DIKE AND SPILL PROTECTION

Similar documents
Fixed or Semi-Fixed Foam Fire Protection Systems for Storage Tanks

Installation & Design Maintenance for ILBP System

The Challenge: Ethanol / Ethanol blended fuels. What does this mean to the Fire Service? Presented to the Reebok foam seminar by:

Foam Maker Discharge Devices Model KLF

Wet pipe low flow foam/water manifold system

TECHNICAL DATA OBSOLETE

To establish a standardized procedure for Class B foam application by engine companies.

GFGV.EX15965 Foam Liquid Concentrates. Foam Liquid Concentrates

Section R Foam Systems

Section R Foam Systems

Foam Chambers DATA SHEET. Features. Application. Flow Range. Description

Foam Ratio Controller Proportioning Devices Model KFP

FIRE PROECTION EQUIPMENT

Module 4: Fire Fighting Foam Principles and Biodiesel Fuel

TECHNICAL DATA. Table Standard Materials

FOAM RATIO CONTROLLER (Between Flange) HARDWARE

HELICOPTER DECKS AND FACILITIES (HELIDK AND HELIDK(SRF)) APRIL 2008

In-Line Balanced Pressure Proportioner (ILBP) Proportioning Devices Model KBP

FIREFIGHTING FOAM PRODUCTS CATALOG

Applications Closed Head Foam-Water Sprinkler Systems Aircraft Hangars Flammable Liquid Warehouses, Drum Storage Facilities

TUV India Private Ltd. APPROVED

MANUAL: Foam Attachments for TFT Nozzles

WAFER STYLE ILBP PROPORTIONING MODULES WITH CHECK VALVE. NPR160 Approvals: UL, ULC

MCS TYPE B FOAM MAKER & FOAM CHAMBER NDD010. Approvals: UL, ULC

MANUAL: Foam Nozzles and Foam Attachments for TFT Nozzles

GFGV.EX6202 Foam Liquid Concentrates. Foam Liquid Concentrates

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Table Standard Materials

Industrial Electric Monitors. Industrial

TECHNICAL DATA. Table Standard Materials

MANUAL: Foam Attachments for TFT Nozzles

MONITORS DESCRIPTION. Grease fitting for lubrication

MANUAL: Foam Aspirators

INLINE FOAM INDUCTOR HD FIRE PROTECT PVT. LTD. TECHNICAL DATA DESCRIPTION SPECIFICATION APPLICATION SYSTEM DESIGN DETAILS

Innovative Firefighting Products

MANUAL: MASTER FOAM FIXED GPM SELF-EDUCTING FOAM NOZZLE

Storage and Dispensing Locations

Big Flow Systems. Major innovations in fire fighting and water transfer technology

GFGV.EX26590 Foam Liquid Concentrates. Foam Liquid Concentrates

NORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS

GW M5 WATER MIST NOZZLE K-5, LOW PRESSURE, NON-AUTOMATIC

LASTFIRE FIRE TEST SPECIFICATION WATER MISCIBLE FUELS REVISION A MAY 2015

Quality is Behind the Diamond

FOAM AQUEOUS FILM FORMING FOAM (AFFF) ALCOHOL RESISTANT AQUEOUS FILM FORMING FOAM (AR-AFFF) NEW FOAM CONCENTRATE FOAM NOZZLES FOAM SYSTEMS EDUCTORS

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL DRIVER OPERATOR PUMPING PAGE 1 OF 6 Nozzles & Hose Revised

SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems.

