Best-selling Basic Switch Boasting High Precision and Wide Variety

Similar documents
OMRON Z LIMIT SWITCH

Best-selling Basic Switch Boasting High Precision and Wide Variety

Best-selling Basic Switch Boasting High Precision and Wide Variety

Best-selling Basic Switch Boasting High Precision and Wide Variety

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Subminiature Basic Switch

Direct Current Switch with Built-in Magnetic Blowout

Z/A/X/DZ Common Accessories Z/A/X/DZ Ordering Information

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Z/A/X/DZ Common Accessories Z/A/X/DZ Ordering Information

D2SW. Sealed Subminiature Basic Switch. Ordering Information Model Number Legend D2SW-

Small Limit Switch D4V

Safety Limit Switch

Subminiature Basic Switch

Low-torque Basic Switch

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Model Number Structure

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

Pre-wired Models D4C- (1) (2) (3) (4)

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Technical Guide for Basic Switches

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

HL (AZH) LIMIT SWITCHES

2NC (slow-action) Direct. Model. opening

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Technical Explanation for Basic Switches

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

AM1 (NZ BASIC) SWITCHES

Manual Reset Limit Switch

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

HL (AZH) Limit Switches

Safety Limit Switch

Model Number Structure

HL (AZH) Limit Switches

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Safety-door Switch. Ordering Information

Hinged Safety Door Switch

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

TURQUOISE STROKE SWITCHES

Model Number Structure

Turquoise Stroke Switches

List of Models Short post on Long post on left left. Without posts Actuator Terminals Contact form

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) A22E/A22NE-P

2NC (slow-action) Direct. Model. opening

Turquoise Stroke Mini Switches

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models.

TURQUOISE STROKE SWITCHES

High sensitivity. Low current load type. type. Short plunger ~ Fine plunger ~ ~ Lever ~ Roller lever ~ Short roller lever ~

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Ordering Information. Text Surface-Mounting Signal Relay G6K

Miniature Limit Switches

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Limit Switches Technical Information

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Specifications. Model Number Structure

Lighted Pushbutton Switch

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

WL-N/WLM-N. Two-circuit Limit Switch/Long-life Two-circuit Limit Switch

Limit Switches with Positive Opening Mechanism

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Robust General-Purpose Limit Switch WL

Multiple Limit Switch

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

High Operating Precision Basic Switches with High Capacity and Long Life

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

PERFORMANCE IP67 (IEC60529, JIS C 0920) Silver contact: Max.50 mω (6 to 8 Vdc, energizing current 1A, measured by voltage drop method) Gold alloy cros

QL (AZ4) Limit Switches

SL (AZ3) Micro Limit Switches

SL1Series. Compact Horizontal Limit Switches

Sliding contact construction Switches for Low-level Loads

Miniature Pre-Leaded Vertical Enclosed Switches

1LS-J700 SERIES ULTRA LONG LIFE, GENERAL-PURPOSE COMPACT LIMIT SWITCHES

TURQUOISE SWITCHES J TYPE (ABJ)

A165E CSM_A165E_DS_E_11_2

D4GS-N CSM_D4GS-N_DS_E_7_2

TURQUOISE SWITCHES J TYPE (ABJ)

Lighted PushButton Switch

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

D4NH CSM_D4NH_DS_E_7_1

BZSeries. Basic Switches

BZSeries. Basic Switches

Transcription:

General-purpose Basic Switch Z CSM_Z_DS_E_4_4 Best-selling Basic Switch Boasting High Precision and Wide Variety A large switching capacity of A with high repeat accuracy. A wide range of variations in contact form for your selection: basic, split-contact, maintained-contact, and adjustable contact gap types. A series of standard models for micro loads is available. A series of molded terminal-type models incorporating safety terminal protective cover is available. Be sure to read Safety Precautions on page 6 and Safety Precautions for All Basic Switches. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Configuration Basic models Split-contact models Maintained-contact models General-purpose Drip-proof General-purpose General-purpose Without terminal protective cover With terminal protective cover Molded terminal Refer to page. Refer to page. Refer to page. Refer to page. Refer to page 4. Refer to page 4. Basic Models General-purpose A variety of actuators is available for a wide range of application. The contact mechanism of models for micro loads is a crossbar type with gold-alloy contacts, which ensures highly reliable operations for micro loads. Contact Gap: H: 0.0 mm (extra-high-sensitivity) H: 0. mm (high-sensitivity, micro voltage current load) G: 0. mm (standard) E:.8 mm (high-capacity) Drip-proof These Switches use a rubber boot on the actuator and adhesive fill between the case and cover to increase resistance to drips. Models with drip-proof terminal protective covers and molded terminals with resin filling are also available. Split-contact Models This type is identical in construction to the general-purpose basic switch except that it has two pairs of simultaneous acting contacts by splitting moving contacts. Since the moving contacts are connected to a common terminal, either parallel or series connection is possible. Highly reliable micro load switching is ensured if the model is used as a twin-contact switch. Maintained-contact Models The maintained-contact type has a reset button at the bottom of the switch case, in addition to the pushbutton (plunger) located on the opposite side of the reset button. Use these buttons alternately. Since the Switch has greater pretravel than overtravel, it is suitable for use in reversible control circuits, manual reset circuits, safety limit circuits, and other circuits which are not preferable for automatic resetting. (For further details, refer to individual datasheets.)

Model Number Legend Basic Models Z-@@@@-@ ()()()(4) () () Ratings 0 : 0. A (micro load) : A () Contact Gap H : 0.0 (extra-high-sensitivity) H : 0. mm (high-sensitivity, micro load) G : 0. mm (standard) E :.8 mm (high-capacity) () Actuator None : Pin plunger S : Slim spring plunger D : Short spring plunger K : Spring plunger (medium ) K : Spring plunger (high ) Q : Panel mount plunger (low ) Q : Panel mount plunger (medium ) Q8 : Panel mount plunger (high ) Q : Panel mount roller plunger Q : Panel mount cross roller plunger L : Leaf spring (high OF) L : Roller leaf spring W : Short hinge lever W : Hinge lever (low OF) W : Hinge lever (medium OF) W : Hinge lever (high OF) W4 : Low-force hinge lever W44 : Long hinge lever W78 : Low-force wire hinge lever (low OF) W : Low-force wire hinge lever (high OF) W : Short hinge roller lever W : Hinge roller lever W : Hinge roller lever (large roller) W49 : Short hinge cross roller lever W4 : Hinge cross roller lever W77 : Unidirectional short hinge roller lever (low OF) M : Reverse hinge lever M : Reverse short hinge roller lever M : Reverse hinge roller lever NJ : Flexible rod (high OF) NJS : Flexible rod (low OF) (4) Degree of Protection None : General-purpose : Drip-proof (not include the terminals) A : Drip-proof (including the terminals) () Terminals None : Solder terminal B : Screw terminal (with toothed washer) BV : Screw terminal with terminal cover (for Z-G@A only) Note: For combinations of models, Ordering Information on page to 6. Standard Models (Drip-proof Type/Molded Terminals) Z-@-M@@ @M () ()() (4) () Drip-proof Type () Lead Outlets None : VSF 9 : VCT () Directions of Lead Outlets (See following diagrams.) L : Left R : Right D : Descending (4) Length of Lead Outlets : m : m Split-contact Models Z-0F@Y-B () ()()(4) () () Ratings 0 : 0 A (split-contact models) () Contact Gap F : mm (high-capacity) () Actuator None : Pin plunger S : Slim spring plunger D : Short spring plunger Q : Panel mount plunger Q : Panel mount roller plunger W : Hinge lever W : Short hinge roller lever W : Hinge roller lever M : Reverse short hinge roller lever (4) Construction Y : Split-contact models () Terminals B : Screw terminal (with toothed washer) L Type D Type R Type Maintained-contact Models Z--E@R () ()()(4) () Ratings : A () Contact Gap E :.8 mm (high capacity) () Actuator None : Pin plunger S : Slim spring plunger W : Hinge lever (4) Structure R : Maintained-contact models

