SFD-EN Smoke/Fire Dampers

Similar documents
Actionair Smoke/Shield PTC

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

SSV Smoke Shaft Ventilation System

HotShield PTC TM. High Operating Temperature Smoke Management and Fire Dampers. Features

NEW. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.

Catef Marine-Fire. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.

Catalogue. HotShieldPTC TM. High Operating Temperature Smoke Management and Fire Dampers.

Actionair Control and Shut Off Dampers

Blade Features. AirShield Control and Shut Off Dampers. AirShield

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers.

Specification. Introduction. A-60 Marine Fire Damper

A-60 Marine Fire Damper

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

FD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CONTROL SMOKE AND BALANCING DAMPERS

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Variable Air Volume Dampers

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Fan - Powered Terminal Unit Series Flow

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

7/S5 FIRE DAMPER FD40. v 2.9 (en)

Variable Air Volume (VAV) Pressure Independent Control

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Series HCD Airfoil Control Damper

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

Ceiling swirl diffusers

CADENZA. Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS

FSD-C Series. Circular Single Blade Externally Resettable Combination Fire and Smoke and Volume Control Damper PATENT APPLIED FOR V11804.

VARYCONTROL VAV Dual Duct Terminal Boxes

Fire Dampers Catalogue

FlowBar High Capacity Slot Diffuser

CONSTANTFLOW Volume Flow Controllers

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Introduction to Johnson Controls Dampers

Fire & Gas Dampers. Fire & Gas Dampers are used in ventilation systems to prevent the spread of flame and/or smoke between divisions.

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

Catalogue. FlowBar. High Capacity Slot Diffuser.

STR Circular VAV Terminal Units

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

MOTORIZED VOLUME DAMPER

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

DCV-RC DCV-RC. DCV-RC Room climate control unit. Room climate control SMART DAMPERS & MEASURING UNITS. Product description.

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Ceiling swirl diffusers

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

SINGLE DUCT TERMINAL UNITS

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Fire damper FK120/FK90 TECHNICAL DATA

CFSD Series. Product Description

Motorized Fire Dampers

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

M A D E L. FOK-EIS-180 Fire dampers CE

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

CAV controllers Type RN

VAV controller. TROX Auranor Norge AS. Telephone Fax

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

MegaBox Product-specific information

Master Plus kva

Fire/combustion gas damper EKO-JBL

VOLUME CONTROL / REGULATING DAMPERS

4.1 Functional diagram FM100 fume hood monitor... 4 Functional description FM Interfaces Terminal diagram FM100...

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

TYPE EK-EU SMOKE CONTROL DAMPER

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

ULTRA-ZONE FORCED AIR ZONE CONTROLS EWC

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Ceiling swirl diffusers with perforated face plate

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Fire/combustion gas damper EKO-JBG

Ceiling swirl diffusers

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION

Parts and characteristics

series FSD-FLD Fire and smoke dampers UL Approval

Acoustic Twin Fans (ATQ)

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Transcription:

December 2009 SFD-EN SFD-EN Smoke/Fire Dampers Features Proportional Torque Control for optimised torque performance. Unique snaplock drive interface ensures user friendly connection of Control Actuator to Damper. Tested and approved to BS ISO 10294-1:1996, BS EN 1366-2:1999 and BS476 pt. 20:1987 Fire Test Standards. SFD-EN is an LPCB approved product and conforms to the requirements of LPS1162 iss 2. Easy connection to square, rectangular, circular and flat oval ductwork. Unique and patented Electrical Thermal Release for ultimate safety. Halogen Free Low Smoke and Fume cabling supplied as a standard safety feature. Safegard V3 Damper Control System compatibility with BFS 9999. SFD-EN Fail-Safe Open reverse action dampers for smoke release or exhaust applications. Belimo Based Fire Series Actuator. Control Options: IP66, ATEX and Pneumatic.

