COILS DELTA POWER COMPANY

Similar documents
GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198

Catalog HY /US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes...

Standard Coils and Proportional Valve Coils

DRV2-080 Adjustable, Direct-Acting Relief Valve

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Solenoid Coils for Switching and Proportional Valves

ACCESSORIES ACCESSORIES VALVE BODIES... AC2 CAVITY PLUGS... AC4 MANUAL OVERRIDE OPTIONS... AC9 PILOT PISTON ASSEMBLIES... AC11

SV SOLENOID OPERATED

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Proportional Valves. Proportional solenoid valves for pressure and flow control

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Information 3 Form A 4 Industrial Form Type B 12 Form B 16 Form C 18 Micro Type C 22

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

SECTIONAL BODY. Model SV. Directional Control Valves VALVES STANDARD FEATURES SPECIFICATIONS. Parallel or Series Circuit Construction ...

PACKED SPOOL 4-WAY DIRECTIONAL CONTROL VALVE.

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Chapter 2: Directional Control Valves

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

HYDRAULIC CARTRIDGE VALVES

Direct solenoid and solenoid pilot operated valves

Genesis Series Valves Parts List / Service Instructions

SD2E-A3. Functional Description. 3/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2013. Replaces HA /2012

Proportional Flow-Control Cartridges, Size 5

TECH NOTE: E Coils Field Assessment DATE: REVISION: 1.0

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

CUSTOM ENGINEERED SWITCHES. Engineered Solutions for The Most Severe Pressure, Vacuum and Temperature Applications

COILS AND CONNECTORS. Atlantic Fluid Tech SECTION 21. Rev. 10/ Connector Page class

Directional Control Valves Accessories

Chapter 6: Check Valves

5-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow, for two pumps systems

Directional Control Valves. General Description. Features. Specifications

740 SERIES. hydraulics. Sun FLeX Series Low- & High-Power Coils LOW- & HIGH-POWER COILS: DC & AC VERSIONS WITH DIN & DEUTSCH CONNECTORS

Electrically Operated Pressure Relief Cartridge, Size 1 Seated Design, Direct Acting Series WUVA 1LO...

DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS)

CLS100 Proportional Load Sensing Mobile Valve

TRANSMISSION VALVES Slip-in configuration

Direct solenoid and solenoid pilot operated valves

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

DG 060 DG 061 DG 062 DG 063 DG 064 for Pressure and High Pressure Filters Operating pressure up to 600 bar Response/switching pressure up to 5,0 bar

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67

Proportional Pressure Reducing Valve, Size 16 Series DRPSB 5B...

Electrically Operated Pressure Reducing Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WDRVPA 5...

Chapter 10: Valves for Pipe Mounting

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Electrically Operated Pressure Relief Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WUVPA 1...

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

SOLENOID VALVES NFPA D03 NFPA D05 D03 & D05 SERIES 35- SOLENOID VALVES. Features. Internal Structure NFPA SIZE: D03 & D05

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

Prop. directional seated valve type EM 21 DE and EM 21 DSE intended as pilot valve

Chapter 6: Check Valves

Electric Actuators Maximum in-lbs

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Seated valves 500 bar

Electric Actuators Maximum in-lbs

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

Direct solenoid and solenoid pilot operated valves

Coils and electronic controls

CATALOG OF REPLACEMENT PARTS C24EA SERIES STEAMER 3-PAN BASIC. ML /240 V. 8.5kW ML V. 8.5kW 3-PAN PRO

Temperature Sensor MBT Technical brochure

Port Flow Rate/ Function Series Actuators Page Number Size Factor

CATALOG OF REPLACEMENT PARTS

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34

MS Application. Features. Proportional Valve Actuator General Instructions

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm)

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Heavy Duty Hydrostatic Transmissions

Direct solenoid and solenoid pilot operated valves

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

DIRECTIONAL CONTROL VALVE SOLENOID OPERATED TYPE HD3-ES-*-/10 CETOP MPa HD3 - ES - (1) (C) - * - (024C) (-) / 10

Functional Description

Cartridge Valves Technical Information Directional Valves DCV 03

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to Cv)

Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33

CLS180 Proportional Load Sensing Mobile Valve

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

INSTALLATION DIMENSIONS

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Electronic Proportional (EP) Control for Medium Duty Piston Pumps