Z Ordering Information Main Unit Basic Models (General-purpose) Classification Actuator Contact gap Terminal * Pin plunger Slim spring plunger Short spring plunger Panel mount plunger Standard High-sensitivity G (0. mm) Model H (0. mm) Model Z-H Z-E Z-0H Z-H-B Z-E-B Z-0H-B Z-GS Z-HS Z-GS-B Z-HS-B Z-GD Z-HD Z-GD-B Z-HD-B Z-GQ Z-GQ Z-HQ Z-GQ-B Z-HQ-B High Z-GQ8-B Z-GQ8 Z-HQ Z-HQ-B Panel mount cross roller plunger Z-GQ Z-HQ Z-GQ-B Z-HQ-B Z-GL Z-GL Z-GL-B Z-GW Z-GW-B Lowforce wire hinge lever Z-0HQ Z-0HQ-B Z-EQ Z-EQ-B Z-EQ Z-EQ-B -- Z-HW Medium Z-GW-B High Z-GW-B Z-GW Z-GW4 Z-HW4 Z-GW4-B Z-HW4-B Z-HW78 Z-HW78-B Z-HW Z-HW-B Z-HW Z-GW-B Z-HW-B Short hinge cross roller lever Z-GW49-B Reverse hinge lever * Z-EQ Z-EQ-B Z-GW Unidirectional short hinge roller lever Z-HW-B Z-GW49 Standard Z-GW Z-HW Z-GW-B Z-HW-B Large roller Z-GW-B Z-GW Z-GW4 Hinge cross roller lever Short hinge roller lever Hinge roller lever Z-0HD Z-0HD-B Z-GW High Z-ED Z-ED-B Z-GW-B Low Z-0HS Z-0HS-B Low Z-GW Z-GQ Z-GL-B Z-GQ-B Low-force hinge lever H (0. mm) Model Z-H Panel mount roller plunger Hinge lever E (.8 mm) Model Z-H-B Medium Short hinge lever Micro load Z-G Z-GQ-B Roller leaf spring High-capacity Z-G-B Low Leaf spring Extra-high sensitivity H (0.0 mm) Model Z-GW4-B -- Z-EW Z-0HW Z-EW-B Z-0HW-B -- Z-GW77 Parallel Z-GW77-B Z-GM Z-GM-B Z-GM Reverse short hinge roller lever * Z-GM-B Reverse hinge roller lever * Z-GM-B Z-GM *. : Solder terminal : Screw terminal *. The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers are normally pressed.

Minimum Order Lot The following models are available at the minimum order lot specified below. Orders must be placed per lot. Classification Actuator Standard High-sensitivity Short spring plunger Z-GD-B Z-GQ Panel mount plunger Z-GQ-B Z-GQ8-B Z-GQ Panel mount roller plunger Z-GQ-B Panel mount cross roller plunger Z-GQ-B Short hinge lever Z-GW-B Z-GW Hinge lever Z-GW-B Low-force hinge lever Z-GW4-B Z-HW4-B Low-force hinge wire lever Z-HW78-B Z-GW Short hinge roller lever Z-GW-B Z-GW Hinge roller lever Z-GW-B Reverse short hinge roller lever Z-GM-B Reverse hinge roller lever Z-GM-B Minimum order lot (pcs) 0 Split-contact Models Contact gap F (.0 mm) Actuator Terminal * Model Pin plunger Z-0FY-B Slim spring plunger Z-0FSY-B Short spring plunger Z-0FDY-B Panel mount plunger Z-0FQY-B Panel mount roller plunger Z-0FQY-B Hinge lever Z-0FWY-B Short hinge roller lever Z-0FWY-B Hinge roller lever Z-0FWY-B Reverse short hinge roller lever * Z-0FMY-B *. : Solder terminal : Screw terminal *. The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers are normally pressed. Maintained-contact Models Actuator Pin plunger Slim spring plunger Hinge lever Model Z-ER Z-ESR Z-EWR 4

Basic Models (Drip-proof Models Standard, Microload ) Actuator Pin plunger Short spring plunger Spring plunger Panel mount plunger Panel mount roller plunger Panel mount cross roller plunger Leaf spring Roller leaf spring Short hinge lever Long hinge lever Hinge lever Short hinge roller lever Hinge roller lever Classification Standard Micro load Contact gap G (0. mm) H (0. mm) Drip-proof terminal protective cover Not provided Provided Not provided Terminal * Model Model Model Z-G Z-0H Z-G-B Z-GA-BV Z-0H-B Z-GD Z-0HD Z-GD-B Z-0HD-B Low Z-GK Z-GK-B High Z-GK Z-GK-B Z-GKA-BV Z-GQ Z-GQ-B Z-GQA-BV Z-GQ Z-GQ-B Z-GQA-BV Z-GQ-B Z-GQA-BV Z-GL Z-GL-B Z-GL Z-GL-B Z-GW Z-GW-B Z-GW44 Z-GW44-B Z-GW44A-BV Z-GW Z-GW-B Z-GWA-BV Z-GW Z-0HW Z-GW-B Z-GWA-BV Z-0HW-B Z-GW Z-GW-B Z-GWA-BV Unidirectional short hinge roller lever Z-GW77 Z-GW77-B Z-GW77A-BV Reverse hinge lever * Reverse short hinge roller lever * Reverse hinge roller lever * Flexible rod (coil spring) * Z-GM Z-GM-B Z-GM Z-GM-B Z-GM Z-GM-B Z-GNJ Z-GNJ-B *. : Solder terminal : Screw terminal *. The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. *. The tip is made of resin. Minimum Order Lot The following models are available at the minimum order lot specified below. Orders must be placed per lot. Classification Standard Minimum order Actuator Contact gap G (0. mm) lot (pcs) Short spring plunger Z-GD-B Spring plunger Z-GK-B Z-GW44-B Hinge lever Z-GW Z-GW-B 0 Short hinge roller lever Z-GW Z-GW-B Hinge roller lever Z-GW-B Flexible rod (coil spring) Z-GNJ-B

