TITAN FLOW CONTROL, INC.

Similar documents
TITAN FLOW CONTROL, INC.

2-12 Grooved End Dual Disc Check Valve. Operation, Maintenance and Installation Manual

Wafer and Globe Style Silent Check Valve. Operation, Maintenance and Installation Manual

14 and Larger Wafer and Lug Style Dual Disc Check Valve. Operation, Maintenance and Installation Manual

GA Industries, LLC 9025 Marshall Road Cranberry Township, PA USA Telephone (724) Fax (724)

720A Wafer & 821A Globe Style

Danfoss Butterfly Valve

Val-Matic 3-Way Tapered Plug Valve

740G Double Disc Check. Valve. Operation / Maintenance Manual. General Information 2. Installation/Operation 3

Val-Matic 1/2-3 Well Service Air Valve With Dual Port Throttling Device

APCO CSV-1600 SURGE CHECK VALVE

Installation, Operation, and Maintenance Manual

Val-Matic 4-20 Air/Vacuum Valve

DeZURIK 2 20" BOS BUTTERFLY VALVES

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

582 Series. Instruction Manual. Two-Door Wafer Check Valve N-582 (R-08/2016)

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Butterfly valves Figure 56 Installation & Maintenance Instructions

740G Double Disc Check Valve

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

Swing-Flex Check Valve

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

720G Wafer and 821G Globe Style Silent Check Valves

2" - 24" OS Series Butterfly Valves. Operation and Maintenance Manual. Job Name: Contractor: Date:

Operating & Maintenance Manual For Steam Conditioning Valve

Full View Flow Indicator

½"-3" Air/Vacuum Valve Models 100S to 103S

Keystone Figure 85/86 Check valves Installation and Maintenance Instructions

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

Swing-Flex Check Valve

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

DeZURIK 24" THRU 36" RESILIENT BUTTERFLY VALVES

KEYSTONE. Check valves Figure 85/86 Installation & Maintenance Instructions. Figure 85. Figure 86.

Val-Matic 3"-24" Butterfly Valve With LSA Actuator and External Stops

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

I-317. AWWA Check Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES 317 WARNING

MODEL 1100 TURBINE FLOW METER

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

24-48 HP250II Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #: 2448HP250OOOM Revision Date: 1/10/11

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

GL Ludemann Y-Strainers

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

GT-200 GATE VALVES PN16, Screwed end

Model DF269 Control Valve

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

TECHNICAL SERVICE MANUAL

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

PCSS800TE / PC800TE / PCSS800SW / PC800SW

3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

CV Control Valves Installation and Operation Manual

MODEL 900 IMPELLER-TYPE FLOW METER

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

DeZURIK KUL KNIFE GATE VALVES

INTRODUCTION INSTALLATION

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

CAST STEEL FLANGED GATE, GLOBE, & CHECK VALVES

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

PENBERTHY FROST PROOF EXTENSION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Specialty Products. Strainers. Check Valves. Butterfly Valves

KEYSTONE Figure 990/991 Butterfly valves Installation, operation and maintenance instructions

MODEL 200 MULTI-JET FLOW METER

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

KEYSTONE. Butterfly valves Figure 9 Installation & Maintenance Instructions. Please read these instructions carefully

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

V-SEGMENT SERIES V-Port Segment Control Valves (VS/VV/VM) Installation & Maintenance Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

RESILIENT SEATED CARTRIDGE STYLE BFV S

Price List. Specialty Products / Strainers / Check Valves / Butterfly Valves. Effective July 2, MuellerSteam.com 2018 MUELLER PRICE LIST

Model DF233 Control Valve

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

SERIES RSR PRESSURE RELIEF VALVE

INSTALLATION, OPERATION AND MAINTENANCE FOR SERIES 500 K-FLO BUTTERFLY VALVES

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Industrial Turbo Meters, Sizes 2" through 6"

