Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C1040 PDFC-4M PDFC-4L

Similar documents
Proportional Flow-Control Cartridges, Size 5

Pressure Reducing Valves

2/2 Solenoid Cartridge Valve, Size 10

3/2 Solenoid Cartridge Valve, Size 6

3/2 Solenoid Cartridge Valve, Size 6

Proportional Pressure Reducing Valve, Size 16 Series DRPSB 5B...

Electrically Operated Pressure Relief Cartridge, Size 1 Seated Design, Direct Acting Series WUVA 1LO...

2/2 Cartridge Seat Valve, Size 5

Electrically Operated Pressure Relief Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WUVPA 1...

Electrically Operated Pressure Reducing Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WDRVPA 5...

2/2 Logic Cartridge Valve, Size 10

2/2 Solenoid Cartridge Valve, Size 6

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

2/2 Logic Cartridge Valve, Size 10

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Proportional Valves. Proportional solenoid valves for pressure and flow control

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Pressure Control Valves

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

Check Valve, Size 04 16

SR1A-A2. Functional Description HA /2012. Directly Operated Pressure Relief Valves. Replaces HA /2010. Screw-in cartridge design

Pressure Relief Valve

SD3E-B2. Functional Description. 2/2 Way Solenoid Operated Directional Control Valves Poppet Type HA /2012. Replaces HA /2010

Proportional Directional Valve System

Check Valves, Size Spherical Poppet-type, Screw-in Design Series RKVE l/min, 350 bar (500 bar)

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

SD2E-A3. Functional Description. 3/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2013. Replaces HA /2012

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB

Cartridge Valves Technical Information Directional Valves DCV 03

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Directional Control Valves

3/2 ways/positions flow diverters L (VS91-VS92-VS95)

Chapter 2: Directional Control Valves

VER03MP CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34

PRPM2-A. = 5.5 Nm (4.1 lb.-ft.) (qual. 8.8 Nm (6.5 lb.-ft.) for socket cap screws. = 50 Nm (36.9 lb.-ft.) for cartridges

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

Differential Lock Valve

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2014. Replaces HA /2013

VEP03MSV-PDRP CONTINENTAL HYDRAULICS 3-WAY PROPORTIONAL PRESSURE REDUCING/RELIEVING VALVES

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type DRE05SK

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

DRV2-080 Adjustable, Direct-Acting Relief Valve

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

Directional Seat Valve Series D4S (Denison)

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE

Proportional Pressure Reducing Valve PDM08130

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 SK (high-performance)

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

VER03M CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES VER03M - PROPORTIONAL PRESSURE RELIEF VALVES

VEP03MSV-PDRP -3-WAY PROPORTIONAL PRESSURE REDUCING/RELIEVING VALVES

Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ)

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95

ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES

P.C. Priority Flow Control Valve Series J02D3. General Description

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance)

Post-Compensated Proportional Valve CV2000LS

Stand alone 4/3, 4/2 solenoid operated directional valve

Prop. directional seated valve type EM 21 DE and EM 21 DSE intended as pilot valve

Directional Control Valve Series 4D01 (DENISON)

Pilot-Operated Directional Control Valves Series D3 - D11

Leak-Free Load-Control Valve NS 32, Cartridge Design

6 to14/2 ways/positions bankable flow diverters flangeable

Directional Control Valve Series D3W Soft Shift

Proportional pressure relief valve, directly operated, rising characteristic curve

CLS100 Proportional Load Sensing Mobile Valve

4/3-4/2 Directional valve elements LF1_1 (LC1F-Z)

PRESSURE CONTROLS TECNORD

Available manual, pneumatic, and hydraulic spool control kits.

4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING

4/3, 4/2 proportional directional valves solenoid operated (for open loop control)

PRM2-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013. Size 06 p max 350 bar Q max 40 L/min

3/2 ways/positions flow diverters

6 to14/2 ways/positions bankable flow diverters flangeable

Directional Control Valve Series D1VW

6/2 ways/positions flow diverters

Safety for Hydraulics

4/3 and 4/2 on-off directional valve elements L8511 with flow (EDC-DZ) sharing control (LUDV concept) L8511 (EDC-DZ)

Chapter 5: Flow Valves

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)

6 to14/2 ways/positions bankable flow diverters flangeable

6/2 ways/positions flow diverters

Pressure Control Valves

VER*SP CONTINENTAL HYDRAULICS PROPORTIONAL PILOT RELIEF VALVES VER*SP - PROPORTIONAL PILOT RELIEF VALVES

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2012. Replaces HA /2010

Flow control valve range

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces:

Transcription:

Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4 b a PDFC-4M 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C040 4 3 b a PDFC-4L 3 3 EPRR-0 PROPORTIONAL PRESS. REDUCING/RELIEVING GPM C030 EPRT-08 PROPORTIONAL PRESS. REDUCING/RELIEVING 7 GPM C0830/AM 3 3 EPRS-0 EPRS- PROP. P.O. PRESSURE REDUCING/RELIEVING GPM 4 GPM C030 C30 ERVP-0 ERVP- PROPORTIONAL P.O. PRESSURE RELIEF 5 GPM 60 GPM C00 C0 ERVD-0 PROPORTIONAL PRESS. RELIEF, LOW FLOW GPM C00 EPFI-0 EPFI- EPFC-6 PROPORTIONAL PRESS. COMP. FLOW CONTROL 8 GPM C00 5 GPM C0 0 GPM C60 3 EPFB-0 EPFB- EPFD-6 PROP. PRIORITY PRESS. COMP. FLOW CONTROL 8 GPM C030 5 GPM C30 0 GPM C630 PFCV-0 PFCV- PFCV-6 PROPORTIONAL NON-COMP. FLOW CONTROL 6 GPM 4 GPM 36 GPM C00 C0 C60 Reference: 50-P-0000-EN-0/0.06

Proportional Valves 3 MODEL DESCRIPTION FLOW CAVITY MDR3GN PROPORTIONAL 3/ THROTTLE CARTRIGE 8 GPM AM 3 MDR4A PROPORTIONAL 4 / THROTTLE CARTRIGE 8 GPM AN 4 MVRPSBA-G PROPORTIONAL THR OTTLE CARTRIGE 3 GPM C080/AL IN REG PIFC-0 PIFC- PIFC-6 PROP. FLOW CONTROL WITH COMPENSATOR 6 GPM 4 GPM 36 GPM C00 C0 C60 IN PBFC-0 PBFC- PBFC-6 PROP. PRIORITY FLOW CONTROL WITH COMP. 6 GPM 4 GPM 36 GPM C030 C30 C630 REG B-P PWM-400 PWM-40 PWM-404 PWM MICRO PROPORTIONAL VALVE DRIVER PWM PROPORTIONAL DRIVER, COIL MOUNTED PWM PROPORTIONAL DRIVER CONTROL BOX Reference: 50-P-0000-EN-0/0.06

4/3 Proportional Directional Valve, Size SAE 0 Q max = 8.0 gpm [30 l/min], p max = 4000 psi [80 bar] Direct acting, sliding-spool design, with solenoid operation Series PDFC-0 Description Series PDFC 0 proportional directional valves are direct acting screw in cartridges with a sliding spool design and a 7/8 4 UNF mounting thread. In the neutral position, port 3 is closed and depending on the spool type, ports and 4 are connected to tank () (spool configuration M) or ports, and 4 are all blocked (spool configuration L). The version with the M spool is used in motor control circuits where free wheeling in the neutral position is required. The L configuration is the version to use for cylinder applications. These cartridges are particularly suitable for precise and controlled lifting and lowering movements and can also be used for reliable operation in mobile and industrial applications. Best controllability is achieved when using the valve with a bypass pressure compensator to control pressure drop through the valve. Using the valve without pressure Compact construction for cavity type C040 7/8-4 UNF Operated by a proportional high pressure wet-armature solenoid Minimum current threshold/ dead band (position b) is factory set for better consistency Manual over-ride optionally available, detented in neutral position Excellent reproducibility and repeatability, and low hysteresis All external parts zinc plated, passivated (CrVI-free) The slip-on coil can be rotated, and it can be replaced without opening the hydraulic envelope Various plug-connector systems and voltages are available Can be fitted in a line-mounting body compensator is not recommended because higher pressure drops cause the flow to be more restricted (see performance graph). The proportional directional valves is optionally equipped with a manual over ride which is detented in the neutral position. To unlatch the detent mechanism, the button on the back can be pushed. That allows shifting the valve in both directions. Pushing the knob shifts the valve to position (a) (3 and 4 ) and pulling shifts it to position (b) (3 4 and ). All external parts of the cartridge are zinc plated and chromited (CrVI-free). The slip-on coils can be replaced without opening the hydraulic envelope and can be positioned at any angle through 360. If you intend to manufacture your own cavities or are designing a line-mounting installation, please refer to the section Related data sheets. Symbol 4 4 4 4 b a b a b a b a 3 3 3 3 PDFC-0- -4M-M PDFC-0- -4L-M PDFC-0- -4M-0 PDFC-0- -4L-0 Reference: 50-P-300-EN-0 Issue: 07.04 /5

3 Technical data General characteristics Description, value, unit Designation 4/3 proportional directional valve Design sliding-spool design, direct acting, with solenoid operation Mounting method screw-in cartridge 7/8-4 UNF Tightening torque 40 45 ft-lbs [54 6 Nm] Size size SAE 0, cavity type C040 Weight.65 lbs [0.75 kg] Mounting attitude unrestricted (preferably vertical, coil down) Ambient temperature range -5 F +5 F [-5 C +50 C] Hydraulic characteristics Maximum operating pressure - ports, 3, 4 - port Maximum flow rate - port 3 4 and - port 3 and 4 Description, value, unit 4000 psi 000 psi higher pressure, please consult BUCHER [80 bar] [40 bar] 7.0 gpm at p 40 psi [6 l/min at p 0 bar] 6. gpm at p 40 psi [4 l/min at p 0 bar] at 00% duty cycle Leakage flow rate (port to port) 5 inch 3 at 3000 psi [45 ml/min at 0 bar] Hydraulic fluid HL and HLP mineral oil to DIN 5 54; for other fluids, please contact BUCHER Hydraulic fluid temperature range -5 F +60 F [-5 C +70 C] Viscosity range Minimum fluid cleanliness Cleanliness class to ISO 4406 : 999 5 380 mm /s (cst), recommended 0...30 mm /s (cst) class 8/6/3 Electrical characteristics Supply voltage Control current Power consumption at max. control current Coil resistance R - cold value at 0 C - max. warm value Recommended PWM frequency (dither) Hysteresis with PWM Reversal error with PWM Sensitivity with PWM Reproducibility with PWM Description, value, unit V DC, 4 V DC V = 0 400 ma, 4 V = 0 750 ma (00% duty cycle) V = 0 600 ma, 4 V = 0 880 ma (50% duty cycle) max. 9 W V = 5.8 / 4 V = 0.9 V = 9. / 4 V = 3.7 00 Hz 5 % I N 5 % I N <.5 % I N < 3 % p N Relative duty cycle 00 % / 50 % Protection class to EN 60 59 Electrical connection IP 65 / IP 67 / IP 69K, see Ordering code (with appropriate mating connector and proper fitting and sealing) 3-pin square plug to ISO 4400 / DIN 43 650 (standard) for other connectors, see Ordering code /5 50-P-300-EN-0/07.04 Series PDFC-0

4 Performance graphs Q = f (I; p) Flow rate adjustment characteristic 4M Q [gpm] B) A) 0 9 8 3 0 EL_P009.ai A) B) Coil b, connections 3 4 ; I [ma] Coil a, connections 3 ; 4 Q [l/min] [38] 7 [6] p = 45 psi p = 45 psi 6 p = 90 psi [3] p = 90 psi 5 [9] 4 p = 75 psi p = 75 psi [5] p = 450 psi p = 900 psi p = 450 psi p = 900 psi 000 900 800 700 600 500 400 300 00 00 0 00 00 300 400 500 600 700 800 900 000 000 800 600 400 00 000 800 600 400 00 0 00 400 600 800 000 00400 600 800 000 A) 00% duty cycle B) 50% duty cycle --- depending on coil temperature, solenoid may draw a voltage higher than the nominal voltage [34] [30] [] [7.5] [3.5] Q = f (I; p) Flow rate adjustment characteristic 4L Q [gpm] B) A) 0 9 8 3 0 EL_P009.ai A) B) Coil b, connections 3 4 ; I [ma] Coil a, connections 3 ; 4 Q [l/min] [38] 7 [6] p = 45 psi p = 45 psi 6 p = 90 psi [3] p = 90 psi 5 [9] 4 p = 75 psi p = 75 psi [5] p = 450 psi p = 900 psi p = 450 psi p = 900 psi 000 900 800 700 600 500 400 300 00 00 0 00 00 300 400 500 600 700 800 900 000 000 800 600 400 00 000 800 600 400 00 0 00 400 600 800 000 00400 600 800 000 A) 00% duty cycle B) 50% duty cycle --- depending on coil temperature, solenoid may draw a voltage higher than the nominal voltage [34] [30] [] [7.5] [3.5] p = f (Q) Pressure drop - Flow rate characteristic 4M Q [gpm] 8 7 6 5 4 3 7 4M, coil a 750 [ma] Valve completly open p [bar] 55 85 0 40 70 95 4M, coil b 750 [ma] 30 6 3 9 5 8 4 Q [l/min] p = f (Q) Pressure drop - Flow rate characteristic 4L Q [gpm] 8 7 6 5 4 3 7 p [bar] 55 85 0 40 70 95 4L, coil a 750 [ma] Valve completly open 4L, coil b 750 [ma] 30 6 3 9 5 8 4 Q [l/min] 0 P000.ai 400 800 00 600 000 400 800 p 3 4[psi] p 3 [psi] 0 0 P00.ai 400 800 00 600 000 400 800 p 3 4[psi] p 3 [psi] 0 50-P-300-EN-0/07.04 Series PDFC-0 3/5

5 Dimensions & sectional view 4/3 proportional directional valve 9.4 [34,7] 8. * [06,].50 [63,6] 6.74 [7,] 3 4 a b 8 5 7 4 7 6 3 6 7/8 4 UNF /6 Ma = 40...45 ft lbs [54...6 Nm] Ma = ft lbs [3 Nm] Seal kit. Push button to unlatch manual over-ride Item Qty. Description b a. Push or pull on whole handle to shift valve to position a or b 4 O-ring 6 x O-ring no. 90 0.755 x 0.097 [9,8 x,46] 3 O-ring no. 06 0.64 x 0.070 [5,60 x,78] 4 O-ring no. 05 0.55 x 0.070 [4,00 x,78] 5 O-ring no. 04 0.489 x 0.070 [,4 x,78] 6 Backup ring.634 x.05 x.047 [6,0 x,3 x,9] 7 Backup ring.57 x.05 x.047 [4,53 x,3 x,9] 8 Backup ring.50 x.05 x.047 [,95 x,3 x,9] * overall length without manual over-ride.4 [36].4 [6,] IMPORTANT! Item no. 507300 = Seal kit NBR (Buna) Item no. 5073003 = Seal kit FKM (Viton) 6 Installation information ATTENTION! Only qualified personnel with mechanical skills may carry out any maintenance work. Generally, the only work that should ever be undertaken is to check, and possibly replace, the seals. When changing seals, oil or grease the new seals thoroughly before fitting them. IMPORTANT! When fitting the valves, use the specified tightening torque for the mounting bolts. No adjustments are necessary, since the cartridges are set in the factory. 4/5 50-P-300-EN-0/07.04 Series PDFC-0

