ELECTRICAL INSTALLATION PROCEDURES For Custom Grid Assemblies & Power Generators

Similar documents
MECHANICAL INSTALLATION PROCEDURES for Custom Grids and Support Framing

TRAC-Station BT Installation Instructions

CIRCLE SEAL CONTROLS

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to VAC, 3 HP to VAC without NEMA1 Enclosures

Start-up and Operation

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

Model 124 Filter Minder & Model 124

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

INSTALLATION INSTRUCTIONS

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

Sentinel Field Satellite Controller

ELECTRO-MECH SCOREBOARD CO.

1100 Series Piston Type Differential Pressure Gauges

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

CIRCLE SEAL CONTROLS

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

High Frequency SineWave Guardian TM

PDX and PX Retrofit Series

I-BFV.KIT Butterfly Valve Gear Operator Replacement

10 Commercial, Industrial, Agricultural Services

INSTALLATION MANUAL. Melink Corporation (513) Revision

Job Sheet 1 Installing the Net Watt-Hour Meter

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

E.S.P. Embedded Sensing Probes for Motor Brushes

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

SPACESAVER EC-300 A ELECTRICS

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5


Installation, Maintenance, and Operation Manual

ITS-50R TRANSFER SWITCH OWNER S MANUAL

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

Pneumatic Isolation Module

MA-5200 Series MA-5300 Series

THC-2, THC-3, THCR-4, THCR-5. Enthalpy Control. General Instructions APPLICATION SPECIFICATIONS. ACCESSORIES None

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

TS Series TS Series

Utility Distribution Systems Installation, Operation, and Maintenance Manual

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

Installation Instructions

BITZER Capacity Controller for CSH Compressors Temperature Sensor

Safety, Installation and Service Manual Models 1952, 1953 & 1972

Operation and Installation Manual

STARTER SYSTEM TESTING 5.6

Installation Instructions

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

30A SMART ENERGY MANAGEMENT SYSTEM TM

Model LA 4100 Time Delay OFF Controller

Notdson MANUAL REFILL/MELTER RETROFIT KIT. SUPERSEDES -i I/ f3 NORDSON CORPORATION 1984 All Rights Reserved

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

SPO15, SPO18 I N S T A L L A T I O N I N S T R U C T I O N S

AD592/592-10K Non-Room Units with a Junction Box, Weatherproof (WP) or Weather Tight (EU) Enclosure

MATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation

SECTION PANELBOARDS

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

INSTALLATION INSTRUCTIONS CRL JACKSON 2085E

Quick Connection Panel (QCP) Installation Guide

2520- EC Motor Speed Controller

FSAF24(-S) US, FSAF120(-S) US

IMPORTANT INSTRUCTIONS INSTALLATION AND STARTUP MODEL GDCP-A CONTROL PANEL

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Installation Instructions Capacity 10,000 lbs. (100 Series Lift)

CSA CERTIFIED Conforms to UL 507

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

BULLETIN NO.ELEC IM240/11A Supersedes IM240/10A

Transformer Installation, Operation, and Maintenance Manual

Operations and Service Manual. X30208 Load Bank

Hinged Safety Door Switch

Precision Power Center INSTALLATION, OPERATION, & MAINTENANCE MANUAL

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

Inde-Pendants Family. 32L Cylinder with Ring Chicago Plenum Ceiling Types. Document No

Materials. Contact Ratings. Conduit Entrances

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

Electric Range installation manual

Model LA 4400 Time Delay OFF Controller

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable.

