ACUMENTRICS CORPORATION 1000 Watt Rugged-UPS TM with optional 24 VDC 250 Watt Output

Similar documents
Power Distribution Units

Power Distribution Units AP9560 & AP9561

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

MM-AVR UPS Series User s Manual

IQS300 Series Quasi-Sine Inverter. Installation & Operation Manual

DC to DC Step Up Converter Model: VTC305

VTC610 Series Voltage Converter. Installation & Operation Manual

VTC1000 Series Voltage Converter. Installation & Operation Manual

BroadBand PowerShield. 20 AHr Battery. User Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

Installation & Operation Manual PWS1000R Rack Mount Power Supply

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL VTC1505 SERIES VOLTAGE CONVERTER

CTFRP Series Power Supplies

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

INSTALLATION & OPERATION MANUAL PWS1505 SERIES POWER SUPPLIES

INSTALLATION & OPERATION MANUAL VTC605 SERIES VOLTAGE CONVERTER

Installation Power Management Unit Battery Cables and Battery Harness

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Operation Manual. English. APC Smart-UPS VA 3U Rack and Stack Uninterruptible Power Supply 230 Vac , Revision 1 12/00

USER MANUAL English / Español

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

IPS1000 Series Pure-Sine Inverter

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

PROwatt 150 DC to AC Power Inverter. Owner s Guide

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

ALLIANCE SERIES OWNER'S MANUAL

User's Manual. Rack/Tower Extended Runtime Battery Packs

Item no Smart AC 200 USB. User s Manual

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

ADI-125/750 ADI-125/1500 ADI-125/2500

Audi R8. Ride-on Car 5F62630 OWNER S MANUAL. Keep instructions for future reference

! "! User Manual Myers Power Products CTEP/G Manual 6/2009

CP900EPFCLCD User s Manual K

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

Broadband PowerShield. CP27U Models. User Manual

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Pure Sine Wave Inverter 600W-24V User Manual

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

BRAVO Inverter/Battery Charger. Table of Contents

MICROCARE 3 PHASE INVERTER MANUAL

M ilitary G rade U ninterruptible P ower S upply

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

UniStar II Royalton Rd. Cleveland, OH USA Voice: (440) Fax: (440) Internet:

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

QPET, QPETXU Battery Chargers

O W N E R ' S M A N U A L

User Guide IGD Series

MIL-24/2600Q MIL-24/3200DQ

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Grid Tied Limiter User Manual

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

S150,S300 Series Pure Sine Wave Inverter User s Manual

OWNERS MANUAL JANUARY 2007 ISO

WARNINGS, CAUTIONS AND NOTES

Uninterruptible Power Supply

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

User s Manual Legend SB825 UPS K

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

PR1000ELCD / PR1500ELCD User s Manual

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

Operating Instructions for PAC800 Battery Charger

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

Back-UPS CS Back-UPS CS 350

PowerSure TM Personal XT USER MANUAL 450, 700, 1250 VA 230V. English / Deutsch / Français / Italiano / Español

Powerware Vdc Extended Battery Cabinet User s Guide.

OBE, OBEXU, ON BOARD Battery Chargers

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

WF-5100 Series True Sine Wave Inverters

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

DC to AC Power Inverters

QSSE, QSSEX INDUSTRIAL Battery Chargers

DC to AC Power Inverters

Limousin II User Manual

BCD600 Series Battery Charger DC. Installation & Operation Manual

The Power of Reliability INSTRUCTION MANUAL

User Manual Rittal PMC UPS 6kVA

BATTERY PACK. User's Manual

Go Power! Manual. GP-Smart Charger

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

OWNERS MANUAL JANUARY 2007 ISO

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

M ilitary -G rade U ninterruptible P ower S upply

WF-5110R True Sine Wave Inverter

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

Retrofit Kit 1 OM.qxd 12/7/ :06 AM Page 1. Owner s Manual. Medical-Grade Mobile Power Retrofit Kit Model #: HCRK-1

Transcription:

ACUMENTRICS CORPORATION 1000 Watt Rugged-UPS TM with optional 24 VDC 250 Watt Output ACG1250U-52B 97-0057 Rev I