7 Ordering code PDFC - 0 - N - 4M - A - M - 0-4 D _ PDFC = proportional directional valve 0 = nominal size SAE 0 N = NBR (Nitrile) seals (standard) V = FKM (Viton) seals (special seals - please consult BUCHER) 4L = cylinder spool, all ports closed in neutral 4M = motor spool, and 4 connected to tank in neutral A = factory set min current threshold at position b M = with manual over-ride 0 = without manual over-ride 0 = cartridge only 0BA = line-mounting body G/4 BSPP aluminum 0BS = line-mounting body G/4 BSPP steel 03BA = line-mounting body G3/8 BSPP aluminum 03BS = line-mounting body G3/8 BSPP steel 06TA = line-mounting body SAE-#6 aluminum 06TS = line-mounting body SAE-#6 steel 08TA = line-mounting body SAE-#8 aluminum 08TS = line-mounting body SAE-#8 steel... = voltage e.g. 4 (4 V) D = current DC (blank) = ISO 4400 / DIN 43 650 mating plug (standard, IP 65) M00 = without mating DIN plug C = Kostal plug connection (IP 65) JT = Junior Timer radial plug connection (with protection diode, IP65) IT = Junior Timer axial plug connection (with protection diode, IP65) D = Deutsch plug connection DT04-P (IP 67/69K) mating plug not supplied DT = Deutsch plug connection DT04-P (with protection diode, IP 67/69K) S = AMP Superseal.5 (IP 67) / Metri-Pack 50 (IP 65) F = flying leads (500 mm) 8 Related data sheets Reference (Old no.) Description 50-P-000050 The form-tool hire programme 50-P-00040 (0-04.0) Cavity Type C040 50-P-0004 (0-04.) Line-mounting body, 0 Series 4-way info.el@bucherhydraulics.com www.bucherhydraulics.com 04 by Bucher Hydraulics, Inc., 333 Davis Road, Elgin, Illinois 603, USA www.commandcontrols.com All rights reserved. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: 430.300.-.305.30.30.300.300 50-P-300-EN-0/07.04 Series PDFC-0 5/5

EPRR-0 PROPORTIONAL PRESSURE REDUCING/ RELIEVING. DIRECT ACTING, SPOOL TYPE..78" [45,] 3 TORQUE: Steel = 55/60 Ft-Lb. [74/8 Nm] Aluminum = 35/40 Ft-Lb. [47/54 Nm] MANUAL OVERRIDE ( SCREW TYPE ) TYPE "L" COIL SEE PAGE 0-00. 4.40" [.8].75" [69,9].06"[7,0] HEX.83" [46,5] 3.50" [63,5] NOTES:. FOR ALUMINUM OR STEEL VALVE HOUSING CONFIGURATIONS SEE PAGE 0-03.. SOLENOIDS AVAILABLE WITH DIODES - CONSULT FACTORY. BASIC EPRR-0-X-XX-X-X-XXX X SIZE 0 = 7/8"-4UNF SEALS N = BUNA "N" V = VITON REGULATED PRESSURE 0 = 0 TO 00 PSI 03 = 0 TO 300 PSI 04 = 0 TO 400 PSI 05 = 0 TO 500 PSI 06 = 0 TO 600 PSI 07 = 0 TO 700 PSI 08 = 0 TO 800 PSI 0 = 0 TO 000 PSI M PORTS 0 0BX 03BX 06TX 08TX TERMINALS L =8GA. 4" LEADS T =SPADE TERM. B =BOLT TERM. G =DIN43650 W =WEATHER-PACK D =DEUTSCH-DT04-P M =METRI-PACK CONN. VOLTAGE AMPS D = VDC 3.00 4D = 4 VDC.50 ADJUSTMENT OPTIONS = MANUAL OVERRIDE = CARTRIDGE ONLY = G /4" BSPP = G 3/8" BSPP = SAE - #6 = SAE - #8 "A" = ALUM. HOUSING "S" = STEEL HOUSING REGULATED PRESSURE 000 800 600 400 00 PSI 0.30 AMPERAGE (AMPS) @ 4 VDC 0.5 0.30 0.45 0.60 0.75 0.90.05 0.60 0.90.0.50.80.0 AMPERAGE (AMPS) @ VDC.0.40 69,0 55, 4,4 7,6 3,8 BAR Reference: 50-P-00-EN-00/09.05

EPRR-0 DESCRIPTION This unit is a electro-hydraulic, proportional, screw in cartridge style, direct acting, spool type, pressure reducing/relieving flow pressure control valve. OPERATIONS ELECTRO-HYDRAULIC, PROPORTIONAL, PRESSURE REDUCING/RELIEVING VALVE. When the coil is de-energized, this valve allows no flow or pressure from port to and port is open to (tank) port 3. When the coil is energized, the spool in this valve shifts and allows flow and pressure between ports and and blocks port 3 (tank). When the coil is energized the armature moves a precision bias spring against the metering spool thus varying the pressure at port (Reg.) proportional to the curent input. When the current is increased to the coil the pressure will increase and when decreased it will decrease. IN THE EVENT OF POWER FAILURE THE VALVE WILL REDUCE REGULATED PRESSURE AT PORT TO ZERO. FEATURES AND BENEFITS Continuous-duty, very low heat rise & waterproof solenoid coil. Interchangeable solenoid coils & terminations options available. Hardened precision fitted spool & sleeve provides reliable, long life. Very efficient wet - armature solenoid core tube construction. All external carbon steel parts are plated for longer life against the elements. All cartridge valves are 00% functionally tested. Industry common cavity. Reference: 50-P-00-EN-00/09.05

EPRR-0 SPECIFICATIONS ELECTRO-HYDRAULIC, PROPORTIONAL, PRESSURE REDUCING/RELIEVING VALVE. OPERATING PRESSURE: 5,000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED PRESSURE: 0 to,000 PSI [0 to 69,0 Bar] See performance chart FLOW:.0 GPM (3.8 l/m) nominal INTERNAL LEAKAGE: 0 cu.in/min [64 cc/m] @ 5,000 PSI [350 Bar] VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with current control and a 50 Hz dither. POWER REQUIREMENTS: VDC, Operating current 0. to.4 AMPS. 4 VDC, Operating current 0. to. AMPS. SEAL KIT: SKN-03 Buna "N" SKV-03 Viton INSTALLATION: No restrictions. WEIGHT:.95 lb [.88 kg] cartridge with coil only. VALVE CAVITY: #C030, See Page 0-03.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-00-EN-00/09.05

Prop. Pressure-Reducing / Relieving Cartridge, Size SAE 08 Q max = 7.0 gpm [6 l/min], p max = 3400 psi [40 bar] Seated pilot, spool-type main stage Series EPRT-08 Description Series EPRT-08 proportional pressure-reducing / relieving valves are size SAE 08 / NG 5, high performance screw-in cartridges with a 3/4-6 UNF mounting thread. Using the leak-free seat-type pilot cartridge, the secondary pressure in port is dependent on the electrical control signal and it can be continuously varied and set at any desired level. In control mode, the connection opens until the pressure in port reaches the preset level. If the pressure rises above the preset level, the control spool opens the 3 connection until balance is attained. These pressurereducing / relieving cartridges function as full-flow pressure relief valves from port 3 as soon as the reduced pressure rises above the valve pressure setting. A high degree Compact construction for cavity types: C0830 and AM - 3/4-6 UNF Operated by a proportional solenoid 3 pressure ranges available Full-flow secondary pressure relief Internal pilot-oil drain Pilot stage protected from dirt by gap filter Excellent stability over the whole pressure and flow range All exposed parts with zinc-nickel plating High pressure wet-armature solenoids The slip-on coil can be rotated, and it can be replaced without opening the hydraulic envelope Various plug-connector systems and voltages are available Can be fitted in a line-mounting body of functional stability is reached even if the back pressure in the tank line fluctuates. Three pressure ranges are available in order to obtain precise pressure settings over the whole pressure range. These pressure-reducing / relieving cartridges are predominantly used in mobile and industrial applications for reducing a system pressure. All external parts of the cartridge are zinc-nickel plated to DIN 50 979 and are thus suitable for use in the harshest operating environments. The slip-on coils can be replaced without opening the hydraulic envelope and can be positioned at any angle through 360. If you intend to manufacture your own cavities or are designing a line-mounting installation, please refer to the section Related data sheets. Symbol 3 3 Technical data General characteristics Description, value, unit Designation proportional pressure-reducing / relieving cartridge Design seated pilot, spool-type main stage Mounting method screw-in cartridge 3/4-6 UNF Tightening torque 30 ft-lbs ± 0 % [40 Nm ± 0 %] Reference: 50-P-060-EN-0 Issue: 0.04 /6

General characteristics Size Description, value, unit size SAE 08 for cavity type C0830 NG 5 for cavity type AM Weight 0.93 lbs [0.4 kg] Mounting attitude unrestricted (preferably vertical, coil down) Ambient temperature range -3 F + F [-5 C +50 C] Hydraulic characteristics Maximum operating pressure - ports, - port 3 Description, value, unit 3400 psi [40 bar] 3000 psi [0 bar] ) Maximum flow rate 7 gpm [6 l/min] Nominal pressure ranges 500, 500, 3000 psi [00, 75, 0 bar] For further pressure ranges, please contact BUCHER Pilot-oil consumption 0.05 0.08 gpm [0, 0,3 l/min] Flow direction pressure reducing 3 pressure relieving Hydraulic fluid HL and HLP mineral oil to DIN 5 54; for other fluids, please contact BUCHER Hydraulic fluid temperature range -3 F +58 F [-5 C +70 C] Viscosity range Minimum fluid cleanliness Cleanliness class to ISO 4406 : 999 ATTENTION! ) To prevent any pressure surges, port 3 must be routed to tank with the least possible backpressure. 5 380 mm /s (cst), recommended 0...30 mm /s (cst) class 8/6/3 Electrical characteristics Supply voltage Supply voltage tolerance Control current Power consumption at max. control current Coil resistance R - cold value at 0 C - max. warm value Recommended PWM frequency (dither) Hysteresis with PWM Reversal error with PWM Sensitivity with PWM Reproducibility with PWM Switching time Description, value, unit V DC, 4 V DC 0 % V = 0 400 ma, 4 V = 0 750 ma max. 9 W V = 5.8 / 4 V = V = 8.6 / 4 V = 3 00 Hz 4 % I N 3 % I N % I N < % p N Pressure-reducing function: 38 45 ms (solenoid ON) 8 ms (solenoid OFF) Pressure-relief function: 4 5 ms (solenoid ON) 6 ms (solenoid OFF) The switching times are strongly influenced by flow rate, pressure, viscosity and the dwell period under pressure. /6 50-P-060-EN-0/0.04 Series EPRT-08

Electrical characteristics Relative duty cycle Protection class to ISO 0 653 / EN 60 59 Electrical connection Description, value, unit 00 % IP 65 / IP 67 / IP 69K, see Ordering code (with appropriate mating connector and proper fitting and sealing) 3-pin square plug to ISO 4400 / DIN 43 650 (standard) for other connectors, see Ordering code 4 Performance graphs measured with oil viscosity 33 mm /s (cst) p = f (I) Pressure adjustment characteristic p [psi] 3500 EL00.ai p [bar] [50] 800 00 400 p N 500 psi p N 3000 psi [00] [50] [00] 700 p N 500 psi [50] 0 0 00 00 300 400 500 600 700 I [ma] 00 400 600 800 000 00 400 I [ma] 50-P-060-EN-0/0.04 Series EPRT-08 3/6

p = f (Q) Pressure - Flow rate characteristic [p N = 3000 psi] p [psi] Q [l/min] 6,7 8,9 5,,4 7,6 3,8 0 3,8 7,6,4 5, 8,9,7 400 3500 800 00 400 700 p [bar] 6 [300] [50] [00] [50] [00] [50] Einsatzgrenze / Application limit (p min. / I = 0 ma) 0 EL_P00.ai 7 6 5 4 3 0 3 4 5 6 7 Q [gpm] p = f (Q) Pressure - Flow rate characteristic [p N = 500 psi] p [psi] Q [l/min] 6,7 8,9 5,,4 7,6 3,8 0 3,8 7,6,4 5, 8,9,7 3500 800 00 400 700 p [bar] 6 [50] [00] [50] [00] [50] Einsatzgrenze / Application limit (p min. / I = 0 ma) 0 EL_P006.ai 7 6 5 4 3 0 3 4 5 6 7 Q [gpm] p = f (Q) Pressure - Flow rate characteristic [p N = 500 psi] p [psi] Q [l/min] 6,7 8,9 5,,4 7,6 3,8 0 3,8 7,6,4 5, 8,9,7 800 500 00 900 600 300 0 EL_P003.ai 7 6 5 4 3 0 3 4 5 6 Q [gpm] p [bar] 6 [0] 7 [00] [80] [60] [40] [0] Einsatzgrenze / Application limit (p min. / I = 0 ma) 4/6 50-P-060-EN-0/0.04 Series EPRT-08

5 Dimensions & sectional view 7 5.60 [40,6] 6 3 4 3/4 6 UNF 3 5.9 [5] 5.00 [6,9] /6 M A= 30 ft lbs 0% [40 Nm 0%] 4.3 [0] M A= ft lbs [.7 Nm] ).4 [6,].4 [36] 6 Installation information IMPORTANT! To achieve the proportional pressure-reducing cartridge's maximum performance rating, fit the solenoid coil as shown (with the plug pins at the bottom). When fitting the cartridges, note the mounting attitude (preferably vertical, with coil down automatic air bleed) and use the specified tightening torque. No adjustments are necessary, since the cartridges are set in the factory. ATTENTION! Only qualified personnel with mechanical skills may carry out any maintenance work. Generally, the only work that should ever be undertaken is to check, and possibly replace, the seals. When changing seals, oil or grease the new seals thoroughly before fitting them. Seal kit NBR no. SKN-083--S ) Item Qty. Description O-ring 6,00 x,00 FKM mm O-ring 8,00 x,00 FKM mm 3 O-ring no. 908 0,644 x 0,087 N70 Inch 4 O-ring no. 04 0,489 x 0,070 N70 Inch 5 O-ring no. 03 0,46 x 0,070 N70 Inch 6 Backup ring 0,4 x 0,057 x 0,039 FI075 7 Backup ring 0,370 x 0,057 x 0,039 FI075 Inch Inch IMPORTANT! ) Seal kit with FKM (Viton) seals, no. SKV-083--S ) vent screw to vent valve when mounted coil up screw torqued hand tight. 50-P-060-EN-0/0.04 Series EPRT-08 5/6