40 l/min (11 GPM) p max

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

Air Line Filtration Accessories. Bulletin /USA. Finite

Actuated Valves PRICING

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

ICG Switchgear Price List 2009

Temperature sensor Type MBT 3270

P1X Series. Compact Rodless Air Cylinders Contents

CATALOG OF REPLACEMENT PARTS C24GA6 & C24GA10 GAS CONVECTION STEAMERS PRIOR MLS COVERED IN THIS MANUAL

DM2500 Series. Flanged Ball Valves SPECIFICATIONS ORDERING SCHEMATIC

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

MOUNTING BRACKETS. Dimensional Drawing - Mounting Options

SV9A-10-E - Solenoid Valve 4-way, 3-position spool type solenoid valve Up to 36 L/min (9.5 USgpm) 210 bar (3000 psi)

Direct solenoid and solenoid pilot operated valves

Transcription:

COILS COMPANY Section / Description page COIL DATA... CD3 IMMERSION PROOF... CD16 GENERAL CARTRIDGE VALVE INSTALLATION NOTES... CD19 CAD INSERTION CODES - 2D... CD20 CAD INSERTION CODES - 3D... CD22 Page CD1

Page CD2

COIL DATA STANDARD COILS TYPE ID WIDTH HEIGHT PAGE PJ 1/2 1.42 1.52 CD4 P 1/2 1.25 1.78 CD6 D 1/2 1.56 2.03 CD8 L 5/8 1.56 2.03 CD10 T 3/4 1.80 2.38 CD12 F 3/4 1.45 1.97 CD14 IMMERSION PROOF I COILS TYPE ID WIDTH HEIGHT PAGE PI 1/2 1.48 1.70 CD16 DI 1/2 1.48 1.97 CD17 LI 5/8 1.48 1.97 CD18 Page CD3

P TYPE J COIL DESCRIPTION 1/2 inch (13 mm) I.D. Coil. FEATURES One piece encapsulated design that is: Weatherproof (when applied with o-rings) No external metal shell COIL SPECIFICATION Wattage 21 Watts Nominal Duty Rating Continuous Duty ±10% rated voltage at 120 F (49 C) ambient Min Current for Actuation 80% of rated current at room temperature Magnet Wire Class H or Better for all voltages Temperature Range -40 to 392 F (-40 to 200 C) Encapsulation Material Thermo-Plastic, resistant to moisture, caustic solutions, fungus, and vibrations ORDERING INFORMATION P Approximate Coil Weight:.43 lbs (.19 kg) TERMINATIONS VOLTAGE AMP Superseal - Integral Double lead AMP Jr. Timer - Integral Metri-Pack - Integral Deutsch - Integral DT04-2P DIN 43650 (Hirschmann) JA JL JJ JM JD JH 12 24 12 VDC / 1.75 24 VDC /.875 Page CD4

Page CD5

STANDARD P TYPE COILS DESCRIPTION Standard coil data P-Type coil 1/2 I.D. FEATURES One piece water resistant encapsulated design. Numerous terminals and voltages. Coil interchangeability with Delta Series and Super Series valves. Heavy gauge color coded lead wire. Reversible coil (can be installed on cartridges in both directions with equal efficiency). Note: 1. For coil selection in extreme conditions, please look at our I coil line of invironmental coils. 2. For PB-S2I, HB-S2C & HB-S2D use nut 36202090. ORDERING INFORMATION WHEN ORDERING FILL IN ALL BOXES P Approximate Coil Weight:.72 lbs (.32 kg) BASIC MODEL NO. TERMINATION VOLTAGE P-Type One Piece Encapsulated Coil (ALL COILS DC VOLTAGE EXCEPT AS NOTED) DL Double Lead DT Deutsch on Leads DT04-2P DI Deutsch - Integral DT04-2P ML Metri-Pack on Leads (12162000) MI Metri-Pack - Integral (12162000) PL Packard on Leads (150 Series) WL Weatherpack on Leads (12010972) SS Single Spade DS Double Spade HC DIN 43650 (Hirschman) - (AC/DC) CL Conduit Lead - (AC ON LY) 06 6VDC 12 12VDC 24 24VDC 36 36VDC 48 48VDC 25 24VAC 11 110VAC 13 125VAC 22 220VAC 23 250VAC 44 440VAC 19 WATT STD. COIL Page CD6

