Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS

Similar documents
TITAN FLOW CONTROL, INC.

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

TITAN FLOW CONTROL, INC.

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

ProFlo FatBoy

A1100 GUARDIAN OVERFILL PREVENTION SYSTEM

Dispenser Containment Manual. Product Manual * Publication Number: DCM-0001 * Issue Date: 05/27/09 Supercedes: 11/01/07

AMES 2016 Price List. Backflow Prevention Products and Repair Kits and Parts. Effective February 29, 2016

B-2000 INSTALLATION GUIDE AND MAINTENANCE INSTRUCTIONS

Price List. Backfl ow Prevention Products, Repair Kits, and Parts. Effective July 2, AmesFireWater.com 2018 AMES FIRE & WATERWORKS PRICE LIST

OPW Installation and Maintenance Instructions OPW Series Primary and Secondary Bucket Replacement Instructions

DeZURIK KUL KNIFE GATE VALVES

M-3025CB-AV Fuel Pump

STYLE 624, 638 QUICK-ATTACK FOAM TUBE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

Owner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.

RVF4109CH. Features. Dimensions RUVATI. Model: RVF4109CH Single Handle Bathroom Faucet

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

Aboveground Tank Equipment. Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co.

FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System

MODEL HD-BTC. Installation, Operation & Repair Parts Information REV041416

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products (VR-402-D) Single Wall Tank with Top Fill. 12 or 34. Pressure Vacuum Vent

Code Requirements on Aboveground Storage Tanks Dispensing Fuels At Motor Vehicle Fuel-Dispensing Stations

ESE Series Cast Iron Sewage Pumps

earth safe Fuel Systems for Critical Power

6 and 8 HAIR AND LINT STRAINERS

SHOP PRO FXP TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

SHOP PRO ST TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Utility Distribution Systems Installation, Operation, and Maintenance Manual

SERIES 300V 115 and 230 VOLT AC FUEL TRANSFER PUMP Owner's Operation & Safety Manual Models FR300V, FR301V, FR310V & FR311V

Installation and Operation Manual

SHOP PRO FXP 95 TECHNICAL MANUAL

QUALITY MISTING PUMPS

APCO ACS-1200/1700 COMBINATION SLOW CLOSING AIR/VACUUM VALVE

APCO CSV-1600 SURGE CHECK VALVE

FUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System

Premium Series Grease Dispensing Handle One and Two Piece Body Styles

SECTION VEHICLE FUEL DISPENSING EQUIPMENT

Data Sheet 11.1 Issue A

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

AMES 2013 Price List. Backflow Prevention Products. Effective April 1, 2013

MODEL 900 IMPELLER-TYPE FLOW METER

NOW UL LISTED. Patented

Data Sheet High Velocity Water Spray Nozzle. Issue B. Rapidrop Global. Ref: SPTDHV/E TECHNICAL DATA MAINTENANCE DESCRIPTION

INSTALLATION, OPERATION, SERVICE & REPAIR PARTS MANUAL FOR

Installation Instructions & Warranty

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

Installation Instructions & Warranty

AMERICAN AVK COMPANY TABLE OF CONTENTS

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

NE January 2016 THREE-WAY VALVES SERIES 1600 MODEL 1601 SERIES 1900 MODEL Previously manufactured by Dezurik and Honeywell

HIGH VELOCITY WATER SPRAY NOZZLE (BRASS)

PENSKE SHOP PRO FXP TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

Operator s Safety and Service Manual

INSTALLATION INSTRUCTIONS, PARTS LIST AND CONFIGURATION GUIDE FOR THE CARBONATOR. Large Model No

Installation, Operation, and Maintenance Manual

FUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System

DISTRIBUTED BY TULSA CHAIN.COM, LLC.

2244 West McDowell Road Phoenix, AZ RACE (fax) INSTALLATION INSTRUCTIONS FOR

PRODUCT NUMBERING SYSTEM SERIES PHASE. 1: Single Phase 3: Three Phase

DIRECT-DRIVE PRESSURE WASHERS

OPERATIONS MANUAL MODEL MT-500

Data Sheet 11.2 Issue B

Installation, Operation, Repair and Parts Manual

DeZURIK 2 20" BOS BUTTERFLY VALVES

QUALITY MISTING PUMPS

HP190SL Series Slimline Radon Fans

FOR TECHNICAL ASSISTANCE

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products 8 5 (VR-402-B) Single Wall Tank with Top Fill. 26 Alarm. Pressure Vacuum Vent

HR-20P Pneumatically Controlled Pressure Regulator

Installation Instructions

Remote Dispensing Cabinet 902V Series Cabinet Dispenser

FOR TECHNICAL ASSISTANCE

MODEL DX Pneumatic Diaphragm Actuator

Presoak & Tire/Engine Cleaner Systems (Air Pump) DU TC_A & DU PS_A

PENSKE SHOP PRO ST WITH 50/80 PSI REGULATOR TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

OPERATING INSTRUCTIONS FOR. J1 Drilling Machine. 1. Machine to be operated by trained personnel. 2. Instructions to be read before use.