1. INTRODUCTION Welcome Thank you for purchasing this Rugged-UPS TM uninterruptible power supply. This UPS was designed for world wide deployment in harsh and rugged environments. Please save packing materials. The UPS s shipping materials are designed to provide the necessary protection during shipping. These materials must be used if you ever have to return the UPS for service. Damage sustained during transit is not covered under warranty. Operation Topology AC Input Input EMI Filter Universal Power Factor Corrected Boost Converter DC/AC Inverter Isolation Transformer Output EMI Filter 115 VAC, 60 Hz* 1250VA *230, 50HZ for international model DC Input Input EMI Filter DC/DC Boost Converter With Galvanic Isolation 400 VDC BUS DC/DC Converter 24 VDC, 250 W* *for -24 models only Removable Battery Pack DC/DC Boost Converter With Galvanic Isolation Constant Current & Constant Voltage Battery Charger with Galvanic Isolation This unit is an ON-LINE Power Factor Corrected (PFC), Uninterruptible Power Supply (UPS). This UPS accepts wide range voltage and frequency inputs to allow it to provide clean, reliable AC power to the computer equipment connected to it. The UPS is continually creating the AC output from a high voltage DC bus, thus protecting your equipment from surges, spikes, brownouts, blackouts and noise. Charge Battery The UPS charges its battery when connected to utility power. For best results, charge the battery 4 hours before use. It is acceptable to use the UPS without first charging the battery, but on battery run time maybe shorter until the battery fully charges. Contents are copyrighted by. All rights reserved; reproduction in whole or in part with out permission is prohibited. Rugged-UPS is a registered trademark of. All other trademarks are the property of their respective owners. 2

2. SAFETY UPS SAFETY GUIDELINES To reduce the risk of electric shock, disconnect the Uninterruptible Power Source from the mains before installing a computer interface signal cable (when used). Reconnect the power cord only after all signaling interconnections have been made. Connect the Uninterruptible Power Source to a two-pole, three-wire grounding mains receptacle. The receptacle must be connected to appropriate branch protection (fuse or circuit breaker). Connection to any other type of receptacle may result in a shock hazard and may violate local electrical codes. This Uninterruptible Power Source has an internal energy source (the battery) that cannot be de-energized by the user. The output may be energized when the unit is not connected to a mains supply. To properly de-energize the Uninterruptible Power Source in an emergency, move the I/O switch to the O (off) position and disconnect the power cord from the mains. Avoid installing the Uninterruptible Power Source in locations where there is water or excessive humidity. Do not allow water or any foreign object to get inside the Uninterruptible Power Source. Do not put objects containing liquid on or near the unit. To reduce the risk of overheating the Uninterruptible Power Source, avoid exposing the unit to the direct rays of the sun. Avoid installing the unit near heat emitting appliances such as a room heater or stove. Warnings This Uninterruptible Power Source contains potentially hazardous voltages. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Repairs are performed only by factory trained service personnel. The Uninterruptible Power Source uses batteries. The batteries will eventually become too weak to provide rated autonomous operation. To obtain battery replacement or repair service, please call the Customer Service telephone number written on the front or back cover of this manual for information on the Service Center nearest you. 3

3. Package Purchase Options Domestic Model Options (120VAC/60Hz Output) Model Ships with ACG26BP Ships with ACG52BP 24 Volt DC Output 250 Watts U.S. Navy Shipboard Approved ACG1250U ACG1250U-24 X ACG1250U-SH X ACG1250U-24-SH X X ACG1250U-26B X ACG1250U-52B X ACG1250U-24-26B X X ACG1250U-24-52B X X ACG1250-24-26SH X X X ACG1250-24-52SH X X X ACG1250U-26B-SH X X ACG1250U-52B-SH X X 4

4. DISPLAYS AND FUNCTIONS Front Display ACG1250U, ACG1250U-SH AC Circuit Breaker LED Display Panel ON/OFF DC Input AC Input AC Output TVSS Fan Filter Communications Interface Hot Swappable, User Replaceable Battery Pack Front Display ACG1250U-24, ACG1250-24-SH AC Circuit Breaker LED Display Panel ON/OFF DC Input AC Input AC Output TVSS Fan Filter 24 Volt DC Output Communications Interface Hot Swappable, User Replaceable Battery Pack 5