Application Parameters SFD-EN and SFD-EN Fail-Safe Open dampers to maximum width and height dimensions (see pages 8 and 9) can be used where the operating total system pressure is up to 10 Pascals and duct velocities to 15m/second. The SFD-EN Fail-Safe Open damper blades are powered closed and fail-safe to the open position for smoke release or exhaust. Dampers may be installed both vertically and horizontally. In addition, for vertical installations, the damper may be installed with the blades running vertically. Airflow can be from either direction. Safegard SFD-EN and SFD-EN Fail-Safe Open dampers are designed for applications in normal dry filtered air systems. If exposed to fresh air intakes and/or inclement conditions, the dampers should be subject to a planned inspection programme. SFD-EN Hot Actuators available, 300 C for 1 hour applications. Please discuss with Safegard Customer Service. Introduction Safegard s engineering team has always been at the forefront in the innovative development, design and manufacture of life safety dampers and associated controls. Now with the unique SFD-EN range of Automatic Smoke and Fire Dampers Safegard continues this tradition. The Range The SFD-EN range of Quality Engineered Dampers are suitable for air conditioning and ventilation systems requiring up to 2 hours (vertical) and 4 hours (horizontal) smoke and fire protection. These aerodynamic stainless steel interlocking opposed blade dampers are fail-safe spring closed with electrical reset control actuator. SFD-EN Fail Safe Open dampers are reverse acting for smoke release or exhaust. The control actuator and snaplock drive interface provides the optimum torque advantage to the damper. Specification SFD-EN Automatic Smoke and Fire Dampers with 75mm stainless steel aerodynamic interlocking blades incorporating synthetic seal, with steel blade end bearings and peripheral gasketting. Housed in a galvanised steel fully welded 1.2mm spigotted casing suitable for square, rectangular, circular or flat oval connections. All SFD-EN Dampers are supplied with the blades in the closed position to prevent the ingress of dirt an dust. The totally enclosed precise movement opposed blade drive shall be positioned out of airstream for protection against damage, be hard wearing and free running. The Actuator/Damper connection shall be by means of the snaplock drive interface mechanism, which is totally independent of the ductwork. SFD-EN Automatic Smoke and Fire Dampers with their appropriate control actuators shall have spring Fail-Safe Closed or open operation as required. SFD-EN Damper and selected Control Actuator 24V / 230V as supplied by Safegard. SFD-EN A Fire Rated Damper in accordance with British Standard 5588: Part 9999: 1999 should be held in the Open Position by means of a Thermally Actuated Device set to operate at approximately 74 C. SFD-EN Automatic Smoke and Fire Control Dampers are Fire Rated Dampers as they are held in the Reset (Open) Position by a triggered actuator. Control Actuators 24V or 230V Electrical Thermal Release operating at a temperature of approximately 72 C ± 4 C. 2 www.safegard.ie

Casing Features Spigotted galvanised 1.2mm thick steel (to BS EN 10327) casing. SFD-EN comply to Class A and B of Eurovent Document 2/2 and Test Procedures for Classes A, B and C of HVCA Ductwork Specification DW145. Damper casings are manufactured with fully welded spigotted connections suitable for Square, Rectangular, Circular and Flat Oval duct connections. As an extra cost option, casings can be manufactured in 430 grade (Type 1.4016) Ferritic or 316 grade (Type 1.4401) Austenitic stainless steel, 1.2mm thick. Square / Rectangular SPG Circular SPG Flat Oval Blade Features SFD-EN damper blades are aerodynamic, Type 1.4016 (430) Ferritic stainless steel, which are 75mm wide and interlock to form a positive smoke and fire resisting shield. Multiple Assemblies Square and rectangular casings are available in multiple module arrangements supplied complete with joining channels for site fixing by others. LHD STD RHD PLAN VIEW STD RHD LHD Incorporated within the blade profile is a synthetic seal to ensure low closed blade smoke leakage. STD RHD LHD Stainless steel blade end bearing and peripheral gasketting maintain the low closed blade smoke leakage whilst allowing for expansion under full fire conditions. STD RHD LHD Optional Blade construction Type 1.4401 (316) Austenitic stainless steel. www.safegard.ie 3

