GMD 13 New gravimetric measuring system with evaluation on location

Similar documents
CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19 July Köln, 17 August 2012

testo 338 Portable Soot and Particulate Meter Versatile, digital display of particulates

LEAKAGE CLASS ACHIEVED? Wöhler DP 700 LEAKAGE TEST ON VENTILATION SYSTEMS AND COMPONENTS. The Measure of Technology GRAPHIC COLOR DISPLAY GRAPHIC

VELOCICALC MULTI-FUNCTION VENTILATION METER MODEL 9565

Pursuing high precision, speed, and ease of use

VITLAB Dispenser. Standard Operating Procedure (SOP)

Dispensette. Testing Instructions (SOP) 1. Introduction. May 2009

Lethabo Power Station Units No. 1 to 6 Particulate Emission Monitor Correlations, Unit No. 4 Start-up & Unit No. 6 Shutdown Report

Operational Experience with Startup Optimization for Steam Boilers. E.ON s Staudinger, Heyden, Ingolstadt und Zolling Power Plants

ISO INTERNATIONAL STANDARD

Air Flow Measurement Technologies

Certificate: / 22 March 2013

better measurement Simply a question of

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

PREFACE. Dear customer,

DaimlerChrysler Alternative Particulate Measurement page 1/8

Instruction Manual. Vibration Calibrator VC20. Manfred Weber. Metra Mess- und Frequenztechnik in Radebeul e.k. Meissner Str D Radebeul

Copyright Statement FPC International, Inc

better measurement Simply a question of

CEMS FOR COAL FIRED POWER STATIONS DEVICE CALIBRATION AND MAINTENANCE

Certificate: _01 / 29 April 2014

Orifice plates and nozzles. Flow measurement using differential pressure

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

OPTIMISING CHASSIS ALIGNMENT USING VEHICLE SENSORS

AVL Particle Measurement System Aviation

Dynamic DC Emulator Efficient testing of charging technology and power electronics

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

Heating chamber with mechanical convection

Heating chamber with mechanical convection

DPM-RT Operating Manual

Test procedure and Specifications for Particle Number Portable Emissions Measurement Systems (PN-PEMS)

ST Wiring diagram. Product description. Temperature controller. Order number

Mass Comparators Advanced Radwag solutions for traceability of measurement

Heating chamber with mechanical convection

Heating chamber with mechanical convection

GRAVIMAT SHC501 Gravimetric Dust Concentration Measuring System

EN. SKF Grease Spraying System For Large Open Gears. Extend the lifetime of large gear drives

Cross Flow Heat Exchanger H352

Viscosense 3. Viscosity Measurement & Control Systems. Product Bulletin TO BE REALLY SURE

M-11 MARINE DIESEL ENGINE FUEL INJECTOR

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Material Specification Note: Products may vary slightly from equipment shown in pictures

Superstatic 440. Static Heat- and Cooling Meter. Application

Duct filter units. Duct HEPA filter units AKF

Transferpette. Testing Instructions (SOP) 1. Introduction. October 2013

Excellence Level. Excellence XSR Balances Discover Efficiency in Daily Weighing

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

Digimar 816 CL. Versatile. User-friendly operation... The measuring program... Precise measuring results...

mass flowmeter for compressed air

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

HP5. Heated Probe. Main characteristics. Heated Probe for Micropollutants sampling

where nature and technology meet FILTRATION Solutions for filtration applications PETROGAS GAS-SYSTEMS BV

AVL PLU 131U FLOW METER

Copyright Statement FPC International, Inc

Technical Specifications

Is Low Friction Efficient?

Instruction Manual. Coating Thickness Gauge. Optionally with Memory

PRODUCT INFORMATION SHEET

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

Table 0.1 Summary Pollutant Discharge Test Results Engine Manufacturer. Number 24652

Dispersed Water in Jet Turbine Fuels: Negating the Effect on Particle Counting

Jet Fuel Conductivity Analysers & Additive Management systems

TESTING OF AUTOMOBILE VW GOLF OPERATING ON THREE DIFFERENT FUELS

User Manual for the RAMK Rotational Absolute Magnetic Kit Encoder

Trox-o-mat Automatic Roll Filters F1/1/EN/5

CIRCOGRAPH Sensor systems Rotating Head Ro 35 P Rotating Head Ro 35 L

LTG Air Distribution. Product Overview

ViscoSense 3D. Viscosity & Density Measurement Enabling Mass Flow Measurement. Product Bulletin TO BE REALLY 1 SURE

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Operating instructions

ACOUSTIC CLEANING SYSTEMS. Information Brochure.