7 Ordering code Ex. EPRT - 08 - N - 30-0 - 4 D _ EPRT = prop. pressure-reducing / relieving valve, two stage 08 = nominal size SAE 08 N = NBR (Nitrile) seals (standard) V = FKM (Viton) seals (special seals - please contact BUCHER) 30 = Pressure option 3000 psi 5 = Pressure option 500 psi 5 = Pressure option 500 psi 0 = cartridge only 0BA = line-mounting body G/4 BSPP aluminum 0BS = line-mounting body G/4 BSPP steel 03BA = line-mounting body G3/8 BSPP aluminum 03BS = line-mounting body G3/8 BSPP steel 06TA = line-mounting body SAE-6 aluminum 06TS = line-mounting body SAE-6 steel 08TA = line-mounting body SAE-8 aluminum 08TS = line-mounting body SAE-8 steel... = voltage e.g. 4 (4 V) D = current DC (blank) = ISO 4400 / DIN 43 650 mating plug (standard, IP 65) M00 = without mating DIN plug C = Kostal plug connection (IP 65) JT = Junior Timer radial plug connection (with protection diode, IP65) IT = Junior Timer axial plug connection (with protection diode, IP65) D = Deutsch plug connection DT04-P (IP 67/69K) mating plug not supplied DT = Deutsch plug connection DT04-P (with protection diode, IP 67/69K) S = AMP Superseal.5 (IP 67) / Metri-Pack 50 (IP 65) F = flying leads (500 mm) 8 Related data sheets Reference (Old no.) Description 50-P-000050 The form-tool loan program 50-P-00030 (0-03.0) Cavity type C0830 400-P-0408 Cavity type AM 400-P-00 (W-.4) Coils for screw-in cartridge valves 400-P-500 Amplifier unit for proportional valves (-channel) PBS - 3A 400-P-50 (P-3) Amplifier card, -channel for valves with one solenoid, type SAN-535 50-P-0003 (0-03.) Line-mounting body, 8 Series -3-way 400-P-70 (G-4.0) Line-mounting body, type GAMA (G 3/8 ) info.el@bucherhydraulics.com www.bucherhydraulics.com 04 by Bucher Hydraulics, Inc., 333 Davis Road, Elgin, Illinois 603, USA www.commandcontrols.com All rights reserved. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: 430.300.305.305.30.30 6/6 50-P-060-EN-0/0.04 Series EPRT-08

EPRS-0 PROPORTIONAL PRESSURE REDUCING/ RELIEVING. PILOT OPERATED, SLIDING SPOOL 3.78" [45,] MANUAL OVERRIDE ( SCREW TYPE ) TYPE "L" COIL SEE PAGE 0-00. 5.0" [9,5].06" [7,0] HEX.75" [69,9].85" [47,0] 3.50" [63,5] TORQUE: Steel = 55/60 Ft-Lb. [74/8 Nm] Aluminum = 35/40 Ft-Lb. [47/54 Nm] BASIC EPRS-0-X-XX-X-X-XXX X SIZE 0 = 7/8"-4UNF SEALS N = BUNA "N" V = VITON REGULATED PRESSURE 5 = 50 TO 500 PSI 30 = 50 TO 3000 PSI 50 = 50 TO 5000 PSI PORTS 0 0BX 06BX 06TX 08TX TERMINALS L =8GA. 4" LEADS T =SPADE TERM. B =BOLT TERM. G =DIN43650 W =WEATHER-PACK D =DEUTSCH-DT04-P M =METRI-PACK CONN. VOLTAGE AMPS D = VDC 3.00 4D = 4 VDC.50 ADJUSTMENT OPTIONS M = MANUAL OVERRIDE = CARTRIDGE ONLY = G /4" BSPP = G 3/8" BSPP = SAE - #6 = SAE - #8 "A" = ALUM. HOUSING "S" = STEEL HOUSING REGULATED PRESSURE 5000 4000 3000 000 000 PSI 0.5 0.30 AMPERAGE (AMPS) @ 4 VDC 0.30 0.60 0.45 0.90 0.60 0.75 0.90.0.50.80.05.0 AMPERAGE (AMPS) @ VDC.0.40 345 76 07 38 69 BAR Reference: 50-P-00-EN-00/09.05

EPRS-0 DESCRIPTION This unit is a electro-hydraulic, proportional, screw in cartridge style, pilot operated, sliding spool type, high pressure reducing and relieving control valve. OPERATIONS ELECTRO-HYDRAULIC, PROPORTIONAL, PRESSURE REDUCING/RELIEVING VALVE. When the coil is de-energized, this valve will allow flow from port to port until pressure in port exceeds the spring bias then the spool will shift and block flow from port to port relieving pressure to port 3. When the coil is energized, the armature moves a precision bias spring against the pilot orifice thus varying the pressure at port (reg.) proportional to the current input regardless of the pressure at port. Excess pressure at port is relieved to port 3. When the coil current is increased the pressure will increase and when decreased it will decrease. IN THE EVENT OF POWER FAILURE THE VALVE WILL REDUCE REGULATED PRESSURE AT PORT TO 50 PSI. FEATURES AND BENEFITS Continuous-duty, very low heat rise & waterproof solenoid coil. Pressure in tank port (3) will add to the bias spring setting, and is limited to 000 PSI. Interchangeable solenoid coils & terminations options available. Hardened precision fitted spool & sleeve provides reliable, long life. A unique self aligning (floating) cage provides very low hysteresis and reliable operation. Very efficient wet - armature solenoid core tube construction. All external carbon steel parts are plated for longer life against the elements. All cartridge valves are 00% functionally tested. Industry common cavity. Reference: 50-P-00-EN-00/09.05

EPRS-0 SPECIFICATIONS ELECTRO-HYDRAULIC, PROPORTIONAL, PRESSURE REDUCING/RELIEVING VALVE. OPERATING PRESSURE: 5,000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED PRESSURE: 50 to 5000 PSI [3,5 to 345] See performance chart. FLOW:.0 GPM [46,0 L/M] nominal. INTERNAL PILOT FLOW: 0 cu.in/min [0,50 l/m] @ 5,000 PSI [350 Bar] VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with current control and a 50 Hz dither. POWER REQUIREMENTS: VDC, Operating current 0. to.4 AMPS. 4 VDC, Operating current 0. to. AMPS. SEAL KIT: SKN-03 Buna "N" SKV-03 Viton INSTALLATION: No restrictions. WEIGHT:.95 lb [.88 kg] cartridge with coil only. VALVE CAVITY: #C030, See Page 0-03.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-00-EN-00/09.05

EPRS- PROPORTIONAL PRESSURE REDUCING/ RELIEVING PILOT OPERATED, SLIDING SPOOL 3 TORQUE: Steel = 70/75 Ft-Lb. [95/0 Nm] Aluminum = 55/60 Ft-Lb. [74/8 Nm].78" [45,] MANUAL OVERRIDE ( SCREW TYPE ) TYPE "L" COIL SEE PAGE 0-00. 5.7" [3,3] HEX 4.00" [0,6].3" [33,4].66" [67,6] 3 3.50" [88,9] NOTES:. FOR ALUMINUM OR STEEL VALVE HOUSING CONFIGURATIONS SEE PAGE 0-033.. SOLENOIDS AVAILABLE WITH DIODES - CONSULT FACTORY. BASIC EPRS--X-XX-X-X-XXX X SIZE =.06"-UNF SEALS N = BUNA "N" V = VITON REGULATED PRESSURE 5 = 50 TO 500 PSI 30 = 50 TO 3000 PSI 50 = 50 TO 5000 PSI TERMINALS L =8GA. 4" LEADS T =SPADE TERM. B =BOLT TERM. G =DIN43650 W =WEATHER-PACK D =DEUTSCH-DT04-P M =METRI-PACK CONN. VOLTAGE AMPS D = VDC 3.00 4D = 4 VDC.50 ADJUSTMENT OPTIONS M = MANUAL OVERRIDE PORTS 0 = CARTRIDGE 4BX = G /" BSPP 6BX = G 3/4" BSPP 0TX = SAE - #0 TX = SAE - # "A" - ALUM. HOUSING "S" - STEEL HOUSING REGULATED PRESSURE 5000 4000 3000 000 000 PSI AMPERAGE (AMPS) @ 4 VDC 0.5 0.30 0.45 0.60 0.75 0.90.05.0 0.30 0.60 0.90.0.50.80.0.40 AMPERAGE (AMPS) @ VDC 345 76 07 38 69 BAR Reference: 50-P-030-EN-00/09.05

EPRS- DESCRIPTION This unit is a electro-hydraulic, proportional, screw in cartridge style, pilot operated, sliding spool type, high pressure reducing and relieving control valve. OPERATIONS ELECTRO-HYDRAULIC, PROPORTIONAL, PRESSURE REDUCING/RELIEVING VALVE. When the coil is de-energized, this valve will allow flow from port to port until pressure in port exceeds the spring bias then the spool will shift and block flow from port to port relieving pressure to port 3. When the coil is energized, the armature moves a precision bias spring against the pilot orifice thus varying the pressure at port (reg.) proportional to the current input regardless of the pressure at port. Excess pressure at port is relieved to port 3. When the coil current is increased the pressure will increase and when decreased it will decrease. IN THE EVENT OF POWER FAILURE THE VALVE WILL REDUCE REGULATED PRESSURE AT PORT TO 50 PSI. FEATURES AND BENEFITS Continuous-duty, very low heat rise & waterproof solenoid coil. Pressure in tank port (3) will add to the bias spring setting, and is limited to 000 PSI. Interchangeable solenoid coils & terminations options available. Hardened precision fitted spool & sleeve provides reliable, long life. A unique self aligning (floating) cage provides very low hysteresis and reliable operation. Very efficient wet-armature solenoid core tube construction. All external carbon steel parts are plated for longer life against the elements. All cartridge valves are 00% functionally tested. Reference: 50-P-030-EN-00/09.05

EPRS- SPECIFICATIONS ELECTRO-HYDRAULIC, PROPORTIONAL, PRESSURE REDUCING/RELIEVING VALVE. OPERATING PRESSURE: 5,000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED PRESSURE: 50 to 5000 PSI [3,5 to 345] See performance chart. FLOW: 4.0 GPM [9,0 L/M] nominal. INTERNAL PILOT FLOW: 60 cu.in/min [,0 l/m] @ 5,000 PSI [350 Bar] VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with current control and a 50 Hz dither. POWER REQUIREMENTS: VDC, Operating current 0. to.4 AMPS. 4 VDC, Operating current 0. to. AMPS. SEAL KIT: SKN-3 Buna "N" SKV-3 Viton INSTALLATION: No restrictions. WEIGHT:.3 lb [, kg] cartridge with coil only. VALVE CAVITY: #C30, See Page 0-033.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-030-EN-00/09.05

ERVP-0 PROPORTIONAL PRESSURE RELIEF VALVE. PILOT OPERATED, SLIDING SPOOL TYPE. Pat.#5,546,980 TORQUE: Steel = 55/60 Ft-Lb. [74/8 Nm] Aluminum = 35/40 Ft-Lb. [47/54 Nm].78" [45,] MANUAL OVERRIDE ( SCREW TYPE ) TYPE "L" COIL SEE PAGE 0-00. 5.0" [9,5].00" [50,8].06" [7,0] HEX.8" [3,5].00" [50,8] NOTES:. FOR ALUMINUM OR STEEL VALVE HOUSING CONFIGURATIONS SEE PAGE 0-0.. SOLENOIDS AVAILABLE WITH DIODES - CONSULT FACTORY. BASIC ERVP-0-X-XX-X-X-XXX X SIZE 0 = 7/8"-4UNF SEALS N = BUNA "N" V = VITON REGULATED PRESSURE 5 = 50 TO 500 PSI 30 = 50 TO 3000 PSI 50 = 50 TO 5000 PSI PORTS 0 0BX 06BX 06TX 08TX TERMINALS L =8GA. 4" LEADS T =SPADE TERM. B =BOLT TERM. G =DIN43650 W =WEATHER-PACK D =DEUTSCH-DT04-P M =METRI-PACK CONN. VOLTAGE AMPS D = VDC 3.00 4D = 4 VDC.50 ADJUSTMENT OPTIONS M = MANUAL OVERRIDE = CARTRIDGE ONLY = G /4" BSPP = G 3/8" BSPP = SAE - #6 = SAE - #8 "A" = ALUM. HOUSING "S" = STEEL HOUSING REGULATED PRESSURE 5000 4000 3000 000 000 PSI AMPERAGE (AMPS) @ 4 VDC 0.5 0.30 0.45 0.60 0.75 0.90.05.0 0.30 0.60 0.90.0.50.80.0.40 AMPERAGE (AMPS) @ VDC 350 76 07 38 69 BAR Reference: 50-P-030-EN-00/09.05

ERVP-0 DESCRIPTION This unit is a electro-hydraulic, proportional, screw in cartridge style, pilot operated, sliding spool type, high pressure relief valve. OPERATIONS ELECTRO-HYDRAULIC, PROPORTIONAL, When the coil is de-energized, this valve allows flow and pressure from port to port if pressure exceeds the spring bias (50 psi). When the coil is energized the armature moves a precision bias spring against the pilot orifice thus varying the pressure setting at port proportional to the current input. When the current is increased to the coil the relief pressure will increase and when decreased it will decrease. IN THE EVENT OF POWER FAILURE THE VALVE RELIEF PRESSURE SETTING AT PORT WILL BE THE SPRING BIAS. FEATURES AND BENEFITS PRESSURE RELIEF VALVE. Continuous-duty, very low heat rise & waterproof solenoid coil. Pressure in tank port () will add to the bias spring setting, and is limited to 000 PSI. Interchangeable solenoid coils & terminations options available. Hardened precision fitted spool & sleeve provides reliable, long life. A unique self aligning (floating) cage provides very low hysteresis and reliable operation. Very efficient wet - armature solenoid core tube construction. All external carbon steel parts are plated for longer life against the elements. All cartridge valves are 00% functionally tested. Industry common cavity. Reference: 50-P-030-EN-00/09.05