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Model LA 4300 Time Delay OFF Controller

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

Cam-Lok Single Pole Connectors

Transcription:

ELECTRICAL INSTALLATION PROCEDURES For Custom Grid Assemblies & Power Generators BECAUSE CLEAN AIR MATTERS Note: Factory trained or suitably qualified personnel must perform this installation. General: Figure 1 shows the general recommended arrangement of the Power Generator, Input Power and Safety Door Switch in relation to the grid assembly within the plenum. The solid state power generator produces a high-voltage (HV) direct current, which is carried to the smaller HV grid by the red wire. The generator also produces a high-frequency (HF) alternating current, which is carried to the HF screen grid by the black wire. The power generator is supplied with a red 9 (2.8m) output cable with a potted male plug. Ring terminals, supplied loose, are used for field installation for the interconnection of output power to the grids. Also provided is a black HF and green ground cable of similar length. The electrical contractor must provide input power wiring and conduit. HV Grid Figure: 1 typical installation Mounting the Power Generator: As shown in Figure: 1, 2 & 6, the power generator must be mounted as close to the grids as possible. (No further away than 9 (2.8m) wire length.) Note: Mounting the power generator more than 9 (2.8m) from the grids voids the warranty. If mounting within 9 (2.8m) of the grids creates an observation problem, an optional Remote Indicator Lamp Unit is available for observation at a suitable location. In those instances where the customer has a building management system, CosaTron can also provide an optional system that provides dry contacts, which will interface with it.

The power generator can be mounted on the exterior or interior plenum wall using the cabinet mounting flanges loc ted at the top and bottom of the generator enclosure. To ensure proper air circulation through the power generator louvers, a minimum 6 (15.2 cm) clearance must be maintained at the top and bottom, a 3 (7.6 cm) clearance on each side of the power generator to assure proper air fl w for cooling between solid objects or another generator. (On air units exposed to weather conditions outside of the building, the power generator must be mounted in a weatherproof, waterproof enclosure or mounted in the air stream in the air handler before the cooling coils, call CosaTron for an optional enclosure or high hat type enclosure when necessary.) The power generatort is factory set to operate on 110/120 VAC 50/60 Hz single phase, 2 amp, 3 wire input power. Input power should be brought through metal conduit to an existing knockout on the input power compartment of the generator enclosure. It must also be wired through the safety door switch(es) (see CRS-SDSA). Connection is made to the power generator by removing the cover plate labeled Connect Input Power Here, then wire input power leads to power generator leads with wire nuts (See Figure 6, 6B). Caution: This equipment must be electrically (earthed) grounded. Wiring the Power Generator to the Custom Grid Assemblies: A cable kit (2 ¼-20 X 5/8 carriage bolts, 2 ¼-20 washer nuts, 4 lock washers, 2 ring connectors, 1 #10 fork connector, 1 red heatshrink tube and 1 black heatshrink tube) is supplied for interconnection of output power of the power generator, to the grid assembly. Figure: 2

The power generator is equipped with a knockout and a conduit clamp on the top of the power generator for interconnection of output power to the grid assemblies through metal conduit supplied by the installing contractor. Caution: The plenum assembly should be electrically (earthed) grounded. Run metal conduit no closer than 3 (7.6 cm) from the HV grid assembly. The conduit should be burr free so that the cables are not nicked as it is pulled. Feed the three (red, black and green) wires through the conduit to the inside of the plenum. Lead wires should be cut to a length which provides sufficient service loop allowance for partial removal of the grid(s) for servicingapproximately 12-18 (30.5 cm to 45.7 cm) longer than that required to reach grid(s). Excessive lead length or coiled wire may cause stray induction and adversely effect generator output. (See Figure 2 for illustration.) After cutting wires to the desired length, strip approximately ½ (1.3 cm) of insulation off the wire. Slide the ¼ (.6 cm) dia X 1¼ (3.2 cm) heatshrink tubing (provided) over the wire. Carefully and fi mly crimp the ring connectors (provided) on to the HV (red) and HF (black) wire. Carefully crimp the # 10 fork connector on the ground (green) wire. Caution: Make certain a proper mechanical as well as an electrical connection is established. Slide heatshrink tubing over crimped portion of ring connectors. Heat with a lighter, match or candle being careful not to burn insulation. Inside the plenum, connect the red HV wire to the HV braid or screen (small) grid, the black HF wire to the HF screen (large) grid and the green ground wire to the grid support framing (See Figure 2 and PUB2035). Note: Do not splice either the black HF or the red HV cable, as this will void the warranty. Caution: If the air entering the grids is above 85% relative humidity, non-hardening silicone grease should be applied to the connections to prevent corrosion. Install 2-gig ohm bleed resistor kit(s) (See Figure 2 & 6). Connect ¼ ring connector to the HV (smaller) grid with ¼-20 carriage bolt, lock washer and lock nut provided in the kit. Mount 2-gig ohm bleed resistor and grounding wire, as shown in Detail 2A of Figure 2 & Detail 6A of Figure 6, with self-drilling screws provided.