Basic Models (Drip-proof Models High-sensitivity ) Classification High-sensitivity Contact gap H (0. mm) Drip-proof terminal protective cover Not provided Actuator Terminal * Model Flexible rod (steel wire) Z-HNJS Z-HNJS-B Minimum Order Lot The following models are available at the minimum order lot specified below. Orders must be placed per lot. Classification High-sensitivity Minimum order Actuator Contact gap H (0. mm) lot (pcs) Flexible rod (steel wire) Z-HNJS-B 0 * : Solder terminal : Screw terminal Specifications Ratings (Basic, Split-contact and Maintained contact Models) Z- (Except Micro Load and Flexible Rod Models) Contact gap G, H, H, E G H, H E * Figures in parentheses are for the Z-HW, Z-HW78(-B) and Z-H(-B) models, the AC ratings of these models are and 0 V only. Z- (Flexible Rod Models) Z-0F Item Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load Rated NC NO NC NO NC NO NC NO voltage VAC 0 VAC 00 VAC * 8 VDC 4 VDC 0 VDC VDC 0 VDC 8 VDC 4 VDC 0 VDC VDC 0 VDC 8 VDC 4 VDC 0 VDC VDC 0 VDC Rated voltage VAC 0 VAC 8 VDC 4 VDC 0 VDC VDC 0 VDC Contact gap Series connection Parallel connection (0) * (0) * 0 6 0. 0. 0.4 0. 0.7 0.. 0. 0. 0.4 0. 0.7 0.. 0.7 0. 0..4 0.4 0. 0.7 0. (0) * (0) * 6 0 0.0 0.0 0 0.0 0.0 0 0.4 0. 0.0 0.0 0.0 0.0 0.4 0.. 0.7... 0.0 0.0.. 0.0 0.0... 0.4 0. Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO 0.4 0. 0.4 0. 0. 0.4 0. 7 7 7 0.0 0.0. 0.0 0.0 0. 0.0 0.0 Item Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load Rated NC NO NC NO NC NO NC NO voltage VAC 0 VAC 0 VDC VDC 0 VDC VAC 0 VAC 0 VDC VDC 0 VDC 0 0 0 0.6 6 6 6 0.6 0. 4. 4 0.6. 4 0.6 0. 0.6. 0.6 0. 6 6 6 0. 0.0 4 4 4 0. 0.0 6 0. 0.0 4 6 0. 0.0. 0. 0.0 0. 0.0 Z-0H Rated voltage Resistive load (A) NC NO VAC 0. 8 VDC 4 VDC 0 VDC 0. 0. 0. Note:. The above current ratings are the values of the steady-state current.. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).. Lamp load has an inrush current of 0 times the steady-state current. 4. Motor load has an inrush current of 6 times the steady-state current.. The normally closed and normally open ratings of reverse hinge lever models are opposite to each other. 6. The AC ratings of molded terminals are and 0 V only. 7. The ratings values apply under the following test conditions: () Ambient temperature: 0± C () Ambient humidity: 6±%RH () Operating frequency: 0 operations/min Use the switch within the operating range. Voltage (V) 0 4 0 0. mw 0.6 ma Unusable range Minimum applicable load ma Micro load area Z-0H 0 00,000 Z-0H 800 mw 6 ma Standard load area Z-H, H Z-G Z-E Z-0FY Z-ER 00 ma 60 ma Current (ma) Z-@, Z-0FY VDC ma VDC 60 ma 6

Certified Standard Ratings Ask your OMRON representative for information on certified models. UL/CSA (General ratings only) Rated voltage Model Z- Z-0F Z-0H VAC A /8HP 6A /0HP 0.A 0 VAC A /4HP 6A /8HP 480 VAC A 6A 0 VDC 0.A VDC 0.A 0.6A 0 VDC 0.A 0.A Characteristics TÜV (EN608-) CCC (GB4048.) *. The values are for the plunger models. (For the lever models, the values are at the plunger section.) (Consult your OMRON representative for other models.) *. The values are for the Z-G pin plunger. *. The values are for the Z-0FY-B. *4. The values are for the pin plunger. The durability for models other than the pin plunger is 0,000,000 min. *. Malfunction: ms max. Contacts Specification Engineering Data Mechanical Durability (Z-G) Rated voltage Model Z-H@ Z-G@ Z-0H@ 0 VAC A A VAC 0. A 0 VDC 0. A Rated voltage Model Z-H@ Z-G@ Z-0H@ 0 VAC A A VAC 0. A 0 VDC 0. A Item Classification load and flexible rod) Z- (except micro Z-0H Z- (flexible rod) Z-0F Z-H Operating speed 0.0 mm to m/s * mm to m/s 0. mm to m/s * 0.0 mm to m/s Operating Mechanical 40 operations/min 0 operations/min 40 operations/min 40 operations/min frequency Electrical 0 operations/min Insulation resistance 00 MΩ min. (at 00 VDC) Contact resistance mω max. (initial value) 0 mω max. (initial value) mω max. (initial value) mω max. (initial value) mω max. (initial value) Dielectric strength Between contacts of same polarity Contact gap G:,000 VAC, 0/60 Hz for min Contact gap H: 600 VAC, 0/60 Hz for min Contact gap E:,00 VAC, 0/60 Hz for min Between contacts of same polarity Contact gap G:,000 VAC, 0/60 Hz for min Contact gap H: 600 VAC, 0/60 Hz for min Between contacts of same polarity Contact gap F:,00 VAC, 0/60 Hz for min Between contacts of same polarity 600VAC, 0/60Hz for min Between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts,000 VAC, 0/60 Hz for min Vibration 0 to 0 Hz, -mm double Malfunction 0 to Hz, -mm double amplitude * resistance amplitude * 0 to Hz, -mm double amplitude * Shock Destruction,000 m/s max. resistance Malfunction 00 m/s max. * * 0 m/s max. * 00 m/s max. * * 00 m/s max. Durability Mechanical Contact gap G, H: 0,000,000 operations min. 00,000 operations 0,000,000 operations,000,000 operations min. Contact gap E: 00,000 operations min. * min. Electrical Contact gap G, H: 00,000 operations min. 00,000 operations 00,000 operations 00,000 operations min. Contact gap E: 00,000 operations min. min. min. Degree of General-purpose IP00 protection Drip-proof Equivalent to IP6 (except terminals) Degree of protection against electric shock Class I Proof tracking index (I) 7 Ambient operating General-purpose C to 80 C (with no icing) temperature Drip-proof C to 80 C (with no icing) Ambient operating General-purpose % to 8%RH humidity Drip-proof % to 9%RH Weight Approx. to 8 g Approx. 4 to 48 g Approx. 4 to 6 g Approx. g Item Classification Z- Z-0H Z-0F Contacts Shape Rivet Single crossbar Rivet Material Silver Gold alloy Silver Inrush current NC 0 A max. 0. A max. 40 A max. NO A max. 0. A max. 0 A max. Durability (x0 4 operations) 0,000,000,000,000 00 00 Ambient temperature: 0± C Ambient humidity: 6±%RH Without load Operating frequency: 40 operations/min Electrical Durability (Z-G) Durability (x0 4 operations),000,000,000 00 00 00 0 0 Ambient temperature: 0± C Ambient humidity: 6±%RH Operating frequency: 0 operations/min. VAC cos dia. = VAC cos dia. = 0.4 0 VAC cos dia. = 0 VAC cos dia. = 0.4 00 VAC cos dia. = 00 VAC cos dia. = 0.4 00 0 0. 0. 0. 0.4 0. 0.6 0.7 0.8 Overtravel (mm) 0 0 4 6 8 0 4 6 Switching Current (A) 7

Structure Z Basic Models Contact Form (SPDT) COM Note: The Z-GM is a reversible model and the NO and NC positions are reversed. Molded Terminals COM (Black) NC NO (Red) NC (White) NO ( ) indicates wire color. Split-contact Models Contact Form COM NO Note: The NO and NC terminal arrangement is reversed for Models with reverse operation (Z-0FM). Connection Example Series Connection NC NO NC Parallel Connection Note: The Z-GM is a reversible model and the NO and NC positions are reversed. Structure Drip-proof Construction Without Terminal Protective Cover Rubber boot Fixed contact (b) Movable spring Glued surface (adhesive is filled between case and cover) Movable contact Maintained-contact Models Contact Form Spring pivot Fixed contact (a) With Terminal Protective Cover COM NC NO Rubber boot (weather-resistive chloroprene is used) Pushbutton for resetting Stainless-steel stopper (improves sealing) Rubber packing (improves sealing between switch housing and terminal cover) Terminal protective covers are sold separately for maintenance purposes, which can be, however, used with the Z-@-BV models only. For details, refer to page. 8