ERVP-0 ELECTRO-HYDRAULIC, PROPORTIONAL, PRESSURE RELIEF VALVE. SPECIFICATIONS OPERATING PRESSURE: 5000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED PRESSURE: 50 to 5000 PSI [3,5 to 345] See performance chart. FLOW: 5.0 GPM [95,0 L/M] nominal. INTERNAL PILOT FLOW: 60 cu.in/min [,0 l/m] @ 3000 PSI [0 Bar] VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with current control and a 50 Hz dither. POWER REQUIREMENTS: VDC, Operating current 0. to.4 AMPS. 4 VDC, Operating current 0. to. AMPS. SEAL KIT: SKN-0 Buna "N" SKV-0 Viton INSTALLATION: No restrictions. WEIGHT:.95 lb [.88 kg] cartridge with coil only. VALVE CAVITY: #C00, See Page 0-0.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-030-EN-00/09.05

ERVP- PROPORTIONAL PRESSURE RELIEF VALVE. PILOT OPERATED, SLIDING SPOOL TYPE. Pat.#5,546,980.78" [45,] TORQUE: Steel = 70/75 Ft-Lb. [95/0 Nm] Aluminum = 55/60 Ft-Lb. [74/8 Nm] MANUAL OVERRIDE ( SCREW TYPE ) TYPE "L" COIL SEE PAGE 0-00. 5.7" [3,3] HEX.75" [69,9].3" [33,4].75" [44,5].75" [69,9] NOTES:. FOR ALUMINUM OR STEEL VALVE HOUSING CONFIGURATIONS SEE PAGE 0-03.. SOLENOIDS AVAILABLE WITH DIODES - CONSULT FACTORY. BASIC ERVP--X-XX-X-X-XXX X SIZE =.06"-UNF SEALS N = BUNA "N" V = VITON REGULATED PRESSURE 5 = 50 TO 500 PSI 30 = 50 TO 3000 PSI 50 = 50 TO 5000 PSI TERMINALS L =8GA. 4" LEADS T =SPADE TERM. B =BOLT TERM. G =DIN43650 W =WEATHER-PACK D =DEUTSCH-DT04-P M =METRI-PACK CONN. VOLTAGE AMPS D = VDC 3.00 4D = 4 VDC.50 ADJUSTMENT OPTIONS M = MANUAL OVERRIDE PORTS 0 = CARTRIDGE 4BX = G /" BSPP 6BX = G 3/4" BSPP 0TX = SAE - #0 TX = SAE - # "A" - ALUM. HOUSING "S" - STEEL HOUSING REGULATED PRESSURE 5000 4000 3000 000 000 PSI AMPERAGE (AMPS) @ 4 VDC 0.5 0.30 0.45 0.60 0.75 0.90.05.0 0.30 0.60 0.90.0.50.80.0.40 AMPERAGE (AMPS) @ VDC 350 76 07 38 69 BAR Reference: 50-P-0330-EN-00/09.05

ERVP- DESCRIPTION This unit is a electro-hydraulic, proportional, screw in cartridge style, pilot operated, sliding spool type, high pressure relief valve. OPERATIONS ELECTRO-HYDRAULIC, PROPORTIONAL, FEATURES AND BENEFITS PRESSURE RELIEF VALVE. When the coil is de-energized, this valve allows flow and pressure from port to port if pressure exceeds the spring bias (50 psi). When the coil is energized the armature moves a precision bias spring against the pilot orifice thus varying the pressure setting at port proportional to the current input. When the current is increased to the coil the relief pressure will increase and when decreased it will decrease. IN THE EVENT OF POWER FAILURE THE VALVE RELIEF PRESSURE SETTING AT PORT WILL BE THE SPRING BIAS. Continuous-duty, very low heat rise & waterproof solenoid coil. Pressure in tank port () will add to the bias spring setting, and is limited to 000 PSI. Interchangeable solenoid coils & terminations options available. Hardened precision fitted spool & sleeve provides reliable, long life. A unique self aligning (floating) cage provides very low hysteresis and reliable operation. Very efficient wet - armature solenoid core tube construction. All external carbon steel parts are plated for longer life against the elements. All cartridge valves are 00% functionally tested. Reference: 50-P-0330-EN-00/09.05

ERVP- SPECIFICATIONS ELECTRO-HYDRAULIC, PROPORTIONAL, PRESSURE RELIEF VALVE. OPERATING PRESSURE: 5000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED PRESSURE: 50 to 5000 PSI [3,5 to 345] See performance chart. FLOW: 60.0 GPM [7,0 L/M] nominal. INTERNAL PILOT FLOW: 60 cu.in/min [,0 l/m] @ 3000 PSI [0 Bar] VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with current control and a 50 Hz dither. POWER REQUIREMENTS: VDC, Operating current 0. to.4 AMPS. 4 VDC, Operating current 0. to. AMPS. SEAL KIT: SKN- Buna "N" SKV- Viton INSTALLATION: No restrictions. WEIGHT:.5 lb [, kg] cartridge with coil only. VALVE CAVITY: #C0, See Page 0-03.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-0330-EN-00/09.05

ERVD-0 PROPORTIONAL PRESSURE RELIEF VALVE. DIRECT ACTING, LOW FLOW, POPPET TYPE. Pat.#5,546,980 TORQUE: Steel = 55/60 Ft-Lb. [74/8 Nm] Aluminum = 35/40 Ft-Lb. [47/54 Nm].78" [45,] MANUAL OVERRIDE ( SCREW TYPE ) TYPE "L" COIL SEE PAGE 0-00. 5.0" [9,5].00" [50,8].06" [7,0] HEX.8" [3,5].00" [50,8] NOTES:. FOR ALUMINUM OR STEEL VALVE HOUSING CONFIGURATIONS SEE PAGE 0-0.. SOLENOIDS AVAILABLE WITH DIODES - CONSULT FACTORY. BASIC ERVD-0-X-XX-X-X-XXX X SIZE 0 = 7/8"-4UNF SEALS N = BUNA "N" V = VITON REGULATED PRESSURE 5 = 0 TO 500 PSI 30 = 0 TO 3000 PSI 50 = 0 TO 5000 PSI PORTS 0 0BX 06BX 06TX 08TX TERMINALS L =8GA. 4" LEADS T =SPADE TERM. B =BOLT TERM. G =DIN43650 W =WEATHER-PACK D =DEUTSCH-DT04-P M =METRI-PACK CONN. VOLTAGE AMPS D = VDC 3.00 4D = 4 VDC.50 ADJUSTMENT OPTIONS M = MANUAL OVERRIDE = CARTRIDGE ONLY = G /4" BSPP = G 3/8" BSPP = SAE - #6 = SAE - #8 "A" = ALUM. HOUSING "S" = STEEL HOUSING REGULATED PRESSURE 5000 4000 3000 000 000 PSI AMPERAGE (AMPS) @ 4 VDC 0.5 0.30 0.45 0.60 0.75 0.90.05.0 0.30 0.60 0.90.0.50.80.0 AMPERAGE (AMPS) @ VDC.40 345 76 07 38 69 BAR Reference: 50-P-040-EN-00/09.05

ERVD-0 DESCRIPTION This unit is a electro-hydraulic, proportional, screw in cartridge style, direct acting, low flow, poppet type, high pressure relief valve. OPERATIONS ELECTRO-HYDRAULIC, PROPORTIONAL, When the coil is de-energized, this valve allows flow and pressure from port to port (tank). When the coil is energized the armature moves a precision bias spring against the metering poppet thus varying the pressure at port proportional to the curent input. When the current is increased to the coil the pressure will increase and when decreased it will decrease. IN THE EVENT OF POWER FAILURE THE VALVE WILL REDUCE REGULATED PRESSURE AT PORT TO 0 PSI. FEATURES AND BENEFITS PRESSURE RELIEF VALVE. Continuous-duty, very low heat rise & waterproof solenoid coil. Pressure in tank port () will add to the bias spring setting, and is limited to 000 PSI. Interchangeable solenoid coils & terminations options available. Hardened precision poppet & pilot seat provides reliable, long life. A unique self aligning (floating) cage provides very low hysteresis and reliable operation. Very efficient wet - armature solenoid core tube construction. All external carbon steel parts are plated for longer life against the elements. All cartridge valves are 00% functionally tested. Industry common cavity. Reference: 50-P-040-EN-00/09.05

ERVD-0 SPECIFICATIONS ELECTRO-HYDRAULIC, PROPORTIONAL, PRESSURE RELIEF VALVE. OPERATING PRESSURE: 5000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED PRESSURE: 0 to 5000 PSI [0 to 350] See performance chart. FLOW:.0 GPM [3.8 L/M] nominal. VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with 4 VDC, Operating current 0. to. AMPS. POWER REQUIREMENTS: VDC, Operating current 0. to.4 AMPS. current control and a 50 Hz dither. SEAL KIT: SKN-0 Buna "N" SKV-0 Viton INSTALLATION: No restrictions. WEIGHT:.95 lb [.88 kg] cartridge with coil only. VALVE CAVITY: #C00, See Page 0-0.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-040-EN-00/09.05

EPFI-0 ELECTRO-HYDRAULIC, PROPORTIONAL, PRESSURE COMP, FLOW CONTROL VALVE. TORQUE: Steel = 55/60 Ft-Lb. [74/8 Nm] Aluminum = 35/40 Ft-Lb. [47/54 Nm].78" [45,] MANUAL OVERRIDE ( SCREW TYPE ) TYPE "L" COIL SEE PAGE 0-00. 5.03" [7,7].00" [50,8] NOTES:.00" [50,8].3" [33,3]. FOR ALUMINUM OR STEEL VALVE HOUSING CONFIGURATIONS SEE PAGE 0-0.. SOLENOIDS AVAILABLE WITH DIODES - CONSULT FACTORY..06" [7.0] HEX BASIC EPFI-0-X-X-XX-X-X-XXX X SIZE 0 = 7/8"-4UNF SEALS N = BUNA "N" V = VITON STYLE C = NORMALLY CLOSED O = NORMALLY OPEN REGULATED FLOW 04 = 0 TO 4.0 GPM 08 = 0 TO 8.0 GPM PORTS 0 0BX 06BX 06TX 08TX TERMINALS L =8GA. 4" LEADS T =SPADE TERM. B =BOLT TERM. G =DIN43650 W =WEATHER-PACK D =DEUTSCH-DT04-P M =METRI-PACK CONN. VOLTAGE AMPS D = VDC 3.00 4D = 4 VDC.50 ADJUSTMENT OPTIONS 0 = NONE M = MANUAL OVERRIDE = CARTRIDGE ONLY = G /4" BSPP = G 3/8" BSPP = SAE - #6 = SAE - #8 "A" = ALUM. HOUSING "S" = STEEL HOUSING REGULATED FLOW 8 7 6 5 4 3 GPM AMPERAGE (AMPS) @ 4 VDC 0.5 0.30 0.45 0.60 0.75 0.90.05.0 NORMALLY NORMALLY OPEN CLOSED 0.3 0.6 0.9..5.8..4 AMPERAGE (AMPS) @ VDC 30.3 6.5.7 8.9 5..4 7.6 3.8 L/M Reference: 50-P-00-EN-00/09.05

EPFI-0 PROPORTIONAL, PRESSURE COMPENSATED, FLOW CONTROL VALVE. DESCRIPTION This valve is a cartridge style, electro-hydraulic, proportional, in-line (RESTRICTIVE) type, pressure compensated, hydraulic flow control. Regulated flow 8.0 GPM [30, L/M] max. is proportional to the current input regardless of load or system pressure. OPERATIONS This unit is a direct acting (NO PILOT FLOW), electro hydraulic, proportional, pressure compensated flow control valve. When the coil is energized the ar- mature moves the metering orifice open against a precision bias spring varying the flow. A pressure compensatory spool (HYDROSTAT) modulates the flow at 00 PSI/6,9 Bar delta "P" providing the valve with a constant regulated flow regardless of load or system pressure. For the normally closed product when the current is increased to the coil the flow will increase. For the normally open product as the current is increased to the coil the flow will decrease. IN THE EVENT OF POWER FAILURE THE NORMALLY CLOSED VALVE WILL CLOSE AND THE NORMALLY OPEN VALVE WILL OPEN. FEATURES AND BENEFITS Continuous-duty, very low heat rise & waterproof solenoid coil. Interchangeable solenoid coils & termination options available. Hardened precision fitted spool & sleeve provides reliable, long life. Very efficient wet - armature solenoid core tube construction. All external carbon steel parts are plated for longer life against the elements. All cartridge valves are 00% functionally tested. Reference: 50-P-00-EN-00/09.05

EPFI-0 SPECIFICATIONS PROPORTIONAL, PRESSURE COMPENSATED, FLOW CONTROL VALVE. OPERATING PRESSURE: 5,000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED FLOW: 8.0 GPM [30, l/m] Max. See performance chart. INTERNAL LEAKAGE: 0/40 in³/min [38/655 cc/m]@3/5k PSI [75/350 Bar] VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with current control and a 50 Hz dither. POWER REQUIREMENTS: VDC, Operating current 0. to. AMPS. 4 VDC, Operating current 0. to. AMPS. SEAL KIT: SKN-0 Buna "N" SKV-0 Viton INSTALLATION: No restrictions. WEIGHT:.9 lb [0,86 kg] cartridge with coil only. VALVE CAVITY: #C00, See Page 0-0.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-00-EN-00/09.05

EPFI- ELECTRO-HYDRAULIC, PROPORTIONAL, PRESSURE COMP, FLOW CONTROL VALVE..78" [45,] MANUAL OVERRIDE ( SCREW TYPE ) TYPE "L" COIL SEE PAGE 0-00. 5.9" [50,4].75" [69,9].75" [44,4].3" [33,3] HEX. TORQUE to 80/90 Ft-Lb. [00/0 N-m]..75" [69,9] NOTES:. FOR ALUMINUM OR STEEL VALVE HOUSING CONFIGURATIONS SEE PAGE 0-03.. SOLENOIDS AVAILABLE WITH DIODES - CONSULT FACTORY. BASIC EPFI--N-X-XX-X-X-XXX X SIZE =.06"-UNF SEALS N = BUNA "N" V = VITON TYPE C = NORMALLY CLOSED O = NORMALLY OPEN TERMINALS L=8GA. 4" LEADS T=SPADE TERM. B=BOLT TERM. G=DIN43650 W=WEATHER-PACK D=DEUTSCH-DT04-P M=METRI-PACK CONN. VOLTAGE AMPS D = VDC 3.00 4D = 4 VDC.50 ADJUSTMENT OPTIONS 0 = NONE M = MANUAL OVERRIDE REGULATED FLOW PORTS 05 = 0 TO 5.0 GPM 0 = CARTRIDGE 0 = 0 TO 0.0 GPM 4BX = G /" BSPP 5 = 0 TO 5.0 GPM 6BX = G 3/4" BSPP 0TX = SAE - #0 TX = SAE - # "A" - ALUM. HOUSING "S" - STEEL HOUSING REGULATED FLOW 6 4 0 8 6 4 GPM AMPERAGE (AMPS) @ 4 VDC 0.5 0.30 0.45 0.60 0.75 0.90.05.0 NORMALLY OPEN NORMALLY CLOSED 0.3 0.6 0.9..5.8..4 AMPERAGE (AMPS) @ VDC 60.6 53.0 45.4 37.9 30.3.7 5. 7.6 L/M Reference: 50-P-030-EN-00/09.05

