Similar documents
MTE AC Line / Load Reactors Price book

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

AC Line / Load Reactors

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

MOTOR PROTECTION Sine Wave 2-8 khz Series A Filter Table of Contents

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

RLW. Reactors. mtecorp.com. Smaller, lighter protection. Power quality. Solved.

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation

PRODUCT SPECIFICATIONS

MATRIX FILTER USER MANUAL. SERIES D 400 Volts, 50HZ PART NO. INSTR 025 REL REV MTE Corporation

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

MATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation

Since then, products have been introduced and expanded to include:

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

1321 Power Conditioning Products

Description Reactor, Open; 460 V 3 Phase; Power Rating 30 HP; Impedance 3 Percent; Inductance 0.7 Millihenry; Baldor Brand; Current Rating 45 Ampere

2 SLR Series Line Reactors... 50

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)

RLW Reactors. Product Selector. Smaller. Lighter. mtecorp.com. Proven performance in the field. Reliable and economical. Compact and light-weight

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Features, Benefits and Functions

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

1329I Integrated Drive/Motor CE Filter Option Kit

dv Sentry Product Selector dv/dt Filters mtecorp.com Ln Line Side Ld Load Side The future is here. Power quality. Solved.

Single-Phase Ventilated

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Three-Phase Ventilated

DATA SHEET CP MOTORIZED PUMP UNITS 3CP1120, 3CP1130, 3CP1140 5CP2140WCS, 5CP2150W

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

Description 1/8-7.5HP

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Inverter Speed Ratio Information

High Frequency SineWave Guardian TM

BR Second Position Voltages. AA Fourth Position

SECTION 3 HPS CENTURION R REACTORS AND RC DV/DT FILTERS

Overload Relay Heater Tables

Jefferson Electric Class I Division 2 Transformers for hazardous locations

Totally Enclosed Non-Ventilated

Attachment A: Liquefied Natural Gas Pump Specifications

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

Packaged Drives and Engineered Systems

Max. Input Power (W) Input Current. Inrush 347V Vin 60/ C. 480V Vac Vin 85 / 115. Dimming Method.

AF40... AF96 3-pole contactors Technical data

Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Description

Product Information Packet VEM3665T 5HP,1755RPM,3PH,60HZ,184TC,0642M,TEFC,F1

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers

SECTION MOTOR REQUIREMENTS for HVAC

HVAC Drives Lenze AC Tech MCH Series Price Book May US Dollars

Variable Speed Product Line

Product Information Packet M1509T 7.5/3.8HP,1740/860RPM,3PH,60HZ,215T,3754

Product Information Packet CFM3146A .75HP,1140RPM,3PH,60HZ,56YZ,3520M,OPEN

Dry Type Distribution Transformers

Technical data OT16E3 OT160E3 UL & CSA

Product Information Packet EM4313T 75HP,3550RPM,3PH,60HZ,365TS,1464M,TEFC,F

TECHNICAL BROCHURE BAQUACPC. Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

Product Information Packet VM HP,1725RPM,3PH,60HZ,56C,3413M,TEFC,F1

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

IDNM3581T 1HP,1745RPM,3PH,60HZ,143TC,0524M,TENV,F1

Product Information Packet CFM3166A 1.5HP AIROVER,1140RPM,3PH,60HZ,56YZ,OPAO

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

Product Information Packet IDNM3587T 2HP,1755RPM,3PH,60HZ,145TC,0535M,TENV,F1

IDNM3661T 3HP,1760RPM,3PH,60HZ,184TC,0636M,TENV,F1

Phoenix Manufacturing, Inc E. Roeser Rd. Phoenix, AZ phoenixmanufacturing.com

BRAQCPC IT T. Goulds Pumps AQUAVAR CPC. Variable Speed Centrifugal Pump Controller. Engineered for life

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Product Information Packet L1317A 2HP,3450RPM,1PH,60HZ,56/56H,3528L,OPEN

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

Single Phase Poultry Fan Motor, Standard Efficiency,TEAO, Squirrel Cage Rotor

Product Information Packet M3161TA 3HP,1725RPM,3PH,60HZ,56HZ,3540M,OPEN,F1

Product Information Packet EM3611T 3HP,1760RPM,3PH,60HZ,182T,3632M,TEFC,F1

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual

Delta Products VFD CP2000 Bypass Control Packages.

