust & fume applications.

HGPL HOSPITAL GRADE LAMINAR FLOW COMMON PLENUM

CDC F RANGE NEGATIVE PRESSURE ISOLATORS

Rotating Power AC Motors and Generators

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

E-PAPER BUS STOPS. The ideal partner of Papercast E-Paper displays STRONG, LONG LASTING & LIGHTWEIGHT CONSTRUCTION

Transcription:

Mediclean Complanate Ultra Clean Ventilation complanate adjective com pla nate \ kämpləˌn t\ : made level : in one plane, flattened to a level surface : Latin complantus

Mediclean Brandon Medical Brandon Medical is a British company established in 1946 to design and manufacture world-leading technology for healthcare. We specialise in reliable and innovative medical equipment for operating theatres, critical care, imaging suites and emergency departments. Heritage We are proud to say, when Prof John Charnley developed the first UCV systems to reduce infection rates from hip replacement surgery, he came to Brandon Medical to develop operating lights that didn t obstruct the flow of clean air. We have over 50 years experience working with leading UCV manufacturers to provide the best solutions for aseptic theatres. Weiss Klimatechnik Weiss Klimatechnik and Brandon Medical have worked together since 2006 to deliver UCV operating theatres in the UK and overseas with over 8,000 installations completed Worldwide.

Why choose Mediclean UCVs? The latest Mediclean UCVs improve patient safety and surgical outcomes by providing unique benefits to hospital designers, surgical staff, estates and maintenance engineers. Complanate & Screen-Less We recommend complanate systems for new operating theatres that fit completely flush to suspended ceilings without the need for air deflectors or side screens. This makes it easy to position operating lights, pendants and imaging machines without obstruction or collision damage. Mediclean uses proven pharmaceutical industry air curtain technology, to separate the ultra clean air from the surrounding dirty air and to control entrainment. Mediclean makes the Invisible Visible! Our patented Continuous Particle Monitoring (CPM) measures airborne particles in real-time and uses simple visual alarms. Clinical staff can see when the air isn t clean due to entrainment or surgical smoke and can take steps to protect themselves and their Patients. CPM is a Mediclean option or available as a stand-alone system. Real-Time Automatic Optimisation of Air Quality Mediclean CPM automatically increases airflow to quickly flush out airborne particles and surgical smoke as soon as they are detected. Alarm thresholds can be set by the user and the system includes data logging to record the air quality during each surgical operation.

Mediclean Complanate & Screen-Less Complanate means, to make level or to put into a single plane which describes perfectly how Mediclean UCVs fit flush with the operating theatre ceiling. Mediclean uses a unique air curtain technology to constrain the flow of clean air within the clean zone and to separate it from entrainment by the surrounding dirty air in the rest of the room.

No Side Screens, No Coanda Air Deflectors, No Protruding Enclosure The diffuser surface is completely flush with the suspended ceiling, without any protrusion from the UCV unit into the room. The air curtain eliminates the requirement for side screens and coanda effect air flow deflectors that would normally protrude below the ceiling. The clear advantage is that Mediclean does not obstruct the movement and positioning of operating lights, medical pendants or medical imaging equipment. It is easier for Designers to design ergonomic equipment layouts, easier for staff to position equipment during surgery and damage from collisions with the UCV side screens and air deflectors is eliminated.

Mediclean Making the Invisible Visible It s impossible to see clean air with the naked eye, so CPM samples the air to accurately measure the number of particles present during surgery and displays the results as visible signals. CPM supplements the annual UCV validation tests done in empty theatres to indicate that the UCV is working efficiently during real live operating conditions. Mediclean CPM is the first system in the World that allows staff to see how clean the air is during surgery. Automatic Optimisation of Air Quality When particles are detected, Mediclean CPM systems automatically increase the air flow from the UCV to quickly flush the contamination away from the safety critical area, protecting both patients and surgical staff. The system automatically returns to normal operation when safe operating conditions are restored.

Safer for Staff Smoke from electro-surgery is known to be hazardous. It can contain as many as 72 harmful contaminants including known carcinogens and intact viable DNA. CPM detects harmful particles of smoke as well as dirty air. Mediclean reacts with a visual warning of the risk to the surgical team and by increasing the airflow to clear the smoke away from the clean zone, protecting surgeons and staff from inhaling smoke. Improving Patient Outcomes When surgical staff can see reductions in the air cleanliness, they can adapt their working to protect the Patient. Staff can also see which activities cause loss of air cleanliness and learn to avoid them, improving their working practices to maintain cleanliness in the clean zone and reduce the risk of infection for the patient. Data Logging Mediclean CPM includes data logging to record air quality during each operation. This information can be correlated with patient data and used to understand the sources of infections and drive improvements in surgical outcomes.