EPFI- DESCRIPTION This valve is a cartridge style, electro-hydraulic, proportional, in-line (RESTRICTIVE) type, pressure compensated, hydraulic flow control. Regulated flow 5.0 GPM [56,8 l/m] max. is proportional to the current input regardless of load or system pressure. OPERATIONS PROPORTIONAL, PRESSURE COMPENSATED, FLOW CONTROL VALVE. This unit is a direct acting (NO PILOT FLOW), electro hydraulic, proportional, pressure compensated flow control valve. When the coil is energized, the ar- mature moves the metering orifice open against a precision bias spring varying the flow. A pressure compensator spool (HYDROSTAT) modulates the flow at 00 PSI/6,9 Bar delta "P" providing the valve with a constant regulated flow regardless of load or system pressure. For the normally closed product when the current is increased to the coil, the flow will increase. For the normally open product as the current is increased to the coil the flow will decrease. IN THE EVENT OF POWER FAILURE, THE NORMALLY CLOSED VALVE WILL CLOSE AND THE NORMALLY OPEN VALVE WILL OPEN. FEATURES AND BENEFITS Continuous-duty, very low heat rise & waterproof solenoid coil. Interchangeable solenoid coils & termination options available. Hardened precision fitted spool & sleeve provides reliable, long life. Very efficient wet - armature solenoid core tube construction. All external carbon steel parts are plated for longer life against the elements. All cartridge valves are 00% functionally tested. Reference: 50-P-030-EN-00/09.05

EPFI- SPECIFICATIONS PROPORTIONAL, PRESSURE COMPENSATED, FLOW CONTROL VALVE. OPERATING PRESSURE: 5,000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED FLOW: 5.0 GPM [56,8 l/m] Max. See performance chart. INTERNAL LEAKAGE: 0/40 in³/min [38/655 cc/m] @ 3/5K PSI [75/350 Bar] VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with current control and a 50 Hz dither. POWER REQUIREMENTS: VDC, Operating current 0. to. AMPS. 4 VDC, Operating current 0. to. AMPS. SEAL KIT: SKN- Buna "N" SKV- Viton INSTALLATION: No restrictions. WEIGHT:.7 lb [,03 kg] cartridge with coil only. VALVE CAVITY: #C0, See Page 0-03.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-030-EN-00/09.05

EPFC-6 ELECTRO-HYDRAULIC, PROPORTIONAL, IN-LINE, PRESSURE COMP, FLOW CONTROL VALVE..78" [45,] MANUAL OVERRIDE ( SCREW TYPE ) TYPE "L" COIL SEE PAGE 0-00. 5.60" [4,].50" [38,] Hex. 3.00" [76,].80" [45,7] BASIC SIZE 6 =.3"-UNF SEALS N = BUNA "N" V = VITON REGULATED FLOW 05 = 0 TO 5.0 GPM 0 = 0 TO 0.0 GPM 5 = 0 TO 5.0 GPM 0 = 0 TO 0.0 GPM 3.00" [76,] EPFC-6-X-XX-X-X-XXX X PORTS 0 06BX 08BX TX 6TX TERMINALS L =8GA. 4" LEADS T =SPADE TERM. B =BOLT TERM. G =DIN43650 W =WEATHER-PACK D =DEUTSCH-DT04-P M =METRI-PACK CONN. VOLTAGE AMPS D = VDC 3.00 4D = 4 VDC.50 ADJUSTMENT OPTIONS M = MANUAL OVERRIDE = CARTRIDGE ONLY = G 3/4" BSPP = G " BSPP = SAE - # = SAE - #6 "A" = ALUM. HOUSING "S" = STEEL HOUSING REGULATED FLOW 5 0 5 0 5 GPM AMPERAGE (AMPS) @ 4 VDC 0.5 0.30 0.45 0.60 0.75 0.90.05.0 0.30 0.60 0.90.0.50.80.0.40 AMPERAGE (AMPS) @ VDC TORQUE: Steel = 95/00 Ft-Lb. [9/36 Nm] Aluminum = 70/75 Ft-Lb. [95/0 Nm] 95 76 57 38 9 L/M Reference: 50-P-040-EN-00/09.05

EPFC-6 PROPORTIONAL, IN-LINE TYPE, FLOW CONTROL VALVE. DESCRIPTION This valve is a cartridge style, electro-hydraulic, proportional, in-line (RESTRICTIVE) type, pressure compensated, hydraulic flow control. Regulated flow 0.0 GPM [76,0 L/M] max. is proportional to the current input regardless of load or system pressure. OPERATIONS This unit is a direct acting (NO PILOT FLOW), electro hydraulic, pro- portional, pressure compensated, flow control valve. When the coil is energized the armature moves the metering orifice open against a pre- cision bias spring varying the flow. A pressure compensator spool (HYDROSTAT) modulates the flow at 00 PSI/6,9 Bar delta "P" providing the valve with a constant regulated flow regardless of load or system pressure. When current is increased to the coil the flow will increase, as the current is decreased the flow will decrease proportionally. IN THE EVENT OF POWER FAILURE THE VALVE WILL CLOSE. FEATURES AND BENEFITS Continuous-duty, very low heat rise & waterproof solenoid coil. Interchangeable solenoid coils & terminations options available. Hardened precision fitted spool & sleeve provides reliable, long life. Very efficient wet - armature solenoid core tube construction. All external carbon steel parts are plated for longer life against the elements. All cartridge valves are 00% functionally tested. Industry common cavity. Reference: 50-P-040-EN-00/09.05

EPFC-6 PROPORTIONAL, IN-LINE TYPE, FLOW CONTROL VALVE. SPECIFICATIONS OPERATING PRESSURE: 5,000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED FLOW: 0.0 GPM [76,0 l/m] Max. See performance chart. INTERNAL LEAKAGE: 0 cu.in/min [330 cc/m] @ 5,000 PSI [350 Bar] VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with current control and a 50 Hz dither. POWER REQUIREMENTS: VDC, Operating current 0. to. AMPS. 4 VDC, Operating current 0. to. AMPS. SEAL KIT: SKN-6 Buna "N" SKV-6 Viton INSTALLATION: No restrictions. WEIGHT:.58 lb [,7 kg] cartridge with coil only. VALVE CAVITY: #C60, See Page 0-04.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-040-EN-00/09.05

EPFB-0 ELECTRO-HYDRAULIC, PROPORTIONAL, PRIORITY, PRESSURE COMP, FLOW CONTROL VALVE. 3.78" [45,] MANUAL OVERRIDE ( SCREW TYPE ) TYPE "L" COIL SEE PAGE 0-00. 5.03" [7,8].06" [7,0] HEX.75" [69,9].86" [47,] 3.50" [63,5] TORQUE: Steel = 55/60 Ft-Lb. [74/8 Nm] Aluminum = 35/40 Ft-Lb. [47/54 Nm] EPFB-0-X-X-XX-X-X-XXX X TERMINALS BASIC L=8GA. 4" LEADS T=SPADE TERM. SIZE 0=0.875"-4UNF B=BOLT TERM. G=DIN43650 W=WEATHER-PACK D=DEUTSCH-DT04-P SEALS M=METRI-PACK CONN. N = BUNA "N" V = VITON VOLTAGE AMPS D = VDC 3.00 STYLE 4D = 4 VDC.50 C = NORMALLY CLOSED O = NORMALLY OPEN ADJUSTMENT OPTIONS 0 = NONE M = MANUAL OVERRIDE REGULATED FLOW PORTS 04 = 0 TO 4.0 GPM 0 = CARTRIDGE 08 = 0 TO 8.0 GPM BX = G /4" BSPP 3BX = G 3/8" BSPP 6TX = SAE - #6 "A" - ALUM. HOUSING 8TX = SAE - #8 "S" - STEEL HOUSING REGULATED FLOW 8 7 6 5 4 3 GPM AMPERAGE (AMPS) @ 4 VDC 0.5 0.30 0.45 0.60 0.75 0.90.05.0 NORMALLY NORMALLY OPEN CLOSED 0.3 0.6 0.9..5.8..4 AMPERAGE (AMPS) @ VDC 30.3 6.5.7 8.9 5..4 7.6 3.8 L/M Reference: 50-P-50-EN-00/09.05

EPFB-0 PROPORTIONAL, PRIORITY TYPE, PRESSURE COMP, DESCRIPTION This valve is a cartridge style, electro-hydraulic, proportional, priority (BY-PASS) type, pressure compensated, hydraulic flow control. Regulated flow 8.0 GPM [30,3 L/M] max. is proportional to the current input regardless of load or system pressure. After the priority flow is satisfied the excess flow is diverted to a secondary circuit or to tank. Maximum inlet flow is 0.0 GPM [37,9 L/M]. OPERATIONS FLOW CONTROL VALVE. This unit is a direct acting (NO PILOT FLOW), electro hydraulic, proportional, pressure compensated flow control valve. When the coil is energized, the ar- mature moves the metering orifice open against a precision bias spring varying the flow. A pressure compensator spool (HYDROSTAT) modulates the flow at 00 PSI/6,9 Bar delta "P" providing the valve with a constant regulated flow regardless of load or system pressure. For the normally closed product when the current is increased to the coil, the flow will increase. For the normally open product as the current is increased to the coil the flow will decrease. IN THE EVENT OF POWER FAILURE, THE NORMALLY CLOSED VALVE WILL CLOSE AND THE NORMALLY OPEN VALVE WILL OPEN. FEATURES AND BENEFITS Continuous-duty, very low heat rise & waterproof solenoid coil. Interchangeable solenoid coils & termination options available. Hardened precision fitted spool & sleeve provides reliable, long life. Very efficient wet - armature solenoid core tube construction. All external parts are zinc plated for longer life against elements. All cartridge valves are 00% functionally tested. Reference: 50-P-50-EN-00/09.05

EPFB-0 PROPORTIONAL, PRIORITY TYPE, PRESSURE COMP, SPECIFICATIONS FLOW CONTROL VALVE. OPERATING PRESSURE: 5,000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED FLOW: 8.0 GPM [30,3 l/m] Max. See performance chart. INTERNAL LEAKAGE: 0 cu.in/min [38 cc/m] @ 5,000 PSI [350 Bar] VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with current control and a 50 Hz dither. POWER REQUIREMENTS: VDC, Operating current 0. to. AMPS. 4 VDC, Operating current 0. to. AMPS. SEAL KIT: SKN-03 Buna "N" SKV-03 Viton INSTALLATION: No restrictions. WEIGHT:.93 lb [0,90 kg] cartridge with coil only. VALVE CAVITY: #C030, See Page 0-03.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-50-EN-00/09.05

EPFB- ELECTRO-HYDRAULIC, PROPORTIONAL, PRIORITY, PRESSURE COMP, FLOW CONTROL VALVE. 3.78" [45,] MANUAL OVERRIDE ( SCREW TYPE ) TYPE "L" COIL SEE PAGE 0-00. 4.68" [8,9].3" [33,3] Hex. TORQUE to 80/90 Ft-Lb. 4.00" [00/0 N-m]. [0,6].65" 3 [67,3] 3.50" [88,9] BASIC FOR ALUMINUM OR STEEL VALVE HOUSING CONFIGURATIONS SEE PAGE 0-033. EPFB--X-X-XX-X-X-XXX X SIZE =.06"-UNF SEALS N = BUNA "N" V = VITON STYLE C = NORMALLY CLOSED TERMINALS L =8GA. 4" LEADS T =SPADE TERM. B =BOLT TERM. G =DIN43650 W =WEATHER-PACK D =DEUTSCH-DT04-P M =METRI-PACK CONN. VOLTAGE AMPS D = VDC 3.00 4D = 4 VDC.50 O = NORMALLY OPEN ADJUSTMENT OPTIONS 0 = NONE REGULATED FLOW M = MANUAL OVERRIDE 05 = 0 TO 5.0 GPM PORTS 0 = 0 TO 0.0 GPM 5 = 0 TO 5.0 GPM 0 04BX 06BX 0TX TX = CARTRIDGE ONLY = G /"-4 BSPP = G 3/4"-4 BSPP = SAE - #0 = SAE - # "A" = ALUM. HOUSING "S" = STEEL HOUSING REGULATED FLOW 6 4 0 8 6 4 GPM AMPERAGE (AMPS) @ 4 VDC 0.5 0.30 0.45 0.60 0.75 0.90.05.0 NORMALLY OPEN NORMALLY CLOSED 0.3 0.6 0.9..5.8..4 AMPERAGE (AMPS) @ VDC 60.6 53.0 45.4 37.9 30.3.7 5. 7.6 L/M Reference: 50-P-530-EN-0/06.07

EPFB- PROPORTIONAL, PRIORITY TYPE, PRESSURE COMP, DESCRIPTION This valve is a cartridge style, electro-hydraulic, proportional, priority (BY-PASS) type, pressure compensated, hydraulic flow control. Regulated flow 5.0 GPM [56,8 L/M] max. is proportional to the current input regardless of load or system pressure. After the priority flow is satisfied the excess flow is diverted to a secondary circuit or to tank. Maximum inlet flow is 6.0 GPM [98,4 L/M]. OPERATIONS This unit is a direct acting (NO PILOT FLOW), electro hydraulic, pro- portional, pressure compensated, flow control valve. When the coil is energized the armature moves the metering orifice open against a pre- cision bias spring varying the flow. A pressure compensator spool (HYDROSTAT) modulates the flow at 00 PSI/6,9 Bar delta "P" providing the valve with a constant regulated flow regardless of load or system pressure. When current is increased to the coil the flow will increase, as the current is decreased the flow will decrease proportionally. IN THE EVENT OF POWER FAILURE THE VALVE WILL CLOSE. FEATURES AND BENEFITS FLOW CONTROL VALVE. Continuous-duty, very low heat rise & waterproof solenoid coil. Interchangeable solenoid coils & termination options available. Hardened precision fitted spool & sleeve provides reliable, long life. Very efficient wet - armature solenoid core tube construction. All external carbon steel parts are plated for longer life against the elements. All cartridge valves are 00% functionally tested. Reference: 50-P-530-EN-0/06.07

EPFB- PROPORTIONAL, PRIORITY TYPE, PRESSURE COMP, SPECIFICATIONS FLOW CONTROL VALVE. OPERATING PRESSURE: 5,000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED FLOW: 5.0 GPM [56,7 l/m] Max. See performance chart. INTERNAL LEAKAGE: 0 cu.in/min [330 cc/m] @ 5,000 PSI [350 Bar] VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with current control and a 50 Hz dither. POWER REQUIREMENTS: VDC, Operating current 0. to. AMPS. 4 VDC, Operating current 0. to. AMPS. SEAL KIT: SKN-3 Buna "N" SKV-3 Viton INSTALLATION: No restrictions. WEIGHT:.66 lb [,0 kg] cartridge with coil only. VALVE CAVITY: #C30, See Page 0-033.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-530-EN-0/06.07