COLLEGE TOWNSHIP CENTRE COUNTY, PENNSYLVANIA ORDINANCE O ZONING REQUIREMENTS FOR STORAGE TANKS ORDINANCE

Pumping Apparatus Driver/Operator Types of Apparatus Equipped with a Pump. Chapter Test

FOAM AQUEOUS FILM FORMING FOAM (AFFF) ALCOHOL RESISTANT AQUEOUS FILM FORMING FOAM (AR-AFFF) NEW FOAM CONCENTRATE FOAM NOZZLES FOAM SYSTEMS EDUCTORS

PA1 - Piercing Nozzle System

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

Assessing Your Sprinkler Irrigation System

BASIC FOAM FIREFIGHTING OPERATIONS Red and Green Systems

Air- Blast Sprayer Calibration for Pecan Orchards

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

ADO-Pumping Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE

WATER SPRAY NOZZLE DATA SHEET

GW THERMOCOOL NOZZLE STRUCTURAL STEEL PROTECTION

OBSOLETE DESIGN DATA. 3", 4", 6" and 8" CONCENTRATE CONTROLLERS

TECHNICAL DATA SHEET. Medium Velocity Water Spray Nozzle. Page 1. Description. Technical and Environmental Specification. Installation & Maintenance

MANUAL: PRO/pak Portable Multi-Purpose Foam System

Table Summary of Sprinkler System Inspection, Testing, and Maintenance. Reference. Inspection , ,

Page 6-6. Page 6-3. Page 6-3. Page 6-5. Self- Educting Foam. Foam Compatible. Location

Color-Coded Polymer Pistol Grip, Valve Handle Covers offer rugged durability in harsh fi refi ghting conditions

Large Capacity Dry Chemical Skid Mounted Units

UNCLASSIFIED AD 296" 475 ARMED SERVICES TECHNICAL INFORMATION AGENCY ARLINGTON HALL STATION ARLINGTON 12, VIRGINIA UNCLASSIFIED

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Type D3S PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP804

THE CARBURETOR: THE ADDITIONAL SYSTEMS

800S Series. Based on proven technology. When creating the 800S Series. sprinkler, we started with. technology that works. Then

Directional Spray Nozzles, Open, with Strainers High Velocity General Description

Datasheet for MATRE BLADDER TANK FOAM PROPORTIONERS

Q= C v P S. Flow control valve Model j-2 Halar coated

Metrovick F2/4 Beryl. Turbo-Union RB199

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL J-2 HALAR COATED 1-1/2 & 2 (DN40 & DN50) 1. DESCRIPTION

PROCEDURE FOR THE HANDLING OF FUEL ON CONSTRUCTION SITES. Civil Engineering Sector Labour-Management Health and Safety Committee

Items # and #

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Spray and Rotary Nozzles

Handline Nozzles. Foam Tubes In Line eductors & Piercing Nozzle. Forestry Products. Firehouse cleaning Products

DT34/DT54 SERIES GOLF ROTORS

Features Four Sizes Superior Foam Quality Operates at 30 PSI (2.1 bar) minimum Tool Free Maintenance Corrosion Resistant Polyester Finish

Total comfort control

Storage and Dispensing Locations

Spray and Rotary Nozzles

BASIC PUMPING OPERATIONS. Red and Green Systems

VENT SILENCER PRODUCT GUIDE

Elements of plumbing

DIRECT-DRIVE PRESSURE WASHERS

Chemguard Foam. Training Foam FOAM. Contact Your Darley Representative With Your Protein or Flouroprotein Foam Needs

SERIES COOLING TOWER SINGLE-CELL UP TO 1500HRT COOLING CAPACITY

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

DIRECT-DRIVE PRESSURE WASHERS

DEMA MODEL 603T-WI INSTALLATION INSTRUCTIONS

Fact File 59 Extinguishing systems

Fixed Ratio Hydra-Cat First choice when quality counts.

Fuel Storage Dec 2016

Transcription:

