MANUAL FOR INSTALLATION AND OPERATING

Similar documents
MANUAL FOR INSTALLATION AND OPERATING. for gearbox model ILG/D

MANUAL FOR INSTALLATION AND OPERATING. for gearbox model ILG/D

MANUAL FOR INSTALLATION AND OPERATING

Factor 2) 160:1 6) /(30) FA10 (FA14) :1 6) /(30) FA10 (FA14) 27 86

Factor 1) Modulating torque 4) [Nm] 200 F14 G1/2 GK : :

Reduction ratio. Factor 1)

Factor 1) Modulating torque 4) [Nm]

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Valve attachment Gearbox Reduction ratio :1 5) : ,

Factor 3) Max. input torques Flange 38 GS : F ,000 F10 F ,000 F12 82:

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

ILED Dorado. User Manual

GEARBOXES for operation of industrial valves

Operating instructions for worm gear boxes

Instructions for installation, operation and maintenance of: GATE VALVE

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Overview of types. Technical data

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

BUTTERFLY VALVE 17 SERIES Gearbox

INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL BC.

USERS MA UAL Bellow sealed valve Fig.229, 230, 234, 235 Edition: 1/2008

KEYSTONE Figure 990/991 Butterfly valves Installation, operation and maintenance instructions

ILG-D Series Cast Iron Housing Declutchable Gear Operators

GT-200 GATE VALVES PN16, Screwed end

PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions

IQL Helios Area-/Streetlight. User Manual

Rotork Gears Houston. Products and Facilities Rotork Gears, Houston USA. Keeping the World Flowing

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

ROM Series. Established Leaders in Flow Control. Installation Manual. Valve Actuators

Operation & Maintenance Manual

Part-turn gearboxes GS 50.3 GS 250.3

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No:

INDUSTRY PROCESS AND AUTOMATION SOLUTIONS. Technical Bulletin

AE Installation Operation & Maintenance Instructions

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

VALVES WITH NA ELECTRIC ACTUATOR

BUTTERFLY VALVE - WAFER FAF 3500

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

EW 350 ELECTRIC ACTUATOR INSTALLATION, MAINTENANCE AND OPERATION MANUAL

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Surepowr Series 100 Installation Manual

Installation and operating manual

Technical Data Part-turn gearbox 2SP78

KEYSTONE OPTISEAL F14/16-15/17 AND BREWSEAL BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Surepowr Series Sure 150

Dry installed pump type LANDY BTP.

HAZMAT PUMPS TUP, GUP, IN EX explosion proof up to 620 l/min, up to 2.0 bar

Series J Shaft Mounted Gearbox

ASR WORMWHEEL UNLOCK DEVICE. ASR - Worm Speed Reducers types RS and RT

EXECUTIONS DBBV S t a n d a r d e x e c u t i o n Part no. Description

Installation Instructions. Install Hubs Set Spacing Install Element FINISHED BORE INTERFERENCE FIT. Step 1 - HUB INSTALLATION

MO Declutchable Manual Override Gearbox EL-O-Matic F-Series Actuators option

Established Leaders in Valve Actuation CP RANGE COMPACT PNEUMATIC ACTUATORS INSTALLATION AND MAINTENANCE MANUAL. Publication F230E Date of issue 03/08

Lever gearboxes GF 50.3 GF 250.3

Materials : Ductile iron EN GJS body, EPDM seat

PNEUMATIC ACTUATORS ASSEMBLY & MAINTENANCE PROCEDURES. Ref. Doc. MMMACTREGDRE English Rev.2 January 2012 ADA & ASR SERIES DOUBLE ACTING ACTUATOR ADA

Level switches (two-term level controllers) ERH-xx-04,-06,-07,-16,-16.1 Description

Lenze. Drives with worm gearboxes 52.

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Materials : Carbon steel or stainless steel

SERIES 90/91 R PNEUMATIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Pneumatic actuator Assembly & maintenance procedures

INSTALLATION, OPERATION & MAINTENANCE MANUAL Description Handling Installation Actuators...