EPFD-6 ELECTRO-HYDRAULIC, PROPORTIONAL, PRIORITY, PRESSURE COMP, FLOW CONTROL VALVE. 3.78" [45,] MANUAL OVERRIDE ( SCREW TYPE ) TYPE "L" COIL SEE PAGE 0-00. 5.60" [4,].50" [38,] Hex. 4.00" [0,6].90" [73,7] 3 4.00" [0,6] TORQUE: Steel = 95/00 Ft-Lb. [9/36 Nm] Aluminum = 70/75 Ft-Lb. [95/0 Nm] BASIC EPFD-6-X-XX-X-X-XXX X SIZE 6 =.3"-UNF SEALS N = BUNA "N" V = VITON REGULATED FLOW 05 = 0 TO 5.0 GPM 0 = 0 TO 0.0 GPM 5 = 0 TO 5.0 GPM 0 = 0 TO 0.0 GPM TERMINALS L =8GA. 4" LEADS T =SPADE TERM. B =BOLT TERM. G =DIN43650 W =WEATHER-PACK D =DEUTSCH-DT04-P M =METRI-PACK CONN. VOLTAGE AMPS D = VDC 3.00 4D = 4 VDC.50 ADJUSTMENT OPTIONS M = MANUAL OVERRIDE PORTS = CARTRIDGE ONLY 0 = G 3/4" BSPP 06BX = G " BSPP 08BX = SAE - # TX = SAE - #6 6TX "A" = ALUM. HOUSING "S" = STEEL HOUSING REGULATED FLOW 5 0 5 0 5 GPM AMPERAGE (AMPS) @ 4 VDC 0.5 0.30 0.45 0.60 0.75 0.90.05.0 0.30 0.60 0.90.0.50.80.0.40 AMPERAGE (AMPS) @ VDC 95 76 57 38 9 L/M Reference: 50-P-540-EN-00/09.05

EPFD-6 PROPORTIONAL, PRIORITY TYPE, PRESSURE COMP, DESCRIPTION This valve is a cartridge style, electro-hydraulic, proportional, priority (BY-PASS) type, pressure compensated, hydraulic flow control. Regulated flow 0.0 GPM [76,0 L/M] max. is proportional to the current input regardless of load or system pressure. After the priority flow is satisfied the excess flow is diverted to a secondary circuit or to tank. Maximum inlet flow is 35.0 GPM [30,0 L/M]. OPERATIONS This unit is a direct acting (NO PILOT FLOW), electro hydraulic, pro- portional, pressure compensated, flow control valve. When the coil is energized the armature moves the metering orifice open against a pre- cision bias spring varying the flow. A pressure compensator spool (HYDROSTAT) modulates the flow at 00 PSI/6,9 Bar delta "P" providing the valve with a constant regulated flow regardless of load or system pressure. When current is increased to the coil the flow will increase, as the current is decreased the flow will decrease proportionally. IN THE EVENT OF POWER FAILURE THE VALVE WILL CLOSE. FEATURES AND BENEFITS FLOW CONTROL VALVE. Continuous-duty, very low heat rise & waterproof solenoid coil. Interchangeable solenoid coils & terminations options available. Hardened precision fitted spool & sleeve provides reliable, long life. Very efficient wet - armature solenoid core tube construction. All external carbon steel parts are plated for longer life against the elements. All cartridge valves are 00% functionally tested. Reference: 50-P-540-EN-00/09.05

EPFD-6 PROPORTIONAL, PRIORITY TYPE, PRESSURE COMP, SPECIFICATIONS FLOW CONTROL VALVE. OPERATING PRESSURE: 5,000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED FLOW: 0.0 GPM [76,0 l/m] Max. See performance chart. INTERNAL LEAKAGE: 0 cu.in/min [330 cc/m] @ 5,000 PSI [350 Bar] VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with current control and a 50 Hz dither. POWER REQUIREMENTS: VDC, Operating current 0. to. AMPS. 4 VDC, Operating current 0. to. AMPS. SEAL KIT: SKN-63 Buna "N" SKV-63 Viton INSTALLATION: No restrictions. WEIGHT:.66 lb [,0 kg] cartridge with coil only. VALVE CAVITY: #C630, See Page 0-034.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-540-EN-00/09.05

PFCV-0 PROPORTIONAL, NORMALLY CLOSED OR NORMALLY OPEN, IN-LINE, NON-COMPENSATED FLOW CONTROL VALVE. R UL approved coil, IP68 and IP69K rated when used with waterproof connector. TORQUE: Steel = 55/60 Ft-Lb. [74/8 Nm] Aluminum = 35/40 Ft-Lb. [47/54 Nm].78" [45,] MANUAL OVERRIDE ( SCREW TYPE ) 4.35" [0,5] TYPE "L" COIL SEE PAGE 0-00. 5.04" [8,0].00" [50.8].06" [7.0] HEX.7" [3,3].00" [50.8] NOTES:. FOR ALUMINUM OR STEEL VALVE HOUSING CONFIGURATIONS SEE PAGE 0-0.. SOLENOIDS AVAILABLE WITH DIODES - CONSULT FACTORY. 7/8"-4 UNF-A THD. BASIC PFCV-0-X-X-XX-X-X-XXX X SIZE 0 = 7/8"-4UNF SEALS N = BUNA "N" V = VITON STYLE C = NORMALLY CLOSED TERMINALS L =8GA. 4" LEADS T =SPADE TERM. B =BOLT TERM. G =DIN43650 W =WEATHER-PACK D =DEUTSCH-DT04-P M =METRI-PACK CONN. VOLTAGE AMPS D = VDC 3.00 4D = 4 VDC.50 ADJUSTMENT OPTIONS O = NORMALLY OPEN O = NONE M = MANUAL OVERRIDE REGULATED FLOW 04 = 0 TO 4.0 GPM PORTS 08 = 0 TO 8.0 GPM 0 = CARTRIDGE ONLY = 0 TO.0 GPM 0BX = G /4" BSPP 6 = 0 TO 6.0 GPM 03BX = G 3/8" BSPP 06TX = SAE - #6 08TX = SAE - #8 "A" = ALUM. HOUSING "S" = STEEL HOUSING REGULATED FLOW (-) @ 60 PSI P 6 08 04 GPM AMPERAGE (AMPS) @ 4 VDC 0.5 0.30 0.45 0.60 0.75 0.90.05 NORMALLY OPEN NORMALLY CLOSED.0 0.30 0.60 0.90.0.50.80.0.40 AMPERAGE (AMPS) @ VDC 60 45 30 5 L/M Reference: 50-P-00-EN-00/09.05

PFCV-0 PROPORTIONAL, IN-LINE TYPE, FLOW CONTROL VALVE. DESCRIPTION This valve is a cartridge style, electro-hydraulic, proportional, in-line (RESTRICTIVE) type, hydraulic non-compensated flow control. Regulated flow Normally Closed 0 to 6.0 GPM [0 to 6,0 L/m] max. Normally Open 6.0 to 0 GPM [6,0 to 0 L/m] @ 60 PSI DELTA P. Flow is proportional to the current input. OPERATIONS This unit is a direct acting (NO PILOT FLOW), electro hydraulic, pro- portional, non-compensated, flow control valve. When the coil is energized the armature moves the metering orifice to open or to closed position against a precision bias spring varying the flow. When current is increased or decreased to the coil, the flow will increase or decrease proportionally. IN THE EVENT OF POWER FAILURE THE VALVE WILL CLOSE OR OPEN DEPENDING ON THE VALVE VERSION. FEATURES AND BENEFITS Continuous-duty, very low heat rise & waterproof solenoid coil. Interchangeable solenoid coils & termination options available. Hardened precision fitted spool & sleeve provides reliable, long life. Very efficient wet - armature solenoid core tube construction. All external carbon steel parts are plated for longer life against the elements. All cartridge valves are 00% functionally tested. Industry common cavity. Reference: 50-P-00-EN-00/09.05

PFCV-0 PROPORTIONAL, IN-LINE TYPE, FLOW CONTROL VALVE. SPECIFICATIONS OPERATING PRESSURE: 5,000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED FLOW: 6.0 GPM [6,0 L/m] Max. See performance chart. INTERNAL LEAKAGE: 0 cu.in/min [330 cc/m] @ 60 PSI DELTA P [ Bar] VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with current control and a 50 Hz dither. POWER REQUIREMENTS: VDC, Operating current 0.4 to.4 AMPS. 4 VDC, Operating current 0. to. AMPS. SEAL KIT: SKN-0 Buna "N" SKV-0 Viton INSTALLATION: Flow - preferred, Max Flow - lower than shown on graph. Use undercuts in cavity to obtain max rated flow when using a pressure compensator in series. Pressure drop across valve must not exceed 300 PSI [] bar. WEIGHT: 0.74 lbs [0,34 kg] cartridge only..09 lbs [0,50 kg] coil & housing. 0.35 lbs [0,6 kg] aluminum body..0 lbs [0,54 kg] steel body. VALVE CAVITY: #C00, See Page 0-0.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-00-EN-00/09.05

PFCV- PROPORTIONAL, NORMALLY CLOSED OR NORMALLY OPEN, IN-LINE, NON-COMPENSATED FLOW CONTROL VALVE. R UL approved coil, IP68 and IP69K rated when used with waterproof connector..78" [45,] MANUAL OVERRIDE ( SCREW TYPE ) TYPE "L" COIL SEE PAGE 0-00. 4.0" [04,] 4.80" [,9].3"[33,4] HEX.75" [69.9].75" [44,5].06"- UNF-A THD. BASIC SIZE =.06"-UNF SEALS N = BUNA "N" V = VITON STYLE C = NORMALLY CLOSED.75" [69.9] PFCV--X-X-XX-X-X-XXX X TERMINALS L =8GA. 4" LEADS T =SPADE TERM. B =BOLT TERM. G =DIN43650 W =WEATHER-PACK D =DEUTSCH-DT04-P M =METRI-PACK CONN. VOLTAGE AMPS D = VDC 3.00 4D = 4 VDC.50 ADJUSTMENT OPTIONS O = NORMALLY OPEN O = NONE M = MANUAL OVERRIDE REGULATED FLOW 06 = 0 TO 6.0 GPM PORTS = 0 TO.0 GPM 0 = CARTRIDGE ONLY 8 = 0 TO 8.0 GPM 04BX = G /" BSPP 4 = 0 TO 4.0 GPM 06BX = G 3/4" BSPP 0TX = SAE - #0 TX = SAE - # "A" = ALUM. HOUSING "S" = STEEL HOUSING REGULATED FLOW (-) @ 60 PSI P 4 8 06 GPM AMPERAGE (AMPS) @ 4 VDC 0.5 0.30 0.45 0.60 0.75 0.90.05.0 0.30 NORMALLY OPEN 0.60 0.90.0.50 NORMALLY CLOSED.80.0.40 AMPERAGE (AMPS) @ VDC TORQUE: Steel = 70/75 Ft-Lb. [95/0 Nm] Aluminum = 55/60 Ft-Lb. [74/8 Nm] 9 68 45 3 L/M Reference: 50-P-030-EN-00/09.05

PFCV- PROPORTIONAL, IN-LINE TYPE, FLOW CONTROL VALVE. DESCRIPTION This valve is a cartridge style, electro-hydraulic, proportional, in-line (RESTRICTIVE) type, hydraulic non-compensated flow control. Regulated flow Normally Closed 0 to 4.0 GPM [0 to 9, L/M] max. Normally Open 4.0 to 0 GPM [9, to 0 L/m] @ 60 PSI DELTA P. Flow is proportional to the current input. OPERATIONS This unit is a direct acting (NO PILOT FLOW), electro-hydraulic, pro- portional, non-compensated, flow control valve. When the coil is energized the armature moves the metering orifice to open or to closed position against a precision bias spring varying the flow. When current is increased or decreased to the coil the flow will increase or decrease proportionally. IN THE EVENT OF POWER FAILURE THE VALVE WILL CLOSE OR OPEN DEPENDING ON THE VALVE VERSION. FEATURES AND BENEFITS Continuous-duty, very low heat rise & waterproof solenoid coil. Interchangeable solenoid coils & terminations options available. Hardened precision fitted spool & sleeve provides reliable, long life. Very efficient wet - armature solenoid core tube construction. All external carbon steel parts are plated for longer life against the elements. All cartridge valves are 00% functionally tested. Reference: 50-P-030-EN-00/09.05

PFCV- PROPORTIONAL, IN-LINE TYPE, FLOW CONTROL VALVE. SPECIFICATIONS OPERATING PRESSURE: 5,000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED FLOW: 5.0 GPM [94,5 l/m] Max. See performance chart. INTERNAL LEAKAGE: 30 cu.in/min [495 cc/m] @ 60 PSI DELTA P [ Bar] VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with current control and a 50 Hz dither. POWER REQUIREMENTS: VDC, Operating current 0.4 to.4 AMPS. 4 VDC, Operating current 0. to. AMPS. SEAL KIT: SKN- Buna "N" SKV- Viton INSTALLATION: Flow - preferred, Max Flow - lower than shown on graph. Use undercuts in cavity to obtain max rated flow when using a pressure compensator in series. Pressure drop across valve must not exceed 300 PSI [] bar. WEIGHT: 0.84 lbs [0,38 kg] cartridge only..09 lbs [0,50 kg] coil & housing..0 lbs [0,50 kg] aluminum body. 4.0 lbs [,90 kg] steel body. VALVE CAVITY: #C0, See Page 0-03.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-030-EN-00/09.05

PFCV-6 PROPORTIONAL, NORMALLY CLOSED OR NORMALLY OPEN, IN-LINE, NON-COMPENSATED FLOW CONTROL VALVE. R UL approved coil, IP68 and IP69K rated when used with waterproof connector..78" [45.] MANUAL OVERRIDE ( SCREW TYPE ) 4.0" [04,] TYPE "L" COIL SEE PAGE 0-00. 4.80" [,9].50" [38,] HEX 3.00" [76,].80" [45.7].3"- UNF THD. 3.00" [76,] TORQUE: Steel = 95/00 Ft-Lb. [9/36 Nm] Aluminum = 70/75 Ft-Lb. [95/0 Nm] BASIC PFCV-6-X-X-XX-X-X-XXX X SIZE 6 =.3"-UNF SEALS N = BUNA "N" V = VITON STYLE C = NORMALLY CLOSED TERMINALS L =8GA. 4" LEADS T =SPADE TERM. B =BOLT TERM. G =DIN43650 W =WEATHER-PACK D =DEUTSCH-DT04-P M =METRI-PACK CONN. VOLTAGE AMPS D = VDC 3.00 4D = 4 VDC.50 O = NORMALLY OPEN ADJUSTMENT OPTIONS O = NONE REGULATED FLOW M = MANUAL OVERRIDE 06 = 0 TO 6.0 GPM PORTS = 0 TO.0 GPM 8 = 0 TO 8.0 GPM 4 = 0 TO 4.0 GPM 30 = 0 TO 30.0 GPM 36 = 0 TO 36.0 GPM 0 06BX 08BX TX 6TX = CARTRIDGE ONLY = G 3/4" BSPP = G " BSPP = SAE - # = SAE - #6 "A" = ALUM. HOUSING "S" = STEEL HOUSING REGULATED FLOW (-) @ 60 PSI P 36 30 4 8 06 GPM AMPERAGE (AMPS) @ 4 VDC 0.5 0.30 0.45 0.60 0.75 0.90.05.0 NORMALLY OPEN 0.30 0.60 NORMALLY CLOSED 0.90.0.50.80.0 AMPERAGE (AMPS) @ VDC.40 36 4 9 68 46 3 L/M Reference: 50-P-040-EN-00/09.05