STANDARD P TYPE COILS COIL MODEL NUMBERS: Termination PDL PSL PDS PSS PHC PCL Description Double Lead AC Double Single Double Single Hirschmann Lead Wire Lead Lead Spade Spade Connector Conduit Color Range 6VDC 3.5 12VDC 12VDC 12VDC 12VDC 12VDC 1.6 1.6 1.6 1.6 1.6 24VDC 24VDC 24VDC 24VDC.78.78.78.78 36VDC 36VDC.57.57 48VDC 48VDC.40.40 ORANGE YELLOW BLUE GREEN BROWN 24VAC 24VAC 24VAC BLUE/.92.92.92 BLACK 110VA 10VAC 110VAC RED/ 100VAC.19.19 WHITE 115VAC 125VAC 125VAC 115VAC RED.17.17 130VAC 220VAC 220VAC BLACK/ 200VAC.10.10 WHITE 230VAC 250VAC 250VAC VIOLET/ 225VAC.08.08 WHITE 260VAC 440VAC 440VAC 400VAC VIOLET.05.05 460VAC SPECIFICATIONS WATTAGE: 19 watts nominal. DUTY RATING: continuous duty ±10% rated voltage at 120 F (49 C) ambient. MINIMUM CURRENT FOR ACTUATION: 80% of rated current at room temperature. MAGNET WIRE CLASS: N for all voltages. TEMPERATURE RANGE: -40 F (-40 C) to 392 F (200 C) LEAD WIRES: 18 gauge, 24 long, 600 Volt rating, with strain relief. ENCAPSULATING MATERIAL: glass filled polyester, resistant to moisture, caustic solutions, fungus and vibration. Temperature range is -40 F (-40 C) to 392 F (200 C). COLOR IDENTIFICATION: black NOTE: Delta Power A.C. Coils incorporate integrally molded full wave rectifiers which are rated for reverse voltage peaks of 1000 volts maximum. A.C. Coils are rated 50/60 HZ. Optimum operating voltage noted. Conduit connectors on A.C. coils have a maximum torque spec of 3 Ft. Lbs. Arc Suppression Diode Available Page CD7

STANDARD D TYPE COILS DESCRIPTION Standard coil data D-Type coil 1/2 I.D. MODEL NO. FEATURES One piece water resistant encapsulated design. 1.06 [26.8] VOLTAGE Numerous terminals and voltages. Heavy gauge color coded lead wire. 1/2" ID [12.7] Each coil is reversible (can be installed on cartridges in both directions with equal efficiency). 1.84 [46.6] 1.56 [39.6] Note: For coil selection in extreme conditions, please look at our I coil line of invironmental coils. 2.03 [51.6] DDL DDS DSS DHC DCL.49.81.81 [12.4] [20.6] [20.6].73 [18.5] 1.11 [28.2] ORDERING INFORMATION DMI WHEN ORDERING FILL IN ALL BOXES D Approximate Coil Weight:.72 lbs (.32 kg) 1.71 [43.4] BASIC MODEL NO. TERMINATION VOLTAGE D-Type One Piece Encapsulated Coil (ALL COILS DC VOLTAGE EXCEPT AS NOTED) DL Double Lead DT Deutsch on Leads DT04-2P DI Deutsch - Integral DT04-2P ML Metri-Pack on Leads (12162000) MI Metri-Pack - Integral (12162000) PL Packard on Leads (150 Series) WL Weatherpack on Leads (12010972) SS Single Spade DS Double Spade HC DIN 43650 (Hirschman) - (AC/DC) CL Conduit Lead - (AC ON LY) 22 WATT STD. COIL 06 6VDC 12 12VDC 24 24VDC 36 36VDC 48 48VDC 25 24VAC 11 110VAC 13 125VAC 22 220VAC 23 250VAC 44 440VAC DDI.85 [21.6].76 [19.3] 1.75 [44.5] Page CD8