Dimensions Z (Unit: mm) Mounting Use M4 screws with plane washers and spring washers to mount the Switch. Tighten each mounting screw securely to a torque of.8 to.47 N m. Two, 4. dia. mounting holes or M4 +0.. 0 dia. When mounting the Switch to a panel, use a tightening torque of.94 to 4.9 N m for the hexagonal nuts on the actuator. Panel Mount Plunger Panel Mount Roller Plunger +0.. 0 dia. +0. 0 +0. 0 Basic Models Terminals Screw Terminals (-B) General-purpose and Split-contact Models Basic Models Solder Terminal (-A) ( -A is not included in the model numbers.) Split-contact Models Screw Terminals (Y-B).6 6.4 0 0 7. COM NO NC Three, M4. Terminal screws (with toothed washer) Appropriate terminal screw tightening torque: 0.78 to.8 N m. NO COM NC Note: With reverse action models (Z-GM), the positions of NO and NC terminals are reversed. Five, M.. terminal screws (with toothed washer) Appropriate terminal screw tightening torque: 0.49 to 0.78 N m. Note: With reverse action models (Z-0FM), the positions of NO and NC terminals are reversed. COM NO NO NC NC Dimensions and Operating Characteristics The models, illustrations, and graphics are for screw-terminal models (-B). The -A at the end of the model number for solder terminal models has been omitted. For details of the terminals, see above. Pin Plunger Z-G-B Z-H-B Z-H-B Z-E-B Z-0H-B Z-0FY-B Operating Characteristics Operating force OF Release force Pretravel Overtravel Movement Differential Operating Position.±0. +0.07 4. dia. hole. dia..sr * 4. * Stainless-steel plunger Model Z-G-B Z-H-B Z-H-B Z-E-B Z-0H-B Z-0FY-B.4 to.4 N 0.4 mm 0. mm 0.0 mm.96 to. N 0. mm 0. mm 0.00 to 0.008 mm.96 to.7 N 0. mm 0. mm 0.0 mm.9±0.4 mm 6. to 7.8 N 0. mm 0. mm.4 N max. 0.78 N 0. mm 0. mm 0.04 mm 4.46 to 7.6 N 0. mm 0. mm Slim Spring Plunger Z-GS-B Z-0HS-B Z-HS-B Z-0FSY-B 9 dia..±0. * +0.07 4. dia. hole. dia. 4 dia. 4. * Stainless-steel plunger (flat, R chamfered) OF Z-GS-B Z-HS-B Z-0HS Z-0FSY-B.4 to.4 N 0.4 mm 0.0 mm.96 to.79 N 0. mm 0.0 mm 8.±0. mm.4 N max. 0.78 N 0. mm 0.0 mm 4.46 to 7.6 N 0. mm Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 9

Short Spring Plunger Z-GD-B Z-0HD-B Z-HD-B Z-0FDY-B Z-ED-B.±0. SR * +0.07 4. dia. hole. dia. 0 dia. 7. dia. 4. * Plated iron plunger OF Z-GD-B Z-HD-B Z-ED-B Z-0HD-B Z-0FDY-B.4 to.4 N 0.4 mm 0.0 mm.96 to.79 N 0. mm 0.0 mm 6. to 7.8 N 0. mm ±0. mm.4 N max. 0.78 N 0. mm 0.0 mm 4.46 to 7.6 N 0. mm Panel Mount Plunger Z-GQ-B Z-0HQ-B Z-HQ-B Z-0FQY-B Z-EQ-B Z-GQ-B * Z-GQ8-B *. *4 6. * The external dimensions of the actuator vary. 6 dia..±0. SR * +0.07 4. dia. hole 8. dia. M mounting screw *. Stainless-steel plunger *. Two hexagonal nuts ( t 4 width across flats) *. Two lock nuts ( t.6 width across flats) *4. Incomplete screw part with a maximum length of mm. * * Note:. Do not use the M mounting screw and the case mounting hole at the same time, or excessive pulling force will be imposed on the switch and the case and cover may be damaged.. On the model Z-GQ-B, can be set to a value larger than that for the Z- GQ.. On the model Z-GQ8-B, operating position can be adjusted by providing a screw in the plunger section. 4. On the model Z-GQ8-B, the M hole with a depth of 0 mm is a through hole. Take precautions so that no water or screw lock agent penetrates into the hole. Z-GQ-B Z-HQ-B Z-EQ-B Z-0HQ-B Z-0FQY-B Z-GQ-B Z-GQ8-B OF.4 to.4 N.96 to.79 N 6. to 7.8 N.4 N max. 0.78 N 4.46 to 7.6 N.4 to.4 N.4 to.4 N 0.4 mm 0. mm 0. mm 4. mm 0. mm. mm 0.0 mm. mm 0.0 mm. mm 0. mm. mm 0.0 mm. mm 0. mm. mm. mm. mm 0.0 mm.8± 8.8±.± mm Panel Mount Roller Plunger Z-GQ-B Z-EQ-B Z-HQ-B Z-0FQY-B.±0..7 dia. 4.8 * *. 6. * 6 dia. +0.07 4. dia. hole M mounting screw *. Stainless-steel roller *. Two hexagonal nuts ( t 7 width across flats) *. Incomplete screw part with a maximum length of mm. Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. OF Z-GQ-B Z-HQ-B Z-EQ-B Z-0FQY-B.4 to.4 N 0.4 mm.8 mm 0.0 mm.96 to.79 N 0. mm.8 mm 0.0 mm.4±. mm 6. to 7.8 N.8 mm 0. mm 4.46 to 7.6 N mm. mm 0. mm Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 0

Panel Mount Cross Roller Plunger Z-GQ-B Z-EQ-B.±0..7 dia. 4.8 * Z-HQ-B Z-GQ-B Z-HQ-B OF.4 to.4 N.96 to.79 N * 0.4 mm 0. mm. +0.07 4. dia. hole M.8 mm.8 mm mounting screw 0.0 mm 0.0 mm * 6. 6 dia..4±. mm Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. *. Stainless-steel roller *. Two hexagonal nuts ( t 7 width across flats) *. Incomplete screw part with a maximum length of mm. OF Z-EQ-B 6. to 7.8 N.8 mm 0. mm.4±. mm Leaf Spring Z-GL-B 49.6±0.8 t = 0.* +0.07 4. dia. hole 4.8 * Stainless-steel spring lever.9 OT *min..8 N 0.4 N. mm max. 0.6 mm 7.4± * When operating, be sure not to exceed. Roller Leaf Spring Z-GL-B 46 ±0.8 t = 0. * 9. dia. 4 (plastic toller) +0.07 4. dia. hole.9 * Stainless-steel spring lever OT *min..8 N 0.4 N. mm max..8 mm 8.6± * When operating, be sure not to exceed. Short Hinge Lever Z-GW-B 8.R 4.9 0. 6.9.9 +0.07 4. dia. hole max. 7 N 0.7 N mm mm 4.8 mm 9± Hinge Lever Z-GW-B Z-GW-B Z-HW-B Z-0FWY-B Z-GW-B (Lever Length: 6R)* 6.R 0. 6.9.9 4.9 +0.07 4. dia. hole * The external dimensions of the actuator vary. OF Z-GW-B Z-HW-B Z-GW-B Z-0FWY-B Z-GW-B 0.69 N max. 0.4 N.6 mm.7 mm 0.66 N max. 0.4 N.6 mm 0.6 mm.47 to.96 N 0.9 N.6 mm.7 mm 0.88 N max. 0.4 N.6 mm.4 mm 0.78 N max. 0. N 4.8 mm. mm max. 8. mm 7.4 mm 8. mm 9.8 mm 7. mm 9± Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