NOTE: ALL POWER CONNECTIONS USE MILITARY STYLE TWIST LOCK CONNECTORS CONNECTIONS Input/Output Cable Type Connector Type AC Input Accepts an ACG9200 cable MS3470L14-4P AC Output Accepts an ACG9201 cable MS3470L14-4S DC Input Accepts an ACG9202 cable MS27472T16F6P DC Output Accepts an ACG9203 cable MS3470L14-4S AC Output IEC Accepts an ACG9207 cable MS3470L14-4S Communications Port Used for UPS monitoring DB9 SWITCHES/ BREAKERS ON/OFF - AC Input Breaker - Powers the unit as well as turns on\off audible alarm. Trips when the loads exceed the UPS s capacity. LED DISPLAY PANEL Battery Status Meter - Displays the present battery charge in volts DC (Range 20-28 VAC). Load Meter - Displays the power being drawn by the load (Range 0-1000 watts). Overload - This LED lights when the loads connected to the UPS exceed the UPS s capacity. On Internal DC - The unit is supplying power to the loads for the internal batteries. Over Temperature - This LED lights when the UPS internal operating temperature has exceeded specifications. On AC - The unit is supplying power to the loads for the AC connection source. ON External DC - The unit is supplying power to the loads from the external DC connection source. Replace Battery - This LED lights when the battery has reached the end of its usable life. 6

MIL-STD-810E Specifications Environmental Temperature: Operating: 0 o F to 120 o F (-18 o C to 49 o C) Storage: -25 o F to 150 o F (-32 o C to 66 o C) Shock: 0 o F to 70 o F (-18 o C to 21 o C) and 120 o F to 70 o F (49 o C to 21 o C) in 10 minutes Turn-on: From 0 o F to 40 o F (-18 o C to 4 o C) in 10 minutes; above 40 o F (4 o C) instantaneous Humidity: Altitude: Vibration: Shock/Drop: Rain: 10 to 95% (non-condensing) 0 to 15,000 ft. (operating) 0 to 40,000 ft. (non-operating) Operation and transport in HHMMWV and tracked vehicles 30 o rotational (without transit cases). 3 drops form 3 ft. (in transit case) Operation in conditions of blown precipitation and spillage Sand and Dust: Tilt: Fungus: EMI: HAEMP: 3.5 mph, 20 minutes Operations stationary, 30 o incline on any axis No nutrients/contaminants MIL-STD-461C, Notice 2, CE03, CS02, CS06, RE02, and RS03 Quadripartite Standardization Agreement-244 (Classified) This unit complies with FCC A testing 7

5. SPECIFICATIONS Input Specifications Input AC Voltage Frequency Input Power Factor Input Circuit Breaker Rating Input DC Voltage Maximum DC Current Simultaneous AC and DC inputs DC input Connector AC input Connector Output Specifications Continuous Output Power Values 80-280 VAC 47-63Hz 0.8 Minimum 20 A 22 to 31 VDC 70 A AC takes precedence over DC which takes precedence over battery Matrix Series MS27472T16F6P Connector Matrix Series MS3470L14-4P Connector Values 1000 W or 1250 VA (includes both AC and DC) Load Crest Factor 2.5 Continuous AC Output Voltage (ACG1250U/U-24/-SH) 115 VAC +/- 5% AC Output Frequency (ACG1250U/U-24/-SH) 60 Hz. +/- 5% AC Output Waveform Sinusoidal DC Output 250 Watt/24 VDC +/- 5% AC Output Connector Matrix Series MS3470L14-4S Connector DC Output Connector Matrix Series MS3470L14-4S Connector Mechanical Values Size Chassis: 16"wide x 16" deep x 6"tall Envelope: 17"wide x 17"deep x 6.25" tall Weight 36 lbs. (no batteries); 84 lbs. (max. battery pack) Shipping Size 21"wide x 21"deep x 12"tall Shipping Weight 45 lbs. (no batteries); 95lbs. (max. battery pack) Finish Lusterless Light Gray (36492) 8

Pin Out Specifications: Note: Acumentrics does not warranty the ACG1250U, ACG1250U-SH, ACG1250U-24, and the ACG1250U-24-SH against damages caused by cables manufactured by any parties other than the. Legend: Signifies Pin Signifies Pin Receptacle AC Input Pin Out Functionality: (ACG1250U, ACG1250U-SH, ACG1250U-24, and ACG1250U-24-SH) Plug Part Number MS3476W14-4S To Neutral B A D To line To Ground Not Used C 9

AC Output Pin Out Functionality: (ACG1250U, ACG1250U-SH, ACG1250U-24 and ACG1250U-24-SH only) Warning DO NOT USE THIS CABLE IN A 230VAC APPLICATION Plug Part Number MS3476W14-4P To Ground D A B To line To Neutral Not Used C 10

DC Input Pin Out Functionality: (ACG1250U, ACG1250U-SH, ACG1250U-24, and ACG1250U-24-SH) Plug Part Number MS27473T16B6S A E +28 VDC Input +28VDC Return B F D C DC Output Pin Out Functionality: (ACG1250U-24, and ACG1250U-24-SH only) Plug Part Number MS3476L14-04P Black-Negative D A B Not Used Not Used White-Positive C 11

Communications Interface Pin Out Functionality (DB9): The DB9 connector is a 9 pin D type female with the following RS232 level: TRUE = SPACE = +7.5V or greater FALSE = MARK = -7.5V or less 5 4 3 2 1 9 8 7 6 Pin 1- Low battery warning. Goes TRUE if the battery voltage indicates less than 10% hold up time. Pin 2- Not utilized Pin 3- AC power good. TRUE if AC input is viable. Pin 4- External shutdown input. When TRUE shuts down inverter. Pin 5- Signal ground common. Pin 6- Not utilized Pin 7- Not utilized Pin 8- Source fail. Goes TRUE if input power (AC or DC) fails or exceeds acceptable limits and UPS is operating on internal DC (battery backup). Pin 9- Over temperature warning. Goes TRUE if internal temperature of UPS exceeds safe upper limit. Rugged-UPS DB9 Interface Description Comm Port Comm Port (Front View of the ACG1250U) (Front View of the ACG1250U-24) 12

Interface for the ACG1250U, ACG1250U-SH, ACG1250U-24, and ACG1250U-24-SH: The Comm Port is an RS232 compatible interface through a nine pin D type connector. This port provides UPS and input power status information to the operator. UPS shutdown capability is provided as well. Mechanical Size: chassis: 16 wide x 16 deep x 6 tall envelope: 17 wide x 17 deep x 6.25 tall Weight: 35 pounds (no batteries); 85 pounds with maximum battery pack Finish: Lusterless Light Gray (36492) 16 16 6 Removable battery pack 5.5 16 8.25 13

6. ACCESSORIES Batteries: The ACG1250U, ACG1250U-24, ACG1250U-SH and ACG1250U-24-SH do not ship with batteries. There are two optional battery packs that can be used with these units, the ACG26BP and the ACG52BP. Not all installations will require internal batteries if you have the capability to utilize the external DC connections to the unit or if you plan to use the unit as an inverter. Load (watts) Typical Minutes of Runtime ACG26BP ACG52BP 100 106 212 200 65 131 300 36 72 400 22 44 500 16 33 600 13 28 700 11 23 800 9 19 900 8 16 1000 7 14 The ACG26BP has a recharge time of 2 hours to 90% capacity from full discharge. The ACG52BP has a 4 hour recharge time to 90% capacity from full discharge. 14

Cables: ACG9200 ACG9201 ACG9202 ACG9203 ACG9207 AC input cable AC output cable DC input cable DC output cable AC output cable for IEC style connectors (230VAC output) *Cable set combinations are available call or email for model numbers *Note: warranty is void if damage is caused by third party cables are used Front Fan Filter Cover *See Appendix A for servicing instructions Front fan sand and dust filter Rack mount Kits 15

ACG9011 Rack mount kit for standard 19 cabinets with depths from 22-34 ACG9012 Slide rail rack mount kit for standard 19 cabinets with depths from 20-26 ACG9013 Slide rail rack mount kit for standard 19 cabinets with depths from 26-32 16