STANDARD D TYPE COILS COIL MODEL NUMBERS: Termination DDL DSL DDS DSS DHC DCL AC Description Double Single Double Single Double Lead Hirschmann Lead Lead Spade Spade Lead Wire Connector Conduit Color Range 6VDC 6VDC 6VDC 6VDC 6VDC ORANGE 3.7 3.7 3.7 3.7 3.7 12VDC 12VDC 12VDC 12VDC 12VDC YELLOW 1.8 1.8 1.8 1.8 1.8 24VDC 24VDC 24VDC 24VDC 24VDC BLUE.90.90.90.90.90 36VDC 36VDC 36VDC 36VDC 36VDC GREEN.62.62.62.62.62 48VDC 48VDC 48VDC 48VDC 48VDC BROWN.47.47.47.47.47 24VAC 24VAC 24VAC BLUE/ 1.2 1.2 1.2 BLACK 110VAC 110VAC RED/ 100VAC.23.23 WHITE 115VAC 125VAC 125VAC 115VAC RED.17.17 130VAC 220VAC 220VAC BLACK/ 200VAC.11.11 WHITE 230VAC 250VAC 250VAC VIOLET/ 225VAC.10.10 WHITE 260VAC 440VAC 440VAC 400VAC VIOLET.05.05 460VAC SPECIFICATIONS WATTAGE: 22 watts nominal. DUTY RATING: continuous duty ±10% rated voltage at 120 F (49 C) ambient. MINIMUM CURRENT FOR ACTUATION: 80% of rated current at room temperature. MAGNET WIRE CLASS: N for all voltages. TEMPERATURE RANGE: -40 F (-40 C) to 392 F (200 C) LEAD WIRES: 18 gauge, 24 long, 600 Volt rating, with strain relief. ENCAPSULATING MATERIAL: glass filled polyester, resistant to moisture, caustic solutions, fungus and vibration. Material temperature range is -40 F (-40 C) to 392 F (200 C). COLOR IDENTIFICATION: black NOTE: Delta Power A.C. Coils incorporate integrally molded full wave rectifiers which are rated for reverse voltage peaks of 1000 volts maximum. A.C. Coils are rated 50/60 HZ. Optimum operating voltage noted. Conduit connectors on A.C. coils have a maximum torque spec of 3 Ft. Lbs. Arc Suppression Diode Available Page CD9

STANDARD L TYPE COILS DESCRIPTION Standard coil data L-Type coil 5/8 I.D. FEATURES One piece water resistant encapsulated design. 1.06 [26.8] MODEL NO. VOLTAGE Numerous terminals and voltages. Heavy gauge color coded lead wire. Each coil is reversible (can be installed on cartridges in both directions with equal efficiency). 1.84 [46.6] 5/8" I.D. [15.9] 1.56 [39.6] Note: For coil selection in extreme conditions, please look at our I coil line of invironmental coils. 2.03 [51.6] LDL LDS LSS LHC LCL.49.81.81 [12.4] [20.6] [20.6].73 [18.5] 1.11 [28.2] ORDERING INFORMATION LMI WHEN ORDERING FILL IN ALL BOXES L BASIC MODEL NO. TERMINATION VOLTAGE Approximate Coil Weight:.72 lbs (.32 kg) 1.71 [43.4] D-Type One Piece Encapsulated Coil (ALL COILS DC VOLTAGE EXCEPT AS NOTED) DL Double Lead DT Deutsch on Leads DT04-2P DI Deutsch - Integral DT04-2P ML Metri-Pack on Leads (12162000) MI Metri-Pack - Integral (12162000) PL Packard on Leads (150 Series) WL Weatherpack on Leads (12010972) SS Single Spade DS Double Spade HC DIN 43650 (Hirschman) - (AC/DC) CL Conduit Lead - (AC ON LY) 22 WATT STD. COIL 06 6VDC 12 12VDC 24 24VDC 36 36VDC 48 48VDC 25 24VAC 11 110VAC 13 125VAC 22 220VAC 23 250VAC 44 440VAC LDI.85 [21.6].76 [19.3] 1.75 [44.5] Page CD10

STANDARD L TYPE COILS COIL MODEL NUMBERS: Termination LDL LDS LHC LCL Description Double Lead 12VDC 24VDC 1.8.9 Double Spade 12VDC 1.8 24VDC.9 Hirschmann Connector 12VDC 1.8 24VDC.9 110VAC.16 220VAC.08 Double Lead Conduit 110VAC.16 220VAC.08 Lead Wire Color YELLOW BLUE GREEN BROWN BLUE/ BLACK RED/ WHITE RED BLACK/ WHITE VIOLET/ WHITE VIOLET 115VAC 130VAC 225VAC 260VAC AC Range 100VAC 115VAC 200VAC 230VAC 400VAC 460VAC Data in this chart reflects current usage. Additional terminations, connections and suppression devices are available. Consult the factory for special applications. SPECIFICATIONS WATTAGE: 22 watts nominal. DUTY RATING: continuous duty ±10% rated voltage at 120 F (49 C) ambient. MINIMUM CURRENT FOR ACTUATION: 80% of rated current at room temperature. MAGNET WIRE CLASS: N for all voltages. TEMPERATURE RANGE: -40 F (-40 C) to 392 F (200 C) LEAD WIRES: 18 gauge, 24 long, 600 Volt rating, with strain relief. ENCAPSULATING MATERIAL: glass filled polyester, resistant to moisture, caustic solutions, fungus and vibration. Material temperature range is -40 F (-40 C) to 392 F (200 C). COLOR IDENTIFICATION: black NOTE: Delta Power A.C. Coils incorporate integrally molded full wave rectifiers which are rated for reverse voltage peaks of 1000 volts maximum. A.C. Coils are rated 50/60 HZ. Optimum operating voltage noted. Conduit connectors on A.C. coils have a maximum torque spec of 3 Ft. Lbs. Page CD11