Installation and Maintenance Manual

Effective June 1, 2013 This guide supersedes all previous versions

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

DeZURIK 2-24 (50-600mm) KGC ES or HD KNIFE GATE VALVES

Val-Matic QuadroSphere Trunnion Mounted Ball Valve

Model 585 Swing Check Valve

FASANI ASSISTED SWING CHECK VALVE BOLTED BONNET INSTALLATION AND MAINTENANCE INSTRUCTIONS

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

Operating and Installation Instructions

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Models P, P, P, , DANGER

Series 820 AWWA Butterfly Valves

Installation, Operation, and Maintenance Manual

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS

MUELLER ECCENTRIC PLUG VALVE

NECO Pumping Systems

Transcription:

PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Wafer Style, Dual Plate Check Valves. To ensure efficient and safe operation of Titan FCI Dual Plate Check Valves, the instructions in this manual should be thoroughly read and understood. This manual is general in nature and is not meant to take the place of an on-site, process engineer or pipe fitter. As such, Titan FCI recommends that only experienced, skilled personnel be allowed to install and maintain Titan FCI Dual Plate Check Valves. Please retain this manual in a location where it is readily available for reference. GENERAL INFORMATION: Titan s Dual Plate Check Valves are designed to automatically prevent back-flow in systems where it is desirable to permit flow in one direction and prevent flow in the opposite direction. When the pump starts and the downstream flow creates the required pressure drop in the forward direction, the Dual Plates will automatically open. When the pump stops and the flow ceases, the torsion of the spring will automatically close the Dual Plates prior to flow reversal. This creates a positive shutoff against flow reversal and eliminates system surges and water hammer. For additional information regarding Titan FCI s Dual Plate Check Valves, please refer to the engineering specification sheet for each model. Further information may also be obtained from Titan FCI s Double Disc, Non-Slam Check Valve Product Guide. Prior to selection of a Titan FCI Dual Plate Check Valve, the following factors must be determined: Material construction requirements of the Check Valve. Design and working pressure/temperature requirements. Operating conditions (throttling, pressure drop, condensation, flow reversal, operation frequency, etc.). Service media type (liquid, gas, abrasive, corrosive, dirty, etc). Pipeline Media Flow-rate and Viscosity. Clean Start-up Pressure of the Pipeline. Space availability for installation. Please contact a Titan Design Engineer to assist in the determination of these requirements prior to selection and purchase. Figure 1: CV 41-DI ANSI Class 150 lb Ductile Iron Body EPDM Seat Titan FCI s Dual Plate Check Valves are intended for liquid service that does not exceed 10 ft./sec. They are not recommended for steam service or flow media that contains suspended solids such as wastewater. UNPACKING AND INSPECTION: Upon receipt of product, it is important to follow these unpacking and inspection procedures. All Titan FCI Dual Plate Check Valves are shipped in specialized shipping containers designed to prevent damage during transportation. If external damage to the shipping container is evident upon receipt of product, please request that a representative of the shipping carrier be present before unpacking the product. Carefully open the shipping container, following any instructions that may be marked on the container. Remove all packing material surrounding the Check Valve and carefully lift it from the container. It is recommend to keep the shipping container and all packing material for reuse in storage or reshipment. DUAL PLATE CHECK VALVE 1 CVDIOM1015