Low-force Hinge Lever Z-GW4-B 6.R 4.9 0. 6.9.9 +0.07 4. dia. hole 74 mn 4. mn 0 mm.6 mm.7 mm 9±0.8mm Z-HW4-B 0R R 0 t = 0.8 * 0. 6.9.9 +0.07 4. dia. hole 7.4 ±0. 8.8 mn 4.90 mn 9.8 mm 0 mm mm 9.8± Low-force Wire Hinge Lever Z-HW-B Z-HW78-B (Lever Length: 0R) * * The external dimensions of the actuator vary. Note: AC electrical ratings: 0 A, /0 V. max. 0. 6.9.9 +0.07 4. dia. hole 6.R * Stainless-steel wire lever Z-HW-B 8.8 mn 4.90 mn 8. mm.6 mm 0.6 mm 9± mm Z-HW78-B mn.94 mn 0 mm 6 mm mm 0± mm Short Hinge Roller Lever Z-GW-B Z-0HW-B Z-HW-B Z-0FWY-B Z-EW-B Z-GW-B * Z-HW-B * Z-0FWY-B * 6.6R 0. 6.9.9 9. dia. 4 (plastic roller) max. * The external dimensions of the actuator vary. (Lever Length: 48.R) +0.07 4. dia. hole Z-GW-B Z-HW-B Z-EW-B Z-0HW-B Z-0FWY-B Z-GW-B Z-HW-B Z-0FWY-B 7 N 0.4 N.4 mm 0. mm. mm 0.±0.4 mm.47 N 0.4 N.4 mm 0.4 mm.94 N 0.4 N.4 mm. mm. mm 0.±0.4 mm 7 N 0.7 N.4 mm 0. mm. mm 0.±0.4 mm.4 N 0.4 N.4 mm mm 4.8 mm 0.±0.4 mm 0.98 N 0. N 4 mm.0 mm 6. mm 0.± 0.84 N 0. N 4 mm 0.6 mm.7 N 0. N 4 mm mm 7.4 mm 0.± Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

Short Hinge Cross Roller Lever Z-GW49-B Z-GW4-B (Lever Length: 48.7R) * 7.R 9. dia. 4 (plastic roller) * The external dimensions of the actuator vary. 0. 6.9.9 +0.07 4. dia. hole max. Z-GW49-B.67 N 0.4 N.4 mm 0. mm. mm ±0.4 mm Z-GW4-B 0.98 N 0. N 4 mm mm 7. mm ± Hinge Roller Lever Z-GW-B 0R t = * 0 dia. 4 R (plastic roller) 0. 6.9.9 +0.07 4. dia. hole max. 0.98 N 0. N 4 mm 47. mm 4.± Unidirectional Short Hinge Roller Lever Z-GW77-B 4. max. Operating direction.9r 0. 6.9.9.R +0.07 4. dia. hole 9. dia. 4 (plastic roller) max..67 N 0.4 N.4 mm 0. mm 4.6 mm 4.± Reverse Hinge Lever ** Z-GM-B 8.6 6R 4.9 0. 7.4.9 +0.07 4. dia. hole max..67 N 0.7 N.6 mm 0.89 mm.8 mm 9± Reverse Short Hinge Roller Lever ** Z-GM-B Z-0FMY-B 8.6 8.R 0. 7.4.9 +0.07 4. dia. hole 9. dia. 4 (plastic roller) max. Z-GM-B.8 N.67 N mm.8 mm 9.4±0.4 mm Z-0FMY-B 6.7 N.67 N mm 0.6mm mm 9.4±0.4 mm Reverse Hinge Roller Lever ** Z-GM-B 8.6 40.6R t = * 9. dia. 4 (plastic roller) 0. 7.4.9 +0.07 4. dia. hole max.. N 0. N 4 mm 0.64 mm mm 0.± ** The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers are normally pressed. Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

Basic Models (Drip-proof) without Terminal Protective Cover Terminals (Molded Terminals: Refer to page.) Without Terminal Protective Cover 0 0 COM NO NC Three, M4. Terminal screws (with toothed washer) Note: With reverse action models (Z-GM), the positions of NO and NC terminals are reversed. Dimensions and Operating Characteristics The above illustration is for model without terminal protective cover. Pin Plunger Z-G-B Z-0H-B 6SR *.±0. +0.07 4. dia. hole.9 dia..9 * Stainless-steel plunger OF Z-G-B Z-0H-B.4 to 4. N.4 N max. 0.78 N. mm. mm 0. mm 0. mm 0.06 mm 0.06 mm.9±0.4 mm Short Spring Plunger Z-GD-B Z-0HD-B SR *.±0. +0.07 4. dia. hole dia. 7. dia..9 * Stainless-steel plunger Z-GD-B Z-0HD-B.0 N.6 N 0.78 N.8 mm.9 mm 0.06 mm 0.06 mm ±0. mm Spring Plunger Z-GK-B SR *.±0. 7 dia. 7. dia. +0.07 4. dia. hole.9 * Stainless-steel plunger.0 N. mm 0.06 mm 8.±0. mm Z-GK-B SR *. ±0. 7 dia. 8. dia. +0.07 4. dia. hole. * Stainless-steel plunger.0 N.4 mm. mm 0.06 mm 7.8±. mm Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 4

Panel Mount Plunger Z-GQ-B. 6. *4 6 dia..±0. SR * +0.07 4. dia. hole 8. dia. *. Stainless-steel plunger *. Two hexagonal nuts ( t 4 width across flats) *. Two lock nuts ( t.6 width across flats) *4. Incomplete screw part with a maximum length of mm. M Mounting screw * *.0 N.8 mm. mm 0.06 mm.8± Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. Panel Mount Roller Plunger Z-GQ-B.±0..7 dia. 4.8 *. * 6. 6 dia. +0.07 4. dia. hole *. Stainless-steel roller *. Two hexagonal nuts ( t 7 width across flats) *. Incomplete screw part with a maximum length of mm. * M mounting screw.0 N.8 mm.8 mm 0.06 mm.4±. mm Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. Panel Mount Cross Roller Plunger Z-GQ-B.±0..7 dia. 4.8 *. 6. * 6 dia. +0.07 4. dia. hole *. Stainless-steel roller *. Two hexagonal nuts ( t 7 width across flats) *. Incomplete screw part with a maximum length of mm. * M mounting screw.0 N.8 mm.8 mm 0.06 mm.4±. mm Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. Leaf Spring Z-GL-B 49.6±0.8 t = 0. * +0.07 4. dia. hole 4.8.9 * Stainless-steel spring lever OT *min..96 N 0.4 N. mm max. 0.6 mm 7.± * When operating, be sure not to exceed. Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

Roller Leaf Spring Z-GL-B 46 ±0.8 t = 0.* 9. dia. 4 (plastic roller) +0.07 4. dia. hole 7.4 ±0..9 OT *min..96 N 0.4 N. mm max..8 mm 8.6± * When operating, be sure not to exceed. Short Hinge Lever Z-GW-B 8.R t = * 4.9 0. 6.9.9 +0.07 4. dia. hole +0. 4.6 dia. -0.0 max..86 N 0.7 N mm mm mm 9± Long Hinge Lever Z-GW44-B 00R 4.9 0. 6.9.9 +0.07 4. dia. hole max. 0.88 N 0.4 N.6 mm. mm mm 9±. mm Hinge Lever Z-GW-B 6.R t = * 4.9 0. 6.9.9 +0.07 4. dia. hole 7.4 ±0. max. 0.98 N 0.4 N.6 mm mm 8. mm 9± Short Hinge Roller Lever Z-GW-B Z-0HW-B 6.6R 9. dia. 4 (plastic roller) 0. 6.9.9 +0.07 4. dia. hole max. Z-GW-B.96 N 0.4 N.4 mm.9 mm 0.±0.4 mm Z-0HW-B.96 N 0.7 N.4 mm Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 6