STANDARD T TYPE COILS DESCRIPTION T-Type coil 3/4 I.D. FEATURES One piece water resistant encapsulated design. 1.36 [34.5] _ MODEL NO. Numerous terminals and voltages. VOLTAGE Each coil is not reversible. 1.96 [49.7] 3/4" ID [19.1] 1.80 [45.7] 2.38 [60.6] TDL.24 [6.0] TDS.45 [11.3] THC.49 [12.5] ORDERING INFORMATION WHEN ORDERING FILL IN ALL BOXES T Approximate Coil Weight:.90 lbs (.41 kg) BASIC MODEL NO. TERMINATION VOLTAGE T-Type One Piece Encapsulated Coil (ALL COILS DC VOLTAGE EXCEPT AS NOTED) DL Double Lead DT Deutsch on Leads DT04-2P ML Metri-Pack on Leads (12162000) PL Packard on Leads (150 Series) WL Weatherpack on Leads (12010972) DS Double Spade HC DIN 43650 (Hirschman) - (AC/DC) 28 WATT STD. COIL 06 6VDC 12 12VDC 24 24VDC 36 36VDC 48 48VDC 25 24VAC 11 110VAC 22 220VAC Page CD12

STANDARD T TYPE COILS COIL MODEL NUMBERS: Termination TDL TDS THC Description Double Lead 12VDC 24VDC 36VDC 48VDC 2.33 1.17.78.58 Double Spade 12VDC 24VDC 36VDC 48VDC 2.33 1.17.78.58 Hirschmann Connector 12VDC 24VDC 36VDC 48VDC 2.33 1.17.78.58 Lead Wire Color BLACK RED BLUE GREEN AC Range Data in this chart reflects current usage. Additional terminations, connections and suppression devices are available. Consult the factory for special applications. 25VAC 1.75 RED/ BLUE 25VAC 120VAC.31 RED/ BLUE 115VAC 130VAC 240VAC.15 RED/ BLUE 225VAC 260VAC SPECIFICATIONS WATTAGE: 28 watts nominal. DUTY RATING: continuous duty ±10% rated voltage at 120 F (49 C) ambient. MINIMUM CURRENT FOR ACTUATION: 80% of rated current at room temperature. MAGNET WIRE CLASS: N for all voltages. TEMPERATURE RANGE: -40 F (-40 C) to 392 F (200 C) LEAD WIRES: 18 gauge, 24 long, 600 Volt rating, with strain relief. ENCAPSULATING MATERIAL: glass filled polyester, resistant to moisture, caustic solutions, fungus and vibration. Material temperature range is -40 F (-40 C) to 392 F (200 C). COLOR IDENTIFICATION: black NOTE: Delta Power A.C. Coils incorporate integrally molded full wave rectifiers which are rated for reverse voltage peaks of 1000 volts maximum. A.C. Coils are rated 50/60 HZ. Optimum operating voltage noted. Page CD13

STANDARD F TYPE COILS DESCRIPTION T-Type coil 3/4 I.D. FEATURES One piece water resistant encapsulated design. Numerous terminals and voltages available. Internal arc suppression diodes available on request. Color identification: metallic envelope. FHC FJT FDT ORDERING INFORMATION WHEN ORDERING FILL IN ALL BOXES F Approximate Coil Weight:.49 lbs (.22 kg) MODEL TERMINATION VOLTAGE F (proportional coil type) (ALL COILS DC VOLTAGE EXCEPT AS NOTED) HC DIN 43650 (Hirschman) DI Deutsch Integral DT04-2P JT Junior Timer 12 12VDC 24 24VDC 22 220VAC without internal rectifier (for HC termination only) Page CD14

STANDARD F TYPE COILS COIL MODEL NUMBERS: Termination FHC FDI FJT Description Hirschmann connector Deutsch Integral Junior Timer / 12 V / 1,66 A 12 V / 1,66 A 12 V / 1,66 A / 24 V / 0,83 A 24 V / 0,83 A 24 V / 0,83 A / 220 VAC rectified / 0,10 A SPECIFICATIONS WATTAGE: 20 watts nominal. DUTY RATING: continuous duty ±10% rated voltage at 120 F (49 C) ambient. MINIMUM CURRENT FOR ACTUATION: 80% of rated current at room temperature. MAGNET WIRE INSULATION: class H (200 C). HEAT INSULATION: class H (180 C). AMBIENT TEMPERATURE RANGE: -30 C +60 C PROTECTION DEGREE: IP 65 (with connector and suitable seals). LEAD WIRES: 600 Volt rating, with strain relief. ENCAPSULATING MATERIAL: glass filled polyester, resistant to moisture, caustic solutions, fungus and vibration. Metallic parts protected against oxidation. A.C. coils do not include the rectifier, supply voltage must be externally rectified Page CD15