INSTALLATION, OPERATION AND MAINTENANCE MANUAL OF KNIFE GATE DURGA VALVES PVT. LTD. ICHAPUR ROAD, CANAL SIDE, SANTRAGACHI, HOWRAH

Materials : Carbon steel or stainless steel

26 Series Stainless Steel 2-way Ball Valves

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

MADE OF STAINLESS...

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

Installation and Operating Manual

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT

BIDIRECTIONAL WAFER Knife Gate Valve

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Instruction Manual. XDS Dry Pump A72X-YY-ZZZ

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual

Hermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO 2858 / DIN EN 22858

INSTRUCTIONS FOR USE SPUR GEAR OPERATORS. E. EBONG issue 4 SPUR

Product manual cable glands type IR and IB. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

SUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS

GBV-G Balancing Valves

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

series BUTTERFLY VALVE DOUBLE ECCENTRIC FLANGED FAF 3800 PRODUCTION STANDARDS DN100 DN2000 PN Design EN 593 EN ISO Flanged

70 Series 8700 End Mount Three Phase Brake Instructions IP56 (NEMA 4) Housing

Type 6213 EV, 6281 EV

Double Block and Bleed Dual Expanding Plug Valve

3 PIECES BALL VALVES ASSEMBLY & MAINTENANCE PROCEDURES

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

SELF PRIMING CHEMICAL SERVICE PUMPS

CONTROL VALVE TECHNICAL MANUAL MT100 INSTALLATION, COMMISSIONING AND MAINTENANCE INSTRUCTIONS. Issue December 2009

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

BUTTERFLY VALVE WAFER TYPE of carbon steel 311 ( ) series

UNIDIRECTIONAL Knife Gate Valve

Maintenance-free metal-seated globe valves. Grey cast iron PN 16 DN Nodular cast iron PN 16 DN Nodular cast iron PN 25 DN

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

Transcription:

MANUAL FOR INSTALLATION AND OPERATING for gearbox model AB, 232 and 300 2010-rev.01

1. Preface... 3 1.1 Technical data... 3 1.2 Handling and safety precautions... 4 1.3 ATEX... 4 2. Installation : mounting to the valve... 5 3. Adjustment of the setscrews... 6 4. Operating instructions... 7 5. Maintenance... 8 Rotork Gears bv 2

1. Preface The gearbox of the AB-, 232- and 300-series is a quarter turn gearbox intended to be used for the operation of valves (e.g. butterfly/ball valves) in pipelines. NB. This is valid only for the standard AB-, 232- and 300-series gearboxes of Rotork Gears BV. For special versions, specifications and model can differ. Rotork Gears BV is not responsible for any damage caused by incorrect use of the gearbox. 1.1 Technical data Specifications The maximum allowable input- and output torque are listed in. Gearbox Connection Valve Max. Torque [Nm] type ISO 5211/1 Input Output AB 150 F05-F07 16 150 AB 210/215 (LB) F05-F07-F10(-F12) 28.5/43 330/500 AB 550 (LB) F07-F10-F12-F14(-F16) 83 1000 AB 880 (LB) F10-F12-F14-F16 152 2000 AB 1250 (LB) F10-F12-F14-F16(-F25) 171 3250 AB 1950(LB) F12-F14-F16-F25(-F30) 289 5500 AB 1950(LB) HR F12-F14-F16-F25(-F30) 159 4500 AB 1950(LB)/SP4 F12-F14-F16-F25(-F30) 125 6800 AB 6800(LB) F16-F25-F30(-F35) 305 8400 AB 6800(LB)LT/SP4 F16-F25-F30(-F35) 96 9000 AB 6800(LB)/SP4 F16-F25-F30(-F35) 134 12500 AB 6800(LB)/SP6 F16-F25-F30(-F35) 121 17000 AB 6800(LB)/SP9 F16-F25-F30(-F35) 92 17000 A 200/SP9 F25-F30-F35 166 26000 A 250LT/SP9 F25-F30-F35-F40 116 26000 A 250/SP9 F25-F30-F35-F40 142 32000 232-05O F05-F07 13 125 232-05N F05-F07 12,5 125 232-06 F05-F07 25 250 232-07 F05-F07 21 250 232-08 F07-F10 41,7 500 232-10 F07-F10-F12 39 500 232-11 F10-F12 75 900 232-12 F10-F12-F14 100 1000 232-13 F10-F12-F14 83 1000 232-14 F10-F12-F14 125 1500 232-15 *per application 125 1500 307 F07 21 250 310 F10 39 500 312 F12 100 1000 table 1 : Connection data of the gearbox For more specified information, you can contact our sales department. Rotork Gears bv 3