Damper Control Actuator Interface (Actuator 24V / 230V shown) snaplock Drive Interface Designed to develop Proportional Torque Control Control Actuator 24V/230V shown SFD-EN Damper with unique snaplock Damper/Control Actuator Interface Automatic Smoke and Fire Damper and Control Actuator assembly with a unique and dedicated Proportional Torque Control for optimised Damper/Control Actuator torque performance. The unique snaplock drive interface ensures user friendly, easy and secure connection of the Control Actuator to the Damper. The drive interface which is totally independent of the ductwork, eliminates the need for costly dedicated duct sections, and provides ease of connection to square, rectangular, circular and flat oval ductwork. SFD-EN Square Damper sdamper Drive Shroud and Transit Plate 3 Position Location Plate Control Options A choice of Control Actuators are located outside of the ductwork for easy access and installation. All SFD-EN Control Actuators must be in the released position prior to connection. Control Actuators 24V or 230V Optimised motor/spring return control actuators with remote reset-release facilities, with volt free contacts for provision of external indication, monitoring and control by means of an Safegard damper control system, or by a suitable alternative proprietary control format. The motorised Control Actuators 24V and 230V can be fitted in 3 positions through 180 (see page 7) allowing maximum onsite installation flexibility. (Position 2 is supplied as standard). Electrical Thermal Release (ETR) (SFD-EN Only) Actuator 24V / 230V can be fail-safed by means of a unique and patented Electrical Thermal Release (ETR) which operates at approx 72 C or if power supply is interrupted, complying with BS 9999 : 2008 (Ref 33.4.5.3). The ETR incorporates triple safety features, including an ingenious device that ensures the fail-safe status of the damper if the ETR is not fitted on to the ductwork. A manual test switch allows periodic operation of the damper for testing purposes simulating actual fail-safe release under smoke/fire conditions. For safety reasons the ETR is designed to operate once only when the activation temperature is reached. ETR Indication light As standard, a green LED lamp is built into the ETR housing. This gives the user a simple and clear visual check that the Actuator is receiving power, the ETR is correctly fitted, and the thermal fuse is intact. 4 www.safegard.ie

Application and Wiring - Actuator with ETR SFD-EN 24V The following applies for ETR version. (ETR not supplied on SFD-EN Fail Safe Open). Supply On Damper motors reset. Supply Off Spring release. Electrical Thermal Release. External mechanical position indicator with pointer. Release Time 22 secs. Reset Time 60 secs. (Connect 24V via a safety isolating transformer.) IP54 Rated. AC/DC 24V / 60 Hz 12.5 VA 10 / 2 W Imax 8.3A @ 5ms 30...+ C CONTINUOUS AC 2V 6(3)A M BLACK WHITE TF 72 C 1 2 1 2 3 4 5 6 + SUPPLY 24V AC or DC TYPICALLY 10W (MOTORING) 2W (RESET) VOLT FREE CONTACT MADE BETWEEN 1 AND 2 WHEN DAMPER FULLY RELEASED VOLT FREE CONTACT MADE BETWEEN 4 AND 6 WHEN DAMPER FULLY RESET ELECTRICAL THERMAL RELEASE (MUST BE FITTED TO DUCTING FOR DAMPER OPERATION). NON ETR VERSION AVAILABLE ON REQUEST (SPRING BIASED TEST SWITCH) DIAGRAM SHOWS ACTUATOR IN FULLY RELEASED STATE SFD-EN 230V The following applies for ETR version. (ETR not supplied on SFD-EN Fail Safe Open). Supply On Damper motors reset. Supply Off Spring release. Electrical Thermal Release. External mechanical position indicator with pointer. Release Time 22 secs. Reset Time 60 secs. (To isolate from main power supply, the system must incorporate a device which disconnects the phase conductors, with a least 3mm contact gap.) IP54 Rated. AC 230V / 60 Hz 14 VA 12 / 4 W 30...+ C CONTINUOUS AC 2V 6(3)A M BLUE BROWN TF 72 C N L1 1 2 3 4 5 6 SUPPLY 230V AC /60 Hz TYPICALLY12W (MOTORING) 4W (RESET VOLT FREE CONTACT MADE BETWEEN 1 AND 2 WHEN DAMPER FULLY RELEASED VOLT FREE CONTACT MADE BETWEEN 4 AND 6 WHEN DAMPER FULLY RESET ELECTRICAL THERMAL RELEASE (MUST BE FITTED FITTED TO DUCTING FOR DAMPER OPERATION). NON ETR VERSION AVAILABLE ON REQUEST (SPRING BIASED TEST SWITCH) DIAGRAM SHOWS ACTUATOR IN FULLY RELEASED STATE Actuator Cable The Actuator is supplied with one metre of halogen free low smoke and fume electric cable for convenience of on site wiring. This also provides the distinct safety advantage of all electrics terminating outside the duct, eliminating potential induct fire hazards from wiring faults. www.safegard.ie 5