IMMERSION PROOF P TYPE I COILS DESCRIPTION 1/2 inch (13 mm) I.D. Short Immersion Proof Coil. 1.48 [37.5] PART.98 [25.0] FEATURES One piece encapsulated design that is: Weatherproof Immersion proof Thermal shock / dunk tested No external metal shel 1.70 [43.1] XXXXX COIL SPECIFICATION Wattage Duty Rating 20 Watts Nominal Continuous Duty ±10% rated voltage at 120 F (49 C) ambient VOLTAGE 1.54 [39.0] Min Current for Actuation Magnet Wire Class 80% of rated current at room temperature H or Better for all voltages Temperature Range -40 to 392 F (-40 to 200 C) Protection degree Up to IP 65 (with connector and suitable seals) Encapsulation Material Thermo-Plastic, resistant to moisture, caustic solutions, fungus, and vibrations.64 [16.4].57 [14.5].82 [20.8].27 [6.8].57 [14.4] 1.93 [49.1].81 [20.6].82 [20.8] 2.05 [52.0].75 [19.0] 1.60 [40.6].48 [12.1] IA IJ ID IM ORDERING INFORMATION P Approximate Coil Weight:.43 lbs (.19 kg) TERMINATIONS VOLTAGE AMP Superseal - Integral Deutsch - Integral DT04-2P AMP Junior Timer - Integral Metri-Pack - Integral IA ID IJ IM 12 24 1.6 Yellow Lettering.80 Blue Lettering NOTE: Pull type valves require nut 36202073 in lieu of standard nut. Push type valves require nut 36202071 in lieu of standard nut, except for PB-S2I, HB-S2C & HB- S2D use nut 36202090. Page CD16

IMMERSION PROOF D TYPE I COILS 1.48 [37.5] PART.98 [25.0] DESCRIPTION 1/2 inch (13 mm) I.D. Immersion Proof Coil. FEATURES One piece encapsulated design that is: Weatherproof Immersion proof Thermal shock / dunk tested No external metal shel 1.97 [50.0] XXXXX COIL SPECIFICATION Wattage Duty Rating 24 Watts Nominal Continuous Duty ±10% rated voltage at 70 F (21 C) ambient VOLTAGE 1.54 [39.0] Min Current for Actuation Magnet Wire Class 90% of rated current at room temperature H or Better for all voltages Temperature Range -40 to 392 F (-40 to 200 C) Encapsulation Material Thermo-Plastic, resistant to moisture, caustic solutions, fungus, and vibrations.64 [16.4].57 [14.5].82 [20.8].27 [6.8].57 [14.4] 2.20 [56.0] 1.08 [27.5] 1.09 [27.7] 2.32 [59.0] 1.02 [26.0] 1.87 [47.5].75 [19.0] IA IJ ID IM ORDERING INFORMATION D Approximate Coil Weight:.49 lbs (.22 kg) TERMINATIONS VOLTAGE AMP Superseal - Integral Deutsch - Integral DT04-2P AMP Junior Timer - Integral Metri-Pack - Integral IA ID IJ IM 12 24 12 VDC / 2.0 Yellow Lettering 24 VDC / 1.0 Blue Lettering NOTE: Pull type valves require nut 36202073 in lieu of standard nut. Push type valves require nut 36202071 in lieu of standard nut. Page CD17