Heating oven with mechanical control

testing and measuring instruments for vehicle wheels

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Cross Flow Heat Exchanger H352

The influence of Air Nozzles Shape on the NOx Emission in the Large-Scale 670 MWT CFB Boiler

SHOCK ABSORBER/DAMPER TESTING MACHINE

Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

APPLICATION VAPODEST ALCOHOL IN BEVERAGES AND INTERMEDIATES

Innovative Testing Equipment. Torque sensors Vehicle Applications Actuators

XK3190- A7. Weighing indicator USER MANUAL

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN

mass flowmeter for compressed air

Confirmation: / 22 March 2013

Portable pressure calibrator, Wally Box III Model CPH7600

E. Rodt 2 UBA Berlin Berlin Germany. EU / GRPE: "Particulate measurement program" (PMP)

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

Hybrid Drives for Mobile Equipment

Automatic Back-Flushing Filter for Process Technology AutoFilt RF3.

Hydraulic Deadweight Tester Model CPB5800

Safety drying ovens. Advantages: Areas of application: FDL series 115

Certificate: TNU112UML0348/ Test report: 112UML0348 / of 14 January 2013

Innovative Gearboxes for Wind Turbines

Technical Documentation. LTG Fine Filters. Type CDF / UDF

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1

SensoLyt 700 SensoLyt 700 SW

LTG Fine Filters Type CDF, Type UDF

Guide units. For toolmaking, fixture manufacturing and machine engineering

Electrohydraulic Drive System EHC-A

Transcription:

Dr. Födisch Umweltmesstechnik AG Zwenkauer Strasse 159 04420 Markranstädt Germany Phone: +49 34205 755-0 Fax: +49 34205 755-40 E-mail: sales@foedisch.de Internet: www.foedisch.de GMD 13 New gravimetric measuring system with evaluation on location Dr. Födisch Umweltmesstechnik AG 2002-2017 GMD 13 - Information Brochure - Version 1.0 - en, August 2017

Introduction Measurement of dust content can be necessary at industrial facilities for a number of reasons. At larger plants (e.g. power-generating, waste incineration and cement plants, for instance) there is the necessity of continuously monitoring waste gases for emissions content. At installations with a lower emissions potential, it is nonetheless necessary to check the concentrations of specific pollutants by means of individual measurements made at regular intervals. Measurements of dust content can also be performed in a similar manner on filter systems and separators, for the purposes of acceptance inspections and/or performance trials. Various measuring methods (e.g. optical or triboelectric) can be used for continuous measurement of dust concentration. All the measuring instruments used for this have in common that they need to be calibrated under specific plant conditions after installation and, generally, at intervals of three years subsequently. This calibration operation is performed by means of gravimetric control measurements, which are also used for the above mentioned individual measurements. For this purpose, a particle-laden sample of gas is taken under defined conditions from the waste gas flow and fed through a filter sleeve or a plane filter. The unladen weight of the filter is determined after its elaborate pre-conditioning. Conditioning is then repeated, and the weight of the laden filter then measured. This is normally done in an analytical laboratory. Every individual sampling operation on location normally takes 30 min. Not less than 15 samples taken on three days are necessary for control measurement for calibration purposes, during which the half-hourly averages of the continuously operating measuring instrument are recorded simultaneously. The necessary procedure is standardised under DIN EN 13284-1 and VDI 2066, Part 1, inter alia, in order to assure the obtainment of representative results. Immediate statement of the dust content at the plant is not possible during the measurements, however. The actual dust content can be stated only once the filters have been weighed under defined conditions in the analytical laboratory. This, under certain circumstances, can take several days. This time lag is unsatisfactory in some cases, particularly in the context of acceptance and/or control measurements abroad. Parallel evaluation in the immediate vicinity has remained impossible up to today, despite the fact that measurements of dust contents of this type have been performed since as long ago as the 19 th century. GMD 13 - Information Brochure - Version 1.0 - en, August 2017 3