1.2 Handling and safety precautions Be sure to read and understand this before installation and use of our gearboxes. Storage The gearboxes need to be stored in a safe way to avoid accidents. Also avoid storage in areas subjected to high temperature extremes and /or areas subjected to large amounts of humidity and dust. Handling Never drop the gearbox or otherwise subject it to strong impact. Correct use Prior to installation, be sure the gearbox will NOT be overloaded during normal use. For this, verify that valve size and required opening torque do not exceed the values given for the gearbox. For the maximum allowable torque on the gearbox, see table 1. Installation and operating Not observing the rules as stated in this, can lead to damage and / or personal injuries. The qualified personnel must be fully aware of the instructions as described in this. Only when the instructions are observed, correct operation of the gearboxes can be guaranteed. Disposal Never dispose a gearbox at a general disposal site/depot. The gearbox has to be offered to a disposal depot for recycling. The iron parts can be used for recycling. The seals are of nitrile and can be used for plastic recycling. The grease may not be discharged to sewer- or surface water. It has to be disposed according to local regulations for incineration. 1.3 ATEX Directive EC 94/9/EG states the directive only applies to equipment which is capable of causing an explosion through its own potential sources of ignition. The gearboxes from type AB, 232, 300, ILG/S and ILG/D don t have their own potential source of ignition, so directive EC 94/9/EG doesn t apply. Therefore we state that: Operation of gearboxes type series AB, 232 and 300 with the marking : II 2 G D c 120 C in areas with explosive gas atmospheres Zone I and II Category 2 (and 3) and explosive dust atmospheres Zone 21 and 22 Categories 2 (and 3) II : this product meets the requirements for explosion prevention : in a potential explosive surrounding, other than in mines, 2 : with a high level of safety, based on normal operation and anticipated risks G D c : suitable for a possible explosive atmosphere caused by gases, vapours, mists of air/dust mixtures : safety obtained by constructive solutions. 120C : indicating the maximum surface temperature in C Rotork Gears bv 4

2. Installation : mounting to the valve Following description applies to standard type gearboxes. 1. The gearbox is standard delivered in the closed position. 2. It is recommended to mount a handwheel on the input shaft before assembling the gearbox to the valve. figure 1 : mounting handwheel 3. Check if the bolt circle of the flanges (of gearbox and valve) coincide. Also check if the valve stem and the bore of the gearbox match. 4. Make sure the valve is in the closed position. If not, close the valve before continuing. 5. Check if the gearbox is in fully closed position by turning the handwheel clockwise. 6. When stud bolts are used for fixing the gearbox to the valve, it is recommended to screw them into the bottom flange of the gearbox before mounting the gearbox on top of the valve. 7. The use of a gasket between the flange of the valve and gearbox is recommended. 8. Mount the gearbox perpendicular to the valve (see figure 2). figure 2 : Gearbox perpendicular to the valve 9. Fix the gearbox to the valve with nut and ring. Where bolts are used refer to table 2 for maximum screw dept. For tightening, refer to standard VDI 2230. PCD F05 F07 F10 F12 F14 F16 F25 F30 F35 F40 max. screw depth 8 11 13 16 18 18 18 18 30 36 table 2 : maximum screw depth per pitch circle diameter 10. The assembly is now ready for adjustment. (see chapter 2). Rotork Gears bv 5