IZT2S32SC 2 Lamp 32/T8 Dimmable Ballast

Product Information Packet RHM445A .75 OPAOHP,1725RPM,3PH,60HZ,56,3420M,OP

JARD by MARS JARD by MARS

Sensorless Vector Drives

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.

DATA SHEET. Three Phase Induction Motor - Squirrel Cage. Customer : Product code : : W22 NEMA Premium Efficiency Three-Phase

HPS Centurion R Reactor. Why Choose a Reactor? Connection Diagram

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base

Product Information Packet IDM3581T 1HP,1765RPM,3PH,60HZ,143TC,0524M,TEBC,F1

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

AF series contactors (9 2650)

Input Current (Amps) Input Power (ANSI Watts)

Product Information Packet IDM3587T 2HP,1755RPM,3PH,60HZ,145TC,0533M,TEBC,F1

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects

Product Information Packet CM7006A .5HP,1725RPM,3PH,60HZ,56C,X3416M,XPFC,F1

Industrial Control Transformers

Product Information Packet CL3612TM 5HP,1725RPM,1PH,60HZ,184TC,3646LC,TEFC

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Transcription:

Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 INTRODUCTION...3 LIST PRICE / CROSS REFERENCE...4 SELECTION & LIST PRICE...5 208 VOLTS (60 HZ)...5 240 VOLTS (60 HZ)...6 400 VOLTS (60 HZ)...7 480 VOLTS (60 HZ)...8 600 VOLTS (60 HZ)...9 PRODUCT OPTIONS...10 PRODUCT SPECIFICATIONS...12 APPROVALS:...12 INSULATION SYSTEM:...12 MODEL CODE PART NUMBER CONFIGURATION...13 DIMENSIONS...14 OPEN FRAME 1...15 OPEN FRAME 2...15 TECHNICAL DATA...16 ENCLOSURE DRAWINGS...17 FIG 4 CAB -8...17 FIG 5 CAB 13V...17 FIG 6 CAB 12C...18 PB-1600-1

Standard Delivery Schedule Effective: May 16, 2005 Standard Open Type (catalog items) Stock to 1 week (Quantity 1-10) Stock to 3 weeks (Quantity 11-20) Consult factory for larger quantities 1 thru 32 amps Standard Open Type (catalog items) Stock to 2 ½ weeks (Quantity 1-10) Stock to 4 weeks (Quantity 11-20) Consult factory for larger quantities 40 thru 92 amps Standard Open Type (catalog items) 3-4 weeks (Quantity 1-4) 3-6 weeks (Quantity 5-9) Consult factory for larger quantities 110 thru 200 amps PB-1600-2

Introduction DCA Link Chokes DC link chokes help reduce AC input harmonics that occur on VFD drive / inverters. The series A DC link choke is a cost effective alternative to many popular MTE RB DC link chokes. The following cross reference and HP selection tables identify where the DCA product may be used. For DC link applications not shown here use PB-1601 for the standard RB listings. New for the DCA is the addition of NEMA 1 and NEMA 3R enclosures. PB-1600-3

