P64F - Olympian Plus plug-in system Soft start/dump valves

Similar documents
F64C, F64H - Olympian Plus Plug-In System Puraire high efficiency coalescing filter

BL68 - Olympian Plus plug-in system Filter/regulators and lubricators

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated

T84T - Excelon Plus Modular System 3/2 shut-off valve

V03, V04, V05 (EXCEL 32) 2/2 & 3/2 Direct solenoid actuated poppet valves

T84T - Excelon Plus Modular System 3/2 shut-off valve

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals

F84G - Excelon Plus Modular System General purpose filter

Weight (kg) Dimension No. G1/4 Exhausting None 0,2 1 T F2BG *1) Interface Exhausting None 0,4 3 T10-N10-D2BN

F84C - Excelon Plus Modular System Oil removal filter

L84M, L84C - Excelon Plus Modular System Micro- and oilfog lubricator

F84V - Excelon Plus Modular System Oil vapour removal filters

BL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units

P72F P74F P74F-AD P7 F- - 1/4" (72) 2 3/8" 3 1/2" (74) 4 3/4" (74) 6. ISO G parallel

N/** поставка оборудования для подготовки воздуха

VR61, 3/2, 2 x 3/2, 5/2 or 5/3 Solenoid and pilot actuated spool valves

V44/V45 series, 2 x 3/2, 5/2 & 5/3 Mini ISO Valves

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

VR61 and VR62 3/2, 2 x 3/2, 5/2 and 5/3 directional control solenoid and pilot valves 1/4 or 3/8

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

F64G. Typical flow with 40 µm element at 90 psig (6.3 bar) inlet pressure and a 5 psig (0.35 bar) pressure drop. F64G- N - D 1/4 2 3/8 3 1/2 4 3/4 6

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

25000, 4/2 Direct solenoid actuated poppet valves

24010, 3/2 Direct solenoid actuated poppet valve

Weight (kg) Model L92C- P-ETN. N/en

02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend,

V50... V53 Series 3/2, 5/2 and 5/3 way valves Solenoid actuated and pilot operated 1/8... 1/2

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

, /2 Soft start ( soft clutch ) valve

M/48, M/148. 3/2 Poppet Valves Electrically Actuated. Miniature, 22 mm normally closed and normally open models. Sub-base mounted and manifold mounted

Drain. Element. Flow (dm 3 /s) * B92 - K- T1-RMG. N/en

Nugget 40, V08 series

AUTO STAR with central connector M12x1

60 series, 2/2 or 3/2 Ball valve

BL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units

L84M, L84C - Excelon Plus Modular System Micro-Fog and Oil-Fog Lubricators

Drain. Technical data, standard model, shut off valve, filter/regulator with exhaust port and lubricator. Element

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. Semi-standard

VALVES. V44/V45 Mini ISO Star Valves 2x3/2, 5/2 and 5/3, Solenoid and Pilot Actuated ISO / VDMA Size 26 mm

VM15 series, 2 x 3/2, 5/2 or 5/3 Valve islands

VAL-138. Valves. Electrical Details for Solenoid Pilot. Operating Pressure

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Operating pressure (bar) kv factor (m 3 /h) *3)

3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S)

Excel V03, V04 and V05 Series

Our policy is one of continued research and development. We therefore reserve the right

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

97100 NAMUR. Technical data

26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers.

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. 3 (Closed center) 3/4, 1 3 (Exhaust center)

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

VAL /4" to 2" Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves. Solenoid pilot operated spring return inline valves with nonlocking

Brass ball valves 60 series

SBM TECHNOLOGY Cooling / Air Recovery Valve

PRA/842000/M, PRA/ Clean Line cylinder Magnetic or non-magnetic piston, double acting

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. Semi-standard

Remote Process Actuation Control System AirLINE - Siemens ET 200S

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

VALVES. V40/V41 Mini ISO Star Valves 2x3/2, 5/2 and 5/3, Solenoid and Pilot Actuated ISO / VDMA Size 18 mm

LRA/8000/M/EX, LRA/8000/EX, ISO cylinder Magnetic & Non-magnetic piston, double acting

C D J K N N/UK /02. Our policy is one of continued research and development. We therefore reserve the right

LPRA/182000/M, ISO cylinder Magnetic piston, double acting

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

A44000, LINTRA-LITE Rodless Cylinders Non-magnetic and Magnetic Piston, double acting

83 series Brass compression fittings

82 series Brass compression fittings

Solenoid pilot operated spring return inline valves with nonlocking overrides, 120V, 60 Hz, and cablegrip connector

97105 Inline. Ordering information. Technical data. Accessories See page 5

Valve Islands, V22 Series Sub-base Mounted 2 x 3/2, 5/2 and 5/3 Valves Solenoid Actuated with Wireway