1 DIKED AREA Dikes are typically constructed around above ground storage tanks. They are contours of land or physical barriers that will retain fuel to a depth greater than 1". At many manufacturing or storage facilities, the flammable liquid storage area can be a number of small tanks within a common diked area. These tanks are often surrounded by pipe rack arrangements and pumps. In instances like this, the total dike area and not the storage tanks could be considered the hazard to be protected by a suitable fixed foam fire protection system. This could be achieved by using: Low level fixed mounted foam makers. Monitors. Foam water spray nozzles or a foam sprinkler system over the hazard area. Supplementary support with portable foam application equipment should also be available. See following chart for application rates. For flammable liquids requiring AR-AFFF type foam concentrate, the discharge duration shall be 30 minutes with the application rate as recommended by Buckeye applications engineering department. If the dike to be protected is located outdoors, additional considerations should be made during the design stage when using either a monitor or foam/water sprinkler system. Climatic conditions such as wind or rain, can affect the performance of these systems. It may be necessary to increase the application rate to compensate for the adverse conditions. If within the dike area there are many obstructions that could impede the performance of the overhead or monitor system, supplementary low level foam discharge devices may be required. If an overhead foam/water sprinkler system is used it should be designed in accordance with NFPA 16 Installation of Foam-Water Sprinkler Systems. The application rate using AFFF on hydrocarbon fuels is 0.16 gpm per sq. ft. On products that are water miscible/polar solvent, the application rate may increase. Contact the Applications Engineering Department at Buckeye for assistance and recommendations. DIKE PROTECTION WITH FIXED MOUNTED LOW LEVEL FOAM MAKERS When using fixed mounted foam makers as the primary protection system for a dike it shall be designed in accordance with the following. A foam solution supply pipe should be installed on the outside perimeter wall of the dike and at equally spaced intervals also mounted on the outside wall, foam makers are attached to the supply pipe. Both the Buckeye 1 1/2" (38mm) and the Buckeye 2 1/2" (63 mm) foam maker should have a minimum of 12" of straight pipe upstream from the foam maker inlet. The discharge pipe from each foam maker is designed to allow for an increase in foam expansion and decrease the velocity of the discharging foam which will then supply a low velocity mass of foam uniformly over the dike area. On the discharge side of the Buckeye 1 1/2" (38 mm) foam maker, it is recommended that a length of 3" diameter pipe be connected to the foam maker outlet and used as the discharge pipe. This pipe should have a minimum length of 28" with a maximum of 100" and shaped to discharge the foam against the inside wall of the dike at approximately 12" above the maximum expected level of any flammable liquid spill. With the Buckeye 2 1/2" (63 mm) foam maker the recommended diameter of the discharge pipe is 4" with the minimum length being 28" and the maximum 120". The maximum spacing between fixed mounted foam makers is 30 feet when the discharge rate from each foam maker is 60 gpm or less and no point within the dike area should be more than 30 feet from any discharge outlet. If the flow rate is above 60 gpm, the maximum distance between each foam maker around the dike perimeter can be increased to 60 feet and no point within the dike being more than 60 feet from any discharge outlet. Large dike areas are permitted to be subdivided to keep the total design solution within practical limits.

2 Fig. 11 shows a typical dike protection system using low level foam makers. MONITOR PROTECTION If foam monitors are used as the primary protection method, they should be located outside the dike area. If non air-aspirating type nozzles are used or the monitor has a high velocity discharging stream. It should be directed against the dike wall, tanks, or other structures within the dike to lessen the impact of the discharging foam stream on the fuel surface. Application rate and discharge duration shall be in accordance with the chart for fixed foam application discharge devices. Fig. 12 shows a typical dike protection system using automatic oscillating monitors. The minimum application time and discharge durations for fixed foam application discharge devices on a diked area involving hydrocarbons is per the following table. Type of Foam Minimum Application Rate Minimum Discharge Time (min.) Discharge Outlet Class I CLASS II gpm/ft 2 [(L/min.)/m 2 ] Hydrocarbon Hydrocarbon Fixed low-level 0.10 (4.1) 30 20 foam discharge outlets Foam monitors 0.16 (6.5) 30 20

3 FIG - 11 DIKE PROTECTION

4 FIG - 12 DIKE PROTECTION

5 HORIZONTAL STORAGE TANK TO ADDITIONAL PROTECTED AREAS DIRECTIONAL SPRAY NOZZLES (TYP) DIKE WALL HORIZONTAL STORAGE TANK PROPORTIONING SYSTEM PRODUCT TRANSFER PUMP EXAMPLE OF BLADDER TANK SYSTEM FOR FLAMMABLE LIQUID STORAGE USING OVERHEAD SPRAY NOZZLES FLAMMABLE LIQUID PRODUCT LINE

6 TANK AND DIKE PROTECTION