Installation Systems Dry Wall / Stud Partition Popular types of Installation Systems that are available. 1. Dry Wall /Stud Partition 2. Block Wall / Concrete Wall and Floors Dry Wall Installation/After Wall Built Dry Wall Installation/Before Wall Built Dry Wall Installation/After Wall Built Dimensional Data See pages 8 and 9. Dry Wall Installation/Before Wall Built Dimensional Data Specification The Safegard Dry Wall Installation/After Wall Built method is BRE Tested to EN1366-2, BRE test report 6493. Classification E120/ES120 BS EN 131. Specification The Safegard Dry Wall Installation/Before Wall Built method is BRE Tested to EN1366-2, BRE Test Report 231741. Classification E120/ES120 BS EN 131. 24 14 This method consists of a 1.2 mm galvanised steel peripheral flange with mm x mm x 3mm steel angle cleats with 14 x 24mm oval slots, welded to damper flange for drop rod support. This method consists of mm x mm x 3mm steel angle cleats with 14 x 24mm oval slots, welded to damper casing for drop rod support prior to wall construction. Installation Systems Block Wall / Concrete Wall and Floors HEVAC / HVCA Galvanised Steel Installation Frames (I/F) Galvanised steel building ties permit stable handling, ease of transport and convenience of building in to the surrounding structure. 6 www.safegard.ie

Control Actuator Dimensions and Orientation 56 84 260 Actuators 24V and 230V Three position 180 (Pivotable Control Actuator) SFD-EN Control Actuators are located outside of the ductwork for ease of access and installation. 108 Position 3 Position 2 The Control Actuators can be fitted in any one of three orientations i.e. Vertically down (Position 1) Horizontally (Position 2), or Vertically up (Position 3). Position 1 248 This can be simply and easily carried out on site, by repositioning the Location Plate and Control Actuator on to the snaplock Drive Interface. 56 12 100 This flexibility ensures that the damper and control actuator require the minimal amount of room. (Supplied in position 2 as standard.) Approximate Weights (Kg) Square or Circular 100 1 200 2 300 3 400 4 0 5 600 6 700 7 800 8 0 9 1000 Duct Size (mm) Series 1 Square 3.4 3.4 3.4 4.2 4.8 5.6 6.5 7.4 8.6 9.6 10.8 12.4 13.6 14.9 16.2 17.7 19.2 20.8 23.5 Series 1 Square + I/F 6.2 6.2 6.2 7.4 8.7 10.3 11.9 13.2 14.6 16.3 18.5 20.5 22.1 24.0.9.1 30.3 32.4 34.5 Series 601 Circular 5.3 5.3 5.3 6.1 7.2 8.4 9.6 11.2 12.6 14.0 15.9 17.5 19.1 20.7 22.5 24.3 26.2 29.3 32.1 Series 601 Circular + I/F 8.5 8.5 8.5 10.0 11.9 13.7 15.4 17.1 19.2 21.8 24.0 26.0.2 30.4 32.8 35.3 37.8 40.3 43.1 Control Actuators 24V and 230V (including drive interface) 4.4Kg www.safegard.ie 7