Current state of the art The technological state of the art is characterised by the standard procedures and instruments from a range of suppliers and now in use for decades. It is necessary to differentiate between sampling systems, equipment for pre- and after-treatment of the samples, and the actual weighing systems. This standard reference-measurement procedure is described in detail in DIN EN 13284-1 and VDI 2066, Part 1. The principle of gravimetric measurement is shown in Figure 1. Before measurement is started, the filter holder or the plane filter from the measuring system is submitted to pre-treatment and then weighed. Under DIN EN 13284-1, the temperature in the drying cabinet for the filters and for any other items to be weighed should be 180 C, and cooling in the desiccator should extend for not less than eight hours. Since the difference between the weights measured before and after lading of the filters is used to determine dust content, DIN EN 13284-1 requires that aftertreatment be extremely similar. Drying after removal of the dust should take place for more than one hour at 160 C. The cooling time in the desiccator down to the temperature of the room in which weighing is performed should be eight hours. Other temperatures may be selected, depending on the properties of the particulate and, in particular, its thermal stability. Extractive sampling for the capture of particles must be conducted isokinetically. This means that the taking of the volumetric side-stream must be accomplished at approximately the same velocity as that of the main flow of waste gas, in order to preclude segregation phenomena during sampling. A nozzle diameter appropriate to the suction rates to be established must be used for this purpose. DIN EN 13284-1 requires the use of nozzles with a diameter of not less than 8 mm. Knowledge of flow conditions in the measuring cross-section is also required. Measurement using a pitot or Prandtl tube with a pressure-gauge connected must be performed if the waste gas velocity at the measuring point is not known. Total pressure and static pressure are read by the hook-shaped probe of the Prandtl tube, which faces into the waste-gas flow, and local velocity calculated from the differential pressure and gas density. Measurement is performed using a differential-pressure gauge. DIN EN 13284-1 requires that this measurement be made continuously, or at intervals of not longer than five minutes, during sampling. The value for the dry volume of gas for measurement suctioned off is available on the spot at the end of the measurement. Weight difference is determined following after-treatment of the filter in the laboratory. Dust concentration in mg/m³ (dry, standard temperature and pressure) is calculated using this and the volume of measuring gas suctioned off. The gravimetric dust measuring systems available on the market achieve, in combination with the laboratory equipment used, measuring accuracies ranging from approx. 0.1 to 1 mg/m³. Thermo element Prandtl tube Filter head with filter holder resp. plane filter Rotameter Sampling nozzle Upward flow Sampling pump with bypass control Gas flow meter Drying tower with showing steam trap Fig. 1: Gravimetric measurement according to DIN EN 13284-1 4 Dr. Födisch Umweltmesstechnik AG 2002-2017

The gravimetric measuring system GMD 13 The GMD 13 of Dr. Födisch Umweltmess technik AG is a compact and high-grade automated system for isokinetic gravimetric dust measurement in exhaust ducts and stacks in dependence on DIN EN 13284-1. The system is a further development of the established GMD series, which has been successfully marketed by Dr. Födisch Umweltmess technik AG for the purpose of gravimetric control measurements for a number of years now. The device s integrated hot-weighing system makes it the world s first measuring system to enable the user to state information on the dust concentration measured gravimetrically only a short time after measurement. Additional laboratory equipment for gravime tric measurement is then no longer necessary; transport and the necessary time are therefore also eliminated. The simple and reliable structure of the system, in combination with the project-orientated software package, also minimises error sources during measurement. Sample probes Measuring unit Pump Filter element Precision hot balance Fig. 2: The gravimetric measuring system GMD 13 GMD 13 - Information Brochure - Version 1.0 - en, August 2017 5

Measuring installation at dust sampling By means of the GMD 13 the measuring gas velocity, the measuring gas pressure and the sampled measuring gas volume are registered. Besides, the measuring gas humidity can be measured by a separate sample probe. Consequently, all relevant parameters for determination of dust content are registered by the system on standard conditions and the measuring gas sampling is regulated fully automatic isokinetic. The equipment s control system features two additional ma measuring inputs (0-20 ma). These can be used during sampling to record the measured data supplied by any automatic dust-measuring systems installed, thus eliminating the need for a separate recorder. In the case of plants on which no continuous measuring system is installed, it is also possible to operate a directly indicating dust-measuring instrument or a dust sensor in parallel (e.g. the PFM 13 C of Dr. Födisch Umweltmesstechnik AG). This instrument is actively supplied at 24 V by the GMD 13. By parallel operation operational system modifications can be automatically registered and analysed. PFM 13 C (optional) Sample probe Upward flow Measuring unit Pump Fig. 3: Measuring installation at dust sampling (optionally with PFM 13 C) 6 Dr. Födisch Umweltmesstechnik AG 2002-2017

Hot weighting on location The new gravimetric measuring system GMD 13 permits easy and safe handling of the complete system on location. The precision hot balance is kept in its carrying case for transportation. The essential advancement of the GMD 13 is the patented method of hot weighting of the filter integrated in the measuring system. Thereby the extensive conditioning before and after the dust sampling does not apply and there is the possibility to determine the measured dust content promptly still on location. Conditioning is now superfluous, because the filter is heated so intensively during weighing that its entire water content is expelled. The filter can be heated to up to 160 C during the weighing operation using the precision hot balance. Fig. 4: Precision hot balance with carrying case The used filters consist of pressed fibre glass and require extremely careful handling. To assure this, the used filer is protected by a robust filter holder which is weighed together with the filter during hot weighing. The weighting of the complete filter element is admissible according to DIN EN 13284-1. Filter holder Filter Filter holder head Fig. 5: Filter element GMD 13 - Information Brochure - Version 1.0 - en, August 2017 7

