XELLEX BATTERY (HK) LIMITED SHENZHEN XELLEX BATTERY & POWER SUPPLY TECH. CO., LTD R03P-AAA UM4 TECHNICAL SPECIFICATIONS DRAFTED BY: CHECKED BY: APPROVED BY: CLIENT ADMITED SIGN SHENZHEN XELLEX BATTERY & POWER SUPPLY TECH. CO., LTD 6/F, Jiayu Bldg, Dong er Xiang 15#, Gongyuan Road, 22 Industry Zone, Bao an District, Shenzhen, PRC. TEL: 0086-755-27664401 27664402 27664403 FAX: 0086-755-27806777 27664407 Website: www.xellex-battery.com Email: sales@xellex-battery com HONGKONG XELLEX BATTERY CO., LTD Flat A, 12/F., Wing Sing Commercial Centre, 12-16 Wing Lok Street, Hong Kong TEL: 00852-28507117 FAX: 00852-25819986 Website: xellex.en.alibaba.com Email: xellex@xellex-battery.com The Technical Specifications hereinafter is only applicable to the Hg & Cd Free Zinc Manganese Dioxide R03P AAA type battery, which was provided by Xellex Battery Co., Ltd. All the practical technical data, which were used to describe Battery Performance involved in the Specifications are obtained from the relevant experiments to the products of Xellex. Rights reserved to take relevant rectifications or modifications to the structure and performance of the products without prior notice.
1.Scope The Specifications is solely applicable to the Xellex Hg & Cd Free Zinc Manganese Dioxide Battery---R03P 1.1Designations Xellex R03P IEC :R03P JIS :SUM-4 ANSI :24D Other AAA, 1212 1.2 Reference Document IEC 86-1 1996-07 --- Primary Batteries - General IEC 60086-2 1997-07 --- Primary Batteries Specification Sheets 2.Chemical System Zinc-Manganese Dioxide Battery (Zinc Chloridize Electrolyte, 0%Hg and 0%Cd added) 3.Dimensions Diameter: 9.5 10.5 mm 4.Nominal Voltage 1.5 Volts 5.Average Weight 7.6 g Height: 43.3 44.5 mm 6.Nominal Capacity 425mAh (75Ω continuous discharge Temp. 20 2 CDV<Cut-off Discharge Volt> 0.9 Volts) 7.Electrical Performance Conditions 75Ω 0.5% load resistance, Measuring time 0.3 Seconds, Temperature at 20 2, Tested within 30 Days after delivery Off-load Voltage V On-load Voltage V *Flush Short Circuit Current A Acceptance Standard New Battery 1.55 1.35 3.5 After 12 Mths Shelf Time at room Temp 1.52 1.30 3.0 MIL-STD105E,Class II Double Sampling AQL=0.4 *The Hair Spring Ampere Meter with 0.5% Accuracy (0.5 Level) shall be used. 8.Service Output Conditions Test Temp.20 2 Test within 30 Days after delivery
Test Standards IEC Standard Discharge Condition Discharge Daily Discharge Load Time Average Minimum Discharge Time Cut-off After 12 Mths Discharge New Battery Voltage V Shelf Time at room Temp. 75Ω 4 Hours 0.9 24.5 Hours 22 Hours 5.1Ω 4 Mins/Hour, 8 Hours 0.9 85 Mins 75 Mins 10Ω 1 Hour 0.9 150 Mins 135 Mins 3.6Ω 15 Secs/Mins 0.9 190 Times 170 Times Acceptance Criteria 9 batteries shall be tested for each discharging standard, the Average Discharging Time should be equal to or above the Average Minimum Discharging Time required. Moreover, the total amount of the batteries whose Average Discharging Time is less than 80% of the time required shall not exceed 1, Thus, the ADT of the batteries can be recognized accorded with the requirements 9.Electrolyte Leakage Proof Item Condition Period Temp. 20 2 15Ω continuous Over-charge Relative Humidity 65 discharge to 20%RH E.P.V.:0.6V Temp. 45 2 Storage Relative Humidity 90 Days 70%RH Characteristic s There shall be no deformation exceeding the specified dimensions, nor leakage recognized by human eye Acceptance Standard N=40,Ac=1,Re=2 N=40,Ac=1,Re=2 10.Safety
Item Condition Period Acceptance Standard Short Circuit Abusive Temp: 20 2 Relative Humidity: 60 15% Directly connect the Positive & Negative Terminals with a wire Temp.20 2 Connect 4pcs batteries in series in a battery case, in which, connect one of the batteries reversely, then short connect the wire of the battery pack, until the discharging ended up. There shall be no explosion of battery 24 Hours No explosion, No leakage, and no obvious deformation shall happen N=9,Ac=0,Re=1 N=12,Ac=0,Re=1 11.Marking The following markings will be printed, stamped or impressed on the body of the battery 1 Designation R03P AAA UM4 2 Manufacturer s name, abbreviation or brand XELLEX 3 Nominal Voltage 1.5 V 4 Polarity +, - 5 Warning: Battery may explode or leak if recharged or disposed of in fire. 6 Expiry Date(Guarantee Period) The Date which shows on the labels of the finished product is used to indicate the Quality Assurance Period before it is used. 7 Icon An Icon which indicates the battery can not be disposed of in the Rubbish Can. 12.Caution for Use 1 Since the battery is not manufactured for recharging, there are risks of electrolyte leakage or causing damage to the device if the battery is charged. 2 The battery shall be installed with its + and - in the right position. 3 Short-connecting, heating, disposing of into fire and disassembling the battery are prohibited. 13.Shelf Life 2 years after delivery under room Temp. or other proper storage conditions 14.Discharging Curves 75,24 Hours/Day, E.P.V: 0.9V Continuous Discharging Curves Figure 1 10,24 Hours/Day, E.P.V: 0.9V Continuous Discharging Curves Figure 2 3.9,24 Hours/Day, E.P.V: 0.9V Continuous Discharging Curves Figure 3
15.Battery Dimensions & Structure Figure 4 voltage(v) 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1 0.9 0.8 XELLEX R03P-P 75Ωcontiuous discharge curve--figure1 0 5 10 15 20 25 30 time(hrs) voltage(v) 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1 0.9 0.8 XELLEX R03P-P 10Ωcontinuous discharge curve--figure2 0 20 40 60 80 100 120 140 160 time(min) XELLEX R03P-P 3.9Ωcontinuous discharge--figure3 voltage(v) 1.8 1.6 1.4 1.2 1 0.8 0 5 10 15 20 25 30 35 40 45 time(hrs)
Spec. NO. XL R03P(PVC) AAA UM4 Edition Rev.00 Date 2005-08-28 Figure 4: