Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Similar documents
Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 6213 EV, 6281 EV

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

Type 2000, 2002, 2012

Type 3320, Service Manual. Serviceanleitung Service Manuel

Type /2-way globe valve 2/2-Wege-Geradsitzventil Vanne à siège droit 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Pneumatic Control Unit. Operating Instructions

Type Pneumatic Control Unit. Operating Instructions

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 2030, 2031, 2031 K, 2032, 2033, 2037

Type 2730, 2731, 2731 K DN Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 3360, Service Manual. Serviceanleitung Service Manuel

Type 3232, 3233, 3233 K, 3234, 3235, 3239

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 8635 Remote-Positioner. Zusatzanleitung. English Deutsch Français

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Type 8798 Remote Sensor. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 2030, 2031, 2031 K, 2032, 2033, 2037

BVS 13 ATEX E039X Type 8685 / Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 2060, 2061, 2063, 2064, Accessories. Zubehör Accessoires

Solenoid Valve DF-SB-series

Solenoid Valve ST-SA-series

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

2/2 or 3/2 way direct acting rocker solenoid valve

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Ex m Solenoid Operator Type 0519

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

2/2- and 3/2-way solenoid valve for aggressive fluids

3/2-way Solenoid Valve for pneumatics

Solenoid Valve ST-IA-series

Direct-acting 3/2 way plunger valve

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Angle seat valve with diaphragm actuator VZXA-...-M

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

Type 8644 AirLINE. Operating Instructions. Bedienungsanleitung Manuel d utilisation. With decentralized peripheral system ET200S (Siemens)

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Angle seat valve with piston actuator VZXA-...-K

Direct-acting 2/2- or 3/2-way pivoted armature valve

Solenoid Valve DF-SA-series

Angle seat valve with piston actuator VZXA-...-K

Solenoid valves VZWP, servo-controlled

Direct-acting 2/2-way plunger valve

2/2-way Globe Valve for media up to +180 C, DN

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Declaration of Conformity as per Directive 97/23/EC

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

2/2-way Globe Valve for media up to +180 C, DN

Installation, Operation, and Maintenance Manual

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

Solenoid Operator 0516 / 1216

Type 8644 AirLINE. Operating Instructions. Bedienungsanleitung Manuel d utilisation. with I/O System 750 (Wago)

Operating Instructions for Paddle Bellows Flow Monitor. Model: FPS-P...

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Operating pressure (bar) kv factor (m 3 /h) *3)

Pressure relief valve

Swing Piston Compressors and Vacuum Pumps

Solenoid Operator 0513 / 1213

Mounting and Operating Instructions EB 5868/5869 EN

2/2-way Solenoid Valve with servo diaphragm

2/2-way Solenoid Valve for liquids and gases

3/2-way Miniature Rocker Solenoid Valve for pneumatic systems

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

2/2 way Angle-Seat Valve for medium up to C, DN15-50

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Operating Instructions

2/2 or 3/2 way direct acting rocker solenoid valve

Remote Process Actuation Control System AirLINE - Siemens ET 200S

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Operating Instruction for Flowmonitor. Model: DF-WM

Type Control Head. Operating Instructions

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

2/2 or 3/2-way Miniature Rocker Solenoid Valve

Micro Diaphragm Gas Sampling Pumps

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Installation, Operation, and Maintenance Manual

Multi Way Valves for Pneumatics Servo Assisted, Extendable, 10mm Wide

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Transcription:

Type 0283, 0293 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Contents 1 The operating instructions...2 2 Intended use...3 3 Basic Safety Instructions...4 4 Technical Data...5 5 Installation...7 6 Maintenance, Troubleshooting...9 7 Spare parts...10 8 Transport, Storage, Disposal...11 1 THE OPERATING INSTRUCTIONS The operating instructions contain important information. Read the instructions carefully and follow the safety instructions in particular. Keep the instructions in a location where they are available to every user. The liability and warranty for Type 0283, 0293 are void if the operating instructions are not followed. 1.1 Symbols Designates instructions for risk prevention. Designates a procedure which you must carry out. Warning of injuries: DANGER! Immediate danger! Serious or fatal injuries. WARNING! Possible danger! Serious or fatal injuries. CAUTION! Danger! Moderate or minor injuries. Warning of damage: NOTE! 2