List Price / Cross Reference MTE RB DCA Link Link chokes Chokes List Price 2RB004 DCA000204 $39 4RB002 DCA000402 $39 4RB003 DCA000403 $41 4RB004 DCA000404 $53 9RB002 DCA000902 $41 9RB003 DCA000903 $60 9RB004 DCA000904 $72 12RB001 DCA001201 $37 12RB002 DCA001202 $57 12RB003 DCA001203 $62 12RB004 DCA001204 $71 18RB001 DCA001801 $41 18RB002 DCA001802 $57 18RB003 DCA001803 $71 18RB004 DCA001804 $81 18RB005 DCA001805 $117 25RB003 DCA002503 $70 25RB004 DCA002504 $73 25RB005 DCA002505 $135 32RB001 DCA003201 $72 32RB002 DCA003202 $101 32RB003 DCA003203 $145 40RB001 DCA004001 $70 40RB002 DCA004002 $74 40RB003 DCA004003 $107 40RB004 DCA004004 $216 50RB001 DCA005001 $95 50RB003 DCA005003 $169 50RB004 DCA005004 $258 62RB001 DCA006201 $76 62RB002 DCA006202 $130 80RB002 DCA008002 $136 80RB005 DCA008005 $384 92RB001 DCA009201 $103 92RB002 DCA009202 $258 92RB003 DCA009203 $406 110RB002 DCA011002 $196 110RB003 DCA011003 $260 125RB002 DCA012502 $189 150RB002 DCA015002 $257 150RB004 DCA015004 $636 200RB002 DCA020002 $403 NEMA 1 and NEMA 3R enclosures are available for the above reactors. See page PB-1600-13 for part number configuration and pages PB-1600-10 to PB-1600-11 for details on specifying these enclosures PB-1600-4

Selection & List Price 208 Volts (60 HZ) HP 3% Impedance 5% Impedance Motor Cat. No. Price Cat. No. Price 0.25 - - DCA000204 $39 0.5 DCA000402 $39 DCA000403 $41 0.75 - - DCA000402 $39 1 - - DCA000402 $39 1.5 DCA000902 $41 DCA000903 $60 2 DCA001202 $57 DCA000903 $60 3 DCA001802 $57 DCA001203 $62 5 - - DCA001802 $57 7.5 DCA003201 $72 DCA003203 $145 10 DCA004002 $74 DCA004003 $107 15 DCA006201 $76 DCA005003 $169 20 - - - - 25 - - - - 30 - - DCA011002 $260 40 - - DCA012502 $189 50 - - DCA015002 $257 60 - - DCA020002 $403 75 - - - - 100 - - - - NEMA 1 and NEMA 3R enclosures are available for the above reactors. See page PB-1600-13 for part number configuration and pages PB-1600-10 to PB-1600-11 for details on specifying these enclosures PB-1600-5

Selection & List Price 240 Volts (60 HZ) HP 3% Impedance 5% Impedance Motor Cat. No. Price Cat. No. Price 0.25 - - DCA000204 $39 0.5 DCA000402 $39 DCA000403 $41 0.75 - - DCA000402 $39 1 - - DCA000402 $39 1.5 DCA000902 $41 DCA000903 $60 2 DCA000902 $41 DCA000903 $60 3 DCA001202 $57 DCA001203 $62 5 DCA001802 $57 DCA001803 $71 7.5 DCA003201 $72 DCA003202 $101 10 DCA004002 $74 DCA004003 $107 15 DCA005001 $95 - - 20 DCA008002 $136 - - 25 - - - - 30 - - DCA011003 $260 40 DCA012502 $189 - - 50 - - - - 60 - - DCA020002 $403 75 - - - - 100 - - - - NEMA 1 and NEMA 3R enclosures are available for the above reactors. See page PB-1600-13 for part number configuration and pages PB-1600-10 to PB-1600-11 for details on specifying these enclosures. PB-1600-6

Selection & List Price 400 Volts (60 HZ) HP 3% Impedance 5% Impedance Motor Cat. No. Price Cat. No. Price 0.25 - - - - 0.5 DCA000204 $39 DCA000204 $39 0.75 - - DCA000204 $39 1 DCA000403 $41 DCA000404 $53 1.5 DCA000403 $41 DCA000404 $53 2 DCA000904 $72 DCA000904 $72 3 DCA000903 $60 DCA000904 $72 5 DCA001203 $62 DCA001204 $71 7.5 DCA001804 $81 DCA001805 $117 10 DCA002503 $70 DCA002505 $135 15 DCA003202 $101 DCA003203 $145 20 DCA004003 $107 DCA004004 $216 25 - - DCA005003 $169 30 - - - - 40 - - DCA008005 $384 50 DCA009202 $258 DCA009203 $406 60 DCA011002 $196 DCA011003 $260 75 - - DCA015004 $636 100 DCA020002 $403 - - NEMA 1 and NEMA 3R enclosures are available for the above reactors. See page PB-1600-13 for part number configuration and pages PB-1600-10 to PB-1600-11 for details on specifying these enclosures PB-1600-7

