Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

Similar documents
Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

Grilles & Diffusers. Series NV Non-vision grilles. Incorporating. Sight blocking design ensures privacy is maintained

Louvre systems. Series WLD Weather louvre doors. Incorporating. Fully active louvre panel integrated into a door

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide

Louvre systems. Series WLSS / WLG Stainless / galvanised steel weather louvres. Incorporating

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide.

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

Incorporating V2.1. Product spec >>> > Series WL - Standard weather louvres

Incorporating V2.0. Product spec >>> > Series NV - Non vision grilles

Blade Features. AirShield Control and Shut Off Dampers. AirShield

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

VOLUME CONTROL / REGULATING DAMPERS

Cell Ventilation Security Grille

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

CONTROL SMOKE AND BALANCING DAMPERS

Actionair Control and Shut Off Dampers

Anti-Ligature Grille. There s a much bigger picture to be found at Ruskin Air Management. Model AL/35 Model AL/24. range available.

PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper

Linear Floor Grilles Models FG, F20, F25 and FRO

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

CRP. Commissioning damper, Ductwork Leakage Class 0

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

IrisControlDamper. For Adjustment and Measuring of Airflow.

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

Floor Swirls Models BZD and SZD

Ceiling swirl diffusers

Slot diffusers, Round duct diffusers. IMP Klima

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

For installation into ductwork

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Fire Block and Pressed Steel Grilles

INDEX. Chapter3. air master. Linear Bar Grilles

LINEAR SLOT DUFFUSERS

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Ceiling swirl diffusers

Panel Floor Grilles Model LDA, MDA, HDA, PFS and F48

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

DSA HIGH EFFICIENCY DROPLET SEPARATOR DROPLET SEPARATOR DSA. With heated vanes

Multileaf damper with actuator

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

FlowBar High Capacity Slot Diffuser

NV series. Induction VAV air volume control terminals

Series HCD Airfoil Control Damper

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

MOTORIZED VOLUME DAMPER

INDEX. Chapter1 6. air master. Volume Control Dampers

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

ceiling swirl diffuser DQJ

Fitting Instructions DucoGrille Close /03/2018

Particle Filter Box FKU

INDEX. Chapter2. air master. Grilles and Registers

INDEX. Chapter1 1. A. Jet diffusers 1. Jet diffuser...: AJD-P

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

ACCESSORIES FOR DUCT FANS

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

Regulation and shut-off damper SPB and SPC

SERIES GP. Security Grilles

Technical information

Aircell Polymer Range

BL Series Louvres. Factory Assembled Louvre Panels

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4

Zero Leakage Isolation Damper

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

Fire Block and Pressed Steel Grilles

Linear Slot Diffusers Model Slot 20 and Model Slot 25

In operation At rest For wire sizing

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

SERIES GZL. High Induction Linear Diffuser (Patented)

LINEAR SLOT DIFFUSERS

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

GDD - Supply Grille. Halton GDD. Supply Grille

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

3. Dimensions and weights Placement and installation Pressure lost Material... 14

VAV TERMINAL BOXES TYPE: BA BT

DRUM JET DIFFUSERS TYPE: DJA DJB DJAP DJBP

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

Transcription:

Volume Control Dampers Incorporating Series LF upvc-vcd 2.76 m 3 /hr/m 2 leakage at 50 Pa, over 70% better than required by Part L of Building Regulations Corrosion resistant, perfect for chlorinated atmospheres or coastal areas Low U value of 1.2 W/m 2 K Low torque design Full range of actuators Available painted to any RAL or BS colour High pressure specification available tested to 2000 Pa Now tested for acoustic performance against BS EN ISO 10140-2:2010 LF upvc-vcd: September 2017