Hinge Roller Lever Z-GW-B 48.R 9. dia. 4 (plastic roller) 0. 6.9.9 +0.07 4. dia. hole max..7 N 0. N 4 mm 6. mm 0.± Unidirectional Short Hinge Roller Lever Z-GW77-B 4. max. Operating direction.9r 0. 6.9.9.R +0.07 4. dia. hole 9. dia. 4 (plastic roller) 7.4 ±0. max..77 N 0.49 N.4 mm 4.6 mm 4.± Reverse Hinge Lever * Z-GM-B 8.6 6R 4.9 0. 7.4.9 +0.07 4. dia. hole 7.4 ±0. max..96 N 0.7 N.6 mm 0.89 mm.8 mm 9± Reverse Short Hinge Roller Lever * Z-GM-B 8.6 9. dia. 4 (plastic roller) 8.R 0. 7.4.9 +0.07 4. dia. hole max..69 N.67 N mm.8mm 9.4±0.4mm Reverse Hinge Roller Lever * Z-GM-B 8.6 40.6R 9. dia. 4 (plastic roller) 0. 7.4.9 +0.07 4. dia. hole 7.4 ±0. max..6 N 0. N 4 mm 0.64 mm mm 0.± * The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 7

Flexible Rod (Coil Spring) Z-GNJ-B 6. dia.. dia. * Nylon rod 8 0 Operating range * (.) 4.4 Rubber cap dia. (.6) 6..±0. +0.07 4. dia. hole 0.49 N (0 mm) TT max. 40 mm *. Operation is possible in any direction other than the axial direction (indicated by the arrow ). *. Use only the area within the top 0 mm of the rod as the operating part. (Do not use the area that falls within 80 mm from the mounting hole as the operating part. Using this area may cause damage to the nylon rod. Flexible Rod (Steel Wire) Z-HNJS-B * 0 Operating range * -dia. stainless steel wire * 00±0.4 (0.) () Four, M set screws with hexagonal holes Rubber cap dia. (.8) 6..±0. +0.07 4. dia. hole 0. N ( mm) *. Operation is possible in any direction other than the axial direction (indicated by the arrow ). *. Use only the area within the top 0 mm of the rod as the operating part. (Do not use the area that falls within 00 mm from the mounting hole as the operating part. Using this area may cause damage to the steel wire.) *. The steel wire can be replaced if damaged. (Model: Lever for HNJS) Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 8

Basic Models (Drip-proof) with Terminal Protective Cover Dimensions and Operating Characteristics Pin Plunger Z-GA-BV 6SR *.±0..9 dia..8.7 +0.07 4. dia. hole (8.8) 4.7 () 7.4 ±0. * Stainless-steel plunger.4 to 4. N. mm 0. mm 0.06 mm.9±0.4 mm Z-GKA-BV 7 dia. SR *. ±0. 8. dia. +0.07 4..8.7 +0.07 4. dia. hole (8.8) 4.7 () 7.4 ±0. * Stainless-steel plunger.0 N.4 mm. mm 0.06 mm 7.8±. mm Panel Mount Plunger Z-GQA-BV SR *.±0.. 6. 6 dia..8.7 +0.07 4. dia. hole (8.8) 8. dia. M P = () *. Stainless-steel plunger *. Two hexagonal nuts ( t 4 width across flat) *. Two lock nuts ( t.6 width across flats) * *.0 N.8 mm. mm 0.06 mm.8± Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. Panel Mount Roller Plunger Z-GQA-BV.±0. 6.. 6 dia..7 dia. 4.8 * * M P =.0 N.8 mm.8 mm 0.06 mm.4±. mm.8.7 +0.07 4. dia. hole (8.8) () *. Stainless-steel roller *. Two hexagonal nuts ( t 7 width across flats) Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. Panel Mount Cross-roller Plunger Z-GQA-BV. ±0. 6.. 6 dia..7 dia. 4.8 * * M P =.0 N.8 mm.8mm 0.06 mm.4±. mm.8.7 +0.07 4. dia. hole (8.8) () 7.4 ±0. *. Stainless-steel roller *. Two hexagonal nuts ( t 7 width across flats) Note: Do not use the M mounting screw and the case mounting hole at the same time, or the case may be damaged. Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 9

Long Hinge Lever Z-GW44A-BV 00R 4.9 0. 6.9.9.8.7 +0.07 4. dia. hole (8.8) () max. 0.88 N 0.4 N.6 mm. mm mm 9±. mm Hinge Lever Z-GWA-BV 6.R 4.9 0. 6.9.8.7 +0.07 4. dia. hole (8.8).9 () max. 0.98 N 0.4 N.6 mm mm 8. mm 9± Short Hinge Roller Lever Z-GWA-BV 6.6R 9. dia. 4 (plastic roller) 0. 6.9.8.7 +0.07 4. dia. hole (8.8).9 7.4 ±0. () max..96 N 0.4 N.4 mm.9 mm 0.±0.4 mm Hinge Roller Lever Z-GWA-BV 48.R 9. dia. 4 (plastic roller) 0. 6.9.8.7 +0.07 4. dia. hole (8.8).9 () max..7 N 0. N 4 mm 6. mm 0.± Unidirectional Short Hinge Roller Lever Z-GW77A-BV Operating direction 9. dia. 4 (plastic roller).9r 4. max. 0. 6.9 +0. 4.6 dia. -0.0.7 +0.07 4. dia. hole.8.r (8.8).9 () max..77 N 0.49 N.4 mm 4.6 mm 4.± Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 0

Basic Models (Drop-proof) with Modeled terminals Molded Terminals L/R Type (The following illustration is the R type.) D Type a c a b 8 Lead Wire Specifications Specifications Lead wire VSF (single-core, vinyl cord) VCT (vinyl-insulated cable) Size (mm) Lead wire Nominal cross sectional area (mm). a b c VSF 4 VCT 9 0 Finished outer diameter (mm) Approx.. dia. Three-core: approx. 0. dia. Note:. No models with molded terminals are approved by UL, CSA, or EN.. Molded terminals are not available on all models. Contact your OMRON representative for applicable products. b Connection to terminal Black:COM White:NO Red: NC Length (m), c Size (mm) Lead wire a b c VSF 4 VCT 9 6 Maintained-contact Models Dimensions and Operating Characteristics Pin Plunger Z-ER. ±0. 4.±0. +0.07 4. dia. hole.4 6.4 Reset button *. dia..sr * Reset position 7. min. 6.4 dia. Reset free position 9. max. Plunger Reset Button.96 to.0 N 0.4 mm 0. mm.9±0.4 mm COM NO NC *. Stainless steel plunger *. Plastic plunger 0. to.79 N 0.4 mm Slim Spring Plunger Z-ESR 9 dia.. ±0. * 4. ±0. +0.07 4. dia. hole.4 6.4. dia. 4 dia. Reset position 7. min. 6.4 dia. Reset free Reset button * position 9. max. *. Stainless steel plunger (tip only, flat, R bevel). *. Plastic plunger Plunger Reset Button.6 N 0.4 mm 8.±0. mm.79 N 0.4 mm Hinge Lever Z-EWR 6.R 4.9 Lever Tip 0. 6.9 4. ±0..9 +0.07 4. dia. hole 6.4 Reset position 7. min. 6.4 dia. Reset button * *. Stainless steel lever *. Plastic plunger Reset free position 9. max. max. Reset Button 0.4 N.6 mm 8. mm 9±.94 N 0.4 mm Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

Accessories (Order Separately) A Terminal Protective Cover, Actuators, and a Separator are available. Drip-proof Terminal Cover (Order Separately) The Drip-proof Terminal Protective Cover is provided for maintenance for Z-@A-BV Switches. Ordering Information Dimensions (Unit: mm) Name Model Drip-proof Terminal Protective Cover AP-DV Mounting bracket Terminal Covers (Sold Separately) The Terminal Covers can be attached to Z, A, X, and DZ Switches. The Terminal Cover is secured with mounting screws and protects the casing and terminal wires from dust, vibration, or fingers, thus preventing terminal short-circuiting, ground faults, wire disconnection or improper connection, and electric shock accidents. Terminal Covers made of phenol resin have five or six thin wall sections. These sections can be torn open for providing holes for lead cables at desired points. A terminal cover can t be used in the case of using an actuator sold separately. Operation Information Application Soldering terminal use Screw terminal use Material Mounting direction Model Remarks Phenol resin Side mounting AP-A AP-B Metal press mold Side mounting AP-A AP-B Used for AP-A and AP-B Vinyl chloride Side mounting AP-Z Note: Use a Terminal Cover for screw terminals fir DZ-series Switches with soldering terminals. Separator (Sold Separately) Use a Separator when it is difficult to provide a sufficient insulation distance or when using the Switch near metal parts or copper wires. Operation Information Model SEPARATOR FOR Z