Selection & List Price 480 Volts (60 HZ) HP 3% Impedance 5% Impedance Motor Cat. No. Price Cat. No. Price 0.25 - - - - 0.5 DCA000204 $39 DCA000204 $39 0.75 - - DCA000204 $39 1 DCA000403 $41 DCA000404 $53 1.5 DCA000403 $41 DCA000404 $53 2 DCA000904 $72 DCA000904 $72 3 DCA000903 $60 DCA000904 $72 5 DCA001203 $62 DCA001204 $71 7.5 DCA001804 $81 DCA001805 $117 10 DCA002503 $70 DCA002505 $135 15 DCA003202 $101 DCA003203 $145 20 DCA004003 $107 DCA004004 $216 25 - - DCA005003 $169 30 - - - - 40 - - DCA008005 $384 50 DCA009202 $258 DCA009203 $406 60 DCA011002 $196 DCA011003 $260 75 - - DCA015004 $636 100 DCA020002 $403 - - NEMA 1 and NEMA 3R enclosures are available for the above reactors. See page PB-1600-13 for part number configuration and pages PB-1600-10 to PB-1600-11 for details on specifying these enclosures PB-1600-8

Selection & List Price Series A DC Link Choke 600 Volts (60 HZ) HP 3% Impedance 5% Impedance Motor Cat. No. Price Cat. No. Price 0.25 - - - - 0.5 - - - - 0.75 DCA000204 $39 DCA000204 $39 1 DCA000204 $39 DCA000204 $39 1.5 DCA000404 $53 DCA000404 $53 2 DCA000404 $53 DCA000404 $53 3 DCA000904 $72 DCA000904 $72 5 DCA000904 $72 DCA000904 $72 7.5 DCA001204 $71 DCA001204 $71 10 DCA001803 $71 DCA001804 $81 15 DCA002505 $135 DCA002505 $135 20 DCA003203 $145 DCA003203 $145 25 DCA003203 $145 DCA003203 $145 30 DCA004003 $107 DCA004004 $216 40 DCA005003 $169 DCA005004 $258 50 - - - - 60 - - DCA008005 $384 75 DCA009203 $406 DCA009203 $406 100 - - - - NEMA 1 and NEMA 3R enclosures are available for the above reactors. See page PB-1600-13 for part number configuration and pages PB-1600-10 to PB-1600-11 for details on specifying these enclosures PB-1600-9

Product Options DCA 1_ adds an enclosure to the DCA reactor to comply with NEMA1 requirements. Listed weights and prices are for the completed assembly. DCA NEMA1 NEMA 1 Enclosed Enclosed P.N. Enclosure Weight # Figure List Price DCA000214 CAB -8 9 Fig. 4 $118 DCA000412 CAB -8 9 Fig. 4 $118 DCA000413 CAB -8 9 Fig. 4 $120 DCA000414 CAB -8 11 Fig. 4 $132 DCA000912 CAB -8 9 Fig. 4 $120 DCA000913 CAB -8 11 Fig. 4 $140 DCA000914 CAB -8 14 Fig. 4 $152 DCA001211 CAB -8 8 Fig. 4 $116 DCA001212 CAB -8 9 Fig. 4 $137 DCA001213 CAB -8 11 Fig. 4 $142 DCA001214 CAB -8 14 Fig. 4 $151 DCA001811 CAB -8 9 Fig. 4 $120 DCA001812 CAB -8 11 Fig. 4 $137 DCA001813 CAB -8 14 Fig. 4 $151 DCA001814 CAB -8 15 Fig. 4 $162 DCA001815 CAB -13V 31 Fig. 5 $249 DCA002513 CAB -8 14 Fig. 4 $150 DCA002514 CAB -8 12 Fig. 4 $153 DCA002515 CAB -13V 31 Fig. 5 $268 DCA003211 CAB -8 12 Fig. 4 $152 DCA003212 CAB -13V 28 Fig. 5 $232 DCA003213 CAB -13V 32 Fig. 5 $278 DCA004011 CAB -8 12 Fig. 4 $150 DCA004012 CAB -8 14 Fig. 4 $154 DCA004013 CAB -8 15 Fig. 4 $189 DCA004014 CAB -13V 39 Fig. 5 $353 DCA005011 CAB -8 15 Fig. 4 $176 DCA005013 CAB -13V 33 Fig. 5 $303 DCA005014 CAB -13V 43 Fig. 5 $397 DCA006211 CAB -13V 26 Fig. 5 $206 DCA006212 CAB -13V 32 Fig. 5 $263 DCA008012 CAB -13V 32 Fig. 5 $269 DCA008015 CAB -13V 53 Fig. 5 $529 DCA009211 CAB -13V 28 Fig. 5 $234 DCA009212 CAB -13V 41 Fig. 5 $397 DCA009213 CAB -13V 50 Fig. 5 $552 DCA011012 CAB -13V 40 Fig. 5 $332 DCA011013 CAB -13V 40 Fig. 5 $399 DCA012512 CAB -13V 41 Fig. 5 $324 DCA015012 CAB -13V 41 Fig. 5 $396 DCA015014 CAB -13V 70 Fig. 5 $794 DCA020012 CAB -13V 57 Fig. 5 $549 PB-1600-10