Series LF upvc-vcd The Series LF upvc-vcd is an exceptionally low leakage volume control damper, designed for use in highly energy efficient buildings and proven in independent tests to have a leakage over 70% below that currently required by Part L of Building Regulations. The plastic construction: Serves to make the whole damper a thermal break, as opposed to some rival products which attempt to modify an existing metal VCD design using thermal breaks. Is corrosion resistant. Perfect for coastal areas, chlorinated atmospheres such as swimming baths, and anywhere dampers may be exposed to elevated moisture levels. As with all HVC volume control dampers, the drive system is fully protected by being enclosed within the frame. This avoids it coming into contact with dust and debris which would adversely affect performance and warrant more frequent maintenance. LF upvc VCDs are now available with low pressure and high pressure specifications. Design features Material Sizes Frame Finish Operation Controls Extruded rigid upvc frame and blades Aluminium blade cores Stainless steel seals and fixings Minimum: 100mm x 105mm nominal Maximum single unit: 1500mm width, 1005mm height or 1005mm diameter. Above any of these, units would be made in sections or with mullions. 40mm flanges 130mm overall depth Standard: White upvc Optional: Painted to any RAL or BS colour Opposed blade, gear driven Standard: Extended spindle for motorisation by others Optional: Locking quadrant Factory fitted electronic, pneumatic or ATEX rated actuators Please see pages 5-7 for more information on controls Mass/m 2 face area Free area 17.5 kg 75% maximum Quality assurance HVC Supplies (Stourbridge) Ltd is an ISO 9001 certified company. Assessed to ISO 9001 Cert/Ref No. 1186 2 www.h-v-c.com

Low and high pressure specifications Series LF upvc VCDs are available in two specifications: Low pressure (standard) Recommended for applications with static air pressures up to 100 Pa, including all natural ventilation applications. This difference in performance is achieved by using different blade tip seals. Leakage results for both specifications are shown below. High pressure (optional) Recommended for applications with static air pressures over 100 Pa. Product testing Leakage testing Series LF upvc VCDs have been tested for air-tightness when fully closed. Part L of Building Regulations defines the maximum air permeability of a building as 10 m 3 /hr/m 2 when measured at 50 Pa. LF upvc-vcds with a low pressure specification have a leakage of 2.76 m 3 /hr/m 2 at 50 Pa, exceeding the Part L requirement by over 70%. The test damper was of nominal size 1000mm x 1005mm. Test report number G2619/7610 The testing was carried out in July 2015 by Building Testing Ltd in Surrey, England. Copies of the test report are available on request. Air leakage Static pressure (Pa) Low pressure specification High pressure specification l/s m 3 /hr/m 2 l/s m 3 /hr/m 2 25 0.40 1.43 0.60 2.15 50 0.77 2.76 0.90 3.22 75 1.00 3.58 1.13 4.05 100 1.17 4.19 1.22 4.37 150 1.57 5.62 1.47 5.26 200 1.96 7.03 1.73 6.19 250 2.09 7.48 1.81 6.49 500 3.48 12.47 3.07 11.00 750 5.32 19.05 4.27 15.29 1000 6.98 25.00 5.49 19.66 1250 9.29 33.27 6.35 22.75 1500 11.97 42.88 7.22 25.86 1750 14.18 50.80 8.24 29.51 2000 17.71 63.44 9.11 32.64 sales@h-v-c.com 3

Product testing continued Acoustic attenuation testing Series LF upvc-vcd high performance plastic volume control dampers have been tested against: BS EN ISO 10140-2:2010 Acoustics - Laboratory measurement of sound insulation of building elements - Measurement of airborne sound insulation The testing was carried out in June 2017 by Exova in High Wycombe, Buckinghamshire, England. The unit tested was of nominal size 1000mm x 1005mm. Copies of the test report are available on request. Blade setting Sound reduction figures R w (db) R w+c (db) R W+C tr (db) Fully open 2 2 2 Half open 3 3 3 Fully closed 20 20 19 4 www.h-v-c.com

Technical drawings Model A: Square flanged Model B: Square spigotted Model C: Circular spigotted Model D: Flat oval spigotted If nominal size exceeds 1500mm wide, 1005mm high, or 1005mm diameter, units will either be manufactured in sections, or have mullions to divide the blade pack. Spigots are manufactured from galvanised steel, polyester powder coated white. Manufacturing tolerance: + or - 1mm sales@h-v-c.com 5

Controls Extended spindle (standard control method unless stated) Allows fitting of an actuator by others. Stainless steel 10mm diameter Extends 45mm from gear cover plate Locking quadrant Cast aluminium locking quadrants can be fitted to enable manual operation of the VCD. Locking quadrants come with a cast-in position indicator and locking nut. 6 www.h-v-c.com

Belimo actuators We recommend the use of Belimo actuators for applications in non-specialist environments. All actuators are factory fitted and tested to confirm good operation. Other than connection to wiring, no alteration to the actuator is required on site. Please see the below table to find the series of Belimo actuator you require for your application. Suitable for LF upvc-vcds up to Voltage Action Series 0.4m 2 1.0m 2 2.0m 2 24V 230V* Power open power close Spring return Modulating LM24A LM24A-SR LM230A LM230ASR NM24A NM24A-SR NM230A NM230ASR SM24A SM24A-SR SM230A SM230ASR LF24 LF24-SR LF230 NF24A NF24A-SR NFA SF24A SF24A-SR SFA *Suitable for 240V supply. sales@h-v-c.com 7