Dimensions (Unit: mm) Terminal Covers AP-A Soldering Terminal Use (Phenol Resin).8 4. +0..4 0 4. +0. 0.R 8 6. 6. AP-B Screw Terminal Use (Phenol Resin).8 4. +0..4 0 4. +0. 0.R 8 6. 0. 8 8 Note: The Cover has five thin, easy-to-separate portions for easy lead wire connections. Note: The Cover has six thin, easy-to-separate portions for easy lead wire connections. AP-A Soldering Terminal Use (Metal Press Mold) 4.4 4. +0..4 0 4. +0. 0.R 8 7. 7. AP-B Screw Terminal Use (Metal Press Mold).4 4. +0..4 0 4. +0. 0.R 8 7 8..6 8..6 Note: The Cover has five holes for easy lead wire connections. AP-Z Soldering or Screw Terminal Use (Vinyl Chloride) Pressure plate (t steel) 4 Two, 4. dia. Note: The Cover has six holes for easy lead wire connections..8.4 Cable Pull-out Dimension 7 A-A' cross-section B-B' cross-section Nut M 0 Phillips screw (with plane washer and nut) Note: Each dimension has a tolerance of ±0.4 mm unless otherwise specified. (± for the AP-Z) A B A' B' 9 46 8 dia. 6 dia. Note: A 6-dia. or 8-dia. cable can be used by cutting the cable pull-out hole to the size of the cable to be used. Separator Two, 4. dia...4±0. ±0. t = 0. 7±0. Note:. Each dimension has a tolerance of ±0.4 mm unless otherwise specified.. The material is EAVTC (Epoxide Alkyd Varnished Tetron Cloth) and its heat-resisting temperature is 0 C.

Actuators (Sold Separately) A Switch can be actuated by a cam or an appropriate object, in which case, use one of the following Actuators according to the application. Ordering Information Actuator Application Common to Z and X models Hinge lever XAA- Hinge roller lever Panel mount plunger Panel mount roller plunger Short Medium Long ZAA- ZAQ- ZAQ- ZAQ- ZAQ- Dimensions (Unit: mm) and Operating Characteristics Hinge Lever XAA- XAA- XAA- 9. 9.4 8. 0. Two, M4 Two, M4 0 7 * 60R Note: These Actuators are not provided with Switches. * Stainless steel Model Operating characteristics Operating force Release force Overtravel Movement Differential Free Position max. Operating Position Z-G-B 4.90 N.67 N.7 mm. mm.9± 8.9± X-0G-B 4.90 N.67 N.7 mm. mm Note: This Actuator can be used with the Z-G(-B) and X- 0G(-B). When mounting the Switch, set the overtravel to between % and 00%, taking into consideration the operating body and the distance between the Actuator and the dog. Hinge Roller Lever ZAA- Two, M4 Two, M4 0 9. * 7 9.4 8. 0. 8.R. 9. dia. 4.8 * max. Z-G-B 4.90 N.67 N.7 mm. mm 44.± 40.4± X-0G-B 4.90 N.67 N.7 mm. mm Note: This Actuator can be used with the Z-G(- B) and ZX-0G(-B). When mounting the Switch, set the overtravel to between % and 00%, taking into consideration the operating body and the distance between the Actuator and the dog. *. Stainless steel roller *. Stainless steel Short Panel Mount Plunger ZAQ-.6 0.7 * *.. SR *.4 4. dia. *.6 7. 4. 7.9 dia. M mounting screw t 4 width across flats t.6 width across flats Two, M4 nuts Two, M4 screws 0.7 *. Stainless-steel pin plunger *. Bronze frame *. Incomplete screw section part with a maximum of mm ZAQ- Z-E-B X-0G-B 8.4 N 4.8 mm 0. mm 7.8± mm.9 N mm 4. mm 0. mm Note:. This Actuator (pin plunger) can be used with Standard Pin Plungers (Z-G(-B), Z-E(-B), X-0G(-B), DZ-0G-A(-B)) for the Z, X, and DZ models. Note: Each dimension has a tolerance of ±0.4 mm unless otherwise specified. 4

Medium Panel Mount Plunger ZAQ-. SR *.6 * 4. dia. 4.8 7.9 dia. M mounting screw t 4 width across flats t.6 width across flats ZAQ- Z-E-B X-0G-B 8.4 N 4.8 mm 0. mm.± mm.9 N mm 4. mm 0. mm 0.7.6 4. Two, M4 screws Note: This Actuator (pin plunger) can be used with Standard Pin Plungers (Z-G(-B), Z-E(- B), X-0G(-B), DZ-0G-A(-B)) for the Z, X, and DZ models. *..4 0.7 Two, M4 nuts *. Stainless-steel pin plunger *. Copper alloy frame *. Incomplete screw section part with a maximum of mm Long Panel Mount Plunger ZAQ-. SR * 0.7.6 * 4. dia..6 4.8 4. 7.9 dia. M mounting screw t 4 width across flats t.6 width across flats Two, M4 screws ZAQ- Z-E-B X-0G-B 8.4 N 0.6 mm 0. mm.9 N mm 0.4 mm 0. mm 69.± mm Note: This Actuator (pin plunger) can be used with Standard Pin Plungers (Z-G(-B), Z-E(- B), X-0G(-B), DZ-0G-A(-B)) for the Z, X, and DZ models. *..4 Two, M4 nuts 0.7 *. Stainless-steel pin plunger *. Copper alloy frame *. Incomplete screw section part with a maximum of mm Panel Mount Roller Plunger ZAQ-.6 * 0.7 * 48.±0. 4. dia..4±0. 8.9.7 dia. * 4.8 Two hex nuts -mm thickness, 9 mm between opposing edges With groove for roller penetration M mounting screw ZAQ- Z-E-B DZ-0G-B 8.4 N mm.8 mm 0. mm. N mm mm 0.46 mm 7±.4±. mm.9 Note: This Actuator (roller plunger) can be used with standard pin plungers (Z-G(-B), Z-E(-B), and DZ-0G-A(-B)). It cannot be used with X models. Two, M4 Spring washer 0.7 screws *. Stainless-steel pin plunger *. Steel frame *. Incomplete screw section part with a maximum of mm Note: Each dimension has a tolerance of ±0.4 mm unless otherwise specified.