IMMERSION PROOF L TYPE I COILS DESCRIPTION 5/8 inch (16 mm) I.D. Immersion Proof Coil. 1.48 [37.5] 1.97 [50.0] VOLTAGE PART # 1.48 [37.5] 1.97 [50.0] VOLTAGE XXXXX PART # 1.54 [39.0].98 [25.0] XXXXX 1.54 [39.0].98 [25.0] FEATURES One piece encapsulated design that is: Weatherproof Immersion proof Thermal shock / dunk tested No external metal shel COIL SPECIFICATION Wattage Duty Rating Min Current for Actuation Magnet Wire Class Temperature Range Encapsulation Material 26 Watts Nominal Continuous Duty ±10% rated voltage at 120 F (49 C) ambient 80% of rated current at room temperature H or Better for all voltages -40 to 392 F (-40 to 200 C) Thermo-Plastic, resistant to moisture, caustic solutions, fungus, and vibrations.64 [16.4].57 [14.5].82 [20.8].27 [6.8].57 [14.4] 2.20 [56.0] 1.08 [27.5] 1.09 [27.7] 2.32 [59.0] 1.02 [26.0] 1.87 [47.5].75 [19.0] IA IJ ID IM ORDERING INFORMATION L Approximate Coil Weight:.49 lbs (.22 kg) TERMINATIONS VOLTAGE AMP Superseal - Integral Deutsch - Integral DT04-2P AMP Junior Timer - Integral Metri-Pack - Integral IA ID IJ IM 12 24 12 VDC / 2.2 Yellow Lettering 24 VDC / 1.1 Blue Lettering NOTE: Pull type valves require nut 36202073 in lieu of standard nut. Push type valves require nut 36202071 in lieu of standard nut. Page CD18

GENERAL CARTRIDGE VALVE INSTALLATION NOTES CARTRIDGES Inspect the cartridge to assure there is no external contaminant present. Check O-rings and back-up rings to assure they are intact and in the correct position. The O-rings should always be toward the high pressure port or between doubled back-up rings on bi-directional applications. COILS It is sometimes easier to remove the coil from the cartridge valve to install terminations or make connections with conduit, etc. If this is the case, reinstall the coil by tightening the coil nut to 4-6 ft lbs per spec sheet. CAUTION: DO NOT OVER TORQUE Tube will be stretched and damaged, causing valve to fail. VALVE BODIES Check the cartridge brochure to assure correct plumbing. Inspect the cavity for burrs and any irregular machining which would damage 0-rings at assembly. Shims may be required behind the block for panel mounting. ASSEMBLY Dip the cartridge in clean oil before installing. Screw the cartridge in by hand until the top 0-ring is touching the manifold, then wrench tighten to the proper torque specification given below. TORQUE SPECIFICATIONS Final Cartridge Tightening: Adjusting Holding Parts: Series Torque Part Torque 5/8 MINI 10-15 ft-lbs 3/4 POWER 20-25 ft-lbs Nut 3-5 ft-lbs Knob 3-5 ft-lbs 7/8 DELTA 25-30 ft-lbs 1 1/16 TECNORD 60-70 ft-lbs 1 5/16 SUPER 80-90 ft-lbs Cap 2-3 ft-lbs Page CD19

DDL12 12 VDC COILS CAD INSERTION CODES - 2D MECHANICAL VALVES The insertion codes for mechanical valves are based on the first seven digits of the valve mnemonic code number. The eighth digit represents the direction of the view. Mnemonic Always use 0 (zero) INSERTION CODES M A R V A 0 K E D E F C A 0 0 S View codes: E = End (top) view F = Front or back view S = Side view DERVA0KE (END) Mnemonic option codes: 0 = no visible options K = Knob I = Internal adjustment T = Tamper proof DERVA0KF (FRONT) DERVA0KS (SIDE) SOLENOID VALVES COIL VIEWS View code: E = End (top) F = Front B = Back R = Right L = Left Series code: M = Mini P = Power A = Power 4W3P Delta Coil B = Power 4W3P Power Coil D = Delta L = Delta 4W3P T = Tecnord "D" Type Coil H = Tecnord "T" Type Coil High Pressure S = Super The connector code is not used for back views CODE F D D L Connector code: DL = Double Lead SL = Single Lead DS = Double Spade SS = Single Spade DP = Double Post SP = Single Post HC = Hirschmann CL = Conduit Lead DC = Deutsch Integral Connector IA = Integral Superseal ID = Integral Deutsch IMMERSION IM = Integral Jr. COILS IM = Integral Metri-Pack BACK LEFT FRONT RIGHT For Proportional Valve views: EEPRD00 DL L Model Number View code: Connector code: END MANUAL OVERRIDES View code: C = Normally Closed O = Normally Open P = 4W3P Push-only B = Bi-directional CODE F D Series code: P = Power PI = Power w/ "I" Coil D = Delta DI = Delta w/ "I" Coil T = Tecnord S = Super CD EXAMPLE PP NORMALLY OPEN VALVE COIL NUTS FMNUT MINI SERIES NUT SMNUT FNUT SNUT POWER, DELTA, TECNORD AND SUPER SERIES NUT FINUT SINUT POWER, DELTA, AND TECNORD IMMERSION COIL NUTS HYDRAULIC SYMBOLS C V A Third, fourth, and fifth digits of mnemonic CVA S2A Page CD20