Dimensional Data For Rectangular Dampers spigots are 5mm under duct size. * Widths and heights available in 1mm increments. Basic Dampers Rectangular Dampers For Ducts with widths of 100 1mm* For Ducts with heights of 100 1mm* Dampers with Installation Systems Dampers with Dry Wall Fixing (After Wall Built) OVERALL FLANGE WIDTH = 370mm OVERALL FLANGE HEIGHT = 395mm (For further details please refer to Safegard Customer Service.) HEVAC / HVCA (I/F) OVERALL WIDTH OF INSTALLATION FRAME IS 316mm OVERALL HEIGHT OF INSTALLATION FRAME IS 340mm = 100-1 = DUCT WIDTH DUCT HEIGHT 83 = 151-199 = 200-1000 200-1000 200 For Ducts with widths of 151 199mm* 110 DUCT WIDTH 2 DUCT WIDTH DUCT HEIGHT 100-1 DUCT HEIGHT 151-199 For Ducts with widths and heights of 200 1000mm* DUCT HEIGHT 200-1000 38 38 78 38 38 78 38 38 38 38 200-1000 2 200 For Ducts with heights of 151 199mm* 38 78 38 OVERALL FLANGE WIDTH = 420mm OVERALL FLANGE HEIGHT = 445mm 85 200 110 2 85 OVERALL FLANGE WIDTH = DUCT WIDTH + 170mm OVERALL FLANGE HEIGHT = DUCT HEIGHT + 195mm 110 200-1000 85 200 57 OVERALL WIDTH OF INSTALLATION FRAME IS 366mm OVERALL HEIGHT OF INSTALLATION FRAME IS 3MM 83 57 2 OVERALL WIDTH OF INSTALLATION FRAME IS DUCT WIDTH + 116mm OVERALL HEIGHT OF INSTALLATION FRAME IS DUCT HEIGHT + 140MM 83 57 200-1000 8 www.safegard.ie

For Circular and Flat Oval Dampers spigots are 3mm under duct size. *Diameters and flat oval diameters in 1mm increments. Basic Dampers Circular Dampers 1mm Increments ** = DUCT DIA 100-1* = Dampers with Installation Systems Dampers with Dry Wall Fixing (After Wall Built) OVERALL FLANGE WIDTH = 370mm OVERALL FLANGE HEIGHT = 395MM HEVAC / HVCA (I/F) OVERALL WIDTH OF INSTALLATION FRAME IS 316mm OVERALL HEIGHT OF INSTALLATION FRAME IS 340mm DUCT DIAMETER = 100-1* 108 200 CIRCULAR ** CIRCULAR = 200 65 38 78 38 65 85 82 1mm Increments ** DUCT DIA 151-199* = = OVERALL FLANGE WIDTH = 420mm OVERALL FLANGE HEIGHT = 445mm OVERALL WIDTH OF INSTALLATION FRAME IS 366mm OVERALL HEIGHT OF INSTALLATION FRAME IS 3mm DUCT = DIAMETER = 151-199* 2 2 CIRCULAR ** CIRCULAR 110 85 108 82 65 38 78 38 65 1mm Increments ** DUCT DIA 200-9* OVERALL FLANGE WIDTH = DUCT DIA. + 220mm OVERALL FLANGE HEIGHT = DUCT DIA. + 245mm OVERALL WIDTH OF INSTALLATION FRAME IS DUCT DIA + 166mm OVERALL HEIGHT OF INSTALLATION FRAME IS DUCT DIA + 1mm DUCT DIAMETER 75 110 108 110 200-9* Duct Duct DIA + mm* CIRCULAR ** CIRCULAR 85 82 FOR 951 1000mm DUCT DIM + 30mm 65 38 78 38 65 Flat Oval Dampers 1mm Increments ** DUCT WIDTH * 300 9* 75 OVERALL FLANGE WIDTH = DUCT WIIDTH + 220mm OVERALL FLANGE HEIGHT = DUCT HEIGHT + 245mm 110 OVERALL WIDTH OF INSTALLATION FRAME IS DUCT WIDTH + 166mm OVERALL HEIGHT OF INSTALLATION FRAME IS DUCT HEIGHT +1mm 108 DUCT HEIGHT 200-0* DUCT WIDTH + mm* DUCT HEIGHT +MM FLAT OVAL ** 65 38 78 38 65 FLAT OVAL 85 82 FOR 951 1000mm DUCT DIM + 30mm * www.safegard.ie 9