2 INTENDED USE The solenoid valve Type 0283 and Type 0293 is designed for dosing, blocking, filling and aerating media. Type 0293 is classified in accordance with DIN EN 161 Group 2, Class B for gas. Use according to the permitted data, operating conditions and conditions of use specified in the contract documents and operating instructions. These are described in the chapter entitled Technical Data. Provided the cable plug is connected and installed correctly, e.g. Bürkert Type 2508, the device satisfies degree of protection IP65 in accordance with DIN EN 60529 / IEC 60529. Do not physically stress the device (e.g. by placing objects on it, using it as a screwing aid, standing on it or using it as a lever arm). The device may be used only in conjunction with third-party devices and components recommended and authorised by Bürkert. Use device only when in perfect condition and always ensure proper storage, transportation, installation and operation. Use the device only as intended. 2.1 Definitions of terms The term "device" always refers to the solenoid valve Type 0283 or Type 0293. 3

3 BASIC SAFETY INSTRUCTIONS These safety instructions do not make allowance for any contingencies and events which may arise during the installation, operation and maintenance of the devices. Danger high pressure. Before loosening the lines and valves, turn off the pressure and vent the lines. Risk of electric shock. Before reaching into the device, switch off the power supply and secure to prevent reactivation! Observe applicable accident prevention and safety regulations for electrical equipment! Risk of burns/risk of fire if used continuously through hot device surface. Keep the device away from highly flammable substances and media and do not touch with bare hands. Risk of injury due to malfunction of valves with alternating current (AC). Sticking core causes coil to overheat, resulting in a malfunction. Monitor process to ensure function is in perfect working order! General hazardous situations. To prevent injury, ensure that: The system cannot be activated unintentionally. Installation and repair work may be carried out by authorized technicians only and with the appropriate tools. After an interruption in the power supply or pneumatic supply, ensure that the process is restarted in a defined or controlled manner. The device may be operated only when in perfect condition and in consideration of the operating instructions. The general rules of technology apply to application planning and operation of the device. Do not make any modifications to the device. Do not paint the housing parts or screws. 4

4 TECHNICAL DATA 4.1 Conformity Type 0283 and Type 0293 conforms with the EC Directives according to the EC Declaration of Conformity (if applicable). 4.2 Standards The applied standards, which verify conformity with the EC Directives, can be found on the EC-Type Examination Certificate and / or the EC Declaration of Conformity (if applicable). 4.3 Type label (Examples) Orifice Circuit function Type Fig. 1: Made in Germany 0283 A 20,0 EPDM MS G3/4 PN0-0,3bar 220-230V50Hz 16W 00053523 W13ME Order number Type label solenoid valve type 0283 (Example) Seal material Body material Port connection, pressure range Voltage, frequency, power consumption Orifice Circuit function Type 0293 A 25,0 NBR MS G1 PN0-0,15bar 230V AC/DC 100/9W IP65 Ventilklasse B CE-0085AS0390-15 C +60 C 00279480 W13ME Order number Fig. 2: Made in Germany Type label solenoid valve type 0293 (Example) 4.4 Degree of protection Seal material Body material Port connection, pressure range Voltage, frequency, power consumption Degree of protection*, classification EC Examination Certificate, Temperature range *) see chapter 4.4 Degree of protection Provided the cable plug is connected and installed correctly, e.g. Bürkert Type 2508, the device satisfies degree of protection IP65 in accordance with DIN EN 60529 / IEC 60529. Type 0283 and type 0293: Cable plug e.g. Bürkert Type 2508 5

4.5 Operating conditions The values indicated on the rating plate must be observed during operation of the device. Circuit function of the direct-acting 2/2-way solenoid valve: A (NC) 2 (A) 1 (P) Permitted media Type Seal material Closed in rest position by spring force. Permitted media 0283 NBR Neutral media, compressed air, water, hydraulic oil FKM Per solutions, hot oils EPDM Oil and grease-free media, e.g. hot water 0293 NBR Valve group 2, Class B: Fuel gases of the 1st, 2nd and 3rd gas family Permitted medium and ambient temperature Type Seal Permitted ambient Permitted media material temperature NBR 10...+90 C 0283 FKM 0...+100 C max. 55 C EPDM 30...+100 C 0293 NBR 15...+80 C 15...+60 C Dirt trap Type 0283: To ensure that the solenoid valve functions reliably, a dirt trap ( 500 µm) must be installed upstream of the valve inlet. Type 0293: The necessary dirt trap is integrated into the valve. Service life High switching frequency and high pressures reduce the service life. 6