7. BATTERY STORAGE AND MAINTENANCE The proper storage of batteries can not be overemphasized. Improper battery storage is the most common form of battery misuse. All batteries exhibit a loss of charge over time even when stored in an open circuit condition. This is called self-discharge. Both chemical and electrochemical reactions within the battery cause this consumption of the stored energy. The rate of reaction, and therefore self-discharge, increases as a function of temperature. If the batteries are stored long enough without a periodic replenishment of charge, an irreversible loss of battery capacity can occur, causing premature battery failure. All Acumentrics battery packs are shipped fully charged. They should be stored separately from the UPS and used on a FIFO (First In, First Out) basis. All battery packs should be recharged before use if 100% capacity is required. The stored battery packs should be kept on a maintenance program and should be recharged periodically according to the recommendations shown in table 1. Battery packs can be recharged using the UPS. Table 1 Storage temperature and Supplementary Recharge Intervals Storage Temperature Below 20 C (68 F) Recharge Interval Every six months Between 20 C and 30 C (68 F and 86 F) Every three months Over 30 C (86 F) Storage to be avoided The battery OCV (Open Circuit Voltage) can be used as an indicator of battery pack residual capacity. When measuring the OCV, the battery pack should not have been charged or discharged within the past 24 hours. A supplemental recharge should be performed if the battery pack OCV is 24.6 volts or less when measured at 25 C (77 F). 17

8. BATTERIES AND RECYCLING The batteries used by this Uninterruptible Power Source are recyclable. Proper disposal of the batteries is required. The batteries contain lead and pose a hazard to the environment and human health if not disposed of properly. Please refer to local codes for proper disposal requirements or return the unit to a factory-authorized Service Center for battery replacement or disposal. Battery replacement should be performed or supervised by personnel familiar with the danger of batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing batteries, use the same number and type of sealed lead acid batteries as were originally contained in your UPS. Caution - Do not dispose of battery in fire. The batteries may explode. Caution - Do not open or mutilate the battery or batteries. They contain an electrolyte that is toxic and harmful to the skin. Caution - A battery can present a risk of electrical shock and high short circuit current. When replacing batteries, wristwatches and jewelry such as rings should be removed. Use only tools with insulated handles. 18

9. WARRANTY INFORMATION Limited Warranty warrants its products to be free from defects in materials and workmanship for a period of one year from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from Acumentrics. Products must be returned to Acumentrics with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. The product must be shipped back in the original packaging. This warranty does not apply to equipment, which has been damaged by accident, negligence, or miss-application or has been altered or modified in any way. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase. EXCEPT AS PROVIDED HEREIN, ACUMENTRICS CORPORATION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL ACUMENTRICS BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Acumentrics is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may also have other rights, which vary from state to state. 19

10. LIFE SUPPORT USE INFORMATION Life Support Policy As a general policy, does not recommend the use of any of its products in life support applications where failure or malfunction of the Acumentrics product can be reasonably expected to cause failure of the life support device or to significantly effect its safety or effectiveness. Acumentrics does not recommend the use of any of its products in direct patient care. Acumentrics will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Acumentrics that (a) the risks of injury or damage have been minimized, (b) the customer assumes all such risks, and (c) the liability of Acumentrics is adequately protected under the circumstances. Examples of devices considered to be life support devices are neonatal oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), auto transfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pace makers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants, anesthesia ventilators, and infusion pumps as well as any other devices designated as critical by the U.S. FDA. 20 Southwest Park, Westwood, MA 02090 Phone (781) 461-8251 Fax (781)-461-1261 20

Appendix A Optional Front Fan Filter Servicing Instructions The front fan filter purchased with the ACG1250U or ACG1250U-24 has been designed to reduce the amounts of sand, dirt and dust, which can enter the unit via the fan. For this filter to operate effectively it must be serviced monthly. If the unit is being utilized in a harsh or dusty environment servicing should be more frequent. To service the filter the following steps should be followed: 1. Remove the fan filter from the unit by gently pulling the top left and right hand corners of the filter out. Once these corners are removed pull the filter cover gently off the fan cover 2. Once the filter cover is removed from the unit, the soft mesh can be removed from the filter housing and taped to remove loose dirt then rinse with warm water. If the filter mesh is extremely caked with dirt, a mild soap can be used to assist in the cleaning. 3. Once the mesh has been washed dry it thoroughly. 4. Place the clean dry mesh into the fan housing. 5. Place the fan filter back onto the unit by pressing firmly in the center on all four sides. Be sure the fan filter snaps into all four groves, which are on each side of the fan cover. 21