High pressure valves. 80 to 350 bar

SBM TECHNOLOGY PET Blow Valve Block

LRM/55401/M, Roundline cylinder Magnetic piston, double acting

AIR PREPARATION PRODUCTS

HERION. MINI ISO VALVES Size 18 mm, V40 / V41 SERIES Size 26 mm, V44 / V45 SERIES. Flexible subbase system with a wide range of accessories

Series 581 ISO Pneumatic Directional Control Valves

Sectional Directional Control Valve RS 220

/2-way piston valves

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

COMPACT VALVE - 1/4 Series DS2

High Pressure Coolant Valve

HERION SERIES Indirect solenoid actuated soft seal

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Coolant Valve. Air Operated/External Pilot Solenoid

Flow direction: Fixed. G1/4, G1/2 NAMUR G1/ Aluminium xxxx***** G1/4, G1/2 NAMUR G1/ Stainless steel xxxx*****

ROSS CONTROLS. Double Valves for Control Reliable Energy Isolation.

Control Reliable Double Valves with Total Dynamic Monitoring & Complete Memory

Solenoid valve, Metal

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)

/2-way piston valves

5 Port Solenoid Valve

NFPA Double acting imperial cylinders

Transcription:

> Port size: /4... /4 (ISO G/PTF) > Solenoid, air pilot or manual operator > ssists machine designers in complying with the European Machineries Directive > High forward flow and capacity dump facility > Controlled increase of downstream pressure on start up Technical features Medium: Compressed air only Operating pressure: bar (4 psi) minimum 0 bar (45 psi) (Solenoid operated) 7 bar (4 psi) (Pilot operated) Snap pressure: Full flow when downstream pressure reaches 50... 0% of inlet pressure Charge time: For litre downstream volume and, bar (90 psi) inlet pressure 0, sec. minimum 75 sec. maximum Flow: 57 dm /s Operating pressure:, bar (9 psi) Δp: 0,5 bar (7 psi) Port sizes: /4, /, / or /4 ir pilot port: /4 PTF with PTF main ports Rc/4 with ISO G main ports Exhaust port: / PTF with PTF main ports G/ with ISO G main ports Gauge port: / PTF with PTF main ports Rc/ with ISO G main ports mbient/media temperature: Solenoid actuated: -0... +50 C (-4... + F) Pilot actuated: -0... +0 C (-4... +7 F) Version with gauge: -0... +5 C (-4... +49 F) ir supply must be dry enough to avoid ice formation at temperatures below + C (+5 F). Materials: Body & yoke: Zinc alloy Intermediate body: luminium Top plate: Zinc Elastomers: BR Electrical details for solenoid operators Voltage tolerance ± 0% Rating Inlet orifice Electrical connection Technical data - standard models Symbol Port size Size ctuation/ return 00% continuous duty,0 mm Industrial Standard, mm Solenoid coil mounting Four positions x 90 Protection class Voltage Pilot port Weight (kg) G/4 Solenoid/spring 4 V d.c.,07 P4F-GC-PF *) G/ Solenoid/spring 4 V d.c.,05 P4F-GC-PF *) G/ Basic Solenoid/spring 4 V d.c.,0 P4F-4GC-PF *) G/4 Solenoid/spring 4 V d.c., P4F-GC-PF *) Without yoke Solenoid/spring 4 V d.c.,59 P4F-C-PF *) G/4 ir/spring Rc/4,9 P4F-G- G/ ir/spring Rc/4,94 P4F-G- G/ Basic ir/spring Rc/4,9 P4F-4G- G/4 ir/spring Rc/4,7 P4F-G- Without yoke ir/spring Rc/4,45 P4F-- *) To select other solenoid type and coil voltage refer to option selector on page Voltage codes and spare coils IP 5 (with sealed plug) mm coil for connector interface acc. to industrial standard Voltage Power Inrush/Hold Model Code V d.c. W QM/4/J/ J 4 V d.c W QM/4/J/ J 0/0 V 50/0 Hz 4/,5 V QM/4/J/ J 0/40 V 50/0 Hz /5,0 V QM/4/9J/ 9J Connector plugs Industrial standard mm -pole + PE Typ 057 without notice, the specifications given in this document. (00-0f) 05 IMI International s.r.o. en.40.0.0