Value accuracy Before weighing, the precision hot balance is tared and connected directly to the control system of GMD 13 on the measuring unit. Weighing using the precision hot balance is performed prior to and after gravimetric measurement in a clean, draft-free and vibration-free room (e.g. office, workshop, hotel room). The control system guides the user through the weighing process, and receives the measured data. No settings on the precision hot balance are necessary. Weighing is performed semi-automatically at an accuracy of less than 1.0 mg. Completion of weighing is signalised by means of an audible tone. By multiple weighting of the same filter element the weighing accuracy can be improved to 0.4 mg with passable expenditure of time. Already after approx. 3 to 5 weightings a steady average value results, so that precise measuring results can be achieved. Figure 6 shows typical measuring values of a multiple weighting at two measuring days with 11 weighting in each case. Already after the 5 th repetition weighting the weighing difference of the determined average values lies under 0.25 mg. Even larger variations, for example by the large deviation of a single weighting (see marking), affect the average value non-significant. The time requirement for the first weighing operation varies between 5 and 30 minutes, and the time necessary for further weighing operations between 3 and 15 minutes per operation. 1.0 Deviation from nominal value [mg] Deviation from nominal value [mg] 0.5 0.0-0.5-1.0 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 Number of weighting (weightings at 1 st day) Number of weighting (weightings at 2 nd day) Current weighting Average value about single weightings Marking of larger variations of a weighting Fig. 6: Improvement in weighing accuracy via multiple weighing of one filter element 8 Dr. Födisch Umweltmesstechnik AG 2002-2017

Project-based software The software, which has been revised compared to previous models, acts project-based. By different filters all measurements and settings of a measuring point are summarised in a project and evaluated together. Besides, the results of a weighting according to DIN EN 13284-1, can be input into the measuring unit and used for evaluation. At dust sampling, the pressure drop across the filter and, optionally, the signals on the ma inputs during measurement, can be shown in graphic form on the measuring unit s display. The device s measured data can be outputted on location, or written to a CompactFlash memory card, to permit their further use on a PC. Fig. 7: Display of measuring unit of GMD 13 at dust sampling GMD 13 - Information Brochure - Version 1.0 - en, August 2017 9

Measuring procedure and results The procedure for gravimetric measurement using the GMD 13 is as follows: 1. Creation of a new project and planned filters/ measurements using the instrument s software; preparation of the required filter holders with the filters 2. Placement of the precision hot balance in a dry, draft-free, vibration-free place 3. Weighing of the filter holders and filters using the precision hot balance 4. Installation of the measuring system at the dust sampling point 5. Measurement of absolute moisture content in the waste gas at the dust sampling point using the moisture probe and/or adoption of a known measured value and entry of gas parameters (O 2, CO 2 ) 6. Measurement of waste gas velocity using the dust probe and installation of the sampling nozzle The GMD 13 supports selection of a suitable sampling nozzle. 7. Entry of the boundary parameters for measurement (measuring time, cross-section, flange depth, measuring points) 8. Insertion of the filter element into the filter mounting of the dust sampling probe 9. Start of measurement / dust sampling Any change of measuring points is acoustically signalised and visually displayed, depending on specification. 10. Repetition of measurements using other filter elements (as described in steps 8 and 9) 11. Weighing of the filter elements using the precision hot balance (same balance, same weighing place) 12. Computation of the results of the dust sampling by the GMD 13 The results are outputted on the display, by means of a printer, or by means of read-out of the CompactFlash memory card on a PC. Figure 8 shows a comparison of the dust concentrations determined by means of hot weighing using the GMD 13 and by means of weighing in accordance with DIN EN 13284-1 (32 measurements at the dust duct). Dust concentration [mg, ntr.] Weighting according to DIN EN 13284-1 Hot weighting with GMD 13 Fig. 8: Dust concentration, comparison of weighing procedures of GMD 13 and according to DIN EN 13284-1 10 Dr. Födisch Umweltmesstechnik AG 2002-2017

Conclusion The GMD 13 of Dr. Födisch Umweltmesstechnik AG is a compact and highly automated system for isokinetic gravimetric measurement of dust content in waste gas ducts and stacks. All relevant variables are registered under standardised conditions for determination of dust content and measuring gas sampling is isokinetically regulated fully automatically. The system s simple and reliable structure, in conjunction with the project-based software used, assure accurate measuring results. The device is the first measuring system in the world featuring integrated hot weighing and the capability for evaluation on locacion with no additional laboratory equipment. It also permits operation in parallel with a directly indicating dust-measuring instrument and/or a dust sensor, so that system changes caused by operating conditions can be automatically registered and evaluated. GMD 13 - Information Brochure - Version 1.0 - en, August 2017 11

Dr. Födisch Umweltmesstechnik AG Zwenkauer Strasse 159 04420 Markranstädt Germany Phone: +49 34205 755-0 Fax: +49 34205 755-40 E-mail: sales@foedisch.de Internet: www.foedisch.de Dr. Födisch Umweltmesstechnik AG 2002-2017