UNPACKING AND INSPECTION: Continued... Visually inspect the Check Valve for any signs of damage including scratches, loose parts, broken parts or any other physical damage that may have occurred during shipment. If damage is observed, immediately file a claim with the shipping carrier. Check Valves that are damaged during transportation are the responsibility of the customer. For information regarding Titan FCI s warranty policy, please refer to the last page of this document. Before installation, the check valve should be inspected internally for any loose or foreign materials that may have become trapped inside the Check Valve during transportation. If the Check Valve is not required to be installed immediately, it should be stored indoors in a clean, dry, consistent temperature environment. It is also recommended to utilize the original shipping container and packing materials to properly store the Check Valve. If long term storage is required, a desiccant may be necessary. This would be based upon the local, environmental storage conditions. Additionally, rubber surfaces may require a thin film of grease. Rubber surfaces should never be directly exposed to sunlight or ozone for extended periods. Please consult a Titan FCI Design Engineer to assist in this determination. When ready to install, remove any preservatives with solvent dampened cloths. Remove any loose material and protective packing material. INSTALLATION: Pre-Installation Checklist 1 7 8 5 9 2 Figure 2: CAD Illustration PARTS LIST No. Dual Plate Check Valve 1 BODY 2 DISC 3 HINGE PIN 4 SPRING 5 NPT PLUG 6 WASHER 7 NAMEPLATE 8 SEAT 9 EYEBOLT Pre-Installation Checklist Continued... 6 3 4 DUAL PLATE CHECK VALVE 2 CVDIOM1015 Ensure Working conditions (pressure and temperature) are with in the specified capacity of the product being installed. Please refer to the Engineering Specification Sheet for each Check Valve model to determine these values. Make sure that the construction material of the Check Valve is compatible with the media flowing in the pipeline. Additionally, ensure that the service media is filtered to remove unwanted debris prior to entering the Check Valve. If the service media is not sufficiently clean, debris particles can prevent the Check Valve from sealing correctly and degrade overall performance overtime. Inspect sealing surfaces that they are clean and smooth; no nicks or cuts. The pipeline should also be checked for proper alignment. Titan FCI Check Valves should never be utilized to realign an existing piping system. For efficient function and improved service life, recognized piping standards stipulate placing Check Valves 5 to 10 pipe diameters from any turbulence producing devices (elbows, pumps, tees, expansions, reductions, and swages).

PRE Titan FCI Dual Plate Check Valves are designed for steady flow conditions and are not recommended for use in reciprocating pump, compressor or other types of physical/thermal shock-load applications. In this type of application, the Check Valve will not perform efficiently and will ultimately fail. PRE Titan FCI Dual Plate Check Valves are designed to operate properly for flow rates between 5 ft./sec. to 10 ft./sec.. It is not recommended to exceed the maximum flow rate of 10 ft./sec. or the minimum flow rate of 5 ft./sec.. PRE A Titan FCI strainer should be installed ahead of the pump to ensure protection and proper operation of the check valve and the pump. PRE A Titan FCI Dual Plate Check Valves can only be mated with pipe flanges per ANSI B16.5 & ANSI B16.1. Step 1: Remove the plastic flange protectors (if present) and other packaging materials from the Check Valve. Horizontal Installation: The valve rib must be installed perpendicular to the flow. This is shown in the diagram below. The eyebolt or plug is located directly above the valve rib can be used to correctly position the valve. Vertical Installation: It is necessary to orientate the valve rib such that there is equal loading on the Dual Plates. This is illustrated in the diagram below. Additional pressure drop should be expected due to the weight of the discs. In this position, the valve rib is perpendicular to the incoming horizontal piping which creates an unequal loading on the plates. In this position, the valve rib is parallel to the incoming horizontal piping and creates an equal loading on the plates. DUAL PLATE CHECK VALVE 3 CVDIOM1015 Figure 4: Vertical Positioning Correct Incorrect Figure 3: Horizontal Positioning For vertical installations, Dual Plate Check Valves can only be installed with flow direction upward. In the vertical position, the outlet will be above the inlet.