Product Options DCA 3_ adds an enclosure to the DCA reactor to comply with NEMA 3R wet outdoor requirements. Listed weights and prices are for the completed assembly. DCA NEMA3R NEMA 3R Enclosed Enclosed P.N. Enclosure Weight # Figure List Price DCA000234 CAB 12C 70 Fig. 6 $562 DCA000432 CAB 12C 70 Fig. 6 $562 DCA000433 CAB 12C 70 Fig. 6 $564 DCA000434 CAB 12C 72 Fig. 6 $576 DCA000932 CAB 12C 70 Fig. 6 $564 DCA000933 CAB 12C 72 Fig. 6 $584 DCA000934 CAB 12C 75 Fig. 6 $596 DCA001231 CAB 12C 69 Fig. 6 $560 DCA001232 CAB 12C 70 Fig. 6 $581 DCA001233 CAB 12C 72 Fig. 6 $586 DCA001234 CAB 12C 75 Fig. 6 $595 DCA001831 CAB 12C 70 Fig. 6 $564 DCA001832 CAB 12C 72 Fig. 6 $581 DCA001833 CAB 12C 75 Fig. 6 $595 DCA001834 CAB 12C 76 Fig. 6 $606 DCA001835 CAB 12C 81 Fig. 6 $693 DCA002533 CAB 12C 75 Fig. 6 $594 DCA002534 CAB 12C 73 Fig. 6 $597 DCA002535 CAB 12C 81 Fig. 6 $712 DCA003231 CAB 12C 73 Fig. 6 $596 DCA003232 CAB 12C 78 Fig. 6 $676 DCA003233 CAB 12C 82 Fig. 6 $722 DCA004031 CAB 12C 73 Fig. 6 $594 DCA004032 CAB 12C 75 Fig. 6 $598 DCA004033 CAB 12C 76 Fig. 6 $633 DCA004034 CAB 12C 89 Fig. 6 $797 DCA005031 CAB 12C 76 Fig. 6 $620 DCA005033 CAB 12C 83 Fig. 6 $747 DCA005034 CAB 12C 93 Fig. 6 $841 DCA006231 CAB 12C 76 Fig. 6 $650 DCA006232 CAB 12C 82 Fig. 6 $707 DCA008032 CAB 12C 82 Fig. 6 $713 DCA008035 CAB 12C 103 Fig. 6 $973 DCA009231 CAB 12C 78 Fig. 6 $678 DCA009232 CAB 12C 91 Fig. 6 $841 DCA009233 CAB 12C 100 Fig. 6 $996 DCA011032 CAB 12C 90 Fig. 6 $776 DCA011033 CAB 12C 90 Fig. 6 $843 DCA012532 CAB 12C 91 Fig. 6 $768 DCA015032 CAB 12C 91 Fig. 6 $840 DCA015034 CAB 12C 120 Fig. 6 $1,238 DCA020032 CAB 12C 107 Fig. 6 $993 PB-1600-11