3. Adjustment of the setscrews The gearbox is mounted on top of valve (see installation). 1. Close the valve completely, by turning the handwheel clockwise. 2. The valve position is indicated by the arrow on the position indicator. 3. Remove the plastic caps from the setscrews. 4. When the fully closed position can not be achieved, loosen the setscrew-close (see figure 1) by turning them counterclockwise. Continue turning the handwheel until the valve is totally closed. 5. Screw the set-screw back into the gearbox (by turning clockwise) until tight (blocked against stud bolt). Secure the setscrew close with the nut. figure 3 : gearbox setscrew adjustment 6. Open the valve by turning the handwheel counter clockwise. 7. When it can not be achieved to open the valve completely (90 ), loosen the setscrew-open (see figure 1) by turning it counter clockwise. Continue turning the handwheel until the valve is completely opened. 8. Screw the set-screw back into the gearbox (by turning clockwise) until tight (blocked against studbolt). Secure the setscrew open with the nut. 9. Close the valve with the handwheel 10. Put the plastic caps back on the setscrews. 11. Adjustment completed. Rotork Gears bv 6

4. Operating instructions The AB models are ly operated quarter turn gearboxes made of cast iron. The 232 models are made of aluminium and the 300 range is made of stainless steel. The maximum allowable input- and output torques are listed in chapter 1.1. 1. The gearbox is ly operated by handwheel. 2. For opening the valve, the handwheel is turned counter clockwise. For closing turn the handwheel clockwise 1. 3. Stop turning when the required valve position is achieved. The number of turns needed to completely open or close the valve is in table 2. 4. The valveposition is indicated by the position indicator on top of the gearbox. 5. When the valve can not be completely opened (or closed), first detect and solve the cause of malfunction. 6. In case of malfunction of the gearbox, it has to be replaced (see chapter installation for removing) removing. Return the gearbox to your supplier for repair. 7. When you do the repair in house, all replacement parts must be obtained from the manufacturer to assure proper operation of the gearbox. 8. The gearbox is self-braking. Therefore no fixation needs to be installed to retain the valveposition 2. 9. When the fault is repaired, turn the handwheel until blocked. 10. The system is ready for use. figure 4 : gearbox model AB 1 As special we can deliver clockwise = opening, counter clockwise=closing. 2 Option is the possibility to fix the inputshaft to prevent (not allowed) turning. Rotork Gears bv 7

TYPE Numb er of turns TYPE Number of turns TYPE of gearbox Number of turns AB 150 10 AB 6800(LB)/SP6 119 232-05O 10 AB 210/215 9,25 AB 6800(LB)/SP9 176 232-05N 10 AB 550 8,5 A 200/SP9 148 232-06 10 AB 880 9,5 AB 250LT/SP9 176 232-07 9,25 AB 1250 13,75 AB 250/SP9 176 232-08 9,25 AB 1950(LB) 13 232-10 11,25 AB 1950(LB) HR 21 307 9,25 232-11 11,25 AB 1950(LB)/SP4 52 310 11,25 232-12 10 AB 6800(LB) 19,5 312 10 232-13 10 AB 6800(LB)LT/SP4 79,25 232-14 10 AB 6800(LB)/SP4 79,25 232-15 10 table 3 : number of turns for compleet opening / closing. 5. Maintenance Under normal conditions, the gearbox is maintenance free. The Rotork Gears gearboxes can be used at ambient temperatures from 20 to + 120 C. The standard gearbox from the 300- and 232 range is IP65 (dust tight and water jet proof). Cleaning can be done with a water hose, not a high pressure water jet. The standard N gearbox from the AB range reaches IP67 (dust tight and temporary immersion proof). Cleaning can be done with a high pressure water jet. Rotork Gears bv 8