4.6 Electrical Data Note the voltage and current type as specified on the rating plate. Connection: Type 0283 and type 0293: DIN EN 175301-803 Form A for cable plug Type 2508 Power supply: see type label Voltage tolerance: ±10 % Switching frequency: AC max. 150/min UC max. 15/min 5 INSTALLATION 5.1 Safety instructions DANGER! Risk of injury from high pressure in the system/device. Before working on the system or device, switch off the pressure and vent/drain lines. Risk of injury due to electrical shock. Before working on the system or device, switch off the power supply and secure to prevent reactivation. Observe applicable accident prevention and safety regulations for electrical equipment. WARNING! Risk of injury from improper installation. Installation may be carried out by authorized technicians only and with the appropriate tools. Risk of injury from unintentional activation of the system and an uncontrolled restart. Secure system from unintentional activation. 7

Following installation, ensure a controlled restart. Risk of short-circuit or escape of media through leaking screw joints. Ensure seals are seated correctly. Carefully screw together coil and device socket or valve and pipelines. NOTE! Caution risk of breakage. Do not use the coil as a lever arm. Hold the device with an open-end wrench on the housing and screw into the pipeline. 5.2 Fluid installation Follow the safety instructions under 5.1. Installation can be in any position, preferably actuator upright. Before installation, clean any possible dirt off the pipelines. For Type 0283 install a dirt filter ( 500 µm) upstream of the valve inlet (Type 0293 already has the dirt filter integrated in the valve). Seal the pipe connection with PTFE tape. Attention: The PTFE tape must not get into the device. Observe direction of flow (see Fig. 3 ). Fig. 3: Identification of flow direction Identification for flow direction 8

5.3 Electrical installation WARNING! Danger of electrical shock if the protective conductor contact between the coil and housing is missing. Always connect protective conductor. Follow the safety instructions under 5.1 and observe the voltage and current type specifications on the rating plate. max. 1 Nm Seal Authorized cable plug e.g. Type 2508 or other suitable cable plug in accordance with DIN EN 175301-803 Form A 6 MAINTENANCE, TROUBLESHOOTING DANGER! Risk of injury from high pressure in the system/device. Before working on the system or device, switch off the pressure and vent/drain lines. Risk of injury due to electrical shock. Before working on the system or device, switch off the power supply and secure to prevent reactivation. Observe applicable accident prevention and safety regulations for electrical equipment. WARNING! Risk of injury from improper maintenance. Maintenance may be carried out by authorized technicians only and with the appropriate tools! Risk of injury from unintentional activation of the system and an uncontrolled restart. Secure system from unintentional activation. Following maintenance, ensure a controlled restart. Fig. 4: Connection of the cable plug example Type 0293 9

The solenoid valve Type 0293 is DVGW certified. Only Bürkert may carry out repairs. Malfunctions If malfunctions occur, check whether: the device has been installed according to the instructions, the connections are correct, the device is not damaged, all screws have been tightened, the voltage and pressure have been switched on, the pipelines are clean. If the magnet does not pick up, ensure that: there is no short-circuit or coil interruption, the core / core area is not dirty. If the valve still does not switch, please contact your Bürkert Service. 7 SPARE PARTS CAUTION! Risk of injury and/or damage by the use of incorrect parts. Incorrect accessories and unsuitable spare parts may cause injuries and damage the device and the surrounding area. Use only original accessories and original spare parts from Bürkert. The solenoid valve Type 0293 is DVGW certified. Only Bürkert may carry out repairs. The following spare parts or spare parts sets are available for the solenoid valve Type 0283: Coil Housing Seal set SET 2 Wear parts set SET 3 When placing an order, specify the spare part as well as the order number of your device (see rating plate). 10

Seal set SET 2 Coil Wear parts set SET 3 Housing 8 TRANSPORT, STORAGE, DISPOSAL NOTE! Transport damages. Inadequately protected equipment may be damaged during transport. During transportation protect the device against wet and dirt in shock-resistant packaging. Avoid exceeding or dropping below the allowable storage temperature. Incorrect storage may damage the device. Store the device in a dry and dust-free location! Storage temperature 40...+55 C. Damage to the environment caused by device components contaminated with media. Observe applicable regulations on disposal and the environment. Dispose of the device and packaging in an environmentally friendly manner. Fig. 5: Overview of replacement spare parts solenoid valve Type 0283 11

Bürkert Fluid Control Systems Sales Center Christian-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel. + 49 (0) 7940-10 91 111 Fax + 49 (0) 7940-10 91 448 E-mail: info@buerkert.com International address www.burkert.com Manuals and data sheets on the Internet: www.burkert.com Bedienungsanleitungen und Datenblätter im Internet: www.buerkert.de Manuels d'utilisation et fiches techniques sur Internet : www.buerkert.fr Bürkert Werke GmbH & Co. KG, 2010-2017 Operating Instructions 1703/08_EU-ml_00805786 / Original DE www.burkert.com