Schischek explosion-proof actuators Schischek produce a range of specialist explosion-proof actuators for use in areas with potentially explosive atmospheres; E.G. petro-chemical plants, whisky distilleries and grain silos. ATEX approved. All actuators are factory fitted and tested to confirm good operation. Other than connection to wiring, no alteration to the actuator is required on site. Please contact us for more information on explosion-proof actuators with LF upvc-vcds. Kinetrol pneumatic actuators We can factory fit LF upvc VCDs with Kinetrol s compressed air driven pneumatic actuators. A range of additional options including spring return modules can be fitted to enhance functionality. ATEX approved. All actuators are factory fitted and tested to confirm good operation. Other than connection to pneumatic lines, no alteration to the actuator is required on site. Please contact us for more information on pneumatic actuators with LF upvc-vcds. Motor housings Unless specified, actuators are fitted outside the overall size of the VCD. It is possible to protect your damper s actuator by specifying a motor housing. A modified frame is used, which includes a protected enclosure, and upvc plates fitted either side to cover the space, one of which is left removable. The space is large enough to allow removal of the actuator in the event of failure. Please note: This will result in a loss of active damper width of 160mm with Belimo LM, NM and SM actuators. Other motor models may require larger enclosures. 8 www.h-v-c.com

Installation LF upvc VCD volume control dampers are mechanical products with moving parts, as such installation should always take into account the requirements of future maintenance, with a view to providing adequate access to dampers. If being installed into a larger assembly, please ensure provision for access is taken into account, for example through the use of removable access panels. If being installed into ductwork we are able to supply a full range of access doors to facilitate quick and easy access. Maintenance Maintenance is essential to ensure LF upvc VCDs operate satisfactorily throughout their working life. For this reason we recommend that all LF upvc VCD volume control dampers are inspected and maintained if necessary to ensure good operation at least annually. This may need to be performed more frequently should local conditions dictate it. An operation and maintenance manual (O & M) for Series LF upvc VCDs is available via: www.h-v-c.com/oandm sales@h-v-c.com 9

Finish White upvc as standard Painted to any RAL or BS colour Please note: Blade end caps, blade tip and blade side seals will remain in natural finish should you require your damper to be painted. Ordering codes Example 1-1000 x 1005 - LF upvc-vcd - Model A - Belimo NM24A-SR - MH - RAL7012 Codes 1) Quantity 2) Size (mm) (Width x height) Nominal size 3) Series LF upvc-vcd High performance plastic volume control damper 4) Model Model A Square flanged (standard) Model B Square spigotted Model C Circular spigotted Model D Flat oval spigotted 5) Pressure rating *nothing* Low pressure specification (standard, for pressures up to 100 Pa including natural ventilation) HP High pressure specification (optional, for pressures over 100 Pa) 6) Control EX Extended spindle (standard) LQ Locking quadrant (Actuator) State actuator code When ordering a spring return actuator, please specify whether you require spring open or spring close operation. 7) Motor housing MH Motor housing to protect actuator 8) Finish *nothing* White upvc (standard) RAL... Painted to RAL... BS... Painted to BS... 8 www.h-v-c.com

HVC & NCA products HVC offer the significant advantage of manufacturing both in duct and duct terminal equipment, making us a one stop shop for all your HVAC needs. The products shown below are a selection, not an exhaustive list. Go to www.h-v-c.com for details on all HVC and NCA products. HVC: Grilles, Diffusers, Louvres and Volume Control Dampers NCA: Fire and Volume Control Dampers sales@h-v-c.com 9

Assessed to ISO 9001 Cert/Ref No. 1186 HVC Supplies (Stourbridge) Ltd Jason House Amblecote West Midlands DY8 4EY United Kingdom Tel: +44 (0)1384 376555 Fax: +44 (0)1384 392555 sales@h-v-c.com All details within this brochure are correct at time of publication. However HVC s policy is one of continual product development. The right is reserved to alter any details published in this brochure without any prior notice. Any changes will appear on www.h-v-c.com as soon as is practically possible. All information in this brochure is designed to be used for informative purposes only. HVC will not be legally bound by anything contained within this publication, or any other information distributed. All references to companies not part of the HVC group of companies are used with the permission of their respective owners. www.h-v-c.com