PFCV-6 PROPORTIONAL, IN-LINE TYPE, FLOW CONTROL VALVE. DESCRIPTION This valve is a cartridge style, electro-hydraulic, proportional, in-line (RESTRICTIVE) type, hydraulic non-compensated flow control. Regulated flow Normally Closed 0 to 36.0 GPM [0 to 37,0 L/M] max. Normally Open 36.0 to 0 GPM [37,0 to 0 L/m] @ 60 PSI DELTA P. Flow is proportional to the current input. OPERATIONS This unit is a direct acting (NO PILOT FLOW), electro-hydraulic, pro- portional, non-compensated, flow control valve. When the coil is energized the armature moves the metering orifice to open or to closed position against a precision bias spring varying the flow. When current is increased or decreased to the coil the flow will increase or decrease proportionally. IN THE EVENT OF POWER FAILURE THE VALVE WILL CLOSE OR OPEN DEPENDING ON THE VALVE VERSION. FEATURES AND BENEFITS Continuous-duty, very low heat rise & waterproof solenoid coil. Interchangeable solenoid coils & terminations options available. Hardened precision fitted spool & sleeve provides reliable, long life. Very efficient wet - armature solenoid core tube construction. All external carbon steel parts are plated for longer life against the elements. All cartridge valves are 00% functionally tested. Industry common cavity. Reference: 50-P-040-EN-00/09.05

PFCV-6 PROPORTIONAL, IN-LINE TYPE, FLOW CONTROL VALVE. SPECIFICATIONS OPERATING PRESSURE: 5,000 PSI [350 Bar] PROOF PRESSURE: 0,000 PSI [700 Bar] REGULATED FLOW: 36.0 GPM [36,0 l/m] Max. See performance chart. INTERNAL LEAKAGE: 40 cu.in/min [660 cc/m] @ 60 PSI DELTA P [ Bar] VALVE HOUSINGS: 500 PSI [75 Bar] = Aluminum - Anodized. 5000 PSI [350 Bar] = Steel - Unplated. OPERATING TEMPERATURE: -40 to +50 F. [-40 to +0 C.] OPERATING MEDIA: All general purpose hydraulic fluids such as MIL-H-5606, SAE-#0, SAE-#0, etc. RESPONSE: The most efficient method to control this valve is with current control and a 50 Hz dither. POWER REQUIREMENTS: VDC, Operating current 0.4 to.4 AMPS. 4 VDC, Operating current 0. to. AMPS. SEAL KIT: SKN-6 Buna "N" SKV-6 Viton INSTALLATION: Flow - preferred, Max Flow - lower than shown on graph. Use undercuts in cavity to obtain max rated flow when using a pressure compensator in series. Pressure drop across valve must not exceed 300 PSI [] bar. WEIGHT: 0.95 lbs [0,4 kg] cartridge only..09 lbs [0,50 kg] coil & housing..5 lbs [0,57 kg] aluminum body. 4.65 lbs [,0 kg] steel body. VALVE CAVITY: #C60, See Page 0-04.0. info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity 05 by Bucher Hydraulics, Inc., 545 Northwest Parkway, Elgin, Illinois 604, USA All rights reserved. The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Reference: 50-P-040-EN-00/09.05

Proportional 3/ Throttle Cartridge, Size 5 Q max = 30 l/min, p max = 50 bar Sliding-spool design, direct acting Series MDR3GN -5 Description Series MDR3GN direct acting proportional 3/ throttle valves are size 5, high performance screw-in cartridges with a 3/4-6 UNF mounting thread. They are designed on the proven sliding-spool principle. The straightforward design delivers an outstanding price/performance ratio. In the initial position (de-energised), port is closed and ports 3 are connected with the full flow rating. In control mode, the flow through the connection is varied in proportionally to the control current. Three types are available: Type A - standard model, for general use with or without compensator. Type Z - special model, only approved for use with compensator (max. p 5 bar). Type S600 - special model with optimised characteristic - Q = f (I), also only De-energised closed Compact construction for cavity type AM 3/4-6 UNF Very good reproducibility Reliable operation over the whole pressure and flow range (even with high pressure differentials) With optional manual flow setting All exposed parts with zinc-nickel plating High pressure wet-armature solenoids The slip-on coil can be rotated, and it can be replaced without opening the hydraulic envelope Various plug-connector systems and voltages are available Can be fitted in a line-mounting body suitable for use with compensator. With this model, the connection 3 is only used for unloading (see Performance Graphs). These cartridges are particularly suitable for precise and controlled lifting and lowering movements, but they can also be used for reliable operation in mobile and industrial applications featuring large pressure differences. All external parts of the cartridge are zinc-nickel plated to DIN 50 979 and are thus suitable for use in the harshest operating environments. The slip-on coils can be replaced without opening the hydraulic envelope and can be positioned at any angle through 360. If you intend to manufacture your own cavities or are designing a line-mounting installation, please refer to the section Related data sheets. Symbol 3 MDR3GNA5 MDR3GNZ5 3 MDR3GNA5 S600 3 Technical data General characteristics Designation Design Mounting method Tightening torque Description, value, unit proportional 3/ throttle cartridge sliding-spool design, direct acting screw-in cartridge 3/4-6 UNF 40 Nm ± 0 % Reference: 400-P-680-EN-03 Issue: 08.04 /9

General characteristics Size Weight Mounting attitude Ambient temperature range Description, value, unit nominal size 5, cavity type AM 0.40 kg unrestricted (preferably vertical, coil down) -5 C +50 C Hydraulic characteristics Maximum operating pressure Maximum flow rate Nominal flow rate Leakage flow rate Flow direction Description, value, unit 50 bar 30 l/min 5 l/min at p = 0 bar < 50 cm 3 /min (with p N 50 bar) with oil viscosity 33 mm /s (cst) see symbols Hydraulic fluid HL and HLP mineral oil to DIN 5 54; for other fluids, please contact BUCHER Hydraulic fluid temperature range Viscosity range Minimum fluid cleanliness Cleanliness class to ISO 4406 : 999-5 C +70 C 5 380 mm /s (cst), recommended 0...30 mm /s (cst) class 8/6/3 Electrical characteristics Supply voltage Control current Power consumption at max. control current Coil resistance R - cold value at 0 C - max. warm value Recommended PWM frequency (dither) Hysteresis with PWM Reversal error with PWM Sensitivity with PWM Reproducibility with PWM Relative duty cycle Protection class to ISO 0 653 / EN 60 59 Electrical connection Description, value, unit V DC, 4 V DC V = 0 400 ma, 4 V = 0 760 ma max. 9 W V = 5.8 / 4 V = V = 8.6 / 4 V = 3 00 Hz 4 % I N 4 % I N < % I N < % p N 00 % IP 65 / IP 67 / IP 69K, see Ordering code (with appropriate mating connector and proper fitting and sealing) 3-pin square plug to ISO 4400 / DIN 43 650 (standard) for other connectors, see Ordering code /9 400-P-680-EN-03/08.04 Series MDR3GN -5

4 Performance graphs measured with oil viscosity 33 mm /s (cst) For general use with / without compensator type A p = f (Q) Pressure drop - Flow rate characteristic p [bar] 30 5 0 5 0 5 P050.ai Q = f (I; p) Flow rate adjustment characteristic Q [l/min] 30 5 0 5 0 5 P05.ai 50 bar 00 bar 50 bar 00 bar 50 bar 0 0 5 0 5 0 5 30 Q [l/min] 0 00 300 400 500 600 700 I [ma] 400 600 800 000 00 400 I [ma] For use with compensator (max. p = 5 bar) type Z p = f (Q) Pressure drop - Flow rate characteristic p [bar] 0 8 6 4 P05.ai Q = f (I; p) Flow rate adjustment characteristic Q [l/min] 0 5 0 5 P054.ai DW = F06 ) 0 0 5 0 5 0 Q [l/min] 0 00 300 400 500 600 700 I [ma] 400 600 800 000 00 400 I [ma] Q = f ( p; I) Flow rate adjustment characteristic Q [l/min] 0 P053.ai I = 700 / 400 ma I = 650 / 300 ma 5 0 I = 600 / 00 ma I = 550 / 00 ma 5 I = 500 / 000 ma DW = F06 ) 0 0 50 00 50 00 50 p [bar] IMPORTANT! ) Performance graphs measured with compensator model DWDPA-5D-0-F06-400-P-680-EN-03/08.04 Series MDR3GN -5 3/9

With optimised characteristic - Q = f (I), type S600 with compensator (max. p = 5 bar) p = f (Q) Pressure drop - Flow rate characteristic p [bar] 0 P055.ai Q = f (I; p) Flow rate adjustment characteristic Q [l/min] P057.ai 0 DW = F06 ) 8 6 4 5 0 5 0 0 5 0 5 0 Q [l/min] 0 00 300 400 500 600 700 I [ma] 400 600 800 000 00 400 I [ma] Q = f ( p; I) Flow rate adjustment characteristic Q [l/min] 0 5 P056.ai I = 700 / 400 ma I = 600 / 00 ma 0 I = 500 / 000 ma 5 I = 400 / 800 ma DW = F06 ) 0 0 50 00 50 00 50 p [bar] IMPORTANT! ) Performance graphs measured with compensator model DWDPA-5D-0-F06-5 Installation information IMPORTANT! To achieve the proportional 3/ throttle cartridge's maximum performance rating, fit the solenoid coil as shown (with the plug pins at the bottom). When fitting the cartridges, note the mounting attitude (preferably vertical, with coil down automatic air bleed) and use the specified tightening torque. No adjustments are necessary, since the cartridges are set in the factory. ATTENTION! Only qualified personnel with mechanical skills may carry out any maintenance work. Generally, the only work that should ever be undertaken is to check, and possibly replace, the seals. When changing seals, oil or grease the new seals thoroughly before fitting them. 4/9 400-P-680-EN-03/08.04 Series MDR3GN -5

6 Dimensions & sectional view Without manual flow setting standard 7 3 4 39 6 3 4 Ma = 40 [Nm] 0 % 0 8 36 5 40 5 A B Ma =.7 [Nm] 0 % 3 Ma = 5 [Nm] 0 % 74.4 Ma =.7 [Nm] 0 % 56.4 Seal kit NBR no. DS-47-N ) Air-bleeding Item Qty. Description O-ring 8,00 x,00 FKM O-ring no. 07 7,7 x,78 N90 3 O-ring no. 04,4 x,78 N90 4 O-ring no. 03 0,8 x,78 N90 5 O-ring 6,00 x,00 FKM 6 Backup ring 0.70 x.45 x.40 FI075 7 Backup ring 09.40 x.45 x.00 FI075 IMPORTANT! ) Seal kit with FKM (Viton) seals no. DS-47-V If necessary, air can be purged from these proportional throttle cartridges by using the cap nut (Item B). The procedure is as follows: A Knurled nut B Cap nut Steps:. Slacken and remove the knurled nut.. Slacken the cap nut approx..5 turns. Caution: Slackening the cap nut allows oil to spray out! 3. Switch the proportional throttle cartridge ON/OFF several times until no more air bubbles escape. 4. Tighten the cap nut. 5. Refit the knurled nut and tighten it. 400-P-680-EN-03/08.04 Series MDR3GN -5 5/9

With manual flow setting Option E 3 39 3 3 36 66.4 07.4 46.4 D C 3 Ma = 0 [Nm] 0 % Ma = [Nm] 0% 4 74.4 56.4 Integral air-bleeding If necessary, air can be purged from these proportional throttle cartridges by using the integral air-bleed screw (Item D). The procedure is as follows: C Protective cap D Air-bleed screw Steps:. Remove the protective cap.. Slacken the air-bleed screw approx. turns. 3. Switch the proportional throttle cartridge ON/OFF several times until no more air bubbles escape. 4. Tighten the air-bleed screw. 5. Fit the protective cap. 6/9 400-P-680-EN-03/08.04 Series MDR3GN -5

7 Manual flow setting Optionally, the proportional throttle cartridges can be supplied with an integral manual flow setting. If a proportional solenoid is faulty, for example, this manual flow setting enables the required flow rate to be set mechanically. This manual flow setting is not designed for adjusting the flow in a dynamic control mode. G Setting the flow rate manually Steps:. Remove the protective cap.. Slacken the lock nut (3 A/F). 3. Screw in (turn to right) the adjusting spindle (4 A/F) until the required flow rate is set. 4. Tighten the lock nut (3 A/F). 5. Fit the protective cap. E F G F 3 Ma = 0 [Nm] 0 % E 4 Protective cap Lock nut (3 A/F) Adjusting spindle for volume setting Restoring the factory settings Steps:. Solenoid de-energised.. Remove the protective cap. 3. Slacken the lock nut (3 A/F). 4. Unscrew the adjusting spindle (4 A/F) to its end-stop, then screw it in turns. 5. Tighten the lock nut (3 A/F). 6. Fit the protective cap. 8 Application examples Standard type A V 3 Can be used without compensator (full p permissible) Full-flow connection 3 Control is only available with connection M 400-P-680-EN-03/08.04 Series MDR3GN -5 7/9

Special type Z only to be used with compensator V V WV MDR3... 3 MDR3... 3 MDR3... 3 6 bar 6 bar WV IDW F06 IDW F06 DBV 8 bar BDW M Only for use with compensator (max. p = 5 bar) Full-flow connection 3 Control is only available with connection Special type S600 only to be used with compensator MDR3... S600 V Only for use with compensator (max. p = 5 bar) Connection 3 is not full flow (suitable for unloading) Control is only available with connection 3 6 bar 8 bar IDW F06 M BDW 8/9 400-P-680-EN-03/08.04 Series MDR3GN -5