The electrical connection between grids, sideto-side and top-to-bottom, are made using the prepunched holes located 4 (10.2 cm) from the corner of the grid frames. Using the ¼-20 carriage bolts, lock nuts, and washers provided, attach as follows: Side-to-side: Aluminum electrical/mechanical connecting bars are provided for connecting adjacent grids side-to-side. Two sizes are included; the shorter bar provides electrical/mechanical connection between adjacent HF (large) screen grids at the pre-punched holes. The longer bar provides electrical/ mechanical connection between the adjacent HV braid (smaller) grids and is attached as shown in Figure 3. Top-to-bottom: For gridassemblies two or more high-connect the HV (small) braid grids with the red HV jumper wire. At the same time, connect the HF (larger) screen grids with the black HF jumper wire as shown in Figure 4. CAUTION: More than one generator will be supplied for plenums when cross section area exceeds the power generator capacity. Special instructions related to wiring will be provided with the submittal drawings and the shipping documents.

Mounting the Safety Door Switch: The safety door switch is an essential part of CosaTron it is designed for the safe operation of the system. One Safety Door switch is located inside each plenum access door (See Figure 5) and is wired into the line voltage circuit, using #14 or larger wire, to interrupt input power to the power generator when access doors are opened. Safety Door Switch 9/32" (7.1mm) X 3/4" (19mm) Slot typical 4 places Mounting Bracket Note 3/8" (9.5mm) holes provided for mounting switch from either end. Access Door Note: Any other plenum access within the immediate vicinity of the gridsmust be similarly equipped. A minimum 3 (7.6 cm) clearance must be maintained between the smaller HV grid and 1 (2.5 cm) from the larger HF gridand the safety door switch housing. This will help prevent any malfunction of the CosaTron system. In the USA, the switch must be an enclosed, carry-off, snap-action type, SPST, No., with minimum 2.0 amps per generator, 125-vac rating UL approved. The special support bracket provided is designed so that the switch can only PUB2020 Top of Plenum Figure:5 be activated by the properly positioned, special plunger, provided as part of the safety door switch assembly. See Safety Door Switch Data sheet (CRSSDSA) for additional information. Note: Do Not use normally closed (N/C) on safety door switch. Black Wire from Line Voltage Circuit to Normally Open Black Wire from Common to Input Power of Generator Side of Plenum access door Access Door Note: When plenum cross section area exceeds the power generator capacity, more than one power generator is required. When CosaTron systems are installed in separate plenums, one generator is required for each plenum. When more than one generator is required per gridassembly, refer to the CosaTronmultiple system-wiring diagrams in the submittal package and shipping papers for grid jumper locations and generator wiring. Note: The 2-gig ohm resistor provides a means for the capacitance voltage on the HV, braid gridto dissipate once power to the generator is removed. Generator power is typically removed when the plenum door is opened and plenum safety door switch opens or the power is turned off at the generator. The resistor should be mounted on the plenum floor or wall, not the grids. Three #8 X ¾ hex head self-drilling sheetmetal screws are supplied, 2 for mounting the 2-gig ohm resistor (See Figure 2, 2A and Figure 6, 6A) and one for attaching to a grounded surface. Note: Connect the 2-gig ohm bleed resistor to the HV grid that the power generator is connected to. NC NO COM

Figure: 6 For more information www.cosatron.com/start-up/ CosaTron 40 Odell School Rd, Suite 1 Concord, NC 28027 704.785.8145 t sales@cosatron.com IOM.elecrical.4 Updated 08/2014 Made in the USA