LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

Similar documents
Low-Peak 600V Class RK1

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

N0N A 250V One-Time Class H Fuse

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

General Data Dimensions (Inches) Bussmann

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube

Electric vehicle auxiliary fuses 500 Vdc, A

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

Low voltage, branch circuit fuses

General Purpose US Fuses

Low Voltage, Branch Circuit Rated Fuses

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

6.3 mm reverse quick connect

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

Bussmann. Circuit Protection Solutions

British BS 88 Fuses. High Speed Fuses. Introduction. General Information

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

Fast-acting supplemental fuse. For superior protection, Bussmann recommends upgrading to Low-Peak Class CC fuses. See data sheet # 1023.

Accessories. For product data sheets, visit

Ω 1 Ω Supplementary Fuses

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

BH-1 modular fuse blocks, 700 V, 400 A

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Assembly not available for new installations.

Fuseology. Dual-Element, Time-Delay Fuse Operation

UL248 North American Low Voltage Fuses

Recommended Procedures

Class gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

Ferrule fuses. High Speed Fuses

PT Medium voltage fuses for potential and small power transformers

Effective December 2015 Supersedes September 2013

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

Low-Peak fuses offer the industry s most advanced circuit protection

FUSES 8.1. Questions? Answers at Western US: CED-ELEV

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

UL Recognized power distribution blocks

High Speed Fuses. Section Contents Page

Compact Circuit Protector (CCP)

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

3.6. Current Limiting Fuses. Contents. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

Main Distribution Switchboard KRP-C_SP LPS-RK_SP KRP-C_SP DP1. Reduced Voltage Starter for Large Motor

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP)

Class J modular ferrule and knifeblade fuse blocks

Selection and application guide

Quik-Spec Coordination Panelboard Specifications

UL/CSA Listed Power Fuses P F THE MOST POPULAR UL/CSA LISTED POWER FUSES TO MEET THE MOST POPULAR PROTECTION PRIORITIES

TPC & TPCDS. Telpower Compact Fused Disconnect Switch. Bussmann. Telpower. DC Power Protection Systems

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES

Selective Coordination

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Compact Circuit Protector (CCP)

Semiconductor Fuses European Fuses

onlinecomponents.com

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

Engineering Dependable Protection

www. ElectricalPartManuals. com Engineering Dependable Protection

North American Power Fuses

Compact Circuit Protector

R-Rated medium voltage fuses for motor circuit protection

R-Rated medium voltage fuses for motor circuit protection

North American Power Fuses

CUBEFuse. CUBEFuse catalog numbers (amps)

PROTECTION AND CONTROL

Bulletin 1489 Circuit Breakers. Selection Guide

HIGH-SPEED SEMICONDUCTOR FUSES CATALOG POWR-SPEED PRODUCTS HIGH-SPEED FUSES FUSE BLOCKS & HOLDERS

Industrial Control Transformers

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

KLKD SERIES 10x38 FUSES

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

Volume 4C: Circuit Protection Bussmann series solutions

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Protistor size 70 gr 690VAC (IEC)

Miniature Circuit Breakers

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

PD-Series Ground Fault Circuit Protection

Specification made simple for selective coordination in a compact size

Now - Up To 400A Mains!

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

Equipment Protection. Transformers 600V or Less

1489-M Circuit Breakers

overvoltage solutions

Evaluating Selective Coordination Between Current-Limiting Fuses And Non Current-Limiting Circuit Breakers

Volts: 600V Amps: up to 30A limited by conductor size Withstand: 200kA RMS Sym. Operating and storage temperature:

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

C E R T I F I C A T E O F C O M P L I A N C E

up to 30A limited by conductor size Operating and storage temperature:

Transcription:

Bussmann LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt 601-2000A Dimensional Data All other lerances (± 0.02) 0.63" (± 0.03) All Slots and Holes 10.75" (± 0.09) 8.63" (± 0.09) 6.75" 5.75" 601A 800A 801A 1200A 1350A 1600A 1800A 2000A 3.75".38".38".44".5" Terminal: Width (± 0.06) Thickness (± 0.03) 2" 2" 2.38" 2.75" 2.5" 2.53" 2.5" 2.78" 3" 3.03" 3.5" 3.53" Catalog Symbol: KRP-C-SP Time-Delay 4 seconds (minimum) at 500% rated current Current-Limiting Ampere Rating: 601 2000 Amperes Voltage Rating: 600 Volts AC (or less) 300 Volts DC (or less) Interrupting Rating: 300,000A RMS Sym. (UL) Interrupting Rating: 100,000A DC (UL) Agency Approvals: UL Listed Special Purpose, Guide JFHR, File E56412 CSA Certified (200,000 AIR), Class 1422-02, File 53787 Class L per CSA C22.2, No. 248.10 Use KRP-CL for current ratings below 601 amps. *601-3000A is rated 340 VDC and 50 KAIC. Meets all performance requirements of UL Standard 248-10 for Class L fuses. Ampere Ratings Catalog Ctn. Weight** Catalog Ctn. Weight** Number Qty. Lbs. Kg. Number Qty. Lbs. Kg. KRP-C-601SP KRP-C-1350SP KRP-C-650SP KRP-C-1400SP KRP-C-700SP 1 3.75 1.7 KRP-C-1500SP 1 6.50 2.948 KRP-C-750SP KRP-C-1600SP KRP-C-800SP KRP-C-1800SP KRP-C-801SP KRP-C-1900SP 1 8.5 3.85 KRP-C-900SP KRP-C-2000SP KRP-C-1000SP 1 4.5 2.041 KRP-C-1100SP KRP-C-1200SP **Weight per carn. Special purpose rating of 300,000 AIR. General Information: All-purpose silver-linked fuse for both overload and shortcircuit protection for high capacity systems (mains and large feeders). Time-delay (minimum of four seconds at five times amp rating) for close sizing. Current-limiting action of the fuse generally affords considerable reduction in bus bracing. Interrupting rating of 300,000 amperes complies with NEC Sections 110-9 and 230-65 for day s large capacity systems. O-ring seals maximize pressure build-up during currentlimiting action and ensure filler retention. High grade silica-sand filler; accelerates response of fuse short-circuits by having quenching effect upon the fuse arc. 99.9% pure silver fuselinks. The high conductivity of silver gives low watt loss and low operating temperature at normal current levels; maximizes tal clearing I 2 t fault energy let-through. Selective coordination (blackout prevention). Glass melamine tube. Silver-plated end bells. CE logo denotes compliance with European Union Low Voltage Directive (50-1000 VAC, 75-1500 VDC). Refer BIF document #8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Form No. KRP-C-601-2000 Page 1 of 3 BIF Doc #1008