9 Ordering code Ex. M D R 3G N A 5 _ - _ - 4 D M = flow-control valve D = direct acting R = proportional-solenoid operated 3G = 3/ function, de-energised closed N = electrically operated, V DC = 7 W A... Q = can be used with or without compensator (standard) Z = type only for use with compensator Y... R = special features - please consult BUCHER 5 = nominal size 5 (blank) = NBR (Nitrile) seals (standard) V = FKM (Viton) seals (special seals - please contact BUCHER) (blank) = no manual flow setting (standard) E = with manual flow setting... 9 = design stage (omit when ordering new units)... = voltage e.g. 4 (4 V) D = current DC (blank) = ISO 4400 / DIN 43 650 mating plug (standard, IP 65) M00 = without mating DIN plug C = Kostal plug connection (IP 65) JT = Junior Timer radial plug connection (with protection diode, IP65) IT = Junior Timer axial plug connection (with protection diode, IP65) D = Deutsch plug connection DT04-P (IP 67/69K) mating plug not supplied DT = Deutsch plug connection DT04-P (with protection diode, IP 67/69K) S = AMP Superseal.5 (IP 67) / Metri-Pack 50 (IP 65) F = flying leads (500 mm) Ohne = types ( A or Z ) S600 = type with optimised characteristic - Q = f (I), only for use with compensator 0 Related data sheets Reference (Old no.) Description 400-P-0400 (i-3) The form-tool hire programme 400-P-0408 (i-33.) Cavity type AM 400-P-00 (W-.4) Coils for screw-in cartridge valves 400-P-500 Amplifier unit for proportional valves (-channel) PBS - 3A 400-P-50 Amplifier card for proportional valves (-channel) SAN-535 400-P-70 (G-4.0) Line-mounting body, type GAMA (G 3/8 ) info.ch@bucherhydraulics.com www.bucherhydraulics.com 04 by Bucher Hydraulics AG Frutigen, CH-374 Frutigen All rights reserved. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: 430.30.35.305.30.30 400-P-680-EN-03/08.04 Series MDR3GN -5 9/9

Proportional 4/ Throttle Cartridge, Size 5 Q max = 30 l/min, p max = 50 bar Sliding-spool design, direct acting Series MDR4-5 Description Series MDR4 direct acting proportional 4/ throttle valves are size 5, high performance screw-in cartridges with a 3/4-6 UNF mounting thread. They are designed on the proven sliding-spool principle. The straightforward design delivers an outstanding price/performance ratio. "De-energised closed" and "de-energised open" functions are available. In control mode, the flow through the connections 3 und 4 is varied in proportion to the control current. Thanks to these dual flow paths, a higher flow rate is achieved with low headloss. It is essential that ports + 4, and likewise + 3, are joined together in the valve housing (manifold Compact construction for cavity type AN 3/4-6 UNF Dual flow paths for higher flow rate Low headloss For use with inline or bypass pressure-compensator cartridges Reliable operation over the whole pressure and flow range With optional manual flow setting All exposed parts with zinc-nickel plating High pressure wet-armature solenoids The slip-on coil can be rotated, and it can be replaced without opening the hydraulic envelope Various plug-connector systems and voltages are available block). In combination with inline or bypass compensators, these 4/ throttle cartridges are predominantly used in mobile and industrial applications to allow a flow in hydraulic installations to be controlled electro-proportionally. All external parts of the cartridge are zinc-nickel plated to DIN 50 979 and are thus suitable for use in the harshest operating environments. The slip-on coils can be replaced without opening the hydraulic envelope and can be positioned at any angle through 360. If you intend to manufacture your own cavities or are designing a line-mounting installation, please refer to the section Related data sheets. Symbol Dual flow paths 3 3 3 4 4 4 MDR4AD -E MDR4AD MDR4ANK IMPORTANT! To enable the dual flow-path function, ports + 4 and + 3 must be connected within the valve housing (manifold block). Reference: 400-P-680-EN-0 Issue: 0.05 /7

3 Technical data General characteristics Designation Design Mounting method Tightening torque Size Weight Mounting attitude Ambient temperature range Description, value, unit proportional 4/ throttle cartridge sliding-spool design, direct acting screw-in cartridge 3/4-6 UNF 40 Nm ± 0 % nominal size 5, cavity type AN 0.40 kg unrestricted (preferably vertical, coil down) -5 C +50 C Hydraulic characteristics Maximum operating pressure Maximum flow rate Nominal flow rate + 4 + 3 Leakage flow rate Flow direction Description, value, unit 50 bar 30 l/min 5 l/min at p = 4 bar < 50 cm 3 /min (with p N 50 bar) with oil viscosity 33 mm /s (cst) see symbols Hydraulic fluid HL and HLP mineral oil to DIN 5 54; for other fluids, please contact BUCHER Hydraulic fluid temperature range Viscosity range Minimum fluid cleanliness Cleanliness class to ISO 4406 : 999-5 C +70 C 5 380 mm /s (cst), recommended 0...30 mm /s (cst) class 8/6/3 Electrical characteristics Supply voltage Control current Power consumption at max. control current Coil resistance R - cold value at 0 C - max. warm value Recommended PWM frequency (dither) Hysteresis with PWM Reversal error with PWM Sensitivity with PWM Reproducibility with PWM Relative duty cycle Protection class to ISO 0 653 / EN 60 59 Electrical connection Description, value, unit V DC, 4 V DC V = 0 400 ma, 4 V = 0 760 ma max. 9 W V = 5.8 / 4 V = V = 8.6 / 4 V = 3 00 Hz 4 % I N 4 % I N < % I N < % p N 00 % IP 65 / IP 67 / IP 69K, see Ordering code (with appropriate mating connector and proper fitting and sealing) 3-pin square plug to ISO 4400 / DIN 43 650 (standard) for other connectors, see Ordering code /7 400-P-680-EN-0/0.05 Series MDR4-5

4 Performance graphs measured with oil viscosity 33 mm /s (cst) For use with compensator (max. p = 5 bar) p = f (Q) Pressure drop - Flow rate characteristic p [bar] 6 5 4 3 P070.ai Q = f (I; p) Flow rate adjustment characteristic Q [l/min] 35 5 0 5 0 5 P07.ai 30 DW = F06 ) 0 0 5 0 5 0 5 30 Q [l/min] 0 0 00 00 00 300 400 500 600 700 I [ma] 400 600 800 000 00 400 I [ma] Q = f ( p; I) Flow rate adjustment characteristic MDR4AD Q [l/min] 30 5 0 5 0 P0387.ai I = 700 / 400 ma I = 600 / 00 ma I = 500 / 000 ma I = 400 / 800 ma 5 DW = F06 ) 0 0 50 00 50 00 50 p [bar] Q = f ( p; I) Flow rate adjustment characteristic MDR4ANK Q [l/min] 35 30 5 0 5 P0388.ai I = 0 ma I = 300 / 600 ma I = 400 / 800 ma 0 I = 500 / 000 ma 5 DW = F06 ) 0 0 50 00 50 00 50 p [bar] IMPORTANT! ) Performance graphs measured with compensator model DWDPA-5D-0-F06-5 Installation information IMPORTANT! To achieve the proportional 4/ throttle cartridge's maximum performance rating, fit the solenoid coil as shown (with the plug pins at the bottom). When fitting the cartridges, note the mounting attitude (preferably vertical, with coil down automatic air bleed) and use the specified tightening torque. No adjustments are necessary, since the cartridges are set in the factory. ATTENTION! Only qualified personnel with mechanical skills may carry out any maintenance work. Generally, the only work that should ever be undertaken is to check, and possibly replace, the seals. When changing seals, oil or grease the new seals thoroughly before fitting them. 400-P-680-EN-0/0.05 Series MDR4-5 3/7

6 Dimensions & sectional view Without manual flow setting standard MDR4AD... MDR4ANK... 4 9 4 5 53 3 8 4 3 3 7 3/4-6UNF 4 34 Ø 36 6 M A = 40 [Nm] ± 0 % 8 40 A 6 M A =.7 [Nm] ± 0 % 56.4 B M A =.7 [Nm] ± 0 % 3 M A = 5 [Nm] ± 0 % 74.4 Seal kit no. DS-48-N ) Item Qty. Description O-ring 8,00 x,00 FKM O-ring no. 07 7,7 x,78 N90 3 O-ring no. 04,4 x,78 N90 4 O-ring no. 03 0,8 x,78 N90 5 O-ring no. 0 09,5 x,78 N90 6 O-ring 6,00 x,00 FkM 7 Backup ring 0.70 x.45 x.40 FI075 8 Backup ring 09.40 x.45 x.00 FI075 9 Backup ring 07.80 x.45 x.00 FI075 IMPORTANT! ) Seal kit with FKM (Viton) seals no. DS-48-V Air-bleeding If necessary, air can be purged from these proportional throttle cartridges by using the cap nut (Item B). The procedure is as follows: A Knurled nut B Cap nut Steps:. Slacken and remove the knurled nut.. Slacken the cap nut approx..5 turns. Caution: Slackening the cap nut allows oil to spray out! 3. Switch the proportional throttle cartridge ON/OFF several times until no more air bubbles escape. 4. Tighten the cap nut. 5. Refit the knurled nut and tighten it. 4/7 400-P-680-EN-0/0.05 Series MDR4-5

With manual flow setting Option E 4 3 53 3 4 Ø 36 66.4 07.4 60.4 D C M A = 0 [Nm] ± 0 % M A = [Nm] ±0% 56.4 74.4 Integral air-bleeding If necessary, air can be purged from these proportional throttle cartridges by using the integral air-bleed screw (Item D). The procedure is as follows: C Protective cap D Air-bleed screw Steps:. Remove the protective cap.. Slacken the air-bleed screw approx. turns. 3. Switch the proportional throttle cartridge ON/OFF several times until no more air bubbles escape. 4. Tighten the air-bleed screw. 5. Fit the protective cap. 400-P-680-EN-0/0.05 Series MDR4-5 5/7

7 Manual flow setting Optionally, the proportional throttle cartridges can be supplied with an integral manual flow setting. If a proportional solenoid is faulty, for example, this manual flow setting enables the required flow rate to be set mechanically. This manual flow setting is not designed for adjusting the flow in a dynamic control mode. E F G G F 3 M A = 0 [Nm] ± 0 % E Protective cap Lock nut (3 A/F) Adjusting spindle for volume setting 4 Setting the flow rate manually Steps:. Remove the protective cap.. Slacken the lock nut (3 A/F). 3. Screw in (turn to right) the adjusting spindle (4 A/F) until the required flow rate is set. 4. Tighten the lock nut (3 A/F). 5. Fit the protective cap. Restoring the factory settings Steps:. Solenoid de-energised.. Remove the protective cap. 3. Slacken the lock nut (3 A/F). 4. Unscrew the adjusting spindle (4 A/F) to its end-stop, then screw it in /8 turns. 5. Tighten the lock nut (3 A/F). 6. Fit the protective cap. 8 Application examples Used with bypass pressure-compensator cartridge V Classic combination with inline and bypass pressure-compensator cartridges V V 3 WV MDR4ADN... 4 8 bar 3 3 M BDW MDR4ADN... 4 4 MDR4ADN... 6 bar 6 bar 8 bar IDW F06 IDW F06 M BDW 6/7 400-P-680-EN-0/0.05 Series MDR4-5

9 Ordering code Ex. M D R 4AD N A 5 _ - _ - 4 D _ M = flow-control valve D = direct acting R = proportional solenoid 4AD = 4/ function (de-energised open) 4ANK = 4/ function (de-energised closed) N = electrically operated, V DC = 7 W A... Q = type only for use with compensator (standard) Z... R = special features - please consult BUCHER 5 = nominal size 5 (blank) = NBR (Nitrile) seals (standard) V = FKM (Viton) seals (special seals - please contact BUCHER) (blank) = no manual flow setting (standard) E = with manual flow setting... 9 = design stage (omit when ordering new units)... = voltage e.g. 4 (4 V) D = current DC (blank) = ISO 4400 / DIN 43 650 mating plug (standard, IP 65) M00 = without mating DIN plug C = Kostal plug connection (IP 65) JT = Junior Timer radial plug connection (with protection diode, IP65) IT = Junior Timer axial plug connection (with protection diode, IP65) D = Deutsch plug connection DT04-P (IP 67/69K) mating plug not supplied DT = Deutsch plug connection DT04-P (with protection diode, IP 67/69K) S = AMP Superseal.5 (IP 67) / Metri-Pack 50 (IP 65) F = flying leads (500 mm) 0 Related data sheets Reference (Old no.) Description 400-P-0400 (i-3) The form-tool hire programme 400-P-0408 (i-33.) Cavity type AN 400-P-00 (W-.4) Coils for screw-in cartridge valves series D36 400-P-500 400-P-50 Amplifier unit for proportional valves (-channel) PBS - 3A Amplifier card for proportional valves (-channel) SAN-535 info.ch@bucherhydraulics.com www.bucherhydraulics.com 05 by Bucher Hydraulics AG Frutigen, CH-374 Frutigen All rights reserved. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: 430.30.35.305.30.30 400-P-680-EN-0/0.05 Series MDR4-5 7/7

Proportional Throttle Cartridges, Size 5 / SAE 08 Q max = 50 l/min (3 gpm), p max = 50 bar (3600 psi) Two-Stage, with Seat-Valve Shut-Off Series MVRPSBA- Description Series MVRPSBA two stage proportional throttle cartridges are size 5 / SAE 08, high performance screw in valves with a 3/4 6 UNF mounting thread. The main and pilot stages are designed on the poppet/seat principle and are therefore virtually leak free in the flow direction (see symbol). With these proportional throttle cartridges, the flow rate is dependent on the electrical control current, and it can be varied continuously and responsively. When used with a pressure compensator, these cartridges are particularly suitable for precise and load compensated lifting and De-energised closed Seat-valve shut-off in flow direction (see symbol) Q N = 0 l/min (5.3 gpm) at p 0 bar (40 psi) Compact construction for cavity types: AL or C080 3/4-6 UNF Reliable operation over the whole pressure and flow range (even at high pressure differences) Low headloss All external parts zinc plated, passivated (CrVI-free) High pressure wet-armature solenoids The slip-on coil can be rotated, and it can be replaced without opening the hydraulic envelope Various plug-connector systems and voltages are available Can be fitted in a line-mounting body lowering movements, but they can also be used on their own for reliable operation in mobile and industrial applications with large pressure differences. All external parts of the cartridge are zinc plated and passivated (CrVIfree) and are thus suitable for use in the harshest operating environments. The slip-on coils can be replaced without opening the hydraulic envelope and can be positioned at any angle through 360. If you intend to manufacture your own cavities or are designing a line-mounting installation, please refer to the section Related data sheets. Symbol Cavity type AL Cavity type C080 MVRPSBA-LG (size 5) MVRPSBA-G (SAE08) 3 Technical data General characteristics Description, value, unit Designation proportional-throttle cartridge Design seat-valve shut-off, two stage Mounting method screw-in cartridge 3/4-6 UNF Tightening torque 40 Nm ± 0 % (30 ft-lbs ± 0 %) Reference: 400-P-6050-EN-00 Issue: 08.03 /6