Product Specifications Approvals: Maximum Voltage: Ampere Ratings: Overload Rating: Maximum Altitude: Temperature Rise: Maximum Ambient: Component Recognition: (Open Units Only) Per UL 508, cul per CSA C22.2 14-M91 1000 Volts DC 4 amps thru 200 amps standard 150 % of max RMS current for 1 minute 1000 meters 85 C by TC & 105 C by resistance except as noted. 125 C by TC & 145 C by resistance part numbers DCA008005, DCA009203, DCA015004 and DCA020002 50 C open chokes 40 C enclosed chokes Insulation System: Ripple Current: Selection Basis: UL Class 155 except as noted UL Class 200 part numbers DCA008005, DCA009203, DCA015004 and DCA020002 10% p-p at 360 Hz maximum DC amps, RMS amps Thermal Current: DC amps x 1.0353 PB-1600-12

Model Code Part Number Configuration Model Number Code System: DC A X X YYY DC Link Choke Series A Current Rating (i.e. 0005 is 5 Amps) Mechanical Configurations 0 = Base Mount 1 = NEMA 1 or 2 3 = NEMA 3R Reactor Relative Impedance no. 1,2,3,4 (1) is lowest value Options: 001 = First Option PB-1600-13

Dimensions Cat. No. Figure A B C D E F DCA000204 1 3.75 3.25 2 N/A 3.13.187 DIA DCA000402 1 3.75 3.25 2 N/A 3.13.187 DIA DCA000403 1 3.75 3.25 2 N/A 3.13.187 DIA DCA000404 2 3.81 4.5 2.82 2 3.13.203 X.328 DCA000902 1 3.75 3.25 2 N/A 3.13.187 DIA DCA000903 2 3.81 4.5 2.82 2 3.13.203 X.328 DCA000904 2 4.63 5.25 4 2.5 3.73.203 X.328 DCA001201 1 3.75 3.25 1.75 N/A 3.13.187 DIA DCA001202 2 3.81 4.5 2.82 2 3.13.203 X.328 DCA001203 2 3.81 4.5 2.82 2 3.13.203 X.328 DCA001204 2 4.63 5.25 3.5 2 3.75.203 X.328 DCA001801 1 3.75 3.25 2 N/A 3.13.187 DIA DCA001802 2 3.81 4.5 2.82 2 3.13.203 X.328 DCA001803 2 3.81 4.5 3.75 3 3.13.203 X.328 DCA001804 2 4.63 5.25 4 2.5 3.75.203 X.328 DCA001805 2 4.63 5.25 5.25 4 3.75.203 X.328 DCA002503 2 3.81 4.5 3.75 3 3.13.203 X.328 DCA002504 2 3.81 4.5 3 2.5 3.13.203 X.328 DCA002505 2 4.63 5.25 5.25 4 3.13.203 X.328 DCA003201 2 3.81 4.5 3.32 2.5 3.13.203 X.328 DCA003202 2 4.63 5.25 4.25 3 3.75.203 X.328 DCA003203 2 4.63 5.25 5.25 3 3.75.203 X.328 DCA004001 2 3.81 4.5 3 2.5 3.13.203 X.328 DCA004002 2 3.81 4.5 3.75 3 3.13.203 X.328 DCA004003 2 4.63 5.25 4 2.5 3.75.203 X.328 DCA004004 2 6.5 6.55 6 3.38 5.31.28 X.52 DCA005001 2 4.63 5.25 4 2.5 3.75.203 X.328 DCA005003 2 4.63 5.25 5.25 4 3.75.203 X.328 DCA005004 2 6.5 5.5 6 3.38 5.31.28 X.52 DCA006201 2 4.63 4 5 2.5 3.75.203 X.328 DCA006202 2 4.63 4 7.25 4 3.75.203 X.328 DCA008002 2 4.63 4 6.5 4 3.75.203 X.328 DCA008005 2 DCA009201 2 4.63 4 6 3 3.75.203 X.328 DCA009202 2 6.5 5.5 6.75 3.75 5.31.281 X.562 DCA009203 2 6.5 5.5 7 4.63 5.31.281 X.562 DCA011002 2 6.5 5.5 6 3 5.31.281 X.562 DCA011003 2 6.5 5.5 6.63 3.63 5.31.281 X.562 DCA012502 2 6.5 5.5 6.5 3.31 5.31.281 X.562 DCA015002 2 6.5 5.5 7.5 3.38 5.31.281 X.562 DCA015004 2 DCA020002 2 7.5 6.5 9 3.63 6.75.281 X.562 PB-1600-14