Option selector Port size /4 / / 4 /4 o yoke Threads PTF ISO G parallel (standard) o yoke (standard) Operator ir pilot (standard) ir pilot with manual lockout G mm solenoid (standard) C mm solenoid with manual lockout B D P4F- - Connector With Without Voltage Watts 4 V d.c. W F V d.c. W E V d.c. W D 0/40 V, 50/0 Hz 4/,5 V B 0/0 V, 50/0 Hz 4/,5 V o coil Z o solenoid Solenoid manual operator on-locking, P shrouded push button one Flow characteristics Pressure drop Δ p psi 0 4 0 0bar 0, 0,4 0, Inlet pressure bar (psi) 4,0 (44) (5), (9) () 0 (50) 0 0 40 0 0 00 dm /s 0 40 0 0 0 00 scfm ir flow Maximum charge time Outlet pressure psi 0 0 0 40 0 liter volume Snap Point 4 0 0 40 0 0 00 0 0bar s Charge time en.40.0.0 without notice, the specifications given in this document. (00-0f) 05 IMI International s.r.o.

ccessories Models with G-thread Single yoke Double yoke / Shut-off valve Threaded inlet only Threaded outlet only End connector kit Rear entry bracket kit Thread G/4 Y4-G- Y4-G- T4T-GB-P T4T-GC-P G/ Y4-G- Y4-G- T4T-GB-P T4T-GC-P G/ Y4-4G- Y4-4G- T4T-4GB-P T4T-4GC-P 74505-50 G/4 Y4-G-* Y4-G-* T4T-GB-P T4T-GC-P 74505-5 -0-9 /4 PTF Y4-- Y4-- T4T-B-P T4T-C-P / PTF Y4-- Y4-- T4T-B-P T4T-C-P / PTF Y4-4- Y4-4- T4T-4B-P T4T-4C-P 74505-5 /4 PTF Y4--* Y4--* T4T-B-P T4T-C-P 74505-55 *These yokes are supplied with two end connenctor kits as standard. Bracket mounting ut Silencer Yoke connector kit Porting block djustable pressure switch Padlock with two keys 74504-50 7450-9 MB004B (R/) 7450-5 74507-50 44-99 0 (brass) MB004 (/ PT) Gauges Center back connection, white face (full technical specification see datasheet.900.900) Pressure range bar * MPa psi Ø Thread size Model 0... 0 0... 0... 45 50 mm R/ -0-0 0... 5 0...,5 0... 50 mm R/ -0-04 *) primary scale Center back connection, black face for orth merica (full technical specification see datasheet.900.900) Pressure range psig * bar MPa Ø Thread size Model 0... 0 0... 0.... (50 mm) / PT -0-04 0... 400 0... 0.... (50 mm) / PT -0-0 *) primary scale without notice, the specifications given in this document. (00-0f) 05 IMI International s.r.o. en.40.0.0

Dimensions Pilot actuated Standard With manual lockout Dimensions in mm Projection/First angle 4 # 55 7 5 or / 7 # 0 57 05 74 5 ø 5 5 Solenoid actuated Standard With manual lockout 95 # 5 55 7 5 or / 7 Pg 9 4 57 05 74 04 # 5 # Minimum clearance required to remove unit from yoke Main ports /4, /, / or /4 5 ø Pilot port Rc/4 For main ports /4 only 5 5 5 Exhaust port / 7 Gauge port / en.40.0.04 without notice, the specifications given in this document. (00-0f) 05 IMI International s.r.o.

Single yoke with bracket mounting 4 4 Double yoke with bracket mounting 94 Dimensions in mm Projection/First angle 5 0 9, 0,5, 4,5, 5 4 4 0 9, 0,5 4,5 57 0 Rear entry bracket -0-9 Porting block 74507-50 4 5, 9,5 G /4 50,5 59 ø G/ 0,5 +0, 7,5 54,5 5 4 4,5 4,5,5 G/4 - O -ring (included in scope of supply of bracket) djustable pressure switch 44-99 Pg 7 Voltage Current Pressure range 4 V d.c./40 V a.c. 0,5 (d.c.); 5 (a.c.)... 0 bar Repeatabillity % of full set point range at 0 C 7 verage deadband Electrical connection (corresponding to choosen coil) 0,...,7 bar E 750-0 - Form C, 5 mm 4 5 Degee of protection: djustable Material IP5 Standard Body: luminium, Elastomers: BR 59 ø 4 djusting screw / Shut-off valve Symbol B ø C Model 7 B G/4 4 7 T4T-G*-P G/ 4 7 T4T-G*-P 7 OPE G/ 4 7 T4T-4G*-P G/4 5 T4T-G*-P ø C * B = Threaded inlet only, C = Threaded outlet only Rc /,5 7 7,5 7 Padlock hole ø7,5 mm without notice, the specifications given in this document. (00-0f) 05 IMI International s.r.o. en.40.0.05

Silencer C Dimensions in mm Projection/First angle Ø D B B C D Model R/ 7 9 MB004B / PT 7 9 MB004 Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, orgren GmbH. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. en.40.0.0 without notice, the specifications given in this document. (00-0f) 05 IMI International s.r.o.