BUREAU OF STANDARDS. Effective Date: 8/19/2016 Section No. 4. Version: 1.2 Procedure No. 3

MODEL 11A REGULATOR

Nor East. Instructions. Safety Messages. Inspection. Parts Nor East Controls. Service. Type 05 Air-O-Motor Actuator Used With Globe Valves

MODEL 1385 & 1385-H Professional Rotary Drum Pump

6400 Series Horizontal Loading Valves

Proteus 20B 20 Automatic Scrubber

AUTOMATION. Operator s Manual. NLS Series. Pneumatic Level Sensors. Rev. A1, 4/07

Owner s Manual. Soda Ash ph Neutralizer System

SERIES 2200 Replaceable Seat Butterfly Valves

Ball Valves. Quality Valves at Low Cost

Owner s Manual GLASSLINED PUMP TANK

Installation / Operation Instructions Sunnex ORION Series Exam Lights

7. Protection System Testing

Darley UHP-HV Diesel Specification 1

9.21 Tank Program Guide NYS Office of Mental Health Tank System Installation Guide

Installation Instructions & Warranty

II DISTRIBUTION & SUBSTATION TYPE C

Electrical... 5 Start-up... 6 Digital Pressure Switch Programming and Instructions... 7 Maintenance... 8 PRODUCT NUMBERING SYSTEM PHASE SERIES

Transcription:

Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS INSTALLATION INSTRUCTIONS UNIVERSAL VALVE COMPANY, INC. 478 SCHILLER ST. ELIZABETH, NJ 07206

Rev A Installation Instructions The Model 540 Pressure Regulator Valve is designed to be used in an Aboveground Storage Tank (AST) system, and a dispenser equipped with a suction pump. The vacuum created by the pump actuates the pressure regulator open, and it will automatically shut off when the pump is disengaged. The pressure regulator protects the pump and air eliminator from excessive pressure build up, and its in compliance with a Thermal Pressure relief back to the tank in accordance to NFPA-30 standards. Important Note Prior to installation read these instructions completely. Check to make sure all parts are included. Do not substitute parts for those provided, unless specified. Failure to properly follow these instructions may result in improper operation of the valve. Parts List Model 540PR Pressure Regulator Assembly 1 ½ Male Shear Adapter 2

Warranty Statement All UNIVERSAL products are guaranteed to be free from defects in materials and workmanship. All products are thoroughly tested before shipment and guaranteed to the extent of replacing only products found to be defective in manufacture. We cannot, however, allow claims for labor or consequential damage resulting from purchase, installation or misapplication of our products. Our responsibility ceases when products are accepted by transportation carriers. All goods are at the risk of the purchaser after they have been delivered by us to the carrier and receipt obtained from same (in good order). The right is reserved to make changes in pattern, design or materials when deemed necessary, without prior notice. Products, which have become obsolete by reason of design change or discontinued, as a manufactured item may not be returned for credit. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND SPECIFICALLY THE WARRANTIES OF MECHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Warning Universal Valve products should be used in compliance with applicable federal, state and local laws and regulations. Product selection should be based on physical specifications and limitations and compatibility with environment and material to be handled. Universal Valve makes no warranty of fitness for a particular use 3

Figure 1 4

Model 540 Installation Instructions WARNING WARNING WARNING Gasoline and Petroleum Products are Flammable, installation instructions should be read and understood by personnel prior to installation to avoid Death, Injury to persons or damage to equipment or property. Specific precautions must be followed when installing, servicing, or using Universal Equipment. 1) The Universal Model 540 Pressure Regulator valve must be installed and used in accordance with the latest revision of the National Fire Protection Code NFPA-30A. 2) Valve must be securely anchored to island or dispenser with shear section leveled with base of dispenser and top surface of base. 3) The model 540 Pressure Regulator is designed to operate at a maximum pressure of 50 PSI. 4) All valves used with the model 540 Pressure Regulator must be equipped with thermal expansion relief valves, an excess pressure could cause a component in pipe system to fail and loose product to the environment. 5) An Anti-siphon valve or Solenoid valve must be installed adjacent to the shutoff valve at the tank, in accordance to NFPA-30A Para 2-1.7 revision. An anti-siphon or solenoid valve prevents product loss due to failure of the down stream piping or system. 6) A shut-off or gate valve is required by NFPA 30 Para 2-2.7.1 Revision. A shut-off valve is used to isolate the product in the tank when servicing or replacing equipment on the down stream piping system 7) Installation of model 540 Pressure Regulator valve and other piping components must all be in accordance with the latest National Fire Protection Association Codes, NFPA-30, NFPA-30A, and NFPA-70 Model Number Model 540-PR Model Numbers Description Standard Model for 1 ½ Riser 5

Part Body and Ends Poppet Seals Diaphragm Shaft Guide Bushing O-Rings Material Material Cast Iron Cast Brass Molded Nitrile.050 Fairprene Brass UL Nitrile Bearings Male shear section Inter woven self lubricating sleeves Galvanized Steel pipe w/machined shear section Miscellaneous Info. A minimum pressure of 1 inch of vacuum is necessary to actuate valve open. 6

7