Bussmann LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt 601-2000A Time-Current Characteristic Curves Average Melt Fuseblocks: (601-1200 Amps) Catalog Number Poles 51215 1 51235 3 No reducers available. 300 100 800A 1200A 1600A 2000A AMPERE RATING 10 TIME IN SECONDS 1.1.01 1,000 10,000 CURRENT IN AMPERES 100,000 200,000 Form No. KRP-C-601-2000 Page 2 of 3 BIF Doc #1008

Bussmann LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt 601-2000A Current-Limitation Curves The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, change design or construction of any products and discontinue or limit distribution of any products. Bussmann also reserves the right change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Form No. KRP-C-601-2000 Page 3 of 3 BIF Doc #1008

LOW-PEAK Time-Delay Fuses Bussmann KRP-C Class L 600 Volt 2001-6000A Dimensional Data Hole diameters and slot widths (±0.03) All other lerances (± 0.02).88" 1.75" 1.38" 1.63" 1.75" 1.38".81".88" 2001A 2500A 3000A 3500A 4000A 4500A 5000A 6000A 6.75" 3.75" 10.75" (± 0.09).75".75".75" 1" 1" Terminals: Width (± 0.06) Thickness (± 0.03) 3.5" 4" 4.75" 5.25" 5.75" 5" 5.03" 5" 5.03" 5.75" 5.79" 6.25" 7.17" 7.13" 7.17" Catalog Symbol: KRP-C_SP Time-Delay 4 seconds (minimum) at 500% rated current Current-Limiting Ampere Rating: 2001 6000 Amperes Voltage Rating: 600 Volts AC (or less)* Interrupting Rating: 300,000A RMS Sym. (UL) Agency Approvals: UL Listed Special Purpose, Guide JFHR, File E56412 CSA Certified (200,000 AIR), Class 1422-02, File 53787 Class L per CSA-C22.2 No. 248.10 *601-3000A is rated 340 VDC and 50 KAIC. Meets all performance requirements of UL Standard 248-10 for Class L fuses. Ampere Ratings Catalog Ctn. Weight** Catalog Ctn. Weight** Number Qty. Lbs. Kg. Number Qty. Lbs. Kg. KRP-C-2001SP KRP-C-4500SP KRP-C-2400SP 1 17.25 7.824 KRP-C-5000SP 1 29 13.154 KRP-C-2500SP KRP-C-6000SP 1 36 16.329 KRP-C-3000SP 1 18.25 8.278 KRP-C-3500SP KRP-C-3800SP 1 23.50 10.659 KRP-C-4000SP Special purpose rating of 300,000 AIR. **Weight per carn. General Information: All purpose silver-linked fuse for both overload and short-circuit protection for high capacity systems (mains and large feeders). Time-delay (minimum of four seconds at five times amp rating) for close sizing. Current-limiting action of the fuse generally affords considerable reduction in bus bracing. Interrupting rating of 300,000 amperes complies with NEC Sections 110-9 and 230-65 for day s large capacity systems. O-ring seals maximize pressure build-up during current-limiting action and ensure filler retention. High grade silica-sand filler; accelerates response of fuse short-circuits by having quenching effect upon the fuse arc. 99.9% pure silver fuselinks. The high conductivity of silver gives low watt loss and low operating temperature at normal current levels; maximizes tal clearing I 2 t fault energy let-through. Selective coordination (blackout prevention) Glass melamine tube. Silver-plated end bells. CE logo denotes compliance with European Union Low Voltage Directive (50-1000 VAC, 75-1500 VDC). Refer BIF document #8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Form No. KRP-C 2001-6000 Page 1 of 3 BIF Doc #1009

LOW-PEAK Time-Delay Fuses Bussmann KRP-C Class L 600 Volt 2001-6000A Time-Current Characteristic Curves Average Melt 300 2500A 3000A 4000A 5000A 6000A AMPERE RATING 100 10 TIME IN SECONDS 1.1.01 1,000 10,000 CURRENT IN AMPERES 100,000 200,000 Form No. KRP-C 2001-6000 Page 2 of 3 BIF Doc #1009

LOW-PEAK Time-Delay Fuses Bussmann KRP-C Class L 600 Volt 2001-6000A Current-Limitation Curves The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, change design or construction of any products and discontinue or limit distribution of any products. Bussmann also reserves the right change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Form No. KRP-C 2001-6000 Page 3 of 3 BIF Doc #1009