Step 2: Following the instructions for horizontal or vertical installation described previously, orientate the flow arrow (cast into the side of the valve body or printed on the nameplate) in the direction of the pipeline flow. In the correct position, the dual plates will move away from the valve seat, in the direction of the pipeline flow. Step 3: While supporting the existing pipeline, lift the Check Valve into position. For large or heavy Check Valves, the appropriate material handling equipment must be used in order to prevent injury and possible damage to the Check Valve. When lifting the Check Valve, utilize the eye bolt or place slings/ chains securely around the valve body. Never lift the Check Valve by attaching slings/chains to the trim/seat assembly. The trim/seat assembly is not designed to withstand the weight of the unit. Step 4: Install a standard, 1/8 thick flange gasket (in accordance with ANSI B16.5) between valve and mating flanges (on both sides). Ensure the flange gaskets are centered correctly to prevent internal leakage. Step 5: Install lubricated flange bolts and hand tighten. Flange bolts should then be tightened using a star or crisscross pattern to evenly load the bolts. This is illustrated in the diagram below. 8 1 5 3 OPERATION: Start-up Procedure: Once proper installation has been successfully completed, start the system gradually, at start up as well as after shut down. This eliminates sudden shock to the Check Valve and other equipment in the line. MAINTENANCE: Titan FCI Dual Plate Check Valves are designed to provide trouble-free service and seldom require maintenance. If removal of Check Valve is required for inspection, please follow these steps. Valve Removal Before removing the Check Valve from the pipeline, the pressure inside the vessel must be reduced to atmospheric via suction or venting. Failure to do so may result in serious bodily injury. Before removing the Check Valve from the pipeline, ensure that the media that is flowing in the pipeline is known and any special handling precautions are understood. Please review the Material Safety Data Sheet (MSDS) for that specific fluid. DUAL PLATE CHECK VALVE 4 CVDIOM1015 4 6 2 7 Step 1: To remove the Check Valve from the pipeline, first isolate the Check Valve by shutting off the upstream pump and closing the downstream isolation valve. Drain the system as much as possible. Figure 5: Bolting Sequence Step 2: Relieve pressure from both sides of the Check Valve by venting the line. Excessive bolt torque may damage the Check Valve Flanges. Please refer to established flange bolt torques.

MAINTENANCE: Continued... Step 3: Loosen the outlet side first, never loosen the inlet side first. Once pressure has bee relived, loosen inlet side. Step 4: Remove Check Valve from the pipeline and inspect the internal components for wear or damage. If replacement parts are required, please constant Titan Flow Control for repair recommendations. Trouble Shooting: Leakage: Periodic inspections for leakage should be performed. If leakage is present, check the flange gasket and flange bolt torque. In some situations, it may be necessary to isolate the Check Valve by shutting off upstream and downstream valves. Then remove the Check Valve and inspect the seating surfaces for damage. When removing the Check Valve for inspection, please follow the removal instructions presented in this manual. Always relieve pressure from both sides of the Check Valve before inspection. Vibration: Verify that flow rate is within acceptable ranges (5 ft./sec. to 10 ft./sec.). Additionally, verify that the Check Valve is 5 to 10 pipe diameters from any turbulence producing devices (elbows, pumps, tees, expansions, reductions, and swages). Slamming: Remove Check Valve from piping system and inspect the spring. Verify that the spring is providing the proper tension. Restricted Flow: If flow is halted at the Check Valve, verify that the flow direction arrow (casted into the side of the body or printed on the nameplate) is pointing in the direction of the flow. WARRANTY: Seller warrants each of the products and parts sold hereunder, under normal use of service, and subject to user s compliance with any operating instructions and other directions given by seller, to be free from defects in materials or workmanship for a period of one year from date of shipment from seller s plant. Seller s liability, under this warranty, shall be limited to, at the seller s option, to repairing or replacing any such defective product FOB seller s plant in Lumberton, NC, and reimbursing purchaser for shipping costs, subject to the following: (1) Timely receipt of purchaser s written notice that such products are defective. (2) Seller s written authorization to purchaser for the return of such products, (3) the return of such products to seller with shipping charges prepaid and (4) seller s inspection of and confirmation that such products are defective in materials or workmanship. If seller s inspection shows that the products returned are defective due to dirt, rust or any foreign material not attributable to seller: improper usage, over tightening on threads, abuse or incorrect assembly in the field, or other cause not due to seller s improper manufacture, seller will, subject to purchaser s written authorization, repair or replace such products at cost. Seller s factory inspection and testing reports will be made available to purchaser upon request. THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF FITNESS OR MERCHANTABILITY. SELLER SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. NO REPRESENTATIVE OR SELLER HAS AUTHORITY TO MAKE ANY REPRESENTATIONS OR WARRANTIES, EXCEPT AS STATED HEREIN. DUAL PLATE CHECK VALVE 5 CVDIOM1015