Safety Precautions Z Refer to Safety Precautions for All Basic Switches. Terminal Connection When soldering lead wires to the Switch, make sure that the capacity of the soldering iron is 60 W maximum. Do not take more than s to solder any part of the Switch. The characteristics of the Switch will deteriorate if a soldering iron with a capacity of more than 60 W is applied to any part of the Switch for s or more. Operation Make sure that the switching frequency or speed is within the specified range..if the switching speed is extremely slow, the contact may not be switched smoothly, which may result in a contact failure or contact welding..if the switching speed is extremely fast, switching shock may damage the Switch soon. If the switching frequency is too high, the contact may not catch up with the speed. The rated permissible switching speed and frequency indicate the switching reliability of the Switch. The life of a Switch is determined at the specified switching speed. The life varies with the switching speed and frequency even when they are within the permissible ranges. In order to determine the life of a Switch model to be applied to a particular use, it is best to conduct an appropriate durability test on some samples of the model under actual conditions. Make sure that the actuator travel does not exceed the permissible OT position. The operating stroke must be set to 70% to 00% of the rated OT. Mounting Location Do not use the switch alone in atmospheres such as flammable or explosive gases. Arcing and heat generation associated with switching may cause fires or explosions. Switches are generally not constructed with resistance against water. Use a protective cover to prevent direct spraying if the switch is used in locations subject to splashing or spurting oil or water, dust adhering. Install the switch in a location that is not directly subject to debris and dust from cutting. The actuator and the switch body must be protected from accumulated cutting debris and dirt. Incorrect Precautions for Safe Use Precautions for Correct Use Incorrect Terminal box Terminal box Correct Correct Do not use the switch in locations subject to hot water (greater than 60 C) or in water vapor. Do not use the switch outside the specified temperature and atmospheric conditions. The permissible ambient temperature depends on the model. (Refer to the specifications in this catalog.) Sudden thermal changes may cause thermal shock to distort the switch and result in faults. Incorrect Mount a cover if the switch is to be installed in a location where worker inattention could result in incorrect operation or accidents. Incorrect Correct (preventing malfunctions) Correct Separate the installation location from heat sources. Subjecting the switch to continuous vibration or shock may result in contact failure or faulty operation due to abrasion powder and in reduced durability. Excessive vibration or shock will cause the contacts to operate malfunction or become damaged. Mount the switch in a location that is not subject to vibration or shock and in a direction that does not subject the switch to resonance. If silver contacts are used with relatively low frequency for a long time or are used with microloads, the sulfide coating produced on the contact surface will not be broken down and contact faults will result. Use a microload switch that uses gold contacts. Do not use the switch in atmospheres with high humidity or heat or in harmful gases, such as sulfide gas (HS, SO), ammonia gas (NH), nitric acid gas (HNO), or chlorine gas (Cl). Doing so may impair functionality, such as with damage due to contacting faults or corrosion. The switch includes contacts. If the switch is used in an atmosphere with silicon gas, arc energy may cause silicon oxide (SiO) to accumulate on the contacts and result in contact failure. If there is silicon oil, silicon filling, silicon wiring, or other silicon products in the vicinity of the switch, use a contact protection circuit to limit arcing and remove the source of the silicon gas. Mounting Always make sure that the power is turned OFF before mounting, removing, or wiring the Switch, or performing maintenance. Electric shock or burning may occur. Selecting Models We recommend using Drip-proof Models (protection equivalent to IP6) in locations subject to floating dirt and dust. Other models do not have a protective structure. Wiring Use wire sizes that are suitable to the applied voltage and carried current. If you use a soldering iron to solder the wires, do not allow the tip of the soldering iron to exceed 80 C. If a Switch is used with insufficient soldering, abnormal heat and burning may occur. Solder for no more than s at 0 C and for no more than s at 80 C. If heat is applied for too long, the case may melt, the lead wire coverings may be scorched, and other characteristics of the Switch may deteriorate. Tightening The suitable tightening torque for screw terminals is given below. Screw terminals except for those on Split-contact Models (Z-0FY- B): 0.78 to.8 N m Screw terminals on Split-contact Models (Z-0FY-B): 0.49 to.8 N m Operation Make sure that the switching speed and frequency are is within the specified ranges.. If the switching speed is extremely slow, the contacts may not be switched smoothly, which may result in a contact failure or contact welding. 6

. If the switching speed is extremely fast, switching shock may damage the Switch prematurely. If the switching frequency is too high, the contacts may not be able to keep up with the speed. The rated permissible switching speed and frequency indicate the switching reliability of the Switch. The life of a Switch is determined at the specified switching speed. The life varies with the switching speed and frequency even when they are within the permissible ranges. Always conduct appropriate durability tests under actual conditions before using a Switch. Make sure that the actuator travel does not exceed the permissible OT position. The operating stroke must be set to 70% to 00% of the rated OT. Panel Mount Switch (Z-@Q@, Z-0@Q@) When mounting the panel mount plunger model with screws on a side surface, be careful of the dog angle and operation speed. Excessive dog angle or operation speed may damage the Switch. When using the panel mount plunger model mounted with screws on a side surface, be careful not to apply a large shock. Applying a shock exceeding,000 m/s may damage the Switch. When using the panel mount plunger model mounted with screws on a side surface, remove the hexagonal nuts from the actuator. High-sensitivity Switch (Z-H)/ Extra-high-sensitivity Switch (Z-H) When using the Switch in a DC circuit, be sure to provide an arc suppressor as well because the small contact gap of the Switch may result in contact troubles. In an application where a high repeat accuracy is required, limit the current that flows through the Switch to within 0. A. Also, use a relay to control a high-capacity load if the Switch is connected to such a load. (In this case, the exciting current of the relay coil is the load of the Switch.) Do not apply a force of 9.6 N or higher to the pin plunger. Exercise care that the environment conditions such as temperature and humidity do not change abruptly. Micro Load Applicable Range Using a model for ordinary loads to open or close the contact of a micro load circuit may result in faulty contact. Use models that operate in the following range. However, even when using micro load models within the operating range shown here, if inrush current occurs when the contact is opened or closed, it may increase contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% (λ 60). The equation, λ 60 = 0. 0-6 /operations indicates that the estimated malfunction rate is less than /,000,000 operations with a reliability level of 60%. DC voltage (V) 0 4 Unusable range Minimum applicable load 0 0. mw 0.6 ma ma Operating range for micro load models Z-0H 0 00,000 Z-0H 800 mw 6 ma Operating range for general load models Z-H, H Z-G Z-E Z-0FY Z-ER 00 ma 60 ma Current (ma) Z-@, Z-0FY ma at VDC 60 ma at VDC Models with Drip-proof Terminal Cover (Z-@A-BV) Wiring To attach the Protective Cover to the case, hold the cover in almost parallel to the case and then push it to the case. If the cover is pushed diagonally, the rubber packing may slip off, degrading the sealability of the Switch. Terminal with toothed washer Rubber packing Use round solderless terminals having the 4. dia. following dimensions to connect leads to the terminals. Tighten the screws of terminals to 8 a torque of 0.78 to.8 N m. Use the terminal shown below. 0 max. A cable 8. to 0. mm in diameter can be applicable to the sealing rubber of the lead outlet of the Switch. A two-core or three-core VCT cable having a cross-sectional area of. mm is especially suitable for this. Use M4 small screws with spring toothed washer are used as the terminal screws. Drip-proof Switch (Z-@) The Switch is not perfectly oil-tight; so do not dip it in oil or water. The rubber boots are made from weather-resistive chloroprene rubber. Do not use Basic Switches in places with radical changes in temperature. Rubber boots and rubber caps will tend to harden at lower ambient temperatures. If an Actuator is used in a pressed state for an extended period of time at low temperatures, it may return slowly or it may not return at all. OMRON can provide special Actuators for use at low temperature with rubber boots or rubber caps made of silicon rubber, which has superior resistance to cold. Ask your OMRON representative for details. Split-contact Switch (Z-0F@Y) The applicable current varies depending on how the contacts are used. If the Switch is connected in series, the Switch can endure a current to times higher than the current that can be applied in parallel connection. Flexible Rod Switch (Z-@NJ@, Drip-proof) When the rod is fully swung, the Switch may operate when the lever returns, causing chattering. Use a circuit that compensates for chattering wherever possible. Do not switch the rod to the fullest extent when the Switch is to break a power circuit because such a practice may cause metal deposition to occur between the mating contacts of the Switch. Other Precautions Do not apply excessive force with a screwdriver or other tool when attaching or removing the Protective Cover. Doing so may deform the Switch. Screwdriver The Drip-proof Terminal Protective Cover can be sued only with Switches with model numbers ending in -BV. Only the Terminal Protective Cover is available for maintenance. 7