Mediclean 12 More Reasons for Selecting Mediclean 1. Flexible Design Mediclean is the ultimate in flexibility and can be configured for virtually any application. n Complanate or side screen systems n Integral fan or remote fan systems n Rectangular or square units are available with sizes from 1.4m to 3.5m n With or without CPM 2. Hybrid Theatres The complanate, single plane design and flexibility of Mediclean UCVs makes them ideal for Hybrid theatres. Pre-engineered solutions are available for many of the leading imaging systems including those from Philips and Toshiba. 3. Low Ceiling Models Systems are available with unit depths of only 350mm to fit into very low ceilings. We will design bespoke configurations to optimise low ceiling installations. 4. CE Marked Mediclean is fully CE marked in compliance with current EU Directives. 5. Noise Standard models meet the HTM 03-01 requirements of NR50 or less. Ultra-quiet models with remote fans are also available. 6. Lower Weight Aluminium Construction Super-light aluminium design weighs as little as 800 Kg reducing the load on building structures and building costs.

7. Lowest Energy Consumption Energy consumption is minimised by reducing the load on the fans. Primary and re-circulated air is mixed downstream of the re-circulation fans and air resistance inside the unit is minimised using a single plenum chamber design. 8. Triple Filtered Air Mediclean uses Triple Filtered Air to prolong the life of the filters. An easy to clean mechanical lint filter doubles the life of the pre-filters which in turn protect the HEPA filters. 9. Cleanable Diffuser Blood splashes or stains on the diffuser screen are easy to see and easily cleaned away compared to perforated mesh. 10. Anti-Reverse Airflow Dampers In the event of power interruption, Mediclean is designed to protect the cleanliness of the Operating Theatre by preventing any reverse air flow back through the HEPA filters and recirculation modules with anti-reverse flow dampers. 11. Installation Service We offer a full pre-site inspection, installation and commissioning service by trained Brandon Medical engineers. 12. Independent Validation Testing Final validation testing is carried out by an independent third party specialist, so you can be assured all units fully comply with HTM03-01.

Mediclean Technical data Operating Light Integration Brandon Medical s Quasar elite operating lights are designed for integration with Mediclean UCV systems. The lights have been tested to and exceed the DIN 1946 Part 4 (12-2008) standard requirements for operating lights in ultra clean theatres. Pendant Integration Multi-movement pendants can be easily integrated on any of the 4 sides of complanate Mediclean units, as they are fully recessed with no obstructions to the pendant movements. Pendants can also be mounted much closer to the clean zone so shorter arms can be used, reducing costs and loads on the building structure. Side Screen UCV Systems The Mediclean range includes conventional, integral fan and remote fan systems with partial side screens if required. Side screen are with 6mm safety glass of flexible plastic curtains. Media Bridges Conventional UCV systems are available with integral media bridges to provide all the services around the clean zone where pendant access is limited by the side screens. Background Lighting LED lighting packages are available to illuminate the clean zone or for the complete operating theatre, with highly uniform light of 1,000 Lux intensity. Brandon Equipment Package Mediclean UCVs are part of Brandon Medical s equipment package comprising of Isolated Power Supplies, UPS, theatre control panels, PACS stations, operating lights, medical pendants and medical AV solutions.

UCV Size 2.6m x 2.6m 2.9m x 2.9m 3.2m x 3.2m 3.5m x 3.5m Relevant Standards CE, HTM 03-01 2007, DIN 1946-4:2008-12, 2009/125/EC. 2014/30/EU, 2006/42/EC, EN ISO 12100:2010, 2014/35/EU, EN60204-1:2006 UCV Plenum Size (LxWxH mm) 2575x2575x550 2879x2879x550 3185x3185x550 3559x3489x550 Recirculation Air Modules Size (LxWxH mm) 2575x980x690 2879x980x690 3185x980x690 3489x980x690 Min. Overall Length (mm) 4940 5240 5545 5919 Min. Distance Between Modules (mm) 200 Min. Total Assembly Weight (Kg) 740 810 870 940 Total Energy Load 4 Fans Clean Filter (kw) 0.7 0.9 1.22 1.22 Total Energy Load 4 Fans Used Filter (kw) 1 1.23 1.52 1.52 Required Total Air Volume (m 3 /s) 2.5 3.17 3.86 4.72 Min. Fresh Air Volume HBN26 55m 2 OR (m 3 /s) 1.15 1.15 1.36 2.22 Additional Air For Air Curtain (m 3 /s) 0.14 0.17 0.18 0.21 Noise Level (Nr) <= 50 Intake Filter Grade Pre Filter Grade Terminal Filter Grade G3 F7 H14 Brandon Medical is certified as an ISO 13485 and ISO 9000 manufacturer, the global standard for medical device manufacturers. UK Customs Approved Exporter Status GB 16164/13

Brandon Medical Co Ltd, Elmfield Road, Morley, Leeds, LS27 0EL T: +44 (0)845 1243 666 F: +44 (0)845 1243 667 T: +44 (0)113 2777 393 F: +44 (0)113 2728 844 E: enquiries@brandon-medical.com www.brandon-medical.com In line with the Brandon policy of progressive improvement, the right is reserved to alter specifications and/or pieces without notice. Brandon Medical, Astralite, HD-LED and Symposia are registered trademarks of Brandon Medical Co Ltd. 01/10/2016 14587-A1