Dimensions Open Frame 1 Open Frame 2 PB-1600-15

Technical Data Cat. No. DC Lug Unit weight mh Watts Torque Amps Size Pounds DCA000204 2 50 5 22-14 4.5 2 DCA000402 4 12 5 22-14 4.5 2 DCA000403 4 15 6 22-14 4.5 2 DCA000404 4 25 9 18-4 20 4 DCA000902 9 3.22 7 22-14 4.5 2 DCA000903 9 7.5 11 18-4 20 4 DCA000904 9 11.5 16 18-4 20 7 DCA001201 12 1 5 22-14 4.5 1 DCA001202 12 1 7 18-4 20 2 DCA001203 12 4 11 18-4 20 4 DCA001204 12 6 14 18-4 20 7 DCA001801 18 0.65 5 18-4 20 2 DCA001802 18 1.375 9 18-4 20 4 DCA001803 18 2.75 16 18-4 20 7 DCA001804 18 3.75 17 18-4 20 8 DCA001805 25 6 20 18-4 20 13 DCA002503 25 1.275 13 18-4 20 7 DCA002504 25 1.75 13 18-4 20 5 DCA002505 32 4 16 18-4 20 13 DCA003201 32 0.85 11 18-4 20 5 DCA003202 32 1.62 14 18-4 20 10 DCA003203 40 2.68 21 18-4 20 14 DCA004001 40 0.5 14 18-4 20 5 DCA004002 40 0.75 15 18-4 20 7 DCA004003 40 1 17 18-4 20 8 DCA004004 40 2 29 18-4 20 21 DCA005001 50 0.625 18 18-4 20 8 DCA005003 50 1.35 21 18-4 20 15 DCA005004 50 2 30 6-0 6-4(45) &2-0 (50) 25 DCA006201 62 0.32 17 6-0 6-4(45) &2-0 (50) 8 DCA006202 62 0.61 20 6-0 6-4(45) &2-0 (50) 14 DCA008002 80 0.4 25 6-0 6-4(45) & 2-0(50) 14 DCA008005 80 1.25 6-0 6-4(45) & 2-0(50) 35 DCA009201 92 0.2 19 6-0 6-4(45) & 2-0(50) 10 DCA009202 92 0.6 34 6-0 6-4(45) & 2-0(50) 23 DCA009203 92 1 48 6-0 6-4(45) & 2-0(50) 32 DCA011002 110 0.3 38 6-0 6-4(45) & 2-0(50) 22 DCA011003 110 0.45 45 6-0 6-4(45) & 2-0(50) 22 DCA012502 125 0.22 27 6-0 6-4(45) & 2-0(50) 23 DCA015002 150 0.22 36 2-0000 150 23 DCA015004 150 0.65 2-0000 150 52 DCA020002 200 0.21 50 2-0000 150 39 PB-1600-16

Enclosure Drawings NEMA 1 Fig 4 Cab -8 Fig 5 Cab 13V PB-1600-17

Enclosure Drawings NEMA 3R Fig 6 Cab 12C PB-1600-18

Revision Date Revision History --- 5/10/04 New document by Karl Hink 001 3/31/05 PB-1600 Revised by Wayne Walcott changed name from DC Link Choke to Series A DC Link Choke; made DC Link Choke PB-1601. 002 6/29/05 Rev. by WRW changed page 12 part no. to 9 digit 003 7/12/05 Rev. By WRW: qualify UL cul as recognized open units only 004 8/12/05 Rev. by WRW add DCA001204, DCA001214, DCA001234 005 11-02-05 Rev. by WRW added DCA001202, DCA001212 DCA001232, DCA001801, DCA001811 DCA001831 PB-1600-19