Acoustic Data The data presented is from the Laboratory Determination of Acoustic and Aerodynamic Performance of SFD-EN Automatic Smoke and Fire Control Dampers. Pressure Drop Vs Velocity Graph 1 A programme of extensive tests was carried out in the Reverberation Chamber and North Transmission Chamber of Sound research Laboratories Limited, Holbrook Hall, Sudbury, Suffolk, generally in accordance with BRITISH STANDARDS Nos. 4196, 4773, 4856, 4857 and 4954. 100 80 70 60 This independent test facility is approved under the NAMAS Scheme. 40 From the selection of a duct velocity within the operational parameters of the damper a resultant pressure drop from Graph 1 can be determined and the sum of these two components applied to the Velocity x Pressure Drop Vs Sound Power Level Graph. (Graph 2) The graph is the result of a full range of acoustic tests on SFD-EN Automatic Smoke and Fire Control Dampers with the blades set in their fully open position. The Spectrum Correction Data is applied to the number obtained from the graph and a complete Sound Spectrum of Flow Generated Noise for both Outlet (in duct) and Breakout (casing radiated) can be obtained from Table 1. PRESSURE DROP (Pa) 30 20 10 9 8 7 6 5 4 3 EXAMPLE LINE RECTANGULAR CIRCULAR 2 1 1 2 3 4 5 6 7 8 9 10 15 VELOCITY (m/s) Example: Duct with a design velocity of 8 m/sec. SFD-EN Damper Series 1 fully open. Pressure Drop = 21 Pa (Graph 1). Multiply Velocity x Pressure Drop 8 x 21 = 168. From Sound Power Graph (Graph 2) plot 168 on horizontal Velocity/Pressure axis against 1 outlet (induct) graph to obtain 47 dbw on Vertical Sound Power Level Axis. Add or subtract corrections to the 47 dbw to provide full spectrum analysis using appropriate Correction Table. 10 www.safegard.ie

Velocity (m/s) X Pressure Drop (Pa) Vs Sound Power Level (dbw) Graph 2 80 Damper Leakage Graph 3 SFD-EN closed blade leakage as tested on a damper 1000mm wide x 1000mm high. Leakage data at Ambient temperature (Cold Smoke). 10 SOUND POWER LEVEL (dbw) 70 60 40 30 20 10 0 10 EXAMPLE LINE 20 30 RECTANGULAR BREAKOUT 40 60 70 80 100 CIRCULAR BREAKOUT 200 300 CIRCULAR OUTLET (INDUCT) RECTANGULAR OUTLET (INDUCT) 400 0 600 700 800 0 1000 2000 3000 4000 00 6000 7000 8000 00 10000 PRESSURE DIFFERENTIAL ACROSS CLOSED DAMPER (Pa) 1200 1000 0 300 2 200 1 120 100 VELOCITY X PRESSURE DROP (m/s Pa) 70 Correction Tables Table 1 SFD-EN Outlet (Induct) Spectrum Corrections Octave Band Hz 63 1 2 0 1k 2k 4k 8k Rectangular db 5 4 5 5 3 1-3 -5 Circular db 9 4 4 5 3 1-3 -6 Table 2 SFD-EN Breakout Spectrum Corrections Octave Band Hz 63 1 2 0 1k 2k 4k 8k Rectangular db 8 11 9 6-3 -6-14 -17 Circular db 6 10 8 4-3 -3-11 -14 5 10 20 30 40 100 LEAKAGE (I/s) The SFD-EN Damper has been fire tested to BS ISO 10294-1 and BS EN 1366-2. It achieved ES classification in accordance with BS ISO 10294-2:1999. ES classification allows a maximum of 200m 3 / Hr/m 2 (corrected to 20 C) hot gas leakage throughout the test at 300 Pa pressure differential across the damper. www.safegard.ie 11