CAD INSERTION CODES - 2D CAVITIES PORTS S N E E 1 3 2-4 View code: E = End (top) S = Side H = Hidden (side) E 0 0 0 0 Last four digits of form tool P/N. Port code: S = SAE N = NPT View code: E = End (top) S = Side H = Hidden (side) Size code NPT Examples: 1/16-27 = 1-16 3/4-14 = 3-4 1 1/4-11 1/2 = 11-4 NE3-4 NS3-4 SAE SIZES AVAILABLE NPT SIZES AVAILABLE E0000 S0000 #2 SAE #3 SAE #4 SAE #5 SAE #6 SAE #8 SAE #10 SAE #12 SAE #14 SAE #16 SAE #20 SAE #24 SAE #32 SAE 1/16" NPT 1/8" NPT 1/4" NPT 3/8" NPT 1/2" NPT 1" NPT 1 1/4" NPT 1 1/2" NPT 2" NPT SAE PLUGS PLUGS NPT PLUGS CAVITY PLUGS 1 2 S S 3-4 E N P E Size code: View code: S = Side E = End (top) Size code: Series code: M = Mini P = Power D = Delta T = Tecnord S = Super View code: F = Front S = Side E = End (top) 12ES 12SS 3-4EN SIZES AVAILABLE SIZES AVAILABLE END SIDE #2 SAE #3 SAE #4 SAE #5 SAE #6 SAE #8 SAE #10 SAE #12 SAE #14 SAE #16 SAE #20 SAE #24 SAE #32 SAE 1/16" NPT 1/8" NPT 1/4" NPT 3/8" NPT 1/2" NPT 1" NPT 1 1/4" NPT 1 1/2" NPT 2" NPT FRONT BODIES D 2 M 3 W S W N Series code: M = Mini P = Power D = Delta T = Tecnord S = Super Port code: S = SAE N = NPT Style code: 2W = two way 3W = three way 4W = four way 5W = five way D2WS M3WN CONSULT FACTORY FOR FORMAT AVAILABILITY Page CD21

CAD INSERTION CODES - 3D CARTRIDGE VALVES INSERTION CODES MARVA0K D E S2A0M Mnemonic Always use 0 (Zero) Mnemonic option codes: Mechanical valve options: 0= No visible options K= Knob I= Internal adjustment T= Tamperproof Solenoid valve options: 0= No visible options K= Manual override, Knob type I= Manual override T= Manual override, Push only COILS INSERTION CODES D ID PDS Series code: M= Mini P= Power D= Delta, Tecnord & Super L= Delta 4W3P T= Tecnord High Pressure Coil termination: CL= Conduit lead DI= Integral Deutsch DT04-2P MI= Integral Metripack DL= Double leads DP= Double post DS= Double spade DT= Deutsch on leads DT04-2P HC= DIN 43650 (Hirschmann) ML= Metripack on leads (12162000) WL= Weatherpack onleads (12010972) IA= I coil, integral AMP Superseal ID= I coil, integral Deutsch DT04-2P IJ= I coil, integral AMP Jr. Timer IM= I coil, integral Metripack COIL NUTS MINI Series: Normally open: 36202005 Normally closed: 36202018 POWER, DELTA, TECNORD & SUPER Series: Normally open: 36202020 Normally closed: 36202017 Normally open w/ I coil: 36202071 Normally closed w/ I coil: 36202073 TECNORD High Pressure Series: Normally closed: 36202059 4W3P Coil nuts: Power Series: 36202047 Delta Series: 36202046 BODIES INSERTION CODES Series code: M= Mini P= Power D= Delta T= Tecnord S= Super D2WS M3WN Port code: S= SAE N= NPT Style code: 2W= Two way 3W= Three way 3WS= Three way short 4W= Four way 5WS= Five way short CAVITY PLUGS INSERTION CODES Series code: DE00 SL00 Will always be 00 (Zero) MINI MA= Mini 2W MC= Mini 3W MD= Mini 4W POWER PB= Power 2W PP= Power 3W PQ= Power 4W DELTA DE= Delta 2W DF= Delta 3W DG= Delta 4W TECNORD TT= Tecnord 2W TU= Tecnord 3W TR= Tecnord 3WS TV= Tecnord 4W SUPER SJ= Super 2W SK= Super 3W SL= Super 3WS SM= Super 4W SO= Super 5WS Page CD22