Safegard Damper Control Systems Safegard SCMP - Bespoke Control and Monitoring System Control Panel The SCMP Control Panels typically consists of the appropriate number of switches to provide individual or group control, LED indication for status monitoring and all necessary relays and timers to comply with the customer needs for fully or semi automatic damper operation. The SCMP panels are purposely manufactured for any particular project to suit specific client requirements. Safegard V3 Intelligent Damper Control and Monitoring System The Safegard V3 system represents a new generation of smoke/fire damper control. The system has been designed with the user in mind, providing an advanced tool that simplifies installation and commissioning of smoke/fire dampers and peripheral devices. The Panel PC operates on a Windows platform making it universally accepted and utilises solid state technology for optimum reliability. It s server architecture delivers new benefits such as reduced commissioning time, simplified operation and scope for future growth. The Safegard V3 system is designed to protect life and property from damage caused by smoke and fire, by providing the means to: Compartmentalise fire zones. Reduce the spread of smoke and fire. Keep escape routes and fire-fighting access open. Allow pressurisation and smoke extract by combined operation of dampers and fans. Benefits Completely flexible to meet practically any building s damper requirements Three levels of alarm priority Panel PC driven system with real-time graphic displays Panel PC utilises solid state technology for optimum reliability Full configuration and diagnostics from Panel PC Optional automatic scheduled Damper testing Multiple wiring configurations to include Radial or Loop Topology Damper operational count provided Flexibility to accommodate any last minute changes to strategy, zones, damper quantities, references and descriptions etc. Powerful and flexible functionality enables standardisation of software (no bespoke site specific versions required) Cause and effect scenarios easily accommodated Multiple options for monitoring dampers, individually or by group or zone - output contacts can be triggered when a predefined percentage within a group or zone change position System designed to cater for environmental occupancy as well as the building s smoke/ fire strategy. RS232 BMS link provided enabling a BMS to link directly to the system to read damper positions etc. Optional remote access available Graphical User Interface displays live damper status and details as well as cause and effect strategies Text fields facilitate clear description of device references and locations System wide activity logged and viewable for diagnostics and maintenance Allows for phased commissioning and future expansion CE, LPCB marked, LVD and EMC compliant Open protocol 12 www.safegard.ie

General Schematic of Safegard V3 Damper Control System To additional devices as required To additional devices as required Smoke Fire Damper Interface One per Control Mode Damper Control Mode* NDI404 Network Digital Input / Output Device - provides four inputs and four outputs * Only one Damper to be controlled by an FDI, 3PFDI or HDI. Supply to each Damper Interface from nearest local distribution board. NDI404 Data Network Panel PC Vent Panel B.M.S. OUTPUTS INPUTS Fire Alarm Inputs BMS Inputs Fireman s Switch Inputs www.safegard.ie 13

Approvals Customer Service Approved by The Loss Prevention Council for use in up to 4 hour constructions. Refer to Installation and Maintenance Guide on our website for precise details. The SFD-EN PTC Damper tested and assessed to BS ISO 10294-1, BS EN 1366-2 and BS 476 pt. 20. It achieved ES classification in accordance with BS ISO 10294-2:1999. Low gas/smoke and fire integrity to Classification ES in vertical and horizontal test installations. An LPCB approved product, compliant to the new Loss Prevention Council Design Guide for Fire Protection of Buildings. Fire tested in vertical and horizontal applications under dynamic conditions by The Loss Prevention Council. Corrosion tested to LPS 1162. Complies with the latest DW 145 casing leakage specification. The Electrical Control Actuators satisfy the requirements of EN 081-1 and EN 082-1 electro magnetic compatibility. Safegard provides quality products backed by a dedicated team committed to providing the very best in customer service. Offering experienced technical backup, comprehensive sales and administrative customer support, product commissioning and maintenance service. The information contained herein is subject to change without notice due to continuing research and development. Unit 34, Southern Cross Business Park, Bray, Co.Wicklow T: +353 1 2761600 F: +353 1 2761611 Penthouse Floor, No 5 Lapps Quay, Co. Cork T: +353 21 4943989 F: +353 21 4943988 E: info@safegard.ie W: www.safegard.ie